wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: MENISCUS- BONE ANGLE
-
Assessment of the Relationship between the Shape of the Lateral Meniscus and the Risk of Extrusion Based on MRI Examination of the Knee Joint
PublikacjaBackground Meniscus extrusion is a serious and relatively frequent clinical problem. For this reason the role of different risk factors for this pathology is still the subject of debate. The goal of this study was to verify the results of previous theoretical work, based on the mathematical models, regarding a relationship between the cross-section shape of the meniscus and the risk of its extrusion. Materials and Methods Knee...
-
The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion
PublikacjaObjective The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. Methods One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then...
-
Wpływ wysokiej osteotomii piszczelowej na mechanikę stawu kolanowego
PublikacjaW rozprawie podjęto próbę weryfikacji wpływu zabiegu chirurgicznego wysokiej osteotomii piszczelowej na mechanikę stawu kolanowego. Po wykonanym przeglądzie literatury, postawiono trzy hipotezy, które poddano weryfikacji na drodze badań numerycznych. Otrzymane wyniki zwalidowano poprzez badania nacisków powierzchniowych występujących w stawach kolanowych świni domowej, prowadzonych na maszynie do jednoosiowego ściskania. Praca...
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublikacjaBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...
-
Biological and mechanical properties of bone cement with nanoarticles - in vitro and in vivo research
PublikacjaDespite antibiotic preventive treatment both before and after implant implementation, the risks of infection are real. These infections develop at the implant surface a few months after inserting them into the body. To prevent the development of bacteria and reduce the risk of infection, implants coated with nanoparticles are used. The Mechanical Department of the Technical University of Gdansk carries out research into using bone...
-
Bone healing under different lay‐up configuration of carbon fiber‐reinforced PEEK composite plates
PublikacjaSecondary healing of fractured bones requires an application of an appropriate fixa-tor. In general, steel or titanium devices are used mostly. However, in recent years,composite structures arise as an attractive alternative due to high strength to weightratio and other advantages like, for example, radiolucency. According to Food andDrug Administration (FDA), the only unidirectionally reinforced composite allowed tobe implanted...
-
Influence of Different Nanometals Implemented in PMMA Bone Cement on Biological and Mechanical Properties
PublikacjaCemented arthroplasty is a common process to fix prostheses when a patient becomes older and his/her bone quality deteriorates. The applied cements are biocompatible, can transfer loads, and dampen vibrations, but do not provide antibacterial protection. The present work is aimed at the development of cement with antibacterial effectivity achieved with the implementation of nanoparticles of different metals. The powders of Ag,...
-
The determinants of morphology and properties of the nanohydroxyapatite coating deposited on the Ti13Zr13Nb alloy by electrophoretic techniqe
PublikacjaThe titanium and its alloys belong at present to the most preferred and commonly applied biomaterials for load- bearing implants. The surfaces of biomaterials are subjected to modification, including the hydroxyapatite coatings deposited in order to ensure corrosion resistance and better joining between an implant and a bone through the possibility of ingrowth bone into the coating. In this paper, the morphology and properties...
-
Polyurethanes Crosslinked with Poly(vinyl alcohol) as a Slowly-Degradable and Hydrophilic Materials of Potential Use in Regenerative Medicine
PublikacjaNovel, slowly-degradable and hydrophilic materials with proper mechanical properties and surface characteristics are in great demand within the biomedical field. In this paper, the design, synthesis, and characterization of polyurethanes (PUR) crosslinked with poly(vinyl alcohol) (PVA) as a new proposition for regenerative medicine is described. PVA-crosslinked PURs were synthesized by a two-step polymerization performed in a solvent...
-
Marcin Wekwejt dr inż.
OsobyMarcin Wekwejt, absolwent studiów inżynierskich w inż. biomedycznej (2016; Politechnika Bydgoska im. J. i J. Śniadeckich & Collegium Medicum im. L. Rydygiera), studiów magisterskich w inż. mechaniczno-medycznej (2018; Politechnika Gdańska & Gdański Uniwersytet Medyczny) oraz studiów doktoranckich w dyscyplinie inż. materiałowej (2021, Politechnika Gdańska). Uzyskał z wyróżnieniem stopień naukowy doktora nauk inżynieryjno-technicznych...
-
The Influence of Articular Cartilage Thickness Reduction on Meniscus Biomechanics
PublikacjaObjective Evaluation of the biomechanical interaction between meniscus and cartilage in medial compartment knee osteoarthritis. Methods The finite element method was used to simulate knee joint contact mechanics. Three knee models were created on the basis of knee geometry from the Open Knee project. We reduced the thickness of medial cartilages in the intact knee model by approximately 50% to obtain a medial knee osteoarthritis...
-
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublikacjaWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
ANGLE ORTHODONTIST
Czasopisma -
Antibacterial Activity and Cytocompatibility of Bone Cement Enriched with Antibiotic, Nanosilver, and Nanocopper for Bone Regeneration
PublikacjaBacterial infections due to bone replacement surgeries require modifications of bone cement with antibacterial components. This study aimed to investigate whether the incorporation of gentamicin or nanometals into bone cement may reduce and to what extent bacterial growth without the loss of overall cytocompatibility and adverse effects in vitro. The bone cement Cemex was used as the base material, modified either with gentamicin...
-
Three-Dimensional Printing of Bone Models
PublikacjaThe trabecular bone occurs, for example, in the femoral heads. Understanding the phenomenon of bone tissue degeneration can be the basis for the possibility of looking for alternative methods of surgical treatment of bone loss. The paper presents the results of the trabecular bone model, which was produced in additive manufacturing method with fused filament fabrication technology. The verification of the mechanical behavior of...
-
Development of polyurethanes for bone repair
PublikacjaThe purpose of this paper is to review recent developments on polyurethanes aimed at the design, synthesis, modifications, and biological properties in the field of bone tissue engineering. Different polyurethane systems are presented and discussed in terms of biodegradation, biocompatibility and bioactivity. A comprehensive discussion is provided of the influence of hard to soft segments ratio, catalysts, stiffness and hydrophilicity...
-
High meniscal slope angle as a risk factor for meniscal allograft extrusion
PublikacjaA meniscal graft extrusion is still an unresolved problem that affects most patients after a meniscal transplantation. Despite the advances in surgical techniques, together with the improved methods for a meniscal allograft sizing, success is only observed in up to 75% of patients after they experience a meniscal allograft transplantation. Because a meniscal extrusion is associated with a cartilage deterioration and the progression...
-
Biomechanical properties of 3D-printed bone models
PublikacjaBone lesions resulting from large traumas or cancer resections can be successfully treated by directly using synthetic materials or in combination with tissue engineering methods (hybrid). Synthetic or hybrid materials combined with bone tissue’s natural ability for regeneration and biological adaptation to the directions of loading, allow for full recovery of its biological functions. Increasing interest in new production methods...
-
Drill holes decrease cancellous bone strength: A comparative study of 33 paired osteoporotic human and 9 paired artificial bone samples
PublikacjaThis study was designed to compare compressive strength of cancellous bone retrieved from the femoral head in a specimen with and without guide wire hole, with comparison to synthetic bone samples. Femoral heads retrieved from 33 patients who sustained femoral neck fractures and underwent hip arthroplasty were cut into cuboids leaving two matching samples from the same femoral head. Similar samples were prepared from synthetic femurs....
-
Comparative review of piezoelectric biomaterials approach for bone tissue engineering
PublikacjaBone as a minerals’ reservoir and rigid tissue of the body generating red and white blood cells supports various organs. Although the self-regeneration property of bone, it cannot regenerate spontaneously in severe damages and still remains as a challenging issue. Tissue engineering offers several techniques for regenerating damaged bones, where various biomaterials are examined to fabricate scaffolds for bone repair. Piezoelectric...
-
Analyses of Shear Angle in Orthogonal Cutting of Pine Wood
PublikacjaThe determination of energy effects for wood machining processes, such as cutting power and cutting forces, is very useful in designing of manufacture process of wooden products. A more accurate prediction of cutting forces requires a correct determination of the shear angle value, which can be determined using various models. In this article, shear angle values for an orthogonal linear cutting process of pine wood are determined. The...
-
Antimicrobal and ostheointegration activity of bone cement contains nanometals
PublikacjaPurpose: One of the major problems in bone surgery are infections – especially thoseoccurring in the course of the operating on the patients with lowered immunity system,because they carry the danger of complications. In the Mechanical Department of TechnicalUniversity of Gdansk, there has been carried the research with the use of bone cement andmetal nanoparticles.Design/methodology/approach: The bone cement was used without supplement...
-
The effect of current delay angle on tripping of residual current devices
PublikacjaPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Corrosion degradation of spacers – examination of changes in bone cement coating.
PublikacjaSpacer is a special implant used at the time of infection after endoprosthetic surgery. It consists of a metal core and bone cement coating with an antibiotic. In the human body spacers are exposed to degradation processes. This paper looks at the effect of corrosion on spacers. Electrochemical corrosion tests were performer on titanium pins with bone cement coating in two solutions: Ringer’s solution and artificial...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublikacjaResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Determination of binder-aggregate adhesion by contact angle measurement
PublikacjaThe key factor in asphalt pavement durability, especially in the presence of water, is adhesion of the bituminous binder to mineral aggregates. There are currently no standard laboratory test procedures that can quickly and accurately measure the strength of the interaction (bond) between the binder and aggregate. In this regard, to evaluate the adhesion force measurements based on the contact angle between the binder and the aggregate...
-
ANALYSIS OF BONE WEDGE DIMENSIONS SELECTION METHODS IN HIGH TIBIAL OSTEOTOMY
PublikacjaThe article presents the analysis of methods for selecting dimensions of bone wedge for high tibial osteotomy. The existing methods are described along with the procedure. In the following paragraphs, deficiencies in the selection of bone wedge dimensions and global trends in this field have been demonstrated. Based on the numerical analysis, the problem appearing in the wrong choice of bone wedge imensions was illustrated.
-
Antibacterial evaluation of bioactive modifiers of bone cements: antibiotics, nanometals and chitosan
PublikacjaModern biomaterials in addition to their basic tasks, can serve as carriers of active substance. The release of a bioactive particles allows to locally fight infection or its prevent it. Bone cements additionally to their basic applications in orthopedic surgery can also serve to deliver locally active substances. Currently, only antibiotics are routinely used as modifiers for bone cements. Bioactive bone cements constitute...
-
Effective Friction Angle Of Deltaic Soils In The Vistula Marshlands
PublikacjaThis article presents the results of laboratory tests on soft, normally consolidated soils from the Vistula Marshlands. Samples of high-plasticity organic soils (muds) taken from 3.2–4.0 m and 9.5–10.0 m depth, as well as peat deposit at 14.0 m, are analysed. Presented case study confirms the applicability of the Norwegian Institute of Technology (NTH) method based on Cone Penetration Tests (CPTU) and allows for a conservative...
-
Requirements, modifications and methods of mechanical testing of bone cement – literature review
PublikacjaThe Aim of the paper is to show the basic requirements for the bone cement, its modifications in terms of physical, mechanical and biological properties and testing methods. This publication is intended to be a source of systematized basic knowledge regarding the modified bone cement.
-
Biomechanical testing of bioactive bone cements – a comparison of the impact of modifiers: antibiotics and nanometals
PublikacjaApart from its bone filler and fracture stabilizing function, bone cement can be used as a carrier of bioactive substances, and such modified bone cement can protect the implant against microorganisms, treat local infections and combat bacteria introduced during the surgical procedure. In this paper, the effects of modifying antibiotics and nanosilver on the biomechanical properties of bone cement were examined. The following tests...
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
INFLUENCE OF SURFACE CURVATURE ON SESSILE DROPLET CONTACT ANGLE OF NANOFLUIDS
PublikacjaThis paper deals with change in contact angle of droplets of three nanofluids, i.e. water-Al2O3, water-TiO2 and water-Cu. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. Although dispersants were not used to stabilize the suspension, the solutions tested exhibited satisfactory stability. Ultrasonic vibration was used in order to stabilise the dispersion of the nanoparticles. Experimental measurements...
-
Effect of aeration of antibiotic-loaded bone cement on its properties and bactericidal effectiveness
PublikacjaBACKGROUND: Antibiotic-loaded bone cements are now widely used in medicine. They are able to locally deliver antibiotic particles and they allow treat or protect against infection. It is assumed that the bactericidal effectiveness of bioactive bone cements depend on the parameters of its production. Hence, the aim of this study was to check the effect of aeration of bone cement before mixing the components on its properties as...
-
Green engineered biomaterials for bone repair and regeneration: Printing technologies and fracture analysis
PublikacjaDespite the exceptional self-regeneration properties of bone, severe injuries often require additional surgical intervention such as using artificial bone constructs. These structures need to meet a number of criteria regarding their structure, performance, alongside the rate and the mechanism of erosion and fracture when implanted, for stimulating the regeneration of defected bone and, more critically providing support in the...
-
Tire camber angle influence on tire-pavement noise
PublikacjaTaking into account tire-pavement noise and tires classification with respect to noise emission special measurement methods are usually used. When two of them are applied (the Laboratory Drum Method (DR) and the Close-Proximity Method (CPX)) the investigator has to be sure that the position of the tire is correct. The authors of this paper thought about tire position as tire (wheel) alignment in particular tire camber angle. They...
-
Design of a continuous intra-oral distraction device for mandibular bone
PublikacjaIn this paper we present example of a specific device used for distraction osteogenesis. Distraction osteogenesis (also called callus distraction, collotasis or osteodistraction) is a surgical process for reconstructing bone deformities or lengthening bones.
-
Comment on permeability conditions in finite element simulation of bone fracture healing
PublikacjaThe most popular model of the bone healing considers the fracture callus as poroelastic medium. As such it requires an assumption of the callus’ external permeability. In this work a systematic study of the influence of the permeability of the callus boundary on the simulated bone healing progress is performed. The results show, that these conditions starts to play significant role with the decrease of the callus size. Typically...
-
Biological and mechanical properties of bone cement with nanoparticles - in vivo and in vitro research
PublikacjaDespite antibiotics preventive treatment, before and after an implant implementation, risk of infection are real. These infections at the implant surface develop in a few months after applying them into the body. To prevent the development of bacteria and to reduce the risk of infection, implants coated with nanoparticles come into use. The Mechanical Department of the Technical University of Gdańsk carried out a research with...
-
Young’s modulus distribution in the FEM models of bone tissue
PublikacjaThis paper presents how differences of Young’s modulus in adjacent finite elements typical for organic materials such as bone tissue, influence stress calculating. Emphasizing high computational cost of variable Young’s modulus in parts of the model, where the number of finite elements has been raised, the authors wants to prove that new model of finite element which has variable Young’s modulus in its volume needs to be created....
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
Experiments and numerical modeling of meat and bone meal pyrolysis in a rotary kiln
PublikacjaThe paper presents aspects of modelling the pyrolysis of meat and bone meal (MBM) in a rotary kiln. The pyrolysis of MBM produces a solid fraction which can be used as a fuel, a liquid fraction with potential chemical applications and a low heating value gas. The meat and bone meal pyrolysis was carried out at the temperature of 900 oC. Main features of experiments and numerical model of the pyrolysis were described. The model...
-
SESSILE DROPLET CONTACT ANGLE OF WATER-Al2O3, WATER-TiO2 AND WATER-Cu NANOFLUIDS
PublikacjaThe goal of the present work was the experimental determination of the contact angle of droplets of three nanofluids on various substrates. Of particular interest was effect of nanoparticle concentration on droplet contact angle.
-
Sessile droplet contact angle of water–Al2O3, water–TiO2 and water–Cu nanofluids
PublikacjaThis work presents measurements of the contact angle of sessile droplets for three nanofluids, i.e. water–Al2O3, water–TiO2 and water–Cu. The plates made of glass, anodized aluminium and stainless steel of different roughness served as substrates. Ultrasonic vibration was used for 30–60 min in order to stabilise the dispersion of the nanoparticles. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight....
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublikacjaThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
Effect of the inclination angle of the condenser on the heat transfer coefficient value – experimental study
PublikacjaWhen considering problem of the condensation of the refrigerant in a flow inside channel, one needs to pay attention to the shape of its cross-section, the hydraulic diameter, the channel length as well as the orientation of the channel axis in space (horizontal, vertical, inclined). This paper presents an experimental study concerning the effect of the inclination angle of the condenser with a single coil pipe on the heat transfer...
-
Mathematical approach to design 3D scaffolds for the 3D printable bone implant
PublikacjaThis work demonstrates that an artificial scaffold structure can be designed to exhibit mechanical properties close to the ones of real bone tissue, thus highly reducing the stress-shielding phenomenon. In this study the scan of lumbar vertebra fragment was reproduced to create a numerical 3D model (this model was called the reference bone sample). New nine 3D scaffold samples were designed and their numerical models were created....
-
Influence of concentration on contact angle of water-Cu nanofluid on glass substrate
PublikacjaIn the paper the results of an experimental investigation of influence of nanoparticle concentration on contact angle of water-Cu nanofluid on glass substrate have been presented. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. In the present study copper was applied as nanoparticle while distilled, deionized water was used as a base fluid. The mean diameter of nanoparticle is estimated to be 50...
-
Bone Research
Czasopisma -
Bone Reports
Czasopisma