Filtry
wszystkich: 966
-
Katalog
Wyniki wyszukiwania dla: RUSZT BELKOWY
-
Philosophy and Aesthetics
Kursy OnlineHello, welcome to our classes page. We will be working via MS Teams. Link below: https://teams.microsoft.com/l/meetup-join/19%3ameeting_MjE4NmI0M2QtM2UzYi00MTM1LWFkYjEtZTA3MWY0MjZlZDYx%40thread.v2/0?context=%7b%22Tid%22%3a%2286760356-0022-486f-b793-a2d470bba5a5%22%2c%22Oid%22%3a%22744d498a-011e-4d0b-8a3d-08b49c9156ff%22%7d
-
Sposób otrzymywania nieorganicznych soli reszt kwasów metali przejściowych i kationów jednowartościowych, zwłaszcza w postaci mikro- i nanokrystalicznej
Wynalazki -
M2M communications system proposal for maritime applications
PublikacjaThis article describes the proposal to use the M2M communication to enhance the safety of people, ships and other marine infrastructure, in broadly defined marine systems. In addition, there are numerous examples of planned solutions to be implemented in the near future as well as new services. The proposal for M2M communication system architecture is described below. In addition, the use of the STRUGA system radio interface as...
-
The energy consumption during the birch tree sap concentration process using the reverse osmosis system
PublikacjaBirch tree sap was concentrated by mens of the reversed osmosis technique. The energy consumption in a small-scale pilot apparatus was estimated. The threshold value for the water removal above which the specific energy consumption significantly increased was identified. Below the threshold value the reversed osmosis had low energy demand and could be an attractive method for the production of birch tree sap-based beverages.
-
Prace badawcze i wdrożeniowe Zespołu Katedry Systemów Multimedialnych oraz Laboratorium Akustyki Fonicznej, Wydział Elektroniki, Telekomunikacji i Informatyki, Politechniki Gdańskiej
PublikacjaW bogatym dorobku prac naukowych oraz badawczo-wdrożeniowym z zakresu akustyki - Katedry Systemów Multimedialnych kierowanej przez prof. dr hab. inż. Andrzeja Czyżewskiego oraz Laboratorium Akustyki Fonicznej związanej z osobą prof. dr hab. inż. Bożeny Kostek - obecny jest nurt związanych z pracami dedykowanymi monitoringowi akustycznemu środowiska. W latach 2009-2012 pracownicy tych Jednostek zrealizowali projekt badawczy (grant...
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016122431]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular carcinoma - Female, 52 - Tissue image [6170730026743961]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016125761]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adenocarcinoma, NOS - Female, 60 - Tissue image [6210730043073991]
Dane BadawczeThis is the histopathological image of STOMACH tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016124521]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016122741]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016122231]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adenocarcinoma, NOS - Female, 60 - Tissue image [6210730043069001]
Dane BadawczeThis is the histopathological image of STOMACH tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Tubular carcinoma - Female, 52 - Tissue image [617073002674861]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016121641]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Polyp of colon - Female, 79 - Tissue image [6080730009641631]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016125681]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Colon, unspecified - Male, 80 - Tissue image [7210730002081901]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016121721]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [7040247104962161]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [61407300161241]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular carcinoma - Female, 52 - Tissue image [6170730026745351]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Polyp of colon - Female, 73 - Tissue image [608073000964841]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 65 - Tissue image [6140730016124561]
Dane BadawczeThis is the histopathological image of RECTOSIGMOID JUNCTION tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular carcinoma - Female, 45 - Tissue image [6010730010703441]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Corrosion fatigue crack propagation rate characteristics for weldable ship and offshore steels with regard to the influence of loading frequency and seawater temperature
PublikacjaAfter Vosikovsky (1975), the corrosion fatigue crack growth rate (CFCGR) characteristics have been divided into three regions. The region-III rates are very close to mechanical fatigue crack growth rates. CFCGR formulae, including the long-crack length effect (in region I only), the loading frequency effect (in region II only), and the saltwater temperature effect, have been proposed. It has been assumed that CFCGR is proportional...
-
Time reversal invariant single-gap superconductivity with upper critical field larger than the Pauli limit in NbIr2B2
PublikacjaRecently, compounds with noncentrosymmetric crystal structure have attracted much attention for providing a rich playground in search for unconventional superconductivity. NbIr2B2 is a new member to this class of materials harboring superconductivity below Tc = 7.3(2) K and a very high upper critical field that exceeds Pauli limit. Here we report on muon spin rotation (μSR) experiments probing the temperature and field dependence...
-
Low-Power Receivers for Wireless Capacitive Coupling Transmission in 3-D-Integrated Massively Parallel CMOS Imager
PublikacjaThe paper presents pixel receivers for massively parallel transmission of video signal between capacitive coupled integrated circuits (ICs). The receivers meet the key requirements for massively parallel transmission, namely low-power consumption below a single μW, small area of less than 205 μm2, high sensitivity better than 160 mV, and good immunity to crosstalk. The receivers were implemented and measured in a 3-D IC (two face-to-face...
-
Agnieszka Potęga dr inż.
Osoby -
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublikacjaThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Etyka zawodu architekta, III semestr, rok akademicki 2021/2022
Kursy OnlineWelcome to e-learning course of Architect's Proffesional Ethics. Classes will be conducted via TEAMS platform. Link to clasess below: https://teams.microsoft.com/l/meetup-join/19%3ameeting_NGYyZjU0OTItMjgwZC00N2MxLTg5ZjItZDliZDY2YTNiNGUw%40thread.v2/0?context=%7b%22Tid%22%3a%2286760356-0022-486f-b793-a2d470bba5a5%22%2c%22Oid%22%3a%22744d498a-011e-4d0b-8a3d-08b49c9156ff%22%7d
-
Wybrane aspekty montażu przęseł mostu podwieszonego przez Wisłę w Płocku.
PublikacjaProjektowanie i realizacja przeprawy leżącej w ciągu planowanej drogowej obwodnicy Płocka, stanowią jedno z najpoważniejszych zadań inżynierskich początku XXI wieku w Polsce. Most składa się z dwóch zasadniczych odcinków: 586 - metrowej części dojazdowej o konstrukcji belkowej oraz 615 - metrowej części głównej o konstrukcji podwieszonej, przebiegającej zasadniczo nad nurtem rzeki oraz wąskim prawobrzeżnym terenem zalewowym. Przęsło...
-
THE INFLUENCE OF PET MECHANICAL PROPERTIES ON SBM PROCESS PARAMETERS – LITERATURE REVIEW
PublikacjaIn the paper it is said about the influence of PET (polyethylene terephthalate) mechanical properties on SBM (stretch blow molding) process output parameters changes. The below paper mentions also about the influence of PET orientation and crystallization processes on mechanical and thermal properties of PET material during SBM process. All mechanical data of PET material and SBM process output parameters changes are from collected...
-
Selektywne chłodzenie mózgu noworodka po Niedotlenieniu okołoporodowym. Część 1. Medyczne fakty oraz przegląd dostępnych rozwiązań systemów selektywnego chłodzenia mózgu
PublikacjaMózg ludzki jest organem delikatnym, dlatego tak ważne jest zadbanie o to, aby już w momencie przyjścia na świat noworodek miał zapewnioną, w razie konieczności możliwość minimalizacji uszkodzeń neurologicznych, spowodowanych niedotlenieniem okołoporodowym. Niedotlenienie to w dramatyczny sposób zaburza homeostazę mózgu, który jako organ najbardziej energochłonny potrzebuje najwięcej tlenu. Zapoczątkowane brakiem tlenu procesy...
-
The DraC usher in Dr fimbriae biogenesis of uropathogenic E. coli Dr+ strains
PublikacjaBiogeneza fimbrii Dr kodowanych przez operon dra uropatogennych szczepów Escherichia coli (infekcje górnych dróg moczowych) odbywa się na bazie zakonserwowanego systemu sekrecji typu chaperone-usher. Funkcjonowanie powyższego systemu sekrecji opiera się na dwóch komponentach białkowych, periplazmatycznym chaperonie DraB i zewnątrzbłonowym kanale DraC. Białko DraB kontroluje proces składania podjednostek fimbrialnych DraE, natomiast...
-
Actual field corrosion rate of offshore structures in the Baltic Sea along depth profile from water surface to sea bed
PublikacjaThe paper presents the results of field electrochemical investigations on the corrosion rate of carbon steel in seawater of the Baltic Sea at the location of the Baltic Beta production rig. The measurements were conducted throughout the year in seawater at different depths from the sea surface to the sea bed (about 75 m). The results revealed corrosion aggressiveness of the seawater along the entire depth profile. There was...
-
Advantages of the Application of the Temper Bead Welding Technique During Wet Welding
PublikacjaThermo-mechanically rolled S460ML steel was chosen for welding in underwater wet welding conditions by covered electrodes. The main aim of this study was to check the weldability for fillet welds in a water environment by controlled thermal severity (CTS) tests and to check the influence of temper bead welding (TBW) on the weldability of the investigated steel. Non-destructive and destructive tests showed that S460ML steel has...
-
The influence of moderate pressure and subzero temperature on the shelf life of minced cod, salmon, pork and beef meat
PublikacjaThe effect of moderate pressure at subzero temperature on natural microflora of minced cod, salmony, pork and beef meat was studied. Pressure of 193 MPa at –20 °C caused reduction of total bacterial count in pork and beef meat by 1.1 and 0.6 log cycles, respectively, and by about 1.5 log cycles in fish meat. Under these conditions the psychrophilic and psychrotophic bacteria were below the detection limit (<10CFU/g of sample) in...
-
Stomach, unspecified - Male, 75 - Tissue image [9180729562254311]
Dane BadawczeThis is the histopathological image of STOMACH tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Stomach, unspecified - Male, 75 - Tissue image [9180729562252011]
Dane BadawczeThis is the histopathological image of STOMACH tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Duodenum - Male, 61 - Tissue image [11300630022664801]
Dane BadawczeThis is the histopathological image of SMALL INTESTINE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Duodenum - Male, 61 - Tissue image [11300630022661431]
Dane BadawczeThis is the histopathological image of SMALL INTESTINE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular carcinoma - Female, 52 - Tissue image [316063000733741]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Duodenum - Male, 61 - Tissue image [11300630022668601]
Dane BadawczeThis is the histopathological image of SMALL INTESTINE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Duodenum - Male, 61 - Tissue image [11300630022664221]
Dane BadawczeThis is the histopathological image of SMALL INTESTINE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Duodenum - Male, 61 - Tissue image [11300630022664851]
Dane BadawczeThis is the histopathological image of SMALL INTESTINE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Duodenum - Male, 61 - Tissue image [11300630022666091]
Dane BadawczeThis is the histopathological image of SMALL INTESTINE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Magnetic properties of α-KCoPO4 compound with a chiral polar crystal structure
PublikacjaWe have obtained polycrystalline samples of a metastable α variant of KCoPO4 by low temperature (350–400 °C) solid state metathesis reaction of potassium oxalate and ammonium cobalt orthophosphate. The material crystallizes in a polar chiral structure (sg. P63, no. 173). Measurements of magnetic properties reveal antiferromagnetic interactions and no ordering observed down to T = 1.9 K, well below the Weiss temperature |Θcw| =...
-
An in situ derivatization – dispersive liquid–liquid microextraction combined with gas-chromatography – mass spectrometry for determining biogenic amines in home-made fermented alcoholic drinks
PublikacjaA novel dispersive liquid–liquid microextraction (DLLME) gas chromatography mass-spectrometry(GC–MS) method was developed for the determination of 13 biogenic amines in home-made wine sam-ples. The method allows to simultaneous extraction and derivatization of the amines providing a simpleand fast mode of extract enrichment. During the study, two different procedures were examined. Sta-tistical analysis was performed to choose...
-
Effect of Particle Size of Fly Ash Microspheres (FAMs) on the Selected Properties of Concrete
PublikacjaThis paper presents the investigations of selected properties of concrete containing two fractions of fly ash microspheres (FAMs) with grain size up to 200 μm and up to 500 μm. Concrete mixtures with ordinary Portland cement and three substitution rates of cement by FAMs, 1.3%, 2.0%, and 2.6%, were investigated. For all concrete mixes, the constant water–binder ratio (w/b) equal to 0.50 was used. The research program included the...