Wyniki wyszukiwania dla: AKTUATORY%20PIEZOELEKTRYCZNE
-
Hybrid piezoelectric motor based on electroactive lubrication principle
PublikacjaA novel conception of hybrid piezoelectric motor is presented in this paper. Proposed conception required synchronised work of quasi-static and resonant piezoelectric actuators that results in a rotary movement. The motor's working principle is explained and the main characteristics are described. Studied topology is compared to the existing piezoelectric motors with regards to its field of applications. The assembling process...
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 500 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 500 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1100 g
Dane Badawcze -
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Artificial-Hand Technology—Current State of Knowledge in Designing and Forecasting Changes
PublikacjaThe subject of human-hand versatility has been intensively investigated for many years. Emerging robotic constructions change continuously in order to mimic natural mechanisms as accurately as possible. Such an attitude is motivated by the demand for humanoid robots with sophisticated end effectors and highly biomimic prostheses. This paper provides wide analysis of more than 80 devices that have been created over the last 40 years....
-
Reliability data safety instrumented systems SIS from the functional safety analysis example critical instalation
Dane BadawczeThe dataset represents the results of an example of functional safety analysis systems is presented below. It is based on a control system, which consists of some basic components like sensors, programmable logic controllers and valves. It is a part of petrochemical critical installations. The communication between sensor logic controllers and actuators...
-
Fuzzy Control of Waves Generation in a Towing Tank
PublikacjaThis paper presents the results of research related to the transformation of electrical energy into potential and kinetic energy of waves generated on the water surface. The waves are generated to model the environmental conditions for the needs of the model tests. The model tests are performed on model-scale objects to predict the features of full-scale maritime objects. It is done to improve human safety and the survivability...
-
Assembling and testing of quasi-static hybrid piezoelectric motor based on electroactive lubrication principle
PublikacjaThe presented paper concerns a novel concept of hybrid piezoelectric motor based on electroactive lubrication principle. Its structure is combined of quasi-static and resonance piezoelectric actuators, synchronizing their work to generate the rotary movement. The hybrid motor topology is compared to the existing piezoelectric motors, regarding its field of applications in embedded systems with very high security requirements. The...
-
System pozycjonowania dynamicznego morskich jednostek pływających jako system mechatroniczny
PublikacjaW artykule przedstawiano system pozycjonowania dynamicznego półzanurzeniowej platformy wiertniczej, który jest rozpatrywany jako system mechatroniczny. W szczególności zaś zaprezentowano systemy referencyjne utrzymania stanowiska pozycyjnego na morzu, urządzenia nawigacyjne, czujniki ruchów własnych jednostki pływającej i anemometry rozważane jako czujniki systemu mechatronicznego oraz pędniki azymutalne rozważane jako nastawniki...
-
Realization, programming and controlling of the Stewart-Gough platform
PublikacjaThis paper presents realizaon, programming, and controlling of a low cost Stewart-Gough plaorm (SGP) with rotary actuators. The realized SGP is applied in a ball & plate control system. Developed dedicated software consists of embedded and applicaon soware for both the SGP posioning system and the ball & plate control. system. A ball posion is being obtained using computer vision. The paper contains tests results for both an SGP...
-
Digital Control System of the Wavemaker in the Towing Tank
PublikacjaThe paper describes a digital control system of the rigid flap wavemaker in a towing tank in CTO S.A. Ship Design and Research Centre. The control system is based on an 8-bit AVR microcontroller and consists of two cascading PID controllers. The digital system replaced the previous analogue system from 1974 and has been integrated with the existing sensors and actuators of the wavemaker. The new control system allows to obtain...
-
Nonlinear free and forced vibrations of a dielectric elastomer-based microcantilever for atomic force microscopy
PublikacjaThe majority of atomic force microcode (AFM) probes work based on piezoelectric actuation. However, some undesirable phenomena such as creep and hysteresis may appear in the piezoelectric actuators that limit their applications. This paper proposes a novel AFM probe based on dielectric elastomer actuators (DEAs). The DE is modeled via the use of a hyperelastic Cosserat model. Size effects and geometric nonlinearity are included...
-
Application of wavelet transform in analysis of guided wave propagation signals for damage detection in a steel plate
PublikacjaThe paper presents results of experimental investigations on damage detection using guided wave propagation technique. The tested specimen was a steel plate with a defect in the form of a rectangular notch. Lamb waves were excited by a PZT actuator and sensed by a laser vibrometer. Since reflections from damage in registered signals are often masked by measurement noise, for identification of time of reflections from damage, continuous...
-
Elastic wave propagation for condition assessment of steel bar embedded in mortar
PublikacjaThis study deals with experimental and numerical investigations of elastic wave propagation in steel bars partially embedded in mortar. The bars with different bonding lengths were tested. Two types of damage were considered: damage of the steel bar and damage of the mortar. Longitudinal waves were excited by a piezoelectric actuator and a vibrometer was used to non-contact measurements of velocity signals. Numerical calculations...
-
Acoustic journal bearing – Performance under various load and speed conditions speed conditions
PublikacjaThe paper presents results of experimental testing aiming at finding out what effect system of piezo-electric actuators (PZTs)attached to an aerodynamic journal bearing has on the magnitude of shaft's motion within the bearing operating at specified speed and load. The results clearly demonstrate effectiveness of PZTs in mitigating the shaft's motion thus contributing to the increased stability of the bearing. This stabilizing...
-
Lamb wave propagation in a single lap adhesive joint
PublikacjaThe aim of the paper is the analysis of Lamb wave propagation in adhesive joints. The research was performed on a single lap adhesive joint of two steel plates. Two types of joints, namely an intact and with defect were considered. In experimental investigations the condition assessment of the joint was performed with the use of antisymmetric Lamb waves excited by a plate piezo actuators and measured by a laser vibrometer. Numeri-cal...
-
Struktura systemu diagnostycznego ciągnika kołowego
PublikacjaSystemy diagnostyczne OBD (On Board Diagnosis) są coraz częściej stosowane w pojazdach. Tylko niektóre ciągniki kołowe są wyposażone w systemy diagnostyczne. Dotychczas stosowana diagnostyka pokładowa pojazdów jest silnie związana z wymaganiami emisyjnymi i nie obejmuje innych ważnych funkcji pojazdu. W tworzonym systemie diagnostycznym ciągnika kołowego, ze względu na możliwe skutki przyjęto cztery grupy uszkodzeń: funkcjonalne...
-
Control design for slow speed positioning
PublikacjaThe problem under study is a synthesis of position and heading control system for low frequency model of surface vessel described by 3 DOF mathematical model. The recursive vectorial backstepping control design was used to keep fixed position and heading in presence of wave disturbances. The controller has been simulated on computer model of scaled supply vessel. It has been assumed that the actuators produce generalized forces...
-
Displacement control in PWK-type pumps
PublikacjaThe most important, strategic goal however is creation of the variable displacement version of the new pump PWK. Thanks to full discharge of it's commutation mechanism from hydrostatic forces the variable pump can be directly controlled by low-energy actuator like proportional electromagnet or stepping motor. It means that costly and complicated hydraulic servomechanism (applied in all present variable displacement pumps) is no...
-
Free Vibration of Flexomagnetic Nanostructured Tubes Based on Stress-driven Nonlocal Elasticity
PublikacjaA framework for the flexomagneticity influence is here considered extending the studies about this aspect on the small scale actuators. The developed model accommodates and composes linear Lagrangian strains, Euler-Bernoulli beam approach as well as an extended case of Hamilton’s principle. The nanostructured tube should subsume and incorporate size effect; however, for the sake of avoiding the staggering costs of experiments,...
-
Struktura systemu diagnostycznego cągnika kołowego
PublikacjaSystemy diagnostyczne OBD (On Board Diagnosis) są coraz częściej stosowane w pojazdach. Tylko niektóre ciągniki kołowe są wyposażone w systemy diagnostyczne. Dotychczas stosowana diagnostyka pokładowa pojazdów jest silnie związana z wymaganiami emisyjnymi i nie obejmuje innych ważnych funkcji pojazdu. W tworzonym systemie diagnostycznym ciągnika kołowego, ze względu na możliwe skutki przyjęto cztery grupy uszkodzeń: funkcjonalne...
-
Numerical investigation on the performance of a small counter-rotating wind turbine
PublikacjaThe article presents the results of the investigation on the performance of a small counter-rotating wind turbine. The wind turbine has been simulated using Computational Fluid Dynamics methods. Actuator Line Model has been successfully used to represent rotors in the computational domain. A parametric study has been carried out, taking into account changes in the tip speed ratio of the rotors while maintaining a constant distance...
-
Wave propagation in damage assessment of ground anchors
PublikacjaThe inspection possibilities of ground anchors are limited to destructive test such as pull-out test. Guided wave propagation gives an opportunity to develop an inspection system dedicated to determine the condition of inspected element without violation of their integrity. In this paper the experimental study on wave propagation in laboratory models of ground anchors are presented. Experiments were conducted for different bonding...