Wyniki wyszukiwania dla: SPECTROSCOPY MEASUREMENTS
-
Reassesing whole tooth electrical impedance spectroscopy measurements
PublikacjaW pracy dokonano krytycznej oceny wyników wcześniejszych badań spektorskopowych zębów przeprowadzonych w innych ośrodkach i porównano je z własnymi. Wskazano na trudności występujące podczas pomiarów.
-
Three modes of electrochemical impedance spectroscopy measurements performed on vanadium redox flow battery
PublikacjaThis article presents an innovative approach to monitor working redox flow batteries using dynamic electrochemical impedance spectroscopy, diverging from the commonly sequential impedance methods carried out under potentiostatic or galvanostatic conditions close to the open circle voltage. The authors introduce a fresh variation of dynamic impedance measurement that leverages an amplitude-modulated multi-frequency alternating current...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses
Publikacja -
Dynamic elektrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublikacjaDynamiczna elektrochemiczna spektroskopia impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublikacjaDynamiczna Elektrochemiczna Spektroskopia Impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Corrosion rate measurements by non-linear electrochemical impedance spectroscopy
Publikacja -
Optical time of flight spectroscopy for highly scattering materials measurements.
PublikacjaW artykule omówiono możliwości wykorzystania optycznej spektroskopii czasu przelotu w wyznaczaniu podstawowych parametrów optycznych materiałów silnie rozpraszających światło. Wykorzystano tu metodę Monte Carlo i metodę dyfuzji.
-
X-Ray photoemission spectroscopy measurements of the Nb-V-Sr-O ceramics
Dane BadawczeNiobium doped strontium vanadate based perovskite SrV1-xNbxO3-δ materials were prepared via conventional solid state reaction (SSR) method. For comparison, different samples with a various amount of niobium dopant in the structure were synthesized; x = 0; 0,2; 0,5; 0,8 and 1. Samples were sintered by two-steps: first under a pure hydrogen (purity >99.999%)...
-
Electrochemical impedance spectroscopy measurements - conductivity vs. temperature and conductivity vs. oxygen partial pressure - BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Dane BadawczeThe dataset consists of two main catalogs consisting of measurement data: of the electrical conductivity of the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ (BCZYTb) sample as a function of temperature and of the electrical conductivity as a function of oxygen partial pressure (pO2). Measurements as a function of temperature were carried out in dry and wet air (pH2O ~...
-
Maciej Wróbel dr inż.
OsobyReceived PhD from Gdańsk University of Technology in 2019. Research interests involve non-invasive applications of Raman spectroscopy for tissue analysis, specifically blood parameters measurements. Tissue mimicking phantoms, measurement of optical properties (scattering, absorption), as well as other optical sensing methods. Raman spectroscopy and surface-enhanced Raman spectroscopy (SERS) utilized for measurements of biological...
-
Kazimierz Darowicki prof. dr hab. inż.
OsobyStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Tomasz Wąsowicz dr hab.
OsobyAbsolwent Technikum Elektrycznego w Słupsku (1997 rok) oraz Wydziału Matematyki, Fizyki i Informatyki Uniwersytetu Gdańskiego (2002 rok). W 2006 roku obronił dysertację doktorską z fizyki na WMFiI UG. Pracując już w PG, w 2018 roku uzyskał habilitację. W pierwszym okresie prace badawcze Tomasza Wąsowicza miały związek ze spektroskopią atomową wysokiej zdolności rozdzielczej i koncentrowały się na pomiarze i analizie prawdopodobieństw...
-
Applications of Raman spectroscopy for detection of selected substances in tissues
PublikacjaThis dissertation explores the applications of Raman spectroscopy for biological tissue analysis. Basics of Raman and surface-enhanced Raman spectroscopy (SERS) are described, along with an analysis of the literature on biodetection and non-invasive blood analysis with emphasis on glucose detection. Instrumentation for Raman measurements is described. The sources of noise and interferences occurring in biological tissue measurements...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublikacjaNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
PublikacjaThe number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its...
-
Local electrochemical impedance spectroscopy in dynamic mode of galvanic coupling
PublikacjaA novel method that combines local electrochemical impedance spectroscopy and mapping in dynamicmode is proposed. Method was validated over two galvanic couplings, namely zinc/copper and cad-mium/copper. Impedance spectrum response for all measuring points was obtained by means ofsimultaneous implementation of selected range of frequencies. Proposed method allows the measure-ment in a more time-efficient manner, at the same time...
-
Investigation of the Few‐Layer Black Phosphorus Degradation by the Photonic Measurements
PublikacjaFew-layer black phosphorus (FLBP) is a 2D material that gains worldwide interest for its possible applications, mainly in electronics and optoelec-tronics. However, as FLBP is prone to a degradation process under envi-ronmental conditions, there is a need for a monitoring method allowing investigation of its surface quality. Among many techniques, optoelectronic ones have unique advantages of fast response, non-contact, and non-invasive...
-
Photoelectron spectroscopy of brominated derivative of pyrimidine: 2-bromopyrimidine
PublikacjaIn this study the brominated derivative of pyrimidine, 2-bromopyrimidine, was investigated by photoelectron spectroscopy. Outer valence photoelectron spectra recorded at 21.22, 45 and 100 eV photon energy for this compound are presented. The recorded spectra have a higher resolution than that previously reported in the literature. The bromine 3d and 3p edge photoelectron spectra have also been recorded in a photon impact experiment...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublikacjaIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublikacjaThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Paweł Możejko dr hab.
Osoby -
X-Ray Diffraction, Mössbauer Spectroscopy and Magnetoelectric Effect Studies of Multiferroic Bi5Ti3FeO15 Ceramics
PublikacjaBi5Ti3FeO15 ceramics belongs to multiferroic class of materials. In this work it was prepared by solid-state sintering method and investigated by X-ray diffraction, Mössbauer spectroscopy, and magnetoelectric effect measurements. As it was proved by X-ray diffraction studies the single-phase Bi5Ti3FeO15 compound was obtained. The Mössbauer investigations revealed paramagnetic character of the compound at room temperature as well...
-
Investigation of H2:CH4 plasma composition by means of spatially resolved optical spectroscopy
PublikacjaThe system based on spatially resolved optical emission spectroscopy dedicated for in situ diagnostics of plasma assisted CVD processes is presented in this paper. Measurement system coupled with chemical vapour deposition chamber by dedicated fiber-optic paths enables investigation of spatial distribution of species densities (Hx, H+, CH, CH+) during chemical vapour deposition process. Experiments were performed for a various...
-
Application of the near-infrared spectroscopy in the pharmaceutical technology
PublikacjaNear-infrared (NIR) spectroscopy is currently the fastest-growing and the most versatile analytical method not only in the pharmaceutical sciences but also in the industry. This review focuses on recent NIR applications in the pharmaceutical technology. This article covers monitoring, by NIR, of many manufacturing processes, such as granulation, mixing or drying, in order to determine the end-point of these processes. In this...
-
Optical measurements of LTO:Cu sol-gel derived thin films
Dane BadawczeLithium titanate doped by copper thin films were manufactured by chemical, sol-gel method. Flms were deposited on a Corning glass substrated by spin coater. To calculated optical band gap and other optcal parameters, UV-VIS spectroscopy measurements were performed. For measurements selected samples with various content of Cu.
-
Measurement system for nonlinear surface spectroscopy by atomic force microscopy for corrosion processes monitoring
PublikacjaIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is especially useful for heterogeneous...
-
EDAX file presenting the composition of the SS316L wick structure
Dane BadawczeEnergy Dispersive X-ray Spectroscopy (EDX) measurements facilitate the determination of the chemical composition of each atom within the SS316L structure
-
Noise and Electro-Ultrasonic Spectroscopy of Conducting PolymerThick Films
PublikacjaThick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On the conducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublikacjaThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
Study of Direct Methanol Fuel Cell Process Dynamics Using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaA new technique, which was developed to characterize the direct methanol fuel cell under work conditions, has been presented in this paper. The impedance measurements were made using dynamic electrochemical impedance spectroscopy research technique in the galvanostatic mode, using multiple sinusoidal excitation. Obtained results show, that together with an increase of the temperature and working load, the global impedance...
-
Characterization of metabolites in different kiwifruit varieties by NMR and fluorescence spectroscopy
PublikacjaIt is known from our previous studies that kiwifruits, which are used in common human diet, have preventive properties of coronary artery disease. This study describes a combination of 1H NMR spectroscopy, multivariate data analyses and fluorescence measurements in differentiating of some kiwifruit varieties, their quenching and antioxidant properties. A total of 41 metabolites were identified by comparing with literature data...
-
Stability of borophene dispersion in water
Dane BadawczeThis dataset contains the results of the studies of stability of borophene dispersion in water (1 µg/µL) based on the measurements of absorbance of the solution using UV-VIS spectroscopy.
-
Electrochemical data for carbonized metal-organic framworks with cobalt
Dane BadawczeThe data includes the Metal-Organic Frameworks (MOF) measurements, where cobalt was added. The research focuses on the impact of aluminium on Oxygen Evolution Reaction (OER). The measurements were conducted on [EC Lab]. The techniques included are Linear Sweep Voltammetry (LSV), Tafel slope, Chronopotentiometry (CP) and Electrochemical Impedance Spectroscopy...
-
Determination of pitting corrosion stage of stainless steel by galvanodynamic impedance spectroscopy
PublikacjaThis paper investigates the methodology for differentiation of multistep process of pitting corrosion of AISI 304 stainless steel in the environment of iron (III) chloride. Measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Application of this methodology allowed monitoring of natural corrosion process without external current (IDC = 0A) nor potential perturbation of the system. Applied...
-
Influence of Sn and Pb Ions Substitutions on Dielectric Properties of Barium Titanate
PublikacjaThe results of the microstructural and dielectric measurements of (Ba1-xPbx)(Ti1-xSnx)O3 (BPTSx) (x = 0, 0.05, 0.10, 0.30) polycrystalline samples are presented. The samples were obtained by means of a high temperature synthesis and their expected stoichiometry was confirmed by energy dispersive spectroscopy (EDS) measurements. The dielectric properties of BPTSx were studied with the use of broadband dielectric spectroscopy. The...
-
In-situ and ex-situ resistance measurements of polypyrrole film using double-band electrode
PublikacjaMany in-situ techniques are performed in order to determine the resistance of conducting polymer film. However, the resistance measured in solution can be the combination of polymer resistance and that of other components, such as resistance of supporting electrolyte. Therefore, in this work, the influence of the solution on the resistance of polypyrrole (PPy) film has been studied. PPy film was electrchemically synthesized onto...
-
Mössbauer Spectroscopy and Magnetoelectric Effect Studies of Multiferroic Ceramics Based on BiFeO<sub>3</sub>
PublikacjaIn this work the results of investigations for (BiFeO3)x(BaTiO3)1-x and Bi1-xNdxFeO3 solid solutions are described. Samples were prepared by the conventional solid-state sintering method. X-ray diffraction, 57Fe Mössbauer spectroscopy, and magnetoelectric effect measurements were applied as complementary methods to determine the structure and magnetic properties of materials. For (BiFeO3)x(BaTiO3)1-x solid solutions Mössbauer...
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublikacjaThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Electrical and mechanical characterization of two-phase alloys by means of scanning probe microscopy in dynamic impedance spectroscopy mode
PublikacjaDynamic impedance spectroscopy, evaluated for measuring non-stationary systems, was used in combination with scanning probe microscope. Using this approach, localized impedance measurements in the AFM contact mode could be carried out. Additionally, impedance–force curves were made at each phase of investigated materials to illustrate the relation between impedance and the force applied to a probe. Therefore, correlation of electrical...
-
Application of quartz crystal microbalance and dynamic impedance spectroscopy to the study of copper corrosion inhibitors
PublikacjaThe study investigates the application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) and Electrochemical Quartz Crystal Microbalance (EQCM) techniques to examine the corrosion inhibition of copper by Benzotriazole and Sodium Folate in a 0.1 M NaCl solution. DEIS, an advanced version of Electrochemical Impedance Spectroscopy (EIS), allows for real-time monitoring of non-stationary electrochemical systems,...
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublikacjaIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Structure and optical measurements of Eu doped tellurium oxide thin films
Dane BadawczeThin films were deposited by magnetron sputtering method and simultaneously heated at 200 oC. Presence of Eu ions and their valence states was confirmed by X-ray photoemission spectroscopy measurements. The structure of the films as well as the influence of europium dopant on crystalline structure of the films was examined by X-ray diffraction method. ...
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Localized impedance measurements of AA2024 and AA2024-T3 performed by means of AFM in contact mode
PublikacjaPurpose: The purpose of this paper is to present the results of an atomic force microscopy (AFM) based approach to local impedance spectroscopy (LIS) measurement performed on AA2024 and AA2024-T3 aluminium alloys. Design/methodology/approach: AFM-LIS measurements were performed ex-situ without the electrolyte environment, so in fact the electrical not electrochemical impedance was obtained. Findings: Relative local impedance values...
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a Tool for Analyzing Surface Oxidation Processes on Boron-Doped Diamond Electrodes
PublikacjaSurface oxidation processes play a key role in understanding electrochemical properties of boron-doped diamond (BDD) electrodes. The type of surface termination groups, which create the potential window of electrolytic water stability or hydrophobicity, influences such properties. In this study the kinetics of oxidation process under anodic polarization were studied in situ by means of Dynamic Electrochemical Impedance Spectroscopy...
-
Study of the Layer-Type BST Thin Film with X-ray Diffraction and X-ray Photoelectron Spectroscopy
PublikacjaIn the present paper, results of X-ray photoelectron studies of electroceramic thin films of barium strontium titanate, Ba1xSrxTiO3 (BST), composition deposited on stainless-steel substrates are presented. The thin films were prepared by the sol-gel method. A spin-coating deposition of BST layers with different chemical compositions was utilized so the layer-type structure of (0-2) connectivity was formed. After the deposition,...
-
Dynamic Electrochemical Impedance Spectroscopy in Galvanostatic Mode as a Tool for Passive Layer State Monitoring in a Chloride Solution Under a Mechanical Load
PublikacjaMechanical stress is one of the factors influencing the initiation of pitting corrosion and deterioration of the protective properties of the passive layer on stainless steel. The tests carried out on AISI 304L stainless steel showed that, in the 3.5% NaCl environment for samples loaded in the elastic and plastic range, no pitting corrosion initiation was observed. Only mechanical damage of the passive layer occurred. Galvanodynamic...
-
Effect of cobalt addition on the corrosion behaviorof near equiatomic NiTi shape memory alloy in normal saline solution: electrochemical and XPS studies
PublikacjaThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC employing various electrochemical methods. These include: linear polarization resistance (LPR), linear sweep voltammetry (LSV), chronoamperometry and dynamic electrochemical impedance spectroscopy...