Filtry
wszystkich: 2658
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: OVER-SETTLEMENTS
-
Determination of mechanical properties of Ti13Nb13Zr cubes made with STL technology subjected to uniaxial compression
Dane BadawczeThe aim of the study was to determine the mechanical properties of Ti13Nb13Zr cubes made with STL technology (3D printing). The experiments were carried out on the Hung Ta universal test machine HT-2402. Cubes with the initial dimensions of 10x10x10 mm were subjected to compression by increasing force to over 80 kN. In various experiments, the angle...
-
Jolanta Łopatowska dr inż.
OsobyJolanta Łopatowska, adiunkt w Katedrze Inżynierii Zarządzania i Jakości na Wydziale Zarzadzania i Ekonomii, jest absolwentką Wydziału Elektroniki PG i Instytutu Organizacji i Projektowania Systemów Produkcyjnych PG oraz doktorem w dyscyplinie nauk ekonomicznych. Jej zainteresowania naukowo-badawcze koncentrują się wokół zaawansowanych organizacyjnie i technologicznie systemów produkcyjnych, ze szczególnym uwzględnieniem procesów...
-
Impact of diffusion coefficient averaging on solution accuracy of the 2D nonlinear diffusive wave equation for floodplain inundation
PublikacjaIn the study, the averaging technique of diffusion coefficients in the two-dimensional nonlinear diffusive wave equation applied to the floodplain inundation is presented. As a method of solution, the splitting technique and the modified finite element method with linear shape functions are used. On the stage of spatial integration, it is often assumed that diffusion coefficient is constant over element and equal to its average...
-
Design and distribution of air nozzles in the biomass boiler assembly
PublikacjaDue to energy crisis as well as increasing pollution of the environment, renewable energy sources usage increases all over the world. These facts encouraged authors to start research over developing a uniform biomass boiler calculation model. This paper presents a design of biomass boiler assembly created for ORC (Organic Rankine Cycle) unit since these systems could achieve strong position in energy industry....
-
Rapid Multi-band Patch Antenna Yield Estimation Using Polynomial Chaos-Kriging
PublikacjaYield estimation of antenna systems is important to check their robustness with respect to the uncertain sources. Since the Monte Carlo sampling-based real physics simulation model evaluations are computationally intensive, this work proposes the polynomial chaos-Kriging (PC-Kriging) metamodeling technique for fast yield estimation. PC-Kriging integrates the polynomial chaos expansion (PCE) as the trend function of Kriging metamodel...
-
Dynamic Tests and Technical Monitoring of a Novel Sandwich Footbridge
PublikacjaA novel sandwich composite footbridge is described in this paper, for the first time after it has been put into operation over the Radunia River in the Pruszcz Gdański municipality. This paper presents results of dynamic tests and describes technical monitoring of the footbridge. The dynamic tests were conducted to estimate pedestrian comfort and were compared with the ones from numerical simulations made in the environment of...
-
Melanocytic naevi, unspecified - Female, 66 - Tissue image [4090730007923481]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanocytic naevi, unspecified - Male, 66 - Tissue image [4090730007925501]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant neoplasm of unspecified ovary - Female, 66 - Tissue image [9020730024817211]
Dane BadawczeThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant neoplasm of unspecified ovary - Female, 66 - Tissue image [3300730069465831]
Dane BadawczeThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Assessment of Emotional Expressions after Full-Face Transplantation
Publikacja -
Investigation and operation problems of metal tanks in Poland
PublikacjaThe paper consists of three parts concerned with steel cylindrical, vertical tank for liquid fuel. In the first part the present trends in tank design and building in Poland are described. The main are: · reduction of environment contamination danger caused by tank leakage and hydrocarbons evaporation, · increasing capacity of new tanks (100000 m3 and more) due to economic factor - reduction of steel amount per m3 of storage capacity....
-
Osoby starsze wobec innowacyjnych form świadczenia usług ubezpieczeniowych
PublikacjaPrzedmiotem zainteresowania badawczego w niniejszym tekście są usługi ubezpieczeniowe świadczone z wykorzystaniem innowacyjnych środków komunikacji: Internetu lub telefonu. W artykule skoncentrowano się na osobach powyżej 50 roku życia, szczególnie narażonych na zjawisko wykluczenia cyfrowego. Na podstawie przeglądu literatury sformułowano hipotezę badawczą: Cechy społeczno – demograficzne osób powyżej 50 roku życia wpływają na ich...
-
Prognozowanie krzywej osiadania pala wierconego z iniekcją ciśnieniową pod podstawą
PublikacjaArtykuł jest kontynuacją tematyki autora dotyczącą mechanizmu działania iniekcji ciśnieniowej pod podstawą pala wierconego. W poprzednich publikacjach, autor wykazał, że iniekcja ta w głównej mierze uaktywnia zwiększone opory gruntu wzdłuż pobocznicy pala. Na tej podstawie w niniejszym artykule zaprezentowano procedurę obliczeniową prognozowania krzywą osiadania pala wierconego z iniekcją ciśnieniową pod podstawą. Przedstawiono...
-
Robert Bogdanowicz dr hab. inż.
OsobyRobert Bogdanowicz received his Ph.D. degree with honours in Electronics from the Gdansk University of Technology. He worked as a post-doc researcher in Ernst-Moritz-Arndt-Universität Greifswald Institut für Physik. He has initiated optical emission imaging of muti-magnetron pulsed plasma and contributed to the development of antibacterial implant coatings deposited by high-power impulse magnetron sputtering. He moved back to...
-
Chronic gastritis, unspecified - Male, 76 - Tissue image [5060730006983841]
Dane BadawczeThis is the histopathological image of STOMACH tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Meningioma, anaplastic - Male, 60 - Tissue image [914073001410741]
Dane BadawczeThis is the histopathological image of MENINGES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Coeliac disease - Female, 22 - Tissue image [4260730038478641]
Dane BadawczeThis is the histopathological image of SMALL INTESTINE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant neoplasm of unspecified ovary - Female, 66 - Tissue image [9020730024817641]
Dane BadawczeThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adnexal tumor, benign - Male, 48 - Tissue image [3300730069443171]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Chronic gastritis, unspecified - Male, 76 - Tissue image [5060730006983931]
Dane BadawczeThis is the histopathological image of STOMACH tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanocytic naevi, unspecified - Male, 66 - Tissue image [4090730007929281]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 140 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 160 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 180 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 200 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 210 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 260 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 290 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 170 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 280 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 150 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 230 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 240 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Jacek Oskarbski dr hab. inż.
OsobyAssociate professor (D.SC.Eng.) in the Department of Civil Engineering at the Gdansk University of Technology. Main research areas are traffic modeling and forecasting, transport planning, intelligent transport systems, traffic engineering, and mobility management. A graduate of the University (1994). He worked as road planner in BPBK and Transprojekt Gdański Office (1993-1996). Pposition of assistant in the Highway Engineering...
-
On the deformation and frequency analyses of SARS-CoV-2 at nanoscale
PublikacjaThe SARS-CoV-2 virus, which has emerged as a Covid-19 pandemic, has had the most significant impact on people's health, economy, and lifestyle around the world today. In the present study, the SARS-CoV-2 virus is mechanically simulated to obtain its deformation and natural frequencies. The virus under analysis is modeled on a viscoelastic spherical structure. The theory of shell structures in mechanics is used to derive the governing...
-
Soiling Effect Mitigation Obtained by Applying Transparent Thin-Films on Solar Panels: Comparison of Different Types of Coatings
PublikacjaDust accumulation on the front cover of solar panels is closely linked to location and orientation of photovoltaic (PV) installation. Its build-up depends on the module tilt angle, frequency of precipitation, humidity, wind strength and velocity, as well as grain size. Additionally, soil composition is determined by solar farm surroundings such as local factories, agricultural crops, and traffic. Over time, molecules of atmospheric...
-
60th anniversary of Department of Manufacturing Engineering and Automation
PublikacjaThe paper presents the outline history of Department of Manufacturing Engineering and Automation of the Gdansk University of Technology over the span of 60 years - throughout the period 1945-2006.
-
Symmetrical power line conditioner - basic properties
PublikacjaIn this paper the basis of analytical modelling of the UPQC arrangements (Unified Power Quality Conditioner) in d-q rotating coordinates, as well as select results of investigations conducted on the simplified small power laboratory model, were talked over. In short form power balance as well as fundamental dependences and analytical model with regard of decoupling circuits, were investigated. Applied method for DC link capacitance...
-
Concept of the agent system for the information technology evaluation
PublikacjaIn this paper the concept of the agent system for the information technology evaluation has been presented. This article includes the concept description and shows abilities of using software tools which can be applicable to implementation and verification of proposed solution. The article is the part of common researches over creation solutions for information technology evaluation which range over using expert's evaluation and...
-
Estimating Intercept Range of Silent Sonar
PublikacjaWhen used in military application, sonars should ensure secretiveness. There is some evidence suggesting that silent sonars have a significant advantage over pulse sonars in the respect. If improved, the secretiveness of silent sonar translates into the distance over witch its soundings signal are detected by intercept sonars. The article gives estimated distances for far, medium, and short range sonars operating in the oceans...
-
Fast Simulation-Driven Design of a Planar UWB Dipole Antenna with an Integrated Balun
PublikacjaThe paper presents a design of an ultra-wideband (UWB) antenna with an integrated balun. A fully planar balun interfacing the microstrip input of the structure to the coplanar stripline (CPS) input of the dipole antenna is introduced. The electromagnetic (EM) model of the structure includes the dipole, the balun, and the microstrip input to account for interactions over the UWB band. The EM model is adjusted for low reflection...
-
Multiple output second-generation current conveyor utilizing high frequency output stage
PublikacjaIn this paper a multiple output second-generation current conveyor (MOCCII) is presented. The main advantage of the proposed general circuit architecture over a typical structure, well known in the literature, is the use of a high passband multiple output current mplifier block instead of cascaded current mirrors. It gives similar frequency responses for all the outputs of the current conveyor and also maintains simplicity of the...
-
Modeling and experimental investigation of the small UPQC systems
PublikacjaIn this paper the basis of analytical modelling of the UPQC arrangements (Unified Power Quality Conditioner) in d-q rotating coordinates, as well as select results of investigations conducted on the simplified small power laboratory model were talked over. In short form power balance as well as fundamental dependences and analytic model with regard of decoupling circuits were investigated. Applied method for DC link capacity selection...