Wyniki wyszukiwania dla: POLARIZATION INTERFEROMETERS
-
Hydrogen permeation through welded joints of S690QL steels at cathodic polarisation in sea water in the presence of SRB
PublikacjaPrezentowane są wyniki badan metodą Devanathana- Stachurskyego przenikania wodoru w wodzie morskiej w obecności bakterii redukujących siarczany i w warunkach sterylnych. Badania wykonano na stali S690QL poddanej symulowanym obróbkom cieplnym prowadzącym do struktur modelujących strefy wpływu ciepła. Stwierdzono dodatni wpływ obecności bakterii na przenikanie wodoru. Różnice między poszczególnymi próbkami były minimalne.
-
The BDD electrodes wettability modification by anodic polarization treatment
Dane BadawczeThe dataset contains the raw images, photographs obtained for the contact angle measurement at the surface of the boron-doped diamond (BDD) electrode. The measurements were carried out on after potentiodynamic polarization procedure, at various anodic polarization scan range (no polarization - HTBDD; 1.0 V; 1.4 V; 1.9 V; 2.5 V vs Ag|AgCl, scan rate...
-
Cyclic polarization studies of Mg corrosion in alkaline environment
Dane BadawczeThe dataset contains the cyclic polarization studies of Mg (99.99%) in NaOH electrolyte at different pH values: 10, 11 and 12 aiming at understanding of Mg(OH)2 passive layer formation mechanism and conditions. The electrochemical studies were carried out in a three electrode setup, with Pt mesh as the counter electrode and Ag|AgCl as the reference...
-
A BODIPY‐Molecular Rotor in Giant Unilamellar Vesicles: A Case Study by Polarization‐Resolved Time‐resolved Emission and Transient Absorption Spectroscopy
Publikacja -
Dynamic electrochemical impedance spectroscopy and polarization studies to evaluate the inhibition effect of benzotriazole on copper-manganese-aluminium alloy in artificial seawater
PublikacjaPrzeprowadzono badania wpływu benzotriazolu (BTA) na korozję nowego typ mosiądzu (CMA) w środowisku syntetycznej wody morskiej przy użyciu dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS), techniki polaryzacji rezystancyjnej i ekstrapolacji krzywych Tafela. Wyniki pomiarowe otrzymane przy użyciu tych metod wskazują spadek szybkości korozji wraz ze wzrostem stężenia BTA. Wskazuje to na inhibicyjne własności BTA w...
-
Surface quality control of a thin SiN layer by optical measurements
PublikacjaFiber optic interferometers have a wide range of applications, including biological and chemical measurements. Nevertheless, in the case of a reflective interferometer setup, standard silver mirrors cannot be used in every measurement, due to their chemical activity. This work investigates the surface quality of a thin optical layer of silicon nitride (SiN), which can serve as an alternative material for silver mirrors. We present...
-
Electrochemical methods for corrosion rate determination under cathodic polarisation conditions - a review. Part II - AC methods
PublikacjaPrzedstawiono krytyczny przegląd prac dotyczących wykorzystania metod elektrochemicznych zmiennoprądowych do wyznaczania prądu korozyjnego metali polaryzowanych katodowo. Przedyskutowano stosowanie klasycznej liniowej spektroskopii impedancyjnej (EIS) z użyciem sygnałów pobudzających niskoamplitudowych, a następnie techniki zmiennoprądowe bazujące na sygnałach wysokoamplitudowych, a więc w zakresie nieliniowej charakterystyki polaryzacyjnej...
-
Electrochemical methods for corrosion rate determination under cathodic polarisation conditions - a review. Part I - DC methods
PublikacjaPrzedstawiono krytyczny przegląd prac dotyczących wykorzystania metod elektrochemicznych stałoprądowych do wyznaczania prądu korozyjnego metali polaryzowanych katodowo. Opisano dotychczasowe sposoby oceny skuteczności ochrony katodowej na podstawie pomiarów krzywych polaryzacji i rezystancji polaryzacyjnej. Scharakteryzowano metody matematyczne i oprogramowanie opracowane do analizy komputerowej krzywych polaryzacji w celu wyznaczenia...
-
Novel Coplanar-Strip-Based Excitation Technique for Design of Broadband Circularly Polarization Antennas with Wide 3-dB Axial Ratio Beamwidth
PublikacjaIn this paper, a novel excitation technique for design of a single-point-fed compact low-profile wide-slot antennas with broadband circular polarization (CP) and wide 3 dB axial ratio (AR) beamwidth is presented. Two inverted L-shape parasitic strips placed coplanar to the microstrip line of an asymmetric CPW, and a horizontal strip that protrudes from the vertical edge of the backside ground plane of the substrate are used for...
-
Fe3–xInSnxO6 (x = 0, 0.25, or 0.5): A Family of Corundum Derivatives with Sn-Induced Polarization and Above Room Temperature Antiferromagnetic Ordering
PublikacjaThree new double corundum derivative compounds, Fe3−xInSnxO6 (x = 0. 0.25, or 0.5), were synthesized at high pressure and temperature (6 GPa and 1400− 1450 °C). All of the compounds order antiferromagnetically well above room temperature (TN = 608, 532, and 432 K for x = 0, 0.25, and 0.5, respectively). The x = 0 phase crystallizes as centrosymmetric R3̅c, but the inclusion of closed-shell d10 Sn4+ induces x = 0.25 and 0.5 to crystallize...
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublikacjaThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
-
A BODIPY‐Based Molecular Rotor in Giant Unilamellar Vesicles: A Case Study by Polarization‐Resolved Time‐Resolved Emission and Transient Absorption Spectroscopy
PublikacjaBODIPY and BODIPY-derived systems are widely applied as fluorophores and as probes for viscosity detection in solvents and biological media. Their orientational and rotational dynamics in biological media are thus of vital mechanistic importance and extensively investigated. In this contribution, polarization-resolved confocal microscopy is used to determine the orientation of an amphiphilic BODIPY-cholesterol derivative in homogeneous...
-
Crack monitoring in concrete beams under bending using ultrasonic waves and coda wave interferometry: the effect of excitation frequency on coda
PublikacjaConcrete is one of the most widely used construction materials in the world. In recent years, various non-destructive testing (NDT) and structural health monitoring (SHM) techniques have been investigated to improve the safety and control of the current condition of concrete structures. This study focuses on micro-crack monitoring in concrete beams. The experimental analysis was carried out on concrete elements subjected to three-point...
-
Ellipsometric monitoring during the polarization studies of Mg corrosion in alkaline environment
Dane BadawczeThe dataset contains the ellipsometric results from the Mg polarization studies aiming at understanding the Mg(OH)2 passive layer formation mechanism and conditions. The single-wavelength ellipsometer ELX-02C from Dr Riss GmbH was utilized, operating He-Ne laser at 632.8 nm. The polarization conditions for the experiment are depicted in the related...
-
High-Resolution, Broad-Range Detection Setup for Polarimetric Optical Fiber Sensors
PublikacjaA common-path polarization interferometer using a Wollaston prism and an area detector for the measurement of retardation or optical path difference is presented. Employing a moderate-resolution 1280 by 1024 pixel monochrome camera, it offers a measurement range of approximately 780 radians at 830 nm and 1350 radians at 515 nm while maintaining a high measurement resolution. Retardation introduced by a zero-order waveplate or a...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublikacjaLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
The influence of polarization of titania nanotubes modified by a hybrid system made of a conducting polymer PEDOT and Prussian Blue redox network on the Raman spectroscopy response and photoelectrochemical properties
PublikacjaIn this work we show the impact of applied potential on network vibrations and photoelectrochemical properties of a composite material containing hydrogenated titania nanotubes and poly (3,4-ethylenedioxythiophene) with iron hexacyanoferrate (H-TiO2/pEDOT:Fehcf) acting as a redox centre. For this purpose, Raman spectroscopy measurements under the working electrode (WE) polarization were carried out, allowing investigation of changes...
-
Series-Slot-Fed Circularly Polarized Multiple-Input-Multiple-Output Antenna Array Enabling Circular Polarization Diversity for 5G 28-GHz Indoor Applications
PublikacjaIn this paper, a four-element circularly polarized series-slot-fed multiple-input-multiple-output (MIMO) antenna array with circular polarization diversity is presented. The proposed design utilizes a combination of 45-degree inclined slots and a straight microstrip line feeding technique. The two antennas are designed to operate with the opposite sense of circular polarization (CP). CP is achieved by placing a patch of just about...
-
Rapid Re-Design and Bandwidth/Size Trade-Offs for Compact Wideband Circular Polarization Antennas Using Inverse Surrogates and Fast EM-Based Parameter Tuning
PublikacjaDesign of compact wideband circularly polarized (CP) antennas is challenging due to the necessity of simultaneous handling of several characteristics (reflection, axial ratio, gain) while maintaining a small size of the structure. Antenna re-design for various operating bands is clearly more difficult yet practically important because intentional reduction of the bandwidth (e.g., by moving the lower edge of the operating band up...
-
SEM micrographs of cavitation erosion-corrosion of aluminium alloy 2024 with anodic polarization
Dane BadawczeThe dataset contains Scanning Electron Micrographs of aluminium alloy 2024 samples made after cavitation erosion-corrosion exposure using a vibratory transducer (in accordance with ASTM G32). The experiment duration was 240 min, with cyclic cavitation exposure in on/off cycles 30s:30s. The electrolyte was 0.1 M KNO3 solution. Some samples were anodically...
-
Poor evidence for depolarization block but uncoupling of nigral from striatal dopamine metabolism after chronic haloperidol treatment in the rat
Publikacja -
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublikacjaThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
The microstructure of aluminium alloys AA1050 and AA7075 subjected to anodic polarization at 8V in KOH electrolyte
Dane BadawczeThe dataset contains SEM pictures of the microstructure of aluminum alloy AA1050 and AA7075 exposed in aqueous KOH in the pH range between 14–11. Two sets of samples are presented, revealing the topography of the alloys when exposed to aggressive media under open circuit potential conditions as well as when subjected potentiodynamic polarization ranging...
-
Distance measurement by the low coherent interferometer
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublikacjaOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Model dynamic electrochemical impedance spectroscopy (DEIS) results obtained with various DC polarization rates
Dane BadawczeThe dataset contains results of model dynamic electrochemical impedance spectroscopy studies carried out on a setup of 10 diodes in series, which were connected in parallel with a condenser. The impedance data were acquired every 1 s (the analytic window length for Fourier Transform was 1 s). The model system was polarized between 0 and +8 V with DEIS...
-
Low-coherence photonic method of electrochemical processes monitoring
PublikacjaWe present an advanced multimodality characterization platform for simultaneous optical and electrochemical measurements of ferrocyanides. Specifcally, we combined a fber-optic Fabry– Perot interferometer with a three-electrode electrochemical setup to demonstrate a proof-ofprinciple of this hybrid characterization approach, and obtained feasibility data in its monitoring of electrochemical reactions in a boron-doped diamond flm...
-
Surface activation by cyclic polarization in 1M HCl and its effects on the electrochemical response of CB-PLA 3D printed electrodes
Dane BadawczeThe dataset contains the electrochemical studies performed for surface activation of the CB-PLA 3D printed electrodes by electrolysis in 1M HCl solution. The studies were performed after treatment at different polarization ranges, as labeled in subfolder names. For each electrode the consecutive studies describe different samples, as labeled in subfolders:...
-
Environmental degradation of titanium alloy in artificial saliva
PublikacjaThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
Environmental degradation of Ti alloys in artificial saliva and a role of fluorides
PublikacjaThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Dane BadawczePresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Application of titanium dioxide thin films in fiber optic sensors
PublikacjaThe advance in the nanotechnology and fabrication of micro- and nanostructures has significant impact on development of new optical sensors. Presented study focuses on the applications of the titanium dioxide (TiO2) thin films in fiber optic sensors. The concept of a sensing fiber optic interferometer integrating TiO2 thin film is presented. The cavity of this interferometer is delimited by a 80 nm film fabricated on the end-face...
-
Wideband Off-Body Channel Characteristics with Dynamic User
PublikacjaThis paper presents the preliminary results of a dynamic off-body channel characterisation study, based on wideband measurements at 5.8 GHz in an indoor environment. The Channel Impulse Response (CIR) was measured for a scenario with the user approaching and departing from the off-body antenna. A CIR deconvolution procedure was performed jointly in two polarisations, and the received signal power, Cross-Polarisation Discrimination...
-
Mariusz Kaczmarek dr hab. inż.
OsobyReceived M.Sc., Eng. in Electronics in 1995 from Gdansk University of Technology, Ph.D. in Medical Electronics in 2003 and habilitation in Biocybernetics and Biomedical Engineering in 2017. He was an investigator in about 13 projects receiving a number of awards, including four best papers, practical innovations (7 medals and awards) and also the Andronicos G. Kantsios Award and Siemens Award. Main research activities: the issues...
-
Reliability and Validity of Optoelectronic Method for Biophotonical Measurements
PublikacjaReliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublikacjaFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublikacjaFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Ryszard Jan Barczyński dr hab. inż.
OsobyRyszard Jan Barczyński (ur. 24 czerwca 1957 roku w Gdańsku), polski naukowiec, inżynier, specjalista z dziedziny fizyki ciała stałego i elektronicznych technik pomiarowych. W 1976 roku uzyskał maturę w IV Liceum Ogólnokształcącym im. Tadeusza Kościuszki w Toruniu. Studia wyższe ukończył w 1981 roku w Instytucie Fizyki Politechniki Gdańskiej w specjalności fizyki ciała stałego, uzyskując tytuł zawodowy magistra inżyniera. Od 1981...
-
Detection of immunological agent by optical fiber sensor: preliminary study
PublikacjaThe objective of this study is the application of optical methods for detection of immunological agent concentration. As the agent we used the Cyclaid, produced by Apotex Inc. In this article we investigated different Cyclaid concentrations in water. We used a Fabry-Pérot interferometer working in a reflective mode, the measurements were performed with source with central wavelength λ = 1550 nm. The preliminary investigation have...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublikacjaThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
Anisotropic optical properties of few-layer black phosphorus coatings: from fundamental insights to opto-electrochemical sensor design
PublikacjaFew-layer black phosphorus (FLBP) is characterised by a tuneable bandgap, high carrier mobility and anisotropic optical properties. It therefore has the potential to find applications in electronics and photonics. FLBP oxidizes upon exposure to air, limiting its utility in devices and components. To address this issue, the thesis introduces methods and tools developed for studying FLBP's optical parameters, with a particular emphasis...
-
Maciej Jerzy Głowacki
OsobyMaciej Jerzy Głowacki jest absolwentem Politechniki Gdańskiej. Ukończył z wyróżnieniem studia inżynierskie na Wydziale Mechanicznym (2017) oraz studia magisterskie na Wydziale Elektroniki, Telekomunikacji i Informatyki (2018). Od 2014 roku jest nieprzerwanie zaangażowany w działalność badawczą prowadzoną w Katedrze Metrologii i Optoelektroniki. W pracy naukowej zajmował się m. in. nanoszeniem antybakteryjnych powłok hydroksyapatytowych...
-
Odbiór zbiorczy polaryzacyjny w środowisku wewnątrzbudynkowym
PublikacjaNiniejszy referat dotyczy oceny efektywności odbioru zbiorczego polaryzacyjnego warunkach propagacji sygnałów wewnątrz budynków. W artykule scharakteryzowano warianty odbioru zbiorczego oraz stosowane w nich metody łączenia sygnałów. Ponadto, zdefiniowano wyrażenia służące szacowaniu zysku odbioru zbiorczego dla tych metod. Przedstawiono również metodykę przeprowadzonych badań pomiarowych oraz dokonano analizy wyników tych badań.
-
Three electrode configuration measurements of electrolyte-diffusion barrier-cathode interface
PublikacjaMeasurements of a system consisting of cathode/doped ceria diffusion barrier/doped zirconia electrolyte were made using two- and three-electrode configuration. Results obtained on a three-electrode measurement configuration were compared with and reflect the results obtained in two-electrode configuration. Three-electrode measurements allowed separating the impact of the symmetrical interface in the investigated system. They also...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...