Filters
total: 13793
filtered: 1841
-
Catalog
- Publications 8642 available results
- Journals 907 available results
- Conferences 93 available results
- Publishing Houses 2 available results
- People 970 available results
- Projects 78 available results
- Laboratories 1 available results
- Research Teams 1 available results
- Research Equipment 1 available results
- e-Learning Courses 178 available results
- Events 20 available results
- Open Research Data 2900 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: angular displacement sensor, electrically small resonators, microstrip technology, microwave measurement technique, microwave sensors
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Results and models for Novel high frequency components with non-conventional shape employing smooth geometry deformation of 3D solid with FFD
Open Research DataThe project aims to investigate the possibility of developing and manufacturing novel high frequency devices having non-standard geometries, allowing for improved electromagnetic performance over what is achievable with currently available design tools. The non-conventional geometry will be obtained by employing the free-form shape deformation technique...
-
Data from pizoelectric pressure sensor placed inside PWK pump chamber
Open Research DataThe dataset contains raw data acquired from a piezoelectric pressure sensor placed inside PWK pump chamber. Pumping pressure was 10MPa, displacement was set to 100%, oil temperature was 33C. Columns "Czas" stand for a time in seconds and milliseconds, "Napięcie" stands for Voltage in Volts
-
Two-phase water-air flow measurement using gamma-ray absorption technique – plug flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: plug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC...
-
Two-phase water-air flow measurement using gamma-ray absorption technique – slug flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: slug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC...
-
Two-phase water-air flow measurement using gamma-ray absorption technique –bubble flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: bubble flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated...
-
Investigation of temperature changes using a microsphere-based fiber-optic sensor
Open Research DataInvestigation of temperature changes using a microsphere-based fiber-optic sensor with a 200 nm ZnO ALD coating for the purpose of validation the design of the sensor, measurement setup and method of examination of electric cell materials.
-
Experimental dataset on detection of SARS-CoV-2 specific IgG antibodies by the fiber optic microsphere-based sensor
Open Research DataThe presented dataset is related to experimental detection of the ARS-CoV-2 specific IgG antibodies by the fibre optic microsphere-based sensor. To perform measurement we used a dedicated microsphere-based probe whose surface was immobilized.
-
Two-phase water-air flow measurement using gamma-ray absorption technique – transitional plug – bubble flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: transitional plug – bubble flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded...
-
Katania, 2023, Road SS114 – csv data from sensors on bicycle
Open Research DataData collected with bicycle-mounted sensors on 06.07.2023 while cycling on the cycle path along the SS114 road in Catania. The data includes parameters such as: gps coordinates- txt files, brain waves and heart rate- csv file.
-
Radiation pattern measurements of geometrically small antennas performed in non-anechoic environments
Open Research DataThe dataset contains unprocessed measurements of radiation pattern characteristics performed in non-anechoic regime for three geometrically small antenna structures: a spline-parameterized Vivaldi structure, a compact spline-based monopole, and a quasi-Yagi geometry with enhanced bandwidth. The responses have been obtained over broad frequency ranges...
-
A novel method for drop in drop edible oils encapsulation with chitosan using a coaxial technique
Open Research DataThe dataset present a novel one step method for oil encapsulation. In this coaxial system the oil constitutes the core of the capsule, while the chitosan solution is the polymer shell surrounding the core to provide separation of the core from the external environment. In comparison to other encapsulation methods, the presented technique is much simpler...
-
The topography of Bi2VO5.5 ceramics prepared by melt-quenching technique was measured with confocal microscope
Open Research DataThe topography of Bi2VO5.5 ceramics prepared by melt-quenching technique was measured by confocal microscope.
-
Magnetic flux leakage signals of near side defects measured with different velocities
Open Research DataThe dataset contains raw signals measured with the use of the magnetic flux leakage (MFL) technique. Linear Hall effect sensors A1324 were used to measure magnetic flux leakage. Three voltage signals were measured: Bx sensor output, Bz1 sensor output, and difference of Bz1 and Bz2 outputs. An output of a Bx sensor was directly proportional to the tangential...
-
Magnetic flux leakage signals of far side defects measured with different velocities
Open Research DataThe dataset contains raw signals measured with the use of the magnetic flux leakage (MFL) technique. Linear Hall effect sensors A1324 were used to measure magnetic flux leakage. Three voltage signals were measured: Bx sensor output, Bz1 sensor output, and difference of Bz1 and Bz2 outputs. An output of a Bx sensor was directly proportional to the tangential...
-
Long-term measurement of physiological parameters.
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Integrated circuit structure surface images obtained with contact capacitive imaging technique
Open Research DataThe measurements were done using NTEGRA Prima (NT-MDT) device. CSG 10Pt probe.
-
Long-term measurement of physiological parameters (4)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (2)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Linear impedance of Bi2VO5.5 ceramic prepared by traditional melt quenching technique measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Long-term measurement of physiological parameters - child (3)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (4h)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (13h)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (13 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (10h)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (10 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - adult (120 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (60 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Heart rate PPG signals with acceleration captured at wrist during small and moderate body movements
Open Research DataHeart rate PPG signals with acceleration captured at wrist during small and moderate body movements
-
Long-term measurement of physiological parameters - a teenager (9h and 20min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (9 hours and 20 minutes) measurement of physiological parameters was performed on...
-
Data from 76- to 81-GHz mmWave Sensor located at S7 road
Open Research DataThe set consists data recorded employing IWR1642 mmWave sensor from Texas Instruments. The purpose of the experiment was to detect vehicles and their speed in real conditions – at S7 road, near Dworek village (54°14'40.0"N 18°59'59.0"E).
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 6th serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 5 serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 1 serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 12. series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 11. series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 2 serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 7th serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 10th series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (150 minutes) 1 serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 150 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 9th serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...