Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1100 g
Dane Badawcze -
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Inhibitors of angiogenesis in cancer therapy – synthesis and biological activity
PublikacjaAngiogenesis is the process of formation of new capillaries from preexisting blood vessels. Angiogenesis is involved in normal physiological processes, and plays an important role in tumor invasion and development of metastases. Vascular endothelial growth factor (VEGF) plays a key role in angiogenesis. VEGF is a mitogen for vascular endothelial cells and stimulates their proliferation. By inhibiting the biological activity of...
-
Supporting Software Project Management Processes Using the Agent System
PublikacjaThe natural development of information technology area stimulates intense growth of various technologies which support basic organization processes. The range of technologies implies appropriate management thereof, as well as accurate correspondence with conducted activities. Abandonment of activities within individual branches in favour of project approach to performed assignments (especially those connected with software development)...
-
Numerical Simulations and Tracer Studies as a Tool to Support Water Circulation Modeling in Breeding Reservoirs
PublikacjaThe article presents a proposal of a method for computer-aided design and analysis of breeding reservoirs in zoos and aquariums. The method applied involves the use of computer simulations of water circulation in breeding pools. A mathematical model of a pool was developed, and a tracer study was carried out. A simplified model of two-dimensional flow in the form of a biharmonic equation for the stream function (converted into...
-
Sensorless Control of Induction Motor Based on Super-Twisting Sliding Mode Observer With Speed Convergence Improvement
PublikacjaThe super twisting sliding-mode observer (ST-SMO) has been proposed to achieve an effective method for alleviating low-order harmonics of measured quantities, issues related to DC drift, and suppression of chattering due to low-frequency sampling. The conventional ST-SMO, on the other hand, suffers from control delay in the convergence trajectory due to the system disturbance, resulting in decreased anti-disturbance capability...
-
Leakage Current Measurements of Surge Arresters
PublikacjaThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Green Therapy w projektowaniu ośrodków medycznych Green Therapy in complex design of health centres
PublikacjaKoncepcja przestrzenna ogrodu terapeutycznego podporządkowana jest generalnej idei otwierania się projektantów na poszukiwanie nowych możliwości poprawy samopoczucia odbiorcy - poprzez zapewnienie użytkownikom poczucia bezpieczeństwa, komfortu i odprężenia, harmonii. Dotyczy to nie tylko grupy osób chorych, które dręczone są przez niepokoje i napięcia wywołane przez niepełnosprawność czy chorobę, ale także pacjentów w różnym wieku...
-
Gasification of Densified Biomass (DB) and Municipal Solid Wastes (MSW) Using HTA/SG Technology
PublikacjaThe necessity of economical and rational use of natural energy sources caused a rapid development of research on the possibilities of using non‐conventional energy resources. Taking the above into account, a new technological process of thermochemical conversion of biomass and communal waste, commonly known as High Temperature Air/Steam Gasification (HTA/SG) and Multi‐Staged Enthalpy Extraction Technology (HTAG‐MEET), was developed....
-
Awaria ściany szczelinowej stanowiącej obudowę wykopu głębokiego
PublikacjaW artykule przedstawiono awarię ściany szczelinowej stanowiącej obudowę wykopu głębokiego. Omówiono warunki geologiczne, hydrogeologiczne i geotechniczne podłoża. Przeprowadzono analizę rozwiązań konstrukcyjnych w kolejnych oszczędnościowych modyfikacjach projektu oraz zrealizowanej wersji. Wykonano obliczenia porównawcze. Wskazano przyczyny wystąpienia awarii. In the paper a failure of diaphragm wall protecting deep excavation...
-
Evolutionary Sets of Safe Ship Trajectories: Evaluation of Individuals
PublikacjaThe paper presents a description of the evaluation phase of the Evolutionary Sets of Safe Ship Trajectories method. In general, the Evolutionary Sets of Safe Ship Trajectories method combines some of the assumptions of game theory with evolutionary programming and finds an optimal set of cooperating trajectories of all ships involved in an encounter situation. While developing a new version of this method, the au-thors decided...
-
Personalized avatar animation for virtual reality
PublikacjaThe paper presents a method for creating a personalized animation of avatar for virtual reality application such as multiplayer on-line games. Animation is stored in a simplified version, containing only keyframes for important avatar poses. This version defines key movements, i.e. roughly describes the avatar's action. Animation is enriched by the user with new motion phases utilizing fuzzy descriptors.Various degrees of motion...
-
User experience and user interface (UX/UI) design of Greencoin mobile application.
PublikacjaThe aim of the Greencoin mobile application is to encourage its users to change their behavior and to act pro-ecologically. The pilot version of the application will operate within the city of Gdańsk. To keep the app’s user base as large as possible, the graphical user interface should be attractive to the broadest possible audience, and the application itself should be easy and fun to use. This work is a continuation of studies...
-
A New Method for Automatic Generation of Animated Motion
PublikacjaA new method for generation of animation with a quality comparable to a natural motion is presented. Proposed algorithm is based on fuzzy description of motion parameters and subjective features. It is assumed that such processing increases naturalness and quality of motion, which is verified by subjective evaluation tests. First, reference motion data are gathered utilizing a motion capture system, then these data are reduced...
-
Znaczenie płci w procesie zakupu marek własnych sieci handlowych – analiza wielogrupowa
PublikacjaThe purpose of the article is to analyze the differences in the behavior of men and women in the process of purchasing store brands (SBs). Using an established conceptual model, we intended to identify differences, depending on gender of buyers, in the size of the effects of store image and brand price-image on perceived risk and subsequently on store brand purchase intention. A total of 652 respondents participated in the study....
-
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublikacjaW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
-
Green chemical and hybrid enzymatic pretreatments for lignocellulosic biorefineries: Mechanism and challenges
PublikacjaThe greener chemical and enzymatic pretreatments for lignocellulosic biomasses are portraying a crucial role owing to their recalcitrant nature. Traditional pretreatments lead to partial degradation of lignin and hemicellulose moieties from the pretreated biomass. But it still restricts the enzyme accessibility for the digestibility towards the celluloses and the interaction of lignin-enzymes, nonproductively. Moreover, incursion...
-
Isolation and some properties of collagen from the backbone of Baltic cod(Gadus morhua)
PublikacjaOssein from Baltic cod backbone was obtained after extraction of non-collagenous protein with 0.1 M NaOH solution and demineralization with 1.0 M HCl solution. The extractions were performed at 4 C for24, 48 and 72 h using a solid/solution ratio from 1:4 to 1:8 (w/v). After 48 h of extraction in 0.5 M acetic acid only about 25% of collagen was dissolved. After 48 h of extraction at optimal concentration of pepsin(4 mg/g ossein)...
-
Hardware cryptography coprocessor for system on chip soft processor
PublikacjaW artykule przedstawiono realizację sprzętową i programową szyfrującejo i deszyfrującego algorytmu AES.Obydwie implementacje zostały zralizowane z wykorzystaniem układu Virtex II i przetestowane. Jako kryterium porónawcze wybrano zużycie zasobów układu oraz wydajność. Realizacja sprzętowa wykonuje operację szyfrowania 2 dekady szybcie niż wersja programowa, ale wymaga pięciokrotnie więcej zasobówIn this paper hardware and software...
-
Fusion of DNA-binding domain of Pyrococcus furiosus ligase with TaqStoffel DNA polymerase as a useful tool in PCR with difficult targets
PublikacjaThe DNA coding sequence of TaqStoffel polymer- ase was fused with the DNA-binding domain of Pyrococcus furiosus ligase. The resulting novel recombinant gene was cloned and expressed in E. coli. The recombinant enzyme was purified and its enzymatic features were studied. The fusion protein (PfuDBDlig-TaqS) was found to have enhanced processivity as a result of the conversion of the Taq DNA polymerase from a relatively low processive...
-
STUDY ON THE EFFECTIVENESS OF THE TURBINE CONDENSER AIR EXTRACTION SYSTEM USING HYDRO EJECTORS
PublikacjaThe aim of the paper is to investigate the effectiveness of the 18K380 steam turbine condenser air extraction system using hydro ejectors. Motivation for the analysis is a need of improvement of the energy conversion ratio of the power plant. To achieve this goal it is necessary to establish efficiency of each subsystem of the energy cycle. The air extraction system is not a highly power consuming system but it has great impact...
-
Beta-galactosidase activity of Meiothermus ruber cells
PublikacjaFreeze-dried cells of Meiothermus ruber catalyses cleavage of o-nitrophenyl-b-D-galactopiranoside (oNPb-gal) and conversion of lactose into glucose and galactose. The permeabilization with 2%toluene,20%ethanol and 20%acetone increased enzymatic activity from 74.87 U/g of lyophilized cells up to 129.44,114.38 and 90.19 U/g,respectively. Ethanol was an effective permeabilizing agent and its efficiency was dependent on the concentration,...
-
Solubilization of keratins and functional properties of their isolates and hydrolysates
PublikacjaThe keratinous wastes of the textile industry and poultry slaughterhouses may be used as sources of soluble keratins or hydrolysates. This review presents methods for processing raw keratin-based materials into bioproducts with functional and bioactive properties suitable for biomedical, cosmetic, food, and agricultural applications. Soluble keratin can be obtained by thermal treatment in some organic solvents, reduction, or oxidation...
-
Properties of recombinant trehalose synthase from Deinococcus radiodurans expressed in Escherichia coli
PublikacjaA trehalose synthase gene from Deinococcus radiodurans(DSMZ 20539)containing 1659 bp reading frame encoding 552 amino acids was amplified using PCR. The gene was finally ligated into pET30Ek/LIC vector and expressed after isopropyl β-d-thiogalactopyranoside induction in Escherichia coli (DE3) Rosetta pLysS. The recombinanttrehalose synthase (DraTreS) containing a His6-tag at the C-terminus was purified by metal affinity chromatography...
-
A Preliminary Study and Analysis of Tidal Stream Generators
PublikacjaFor a sustainable future, tidal energy can play a vital role. Tidal energy relies on the gravitational pull of the Moon and the Sun along with the centrifugal forces created by the Earth. Tidal barrage uses the potential energy from the tide and has been very successful in electricity production. With the help of a turbine, kinetic energy can also be harnessed from tidal currents to generate electricity. However, it is not economically...