Filtry
wszystkich: 1441
-
Katalog
- Publikacje 1176 wyników po odfiltrowaniu
- Czasopisma 4 wyników po odfiltrowaniu
- Osoby 19 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 2 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 236 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: ion-selective electrode
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublikacjaA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
PublikacjaIn potentiometry, high selectivity of the ion-selective membranes must be assured in order to reliably measure various analytes in clinical, industrial and environmental samples. Due to the toxic nature of lead(II) it is important to monitor Pb2+ distribution in natural waters. This may be achieved by implementation of ion-selective electrodes (ISEs) with high selectivity towards lead(II) and low detection limit. A great number...
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
Publikacja -
Comparison of Fluoride Ion-Selective Electrode Based Potentiometric Methods of Fluoride Determination in Human Urine
Publikacja -
Equilibration Time of Solid Contact Ion-Selective Electrodes
Publikacja -
Kinetic Description of the Membrane–Solution Interface for Ion-Selective Electrodes
Publikacja -
Poly(3-octylthiophene) as solid contact for ion-selective electrodes: contradictions and possibilities
Publikacja -
Ion-selective electrodes based on p-tert-butyl-homooxacalixarene di(ethyl) amides
PublikacjaPochodne dietyloamidowe p-tert-butylodihomooksakaliks[4]arenu (1), p-tert-butyloheksahomotrioksakaliks[3]arenu (2) oraz p-tert-butylokaliks[4]arenu (3) były wykorzystane jako materiał aktywny w membranach elektrod jonoselektywnych w celu sprawdzenia detekcji kationów różnych rodzajów (Na+, K+, Cs+, Mg2+, Ca2+, Mn2+, Cu2+, Zn2+, Cd2+, Pb2+ oraz kation tetrametyloammoniowy). Wyznaczono charakterystyki elektrod oraz współczynniki...
-
Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective Electrodes
Publikacja -
Ion-selective electrodes based on p-tert-butyl-homooxacalixarene di(ethyl)amides
Publikacja -
A new phosphonium calix[4]arene for selective anion recognition: synthesis and studies in solution and in ion selective electrodes
PublikacjaZaprezentowana została synteza i charakteryzacja tetra (trifenylofosfoniowego) p-tert-butylkaliks[4]arenu 2. Oddziaływania z anionami były badane z użyciem (1)H oraz (31)P NMR i spektrofotometrii absorpcyjnej UV. Badania wykazały oddziaływania z anionami: CLO4-, I-, oraz SCN-. Selektywność jonoforu 2 badano również w membranowych elektrodach jonoselektywnych (ISE) PCV/o-NPOE. Elektroda zawierająca związek 2 generuje odpowiedź potencjometryczną...
-
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublikacjaThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...
-
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
Publikacja -
Solid-Contact Ion-Selective Electrodes with Highly Selective Thioamide Derivatives of p-tert-Butylcalix[4]arene for the Determination of Lead(II) in Environmental Samples
Publikacja -
Potentiometric sensor containing set of ion selective electrodes with lipid modified membranes for quality assessment of tested non-alcoholic beverages
PublikacjaPotentiometric sensors may be a good tool for fast quality control of commercial drinks. In this work, such a sensor, containing a set of ion-selective electrodes with lipid-modified membranes (benzylhexadecyldimethylammonium chloride monohydrate, hexadecylamine, 1-dodecanol, elaidic acid, cholesterol) was used for discrimination and quality control of non-alcoholic beverages, mainly composed of sugar and citric acid. It was found...
-
Solid-Contact Ion-Selective Electrodes with Highly SelectiveThioamide Derivatives of p-tert-Butylcalix[4]arene for theDetermination of Lead(II) in Environmental Samples
PublikacjaThioamide derivatives of p-tert-butylcalix[4]arene were used as ionophores in the development of solid-contact ion-selective electrodes based on conducting polymer poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) which was synthesized by electrodeposition on the glassy carbon electrodes. The typical ion-selective membranes with optionally two different plasticizers [bis(2-ethylhexyl)sebacate (DOS) and 2-nitrophenyl...
-
Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo-15-crown-5) derivatives
PublikacjaGlassy carbon electrodes modified by conductive polymers and membrane with derivatives of bis(benzo-15-crown-5) were tested as solid contact ion selective electrodes for K+ ions concentration determination. PEDOT with PSS, Cl- and ClO4- counter ions was electrochemically deposited onto glassy carbon substrates using four different electrochemical approaches (potentiostatic, galvanostatic, potentiodynamic and potentiostatic pulses)....
-
Pyrrole azocrown ethers. Synthesis, complexation, selective lead transport and ion-selective membrane electrode studies
PublikacjaOtrzymano nowe, 21-członowe, lipofilowe etery koronowe z jednostką pirolową i dwoma grupami azowymi jako składowymi makrocyklu. Właściwości kompleksujące tych nowych oraz dwóch wcześniej otrzymanych makrocykli zbadano w acetonitrylu. Ligandy te zostały użyte jako jonofory w badaniach konkurencyjnego transportu równomolowej mieszaniny jonów metali: Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Ag2+, Pb2+ w układzie woda(pH 4.9)/chloroform/woda(pH...
-
Lower Rim Substitutedp-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based onp-tert-Butyl-calix[4]arene Thioamides
Publikacja -
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based on p-tert-Butyl-calix[4]arene Thioamides.
PublikacjaTetra podstawione tioamidowe pochodne para-tert-butylokaliks[4]arenu (1-5) zostały zastosowane jako jonofory w membranowych elektrodach jonoselektywnych (EJS) selektywne na kationy Pb(II). Wyznaczono współczynniki selektywności. Czwartorzędowe kaliks[4]aren-tioamidy (1,2) wykazują nadzwyczaj dobrą selektywność na kationy Pb(II) w porównaniu z kaliks[4]aren-amidami. Membrany z tymi ligandami wykazują dużą trwałość, a charakterystyki...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublikacjaLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Studies on 16-membered azothia-and azoxythiacrown ethers as ion carriers in ion selective membranes.
Publikacja16-członowe azo iazoksy korony zawierające w makropierścieniu atomy siarki były badane jako nośniki jonów w jonoselektywnych elektrodach membranowych. Związki te badane były pod kątem kompleksowania metali I i II grupy układu okresowego oraz metali ciężkich i przejściowych. Wyznaczone zostały stałe trwałości kompleksów azokoron z wybranymi kationami za pomocą metody sandwiczowej. W wyniku badań potwierdzono tworzenie się silnych...
-
Ionophores in polymeric membranes for selective ion recognition:impedance studies
PublikacjaW pracy badano dwa typy elektrod: membranowe elektrody jonoselektywne (ISE) oraz elektrody nowego typu all-solid-state (AAS). Elektrody AAS zawierają przewodzącą warstwę polimerową na węglu szklistym lub platynie, na który nałożona jest membrana zawierająca jonofor. Do badań użyto dwa jonofory: p-tert-butylokaliks[4]aren-korona-4 (L1) selektywnie kompleksująca jony Na+ oraz kaliks[4]aren-korona-6 (L2) selektywnie kompleksująca...
-
Ionophores in polymeric membranes for selective ion recognition; impedance studies
PublikacjaBadania impedancyjne membran zawierających jonofory selektywne na kation Na+ (L1) i Cs+(L2) wykazały, ze stala dielektryczna materiału membrany zależy od typu uzytego plastyfikatora i zmienia się w zakresie od 28 do 60. Rezystancja membran zawierających ligand L1 i L2 wynosi 0.15 -1.4 Mohm w zależności od stężenia elektrolitu zewnnetrznego. Testowona dwa typy elektrod jonoselektywnych: elektrody typu ASS z polimerem przewodzącym...
-
Digital harmonic analysis of cadmium ion reduction on a dropping mercury electrode
PublikacjaBadano redukcję jonów kadmu na rtęciowej elektrodzie kroplowej. Jako pobudzenie zastosowano sinusoidalny sygnał napięciowy nałożony na liniowo zmieniający się potencjał dc. Przeprowadzono analizę czasowo-częstotliwościową prądu polarograficznego dla reakcji redukcji jonu kadmu na rtęciowej elektrodzie kroplowej. Klasyczna transformacja Fouriera prowadzi do dekompozycji prądu polarograficznego na składowe harmoniczne. Harmoniczne...
-
Tin Oxide Encapsulated into Pyrolyzed Chitosan as a Negative Electrode for Lithium Ion Batteries
PublikacjaTin oxide is one of the most promising electrode materials as a negative electrode for lithium-ion batteries due to its higher theoretical specific capacity than graphite. However, it suffers lack of stability due to volume changes and low electrical conductivity while cycling. To overcome these issues, a new composite consisting of SnO2 and carbonaceous matrix was fabricated. Naturally abundant and renewable chitosan was chosen...
-
Solid-phase microextraction and ion chromatographic analysis of anions based on polypyrrole electrode
Publikacja -
Synthesis and application of tetrazole di and triamide derivatives in ion-selective membrane electrodes
PublikacjaA number of tetrazole diamides and triamides have been synthesized and applied as ion carries in ion-selective membrane electrodes. Their selectivity and sensitivity were studied towards alkali, alkaline earth, transition and heavy metal cations. it was found that membranes doped with 3 and 2-nitrophenyl octyl ether exhibit an almost theoretial Nernstian response for NH+ over relatively wide concentration range. Elestrodes with...
-
Carbon nanotubes decorated by mesoporous cobalt oxide as electrode material for lithium-ion batteries
Publikacja -
Selective Synthesis of Magnetite Nanospheres with Controllable Morphologies on CNTs and Application to Lithium‐Ion Batteries
Publikacja -
Poly(hydroxybutyrate-co-hydroxyvalerate) as a biodegradable binder in a negative electrode material for lithium-ion batteries
PublikacjaIn this work, graphite-based negative electrode for lithium-ion battery consisting a novel and biodegradable binder poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is compared with standard graphite electrode with polyvinylidene fluoride (PVDF) as a binder. The rate and cycling performance of lithium ion insertion/extraction of electrodes with PHBV in a half-cell configuration are evaluated. Moreover, on the basis of the electrochemical...
-
Experimental and computational analysis of SnSx encapsulated into carbonized chitosan as electrode material for potassium ion batteries
PublikacjaTin sulphide compounds (SnSx, x = 1, 2) are potential anode materials for potassium-ion batteries (PIBs) due to their characteristic layered structure, high theoretical capacity, non-toxicity and low production cost. However, they suffer from significant volume changes resulting in poor performance of such anodes. In this work incorporation of SnSx into the carbon structure was expected to overcome these disadvantages. Two SnS-based...
-
Towards Promotion of Graphene/Titania‐Based Electrode via Ultrafast and Self‐Expansion Reduction for Li‐ion Battery
Publikacja -
Tin oxide nanoparticles from laser ablation encapsulated in a carbonaceous matrix – a negative electrode in lithium-ion battery applications
PublikacjaThis report concerns carbonaceous electrodes doped with tin(II) oxide nanoparticles. Tin nanoparticles are obtained by pulsed laser ablation in water. Crystalline nanoparticles have been encapsulated in a carbonaceous matrix formed after pyrolysis of a mixture consisting of tin/tin(IV) oxide nanoparticles and gelatine. The obtained material is characterized by means of X-ray diffraction, selected area diffraction, scanning electron...
-
Dipodal Tetraamide Derivatives of 1,10-Diaza-18-Crown-6 and Alkylmalonic Acids—Synthesis and Use as Ionophores in Ion Selective Membrane Electrodes
PublikacjaNovel dipodal derivatives of an 18-membered diaza-crown ether with two diamide chains featuring methylmalonic or butylmalonic acid residues were obtained and tested as ionophores in ion-selective plasticized membrane electrodes. The objective of the study was to identify measurement conditions which ensure the most favorable performance for magnesium ion-selective electrodes. The relationship between the molar lipophilic anion...
-
Lower rim substituted tert-Butylcalix[4]arenes. Part 13. Interaction of calix-hydroxamates with Fe(III) and Pb(II); studies in ion-selective membrane electrodes (ISE)
PublikacjaPrzedmiotem pracy są badania oddziaływań pomiędzy trzema wybranymi hydroksamowymi pochodnymi t-butylo-kaliks[4]arenu i jonami metali z wykorzystaniem membranowych elektrod jonoselektywnych (ISE). Elektrody zawierające jako materiał aktywny wymienione związki jonoforowe charakteryzują się nernstowskim nachyleniem i szerokim zakresem liniowości na jony Pb(II), a także dobrą selektywnością na jony Pb(II)w stosunku do jonów UO2(II),...
-
Lower Rim Substituted p-tert-Butyl Calix[4]arenes(V). Synthesis of New 5,11,17,22-tetrakis-p-tert-Butyl-25-27-bis(dialkoxyphosphorylmethoxy)calix[4] arenes and Cation Complexation Studies in Ion Selective Membrane Electrodes.
PublikacjaZaprezentowano syntezę i właściwości trzech nowych związków (2-4), bis podstawionych na dolnym obrzeżu grupami z resztą fosforylową. Związki te były badane jako jonofory w membranowych elektrodach jonoselektywnych (ISE) wykazując selektywność na kationy Rb+,K+ oraz duży i płaski kation guanidyniowyG+). Badano korelację pomiędzy stereo-strukturą związków a ich selektywnością w ISE. Stałe trwałości kompleksów z kationami metali...
-
Simultaneous determination of Na+, K+, Ca2+, Mg2+ and Cl- in unstimulated and stimulated human saliva using all solid state multisensor platform
PublikacjaHuman saliva is one of the body fluids which collection method is relatively simple and non-invasive. The article is dedicated to assess concentration (activity) of Na+, K+, Ca2+, Mg2+ and Cl- in fresh, unstimulated or stimulated human saliva samples using single solid contact ion-selective electrodes with conventional reference electrode and self-made multisensor platform (MP) equipped with ion-selective membranes for Na+, K+,...
-
Anna Lisowska-Oleksiak prof. dr hab.
OsobyAnna Lisowska-Oleksiak, born in 1952, has been working at GUT since 1977. Currently is employed at the Faculty of Chemistry as a full professor. She was employed as a research assistant at the University of St Andrews in the group of C. A. Vincent and P.G. Bruce (1991-1994). She completed a two-month research internship in CEA Grenoble (2011). Anna Lisowska-Oleksiak obtained her MSc in chemistry at Nicolaus Copernicus University...
-
Monika Wilamowska-Zawłocka dr hab. inż.
OsobyDr hab. inż. Monika WILAMOWSKA-ZAWŁOCKA jest absolwentką Wydziału Chemicznego Politechniki Gdańskiej. Studia doktoranckie ukończyła w 2011 r., następnie odbyła roczny staż na Technicznym Uniwersytecie w Darmstadt w Niemczech. Pracuje w Politechnice Gdańskiej od 2013 r., od 2019 r. na stanowisku profesora uczelni. Specjalność –materiały elektrodowe w zastosowaniu do ogniw litowo-jonowych, sodowo-jonowych, kondensatorów elektrochemicznych...
-
O-substituted tetrahydroxamate derivatives of p-tert-butylcalix[4]arene as receptors for transition and heavy metal cations
PublikacjaTetrasubstituted O-hydroxamate derivatives of p-tert-butylcalix[4]arene were applied as active materials in ion-selective membrane electrodes and were tested towards Pb-selectivity. The electrodes gave near-Nernstian characteristics for Pb2+ cations. The selectivity coefficients were determined. The influence of plasticizer on the electrode behaviour was studied. The dependence of the chemical structure on selectivity coefficients...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublikacjaThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
Jarosław Chojnacki prof. dr hab. inż.
OsobyUrodzony w 1961 w Bydgoszczy, absolwent Technikum Chemicznego im. I. Łukasiewicza w Bydgoszczy. Studia chemiczne ukończył na Wydziale Chemicznym Politechniki Gdańskiej w 1986 roku, broniąc pracy dotyczącej elektrod jonoselektywnych. Późniejsze badania związane były z syntezą organiczną i krzemoorganiczną a od 2002 roku z krystalografią. Praca doktorska dotyczyła silanotiolanów miedziowców, a dysertacja habilitacyjna (2010) opisywała...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublikacjaThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublikacjaGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Selective detection of F- by chromogenic tetrazole receptor
PublikacjaA chromogenic anion host 4, containing two amide functionalities linked to azo dye and tetrazole rings was synthesized and its complexes with various anions were investigated. The results show that receptor 4 can recognize selectively biologically important F- ion. The binding affinity for F- was investigated by naked-eye colour change, UV-Vis and 1H NMR spectroscopy. Addition F- ion in CH3CN and DMSO to receptor 4 cause a colour...
-
Chromogenic derivatives of new bis(phenylhydrazono-1H-tetrazol-5-yl-acetonitriles) - synthesis and properties
PublikacjaDerivatives of bis(phenylhydrazono-1H-tetrazol-5-yl-acetonitriles) with oxygen and sulphur atoms in the structure of aliphatic chains were successfully synthesised. The correlation between the ligand structure and its complexation properties was investigated by absorption spectroscopy. The formation of complexes of presented compounds with metal cations (Cu2+, Ni2+, Zn2+, Co2+, Fe2+ and Pb2+) was studied. Ligands 5-8 were additionally...
-
Electrochemical Activity of Electrode Material Consisting of Porous Copper and Silica Aerogel
PublikacjaElectrochemically obtained copper was combined with silica aerogel (SiO2ag). Obtained composite (SiO2@Cu/CuxOy) was tested as an electrode in contact with LiPF6 in EC/DMC electrolyte. The electrochemical measurements showed the presence of complex redox couple activities of SiO2@Cu/CuxOy. This experiment was employed to help in understanding the carbon role used as an electric contact for silica in Li-Ion batteries and clarify...
-
Functionalized azobenzocrown ethers as sensor materials—The synthesis and ion binding properties
PublikacjaNew 13- and 16-membered azobenzocrown ethers with aromatic amino, amide, ether–ester or ether–amide residue in para position to an azo moiety were obtained. Acid–base properties and ion binding ability of the colored compounds were studied by spectroscopic methods: UV–vis, fluorimetry and 1H NMR spectroscopy. Selected azobenzocrowns were tested as ionophores in ion-selective membrane electrodes (ISEs) – classic and miniature all...
-
Azomacrocyclic derivatives of imidazole: synthesis, structure, and metal ion complexation properties
PublikacjaNew azocrown ethers comprising imidazoles in the macrocycle have been synthesized. Imidazole, 2-methyl-, 4-methyl-, and 4-phenylimidazole were incorporated to form macrocyclic units by coupling with the appropriate bis-diazonium salts. The syntheseswere performed under high dilution conditions. The X-ray structure of a water adduct of the 21-membered crown ether derivative of 4-methylimidazole 8 has been solved. Metal...