Filtry
wszystkich: 5028
-
Katalog
- Publikacje 3435 wyników po odfiltrowaniu
- Czasopisma 91 wyników po odfiltrowaniu
- Konferencje 10 wyników po odfiltrowaniu
- Osoby 681 wyników po odfiltrowaniu
- Wynalazki 2 wyników po odfiltrowaniu
- Projekty 7 wyników po odfiltrowaniu
- Laboratoria 1 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 179 wyników po odfiltrowaniu
- Wydarzenia 14 wyników po odfiltrowaniu
- Oferty 1 wyników po odfiltrowaniu
- Dane Badawcze 606 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: EHD DEVICE
-
Wideband crossover structure with double ring resonators
PublikacjaThe structure of a four-port microstrip crossover is presented. The device is composed of two ring resonators, one circular and one built from meander lines, connected by four straight lines. The equivalent circuit model of the crossover is derived. The structure is designed on thin and flexible substrate to allow it to bend. The possibility of applying the device on curved surfaces is tested experimentally.
-
Magnetic field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz – selective detection
Dane BadawczeThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
Design and Evaluation of the Platform for Weight-Shifting Exercises with Compensatory Forces Monitoring
PublikacjaDetails of a platform for the rehabilitation of people with severe balance impairment are discussed in the paper. Based upon a commercially available static parapodium, modified to fit force sensors, this device is designed to give a new, safe tool to physiotherapists. It is designed for the patients who cannot maintain equilibrium during a bipedal stance and need to hold to or lean on something during the rehabilitation. Visual,...
-
Scientific Journal of University of Szczecin "Service Management"
Czasopisma -
Human Factors and Ergonomics in Manufacturing & Service Industries
Czasopisma -
Marcin Golebiewski PhD
Osoby -
Padvsa Bollettino del Centro Polesano di studi storici, archeologici ed etnografici
Czasopisma -
Marek Rocki dr hab
OsobyBorned in Warsaw in 1953, graduated in 1970 in econometrics at Main School of Planning and Statistics. Since 1981 employed in the Main School of Planning and Statistics later Warsaw School of Economics (WSE) in the Unit of Econometry in Collegium of Economic Analysis. Was in the Warsaw School of Economics elected for Vice-Rector in 1990 and 1993, for Dean of Graduate Studies in 1996, for Rector in 1999 and 2002, for Dean of Collegium...
-
Urządzenia Peryferyjne - 22/23
Kursy OnlineUP/PD 2023 {mlang pl}Przedmiot Urządzenia Peryferyjne i jego angielska wersja Peripheral Devices przeznaczony jest dla studentów II stopnia na specjalności Komputerowe Systemy Elektroniczne (Computer Electronic Systems). Tematem przedmiotu są różnorodne zagadnienia dotyczące urządzeń peryferyjnych systemów komputerowych, głównie umożliwiających komunikację człowiek-komputer, oraz ich prototypowanie i podstawowe podzespoły.{mlang} {mlang...
-
Urządzenia Peryferyjne 2023/24
Kursy OnlineUP/PD 2023 {mlang pl}Przedmiot Urządzenia Peryferyjne i jego angielska wersja Peripheral Devices przeznaczony jest dla studentów II stopnia na specjalności Komputerowe Systemy Elektroniczne (Computer Electronic Systems). Tematem przedmiotu są różnorodne zagadnienia dotyczące urządzeń peryferyjnych systemów komputerowych, głównie umożliwiających komunikację człowiek-komputer, oraz ich prototypowanie i podstawowe podzespoły.{mlang} {mlang...
-
Low frequency noise measurements in advanced silocon devices.**2003, 136 s.116 rys. bibliogr. 29 poz. maszyn. Pomiary małoczęstotliwościowych szumów zaawansowanych elementów krzemowych. Rozprawa doktorska /15.04.2003./ Inst. Natl. P. Grenoble Promotorzy: prof. dr hab. inż. L. Spiralski, dr CNRS G. Ghibaudo.
PublikacjaW pracy przedstawiono automatyczny system do pomiarów małoczęstotliwoscio-wych szumów struktur elementów półprzewodnikowych. System umożliwia automa-tyczne wyznaczanie charakterystyk stałoprądowych badanego elementu, pomiarszumów i wyznaczanie gęstości widmowej mocy w zadanym zakresie polaryzacji.Przytoczono wyniki przeprowadzonych testów systemu. Ważną składową pracy wy-niki pomiarów szumów tranzystorów MOS i bipolarnych...
-
Credibility of Threats to Jam Anonymous Traffic Remapping Attacks in Ad Hoc WLANs
PublikacjaIn ad hoc networks, selfish stations can pursue a better quality of service (QoS) by performing traffic remapping attacks (TRAs), i.e., by falsely assigning their traffic to a higher priority class, which can hurt honest stations’ QoS. To discourage the attackers, honest stations can announce their dissatisfaction with the perceived QoS. If such a threat fails, a costly data frame jamming defense can be launched. We analyze the...
-
Application Isssues of the Semi-Markov Reliability Model
PublikacjaPredicting the reliability of marine internal combustion engines, for instance, is of particular importance, as it makes it possible to predict their future reliability states based on the information on the past states. Correct reliability prediction is a complex process which consists in processing empirical results obtained from operating practice, complemented by analytical considerations. The process of technical state changes...
-
Microstrip four-port circulator using a ferrite coupled line section
PublikacjaThis paper describes an alternative configuration of a four-port circulator realized in a microstrip ferrite coupled line technology. The proposed fully planar device employs two three-port circulators consisting of a ferrite coupled line junction and T junction. Both circulators are connected through the same arm, hence, the problem of anti-parallel magnetization met in this type of circulators is avoided without the increase...
-
Experimental investigations and simulations of the microturbine unit with permanent magnet generator
PublikacjaIn dispersed power generation, low power devices are used for local combined generating of heat end electric power. There are developing concepts of micropower plants with electric generators driven by steam or gas microturbines. The paper presents the results of an experimental investigations of the microturbine set consists of the turbine with partial admission, permanent magnet generator and three phase AC-to-DC rectifier. The...
-
High-efficiency mini and micro heat exchangers for dispersed power generation
PublikacjaTaking into account the dispersed systems technologies and their development, the ORC systems seem to be promising technology amongst various micro-CHP domestic units (electrical power production below 10 kWe), however practical realization of the ORC cycle in a micro-scale is technically challenging. The system consists in devices such as the vapour generation unit (boiler), expansion device and heat exchangers. Each of them should...
-
Oznaczanie tlenu – od metody Winklera do czujników enzymatycznych (Determination of oxygen – from Winkler Method to enzymatic sensor)
PublikacjaMonitoring of dioxygen levels is of utmost importance from the view-point of life processes, medical diagnostics, nutrition and chemical industries. In all these measurements both low and high levels of this element are important. The common methods for the determination of dioxygen are the Winkler method, Clark electrode and pulsoxymeters. A new, already strong field of research can be now recognized – the development of miniaturized...
-
Instrument detection and pose estimation with rigid part mixtures model in video-assisted surgeries
PublikacjaLocalizing instrument parts in video-assisted surgeries is an attractive and open computer vision problem. A working algorithm would immediately find applications in computer-aided interventions in the operating theater. Knowing the location of tool parts could help virtually augment visual faculty of surgeons, assess skills of novice surgeons, and increase autonomy of surgical robots. A surgical tool varies in appearance due to...
-
Mikropompa elektrohydrodynamiczna na ciecz dielektryczną zasilana napięciem stałym
PublikacjaW niniejszym artykule zaprezentowano projekt i działanie miniaturowej pompy elektrohydrodynamicznej (EHD) zasilanej napięciem stałym przeznaczonej do chłodzenia elementów elektronicznych. Zmierzono natężenie przepływu cieczy oraz ciśnienie wytwarzane przez pracującą mikropompę. Maksymalne natężenie przepływu, 0,5 ml/min, uzyskano dla napięcia 12 kV. Zmierzone ciśnienie wyniosło 500 Pa przy przyłożonym napięciu 6 kV. Maksymalny...
-
Revsable framework for telecontrol protocols. W: Springer Homepage [online] Proceedings. Second International ESPRIT ARES Workshop on Development and Evolution of Software Architectures for Product Families. Las Palmas de Gran Canaria, Spain, February 26-27, 1998. [Dostęp: 20 grudnia**2002]. Ed. F. van der Linden. Dostępny w World Wide Web: http://link.springer.de/link/ /service/series/0558/tocs/t1429.htm [s. 6-13, 5 rys. bibliogr. 6 poz.] Wzorce wielokrotnego wykorzystania oprogramowania protokołów telesterowa- nia.
PublikacjaZaprezentowano wzorzec COMSOFT wielokrotnego wykorzystania oprogramowania o-pracowany dla protokołów telesterowania. Jego podstawy tworzą: metodologiaobiektowa i wzorce wielokrotnego użycia. Zastosowanie wzorców wspomagają:biblioteka komponentów, wykorzystywanych we wszystkich fazach konstrukcji o-programowania oraz procedury użytkowania i parametryzacji. Opracowane wzorcezostały praktycznie zastosowane do konstrukcji oprogramowania...
-
A multi-agent method for periodicity detection in distributed events
PublikacjaMulti-agent systems working in constantly changing environments may be challenged by instantaneous unavailability of their autonomous agents caused e.g. by limited computing resources. A new method of self-organization of distributed service components is proposed, suitable for multi-agent systems. This method relies on particular agents carrying out separate analyzes of their individual processing loads or other specific events....
-
Moving Towards Competence in Teaching Architecture: The Relationship of Research and Design in Academia
PublikacjaArchitecture is truly a profession of public trust requiring special care at all stages in academic education. European educational reforms initiated by the 1999 Bologna Process affected architecture education, and shifted the role of research. The number of doctoral programs increased, so the involvement of PhD students in teaching also expanded. This study aims to identify how these changes affect quality in architecture education....
-
Robustness of quantum-randomness expansion protocols in the presence of noise
PublikacjaIn this paper we investigate properties of several randomness generation protocols in the device independent framework. Using Bell-type inequalities it is possible to certify that the numbers generated by an untrusted device are indeed random. We present a selection of certificates which guarantee two bits of randomness for each run of the experiment in the noiseless case and require the parties to share a maximally entangled state....
-
The luminescence study of Sr0.98Li2.5 + zAl1.5 – zO3 + 2zN1 – 2z:0.02Eu coumpounds.
Dane BadawczeEu2+-doped UCr4C4-type oxynitride phosphors are emerging innovative materials to replace oxide and nitride phosphors for high-end light-emitting devices. A series of Sr0.98Li2.5 + zAl1.5 – zO3 + 2zN1 – 2z:0.02Eu phosphors were synthesized by collaborators from the National Taiwan University by precursor engineering, and these products showed an unexpected...
-
Artificial-Hand Technology—Current State of Knowledge in Designing and Forecasting Changes
PublikacjaThe subject of human-hand versatility has been intensively investigated for many years. Emerging robotic constructions change continuously in order to mimic natural mechanisms as accurately as possible. Such an attitude is motivated by the demand for humanoid robots with sophisticated end effectors and highly biomimic prostheses. This paper provides wide analysis of more than 80 devices that have been created over the last 40 years....
-
Leveraging spatio-temporal features for joint deblurring and segmentation of instruments in dental video microscopy
PublikacjaIn dentistry, microscopes have become indispensable optical devices for high-quality treatment and micro-invasive surgery, especially in the field of endodontics. Recent machine vision advances enable more advanced, real-time applications including but not limited to dental video deblurring and workflow analysis through relevant metadata obtained by instrument motion trajectories. To this end, the proposed work addresses dental...
-
DUAL CONSTELLATION GPS/GALILEO MOBILE SYSTEM FOR IMPROVING NAVIGATION OF THE VISUALLY IMPAIRED IN AN URBAN AREA
PublikacjaIt is well known by users of Portable Navigation Device (PND) and other GPS-based devices that positioning suffers from (local) significant decreases of accuracy in partially obscured environments like urbanized areas, where buildings (especially high buildings), trees or terrain block large portions of the sky. In such areas, GPS receiver performance is usually deteriorated by the reduced number of currently available satellite...
-
Accelerometer-based Human Activity Recognition and the Impact of the Sample Size
PublikacjaThe presented study focused on the recognition of eight user activities (e.g. walking, lying, climbing stairs) basing on the measurements from an accelerometer embedded in a mobile device. It is assumed that the device is carried in a specific location of the user’s clothing. Three types of classifiers were tested on different sizes of the samples. The influence of the time window (the duration of a single trial) on selected activities...
-
On the influence of a surface roughness on propagation of anti-plane short-length localized waves in a medium with surface coating
PublikacjaWe discuss the propagation of localized surface waves in the framework of the linear Gurtin–Murdoch surface elasticity and taking into account a roughness of a free boundary. We derive a boundary-value problem for anti-plane motions with curvilinear boundary and surface stresses. Using the asymptotic technique developed earlier, we obtain the form of a localized wave and analyze its amplitude evolution. As the main result we present...
-
ECG measurement from the hand with elbows in the air - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...