wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: OPTICAL PROPERTIES
-
The equations for interactions of polarization modes in optical fibres including the kerr effect
PublikacjaWe have derived coupled nonlinear Schro¨ dinger equations (CNLSE) for arbitrary polarized light propagation in a single-mode fibre employing electromagnetic field complete description. We used a basis of transverse eigenmodes with appropriate projecting; hence, the nonlinear constants depend on the waveguide geometry. Accounting for a weak nonlinearity, which is connected to the Kerr effect, we have given explicit expressions for...
-
Stability of an optical displacement sensor using a two-beam polarization interferometer
PublikacjaW artykule przedstawiono wyniki pomiarów stabilności wybranej konfiguracji dwuwiązkowego interferometru polaryzacyjnego. Przedyskutowano źródła występującej niestabilności.
-
Bimolecular excited species in optical emission from organic electroluminescent devices
PublikacjaW pracy dokonano przeglądu dwu-molekularnych stanów wzbudzonych emitujących światło (ekscymery, ekscypleksy, elektromery, elektropleksy) w organicznych diodach EL
-
Molecular self-assembly and optical activity of chiral thionooxalamic acid esters
PublikacjaZsyntezowano kilka optycznie czynnych estrów dietylowych kwasu bis(tiooksamowego). Związki te, z powodu ich zdolności do tworzenia ze sobą komplementarnych cyklicznych wiązań wodorowych, są potencjalnie użytecznym materiałem budulcowym większych układów supramolekularnych. Odpowiednie układy modelowe otrzymano z optycznie czynnych 1,2-diamin, które poddano acylowaniu chlorooksooctanem etylu, a następnie otrzymane półprodukty tionowano...
-
Optical recognition elements. Macrocyclic imidazole chromoionophores entrapped in silica xerogel
PublikacjaNowe chromojonofory zawierające fragment eteru koronowego i resztę azolu zostały unieruchomione w krzemionkowej matrycy żelowej metodą zol-żel i zbadane jako optyczne elementy rozpoznające kationy Li+,Cs+, Cu2+. Elementy optyczne oparte na 21-członowych pochodnych imidazolu i 4-metyloimidazolu rozpoznawały jony Li+ w roztworze wodnym. Wyznaczono parametry g i A na podstawie badań EPR dla kompleksów 18-członowej i 21-członowej pochodnej...
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublikacjaThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Optical theorem helps understand thresholds of lasing in open semiconductor microcavities
Publikacja -
Optical Theorem Helps Understand Thresholds of Lasing in Microcavities With Active Regions
Publikacja -
Optical fiber technology in Poland: four decades of development 1975-2015
Publikacja -
<title>Current developments of multicrucible technology of tailored optical fibers</title>
Publikacja -
<title>Colorimetric sensor based on two optical fiber couplers</title>
Publikacja -
Directions Of Applications Of Optical Fiber Technology In Medicine And Health Protection Systems
Publikacja -
?? of the Sky? - automated search for fast optical transients over the whole sky
Publikacja -
Recognition Of Colours And Collision Avoidance In Robotics Using Optical Fiber Sensors
Publikacja -
<title>Temperature sensor based on double-core optical fiber</title>
Publikacja -
<title>Octopus-Like-Shape Cored Optical Fibres /OLSCF/</title>
Publikacja -
<title>Optical fiber transmission with wavelength multiplexing: faster or denser?</title>
Publikacja -
<title>Atom guiding in single mode optical fiber capillary</title>
Publikacja -
Salicylaldimine-based receptor as a material for iron(III) selective optical sensing
Publikacjaα,α-Bis(salicylimino)-m-xylene (L) was prepared using both conventional and microwave-assisted procedure. The compound exhibits ability to colorimetric recognition of iron(III) ions in aqueous environment, what is shown by significant color change from yellow to purple. In DMSO : water (9:1 v/v) solvent system receptor creates with iron(III) cations complexes of 2:1 stoichiometry (L:Fe3+) with stability constant (log K) 7.54±0.21....
-
Multilayered structures examination using polarization sensitive optical coherence tomography
PublikacjaW artykule przedstawiono wstępne wyniki badań struktur warstwowych z użyciem systemu optycznej tomografii koherentnej z analizą stanu poaryzacji (PS-OCT). Omówiono budowę systemu oraz zakres stosowalności metody do badania złożonych struktur warstwowych.
-
Initial evaluation of commercial optical CT‐based 3D gel dosimeter
Publikacja -
Determining optimal gel sensitivity in optical CT scanning of gel dosimeters
Publikacja -
PbGa2GeS6 crystal as a novel nonlinear optical material: Band structure aspects
Publikacja -
Synthesis, ellipsometry and non-linear optical features of substituted 1,3,5-triphenylpyrazolines
Publikacja -
Functionalized mesoporous silica thin films as a tunable nonlinear optical material
Publikacja -
Optical Spectroscopic Studies of Tetrahydrofuran Fragmentation Induced by Collisions with Dihydrogen Cations
PublikacjaCollisions of dihydrogen cations with tetrahydrofuran molecules have been studied. Luminescence spectra and the emission functions of the excited products at projectile energies ranging from 8 to 1000 eV have been measured using collision-induced emission spectroscopy. The recorded spectra are dominated by the atomic lines of the hydrogen Balmer series, whose intensities decrease more quickly than derived by the quantum-theoretical...
-
Investigation of energy deposition and its optical imaging in polymer gel dosimeters
PublikacjaThis following chapter describes methods for verifying the absorbed dose during radiotherapy. Special attention is paid to the method using polymer-gel dosimeters, the dose reading of which is performed by means of Laser Computed Tomography. The chapter also includes considerations on alternative solutions for dosimetric measurements and various types of radiotherapy and their pros and cons. In addition, both the methods of structural...
-
Characterization of PLZT Thin Films for Fast Electro-Optical Sampling Circuits
PublikacjaW artykule omówiono technologię wytwarzania cienkich warstw wybranych kompozycji ceramik ołowiowo-lantanowo-cyrkonowo-tytanowych, nazywanych ceramikami PLZT. Przedstawiono wyniki badań jakości warstw za pomocą techniki XRD. wyniki pomiaru grubości warstw, ich względnej przenikalności dielektrycznej i współczynnika załamania. Omówiono kierunki dalszych prac.
-
A Chemical Recognition Element for Lithium Ions Based on Optical Electronic Absorption.
PublikacjaOtrzymano próbki kserożeli techniką zol-żel. Otrzymane materiały zastosowano do konstrukcji czujników optycznych. Rolę elementu rozpoznającego w uzyskanych próbkach pełnią chromogeniczne etery koronowe zawierające w makro pierścieniu dwie grupy azowe oraz resztę fenolu. W obecności soli metali I grupy układ u okresowego obserwowano zmiany w widmach absorpcyjnych. Dla matrycy zawierającej jako materiał czujnikowy 21-członową...
-
Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography.
PublikacjaOptyczne metody pomiarowe odgrywają w ostatnich latach coraz większą rolę w badaniach i diagnostyce medycznej. Mają one szereg zalet, do których zaliczyć można odporność na promieniowanie elektromagnetyczne, bezinwazyjność, bezpieczeństwo pomiaru oraz wysoką rozdzielczość. Jedną z najważniejszych technik stosowanych w diagnostyce medycznej jest koherentna tomografia optyczna (OCT). Jest to wysokorozdzielcza metoda obrazowania wewnętrznych...
-
Estimation of optical parameters of highly scattering materials by time-of-flight spectroscopy.
PublikacjaPrzedstawiono metody wyznaczania podstawowych parametrów materiałów silnie rozpraszających światło na podstawie pomierzonego rozkładu czasu przelotu krótkich impulsów laserowych. W algorytmie wykorzystano metodę Monte Carlo i metodę dyfuzji do opisu propagacji światła. Oszacowano dokładność oszacowywania tych parametrów.
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublikacjaThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
New matrix-free reference material for ethene in the form of optical fibres
PublikacjaReference materials are indispensable in the qualitycontrol and quality assurance of analytical measurements. Onenovel approach to the generation of standard gaseous mixturesof toxic, reactive, volatile, labile, and malodorous substancesinvolves thermal decomposition or rearrangement, under definedtemperature conditions, of compounds immobilized, bychemical bonding, on the surface of an appropriate carrier torelease specific amounts...
-
A navigation device utilizing body communication channel for mobile wearable systems
PublikacjaA novel touch sensor utilizing a body communication technology is presented in the paper. The proposed device accepts orders (gestures) only from a person wearing it. Moreover, when comparing it to a similar, however an optical one, it appears as a less power consumable. Preliminary results of its properties examination are presented and discussed. Additionally, the developed sensor allows to measure a human body the electrical...
-
Influence of Surface Laser Treatment on Mechanical Properties and Residual Stresses of Titanium and its Alloys
PublikacjaSurface modification of the titanium and its alloys used in implantology with a long-pulse laser can change the surface topography, but it also leads to changes in the stress sign and magnitude in the resulting subsurface layer. The presented research was aimed at evaluating the state of stress after laser remelting with the Nd:YAG laser of pre-etched titanium alloys Ti6Al4V and Ti13Nb13Zr and pure titanium. The obtained surface...
-
The Influence of Camera and Optical System Parameters on the Uncertainty of Object Location Measurement in Vision Systems
PublikacjaThe article presents the influence of the camera and its optical system on the uncertainty of object position measurement in vision systems. The aim of the article is to present the methodology for estimating the combined standard uncertainty of measuring the object position with a vision camera treated as a measuring device. The identification of factors affecting the location measurement uncertainty and the determination of their...
-
π-Conjugated Donor-acceptor Polyelectrolytes: Toward Artificial Photosynthesis
PublikacjaGreat advances have been made in the development of conjugated polyelectrolytes (CPEs), which provide tunable properties including water solubility and processability, main-chain exciton and charge transport, variable energy light absorption and fluorescence, non-covalent interactions, and formation of tertiary structures via self-assembly.[1] These characteristics allow CPEs to be considered for use in various optoelectronic applications,...
-
Exploration of optical fibres as a carrier for new benzene and toluene matrix-free reference materials
PublikacjaTo meet high expectations concerning precision and accuracy of reference materials, preparation of matrixfree reference materials using thermal decomposition-gas chromatography-mass spectrometry (TD-GC-MS) was proposed in this study. In the paper, the results obtained in preparation of the new reference materials for benzene and toluene are presented, based on the thermal decomposition technique of compounds chemically bound to...
-
Vident-synth: a synthetic intra-oral video dataset for optical flow estimation
Dane BadawczeWe introduce Vident-synth, a large dataset of synthetic dental videos with corresponding ground truth forward and backward optical flows and occlusion masks. It can be used for:
-
Role of nitrogen in optical and electrical band gaps of hydrogenated/hydrogen free carbon nitride film
PublikacjaWe report the optical and electrical band gap energy of amorphous hydrogenated carbon nitride (a-HCNx) and carbon nitride (a-CNx) as a function of nitrogen concentration (N/C). The optical band gap of a-HCNx and a-CNx films has been determined by means of Ellipsometry and UV-VIS. Both optical and electrical band gaps increase with elevated nitrogen concentration. Experimentally obtained electrical band gap is compared with the...
-
Mechanical and fracture properties of concrete reinforced with recycled and industrial steel fibers using Digital Image Correlation technique and X-ray micro computed tomography
PublikacjaPaper presents investigation of fracture phenomenon in plain concrete and in concrete reinforced with both recycled steel fibers (RSF) and industrial steel fibers (ISF). The wedge splitting test (WST), which enables stable crack propagation for quasi-brittle materials, was carried out on 75 75 75 mm cube samples. Initially, fracture process zone development was investigated only on the surface of samples using Digital Image Correlation...
-
Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser.
Dane BadawczeApplication of laboratory set-up for characterisation of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes thermographic camera VIGOcam v50 and dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Study on Microstructure and Mechanical Properties of Laser Welded Dissimilar Joint of P91 Steel and INCOLOY 800HT Nickel Alloy
PublikacjaThis investigation attempts to explore the weld characteristics of a laser welded dissimilar joint of ferritic/martensitic 9Cr-1Mo-V-Nb (P91) steel and Incoloy 800HT austenitic nickel alloy. This dissimilar joint is essential in power generating nuclear and thermal plants operating at 600–650 °C. In such critical operating conditions, it is essential for a dissimilar joint to preserve its characteristics and be free from any kind...
-
High-Power Jamming Attack Mitigation Techniques in Spectrally-Spatially Flexible Optical Networks
PublikacjaThis work presents efficient connection provisioning techniques mitigating high-power jamming attacks in spectrally-spatially flexible optical networks (SS-FONs) utilizing multicore fibers. High-power jamming attacks are modeled based on their impact on the lightpaths’ quality of transmission (QoT) through inter-core crosstalk. Based on a desired threshold on a lightpath’s QoT, the modulation format used, the length of the path,...
-
Optical Sensor Based Gestures Inference Using Recurrent Neural Network in Mobile Conditions
PublikacjaIn this paper the implementation of recurrent neural network models for hand gesture recognition on edge devices was performed. The models were trained with 27 hand gestures recorded with the use of a linear optical sensor consisting of 8 photodiodes and 4 LEDs. Different models, trained off-line, were tested in terms of different network topologies (different number of neurons and layers) and different effective sampling frequency...
-
Influence of reactive oxygen species during deposition of iron oxide films by high power impulse magnetron sputtering.
PublikacjaIron oxide films were deposited using high power impulse magnetron sputtering (HiPIMS) of an iron cathode in an argon/oxygen gas mixture at different gas pressures (0.5~Pa, 1.5~Pa, and 5.0~Pa). The HiPIMS system was operated at a repetition frequency $f = 100$~Hz with a duty cycle of 1~\%. A main goal is a comparison of film growth during conventional and electron cyclotron wave resonance-assisted HiPIMS. The deposition plasma...
-
Optoelectronic device for hematocrit measurements
PublikacjaAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Fiber-optic sensors based on microspheres with nanocoatings (Zastosowanie mikrosfer optycznych z cienkowarstwowymi pokryciami w czujnikach światłowodowych)
PublikacjaTemperature is one of the most important physical quantities. Temperature measurements are used in every field of life, especially electronics, electrical engineering, energy-related fields, including energy source and storage devices. The goal of this dissertation is to design and optimize the microsphere-based fiber-optic sensors construction for measurement of the sensor surrounding medium temperature, including selection of...
-
Hardware implementation of digital image stabilization using optical flow algorithm and FPGA technology
PublikacjaW artykule przedstawiono efektywną procedurę uproszczenia algorytmu przepływu optycznego oraz jego realizację w układzie programowalnym FPGA. Zmodyfikowany algorytm wykorzystuję metodę blokowego dopasowania podobszarów oraz jednowymiarową reprezentację podobszarów. Dodatkowo, funkcja korelacji oparta jest o normę L1. W rezultacie uzyskano zmniejszenie zużytych zasobów kosztem nieznacznej utraty dokładności. Zarówno dokładność,...
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublikacjaRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...