Filters
total: 4142
filtered: 2926
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: cross-sectional measurement
-
Comparative tests of the wall thickness effect of a glass-reinforced thermosetting plastic coating with a non-circular cross section in a soil-coating object for economic aspect
PublicationCulvert structures made of plastics are employed extensively in the construction of new facilities as well as the renovation of existing ones. Due to the high costs of materials required for the manufacturing of these goods, the objective of this research is focused to lessen the thickness of the walls, which may, on the other hand, result in a reduction in the stiffness of the system. In the course of the testing, the structure...
-
An interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and chlorine concentration measurement errors
PublicationThe design of an interval observer for estimation of unmeasured state variables with application to drinking water distribution systems is described. In particular, the design process of such an observer is considered for estimation of the water quality described by the concentration of free chlorine. The interval observer is derived to produce the robust interval bounds on the estimated water quality state variables. The stability...
-
Effect of temperature and composition on physical properties of deep eutectic solvents based on 2-(methylamino)ethanol – measurement and prediction
PublicationNovel deep eutectic solvents were synthesized using 2-(methylamino)ethanol as hydrogen bond donor with tetrabutylammonium bromide or tetrabutylammonium chloride or tetraethylammonium chloride as hydrogen bond acceptors. Mixtures were prepared at different molar ratios of 1:6, 1:8 and 1:10 salt to alkanolamine and then Fourier Transform Infrared Spectroscopy measurements were performed to confirm hydrogen bonds interactions between...
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublicationIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
Kinetics of Cross-Linking Reaction of Epoxy Resin with Hydroxyapatite-Functionalized Layered Double Hydroxides
PublicationThe cure kinetics analysis of thermoset polymer composites gives useful information about their properties. In this work, two types of layered double hydroxide (LDH) consisting of Mg2+ and Zn2+ as divalent metal ions and CO32− as an anion intercalating agent were synthesized and functionalized with hydroxyapatite (HA) to make a potential thermal resistant nanocomposite. The curing potential of the synthesized nanoplatelets in the...
-
Transformational Leadership and Acceptance of Mistakes as a Source of Learning: Poland-USA Cross-Country Study
PublicationThis study explores the influence of transformational leadership on internal innovativeness mediated by mistakes acceptance, including country and industry as factors to be considered and gender and risk-taking attitude as moderators. General findings, primarily based on the US samples (healthcare, construction, and IT industry), confirmed that transformational leadership and internal innovativeness are mediated by mistakes acceptance...
-
Dynamics of productivity in higher education: cross-european evidence based on bootstrapped Malmquist indices
PublicationAbstract This study examines patterns of productivitychange in a large set of 266 public higher educationinstitutions (HEIs) in 7 European countries across the timeperiod 2001-2005. We adopt consistent bootstrap estimationprocedures to obtain confidence intervals for Malmquistindices of HEI productivity and their components.Consequently, we are able to assess the statistical significanceof changes in HEI productivity, efficiency...
-
The cross-talk between oxidative stress and endocannabinoid system in keratinocytes after UV irradiation
Publication -
Numerical modeling of cross-flow heat exchanger for air-conditioning purposes in preliminary study.
PublicationPraca przedstawia wyniki obliczeń numerycznych krzyżowego płytowo-rurowego wymiennika ciepła przeznaczonego do celów klimatyzacyjnych w początkowym etapie jego projektowania.
-
Board cross-section errors while sawing on twin shaft multi-rip saws
PublicationW pracy przedstawiono wpływ warunków pracy pił na powstawanie błędów przecinania w postaci uskoku na przekroju poprzecznym tarcicy.
-
Calculations of electron impact ionization cross section for simple biomolecules: formic and acetic acids
PublicationObliczono przekroje czynne na jednokrotną jonizację kwasu mrówkowego oraz kwasu octowego. Obliczenia przeprowadzono używając formalizmu BEB w zakresie energii od progu na jonizację do 400 eV. Wyniki porównano z dostępnymi danymi doświadczalnymi.
-
Cross-Cultural Interactions between Expatriates and Local Managers in the Light of Positive Organizational Behaviour
PublicationThe main purpose of this article is to identify the ‘individual positive deviance’ presented by expatriates and local managers in their mutual cooperation. The theoretical basis for the publication is the discussion of the Positive Organizational Behaviour (POB) essence and the application of this approach in the area of expatriation. Attitudes, behaviour, working style and personality traits of employees of different nationalities...
-
Cross-linking of polymer films using phenol-formaldehyde resins with different functional groups
PublicationWell-know phenol-formaldehyde resins are used in the production of press-materials, glues, protective coating, mastics. They take a special place among known oligomers because the products based on them are characterized by a low cost and a series of positive properties. Aim of the work: to show the possibility to create polymeric films based on epoxy resins and modified phenol-formaldehyde resins, which contain unsaturated double...
-
Bearing Capacity of aluminum bars with built-up cross section and glued or welded connections
PublicationThe paper is focused on numerical analysis and experimental test of aluminum bars with glued and welded connections between separate members. The connection properties were tested experimentally. The numerical analysis were conducted for the beam and shell model of the structure. The shape and magnitude of initial geometric imperfection was taken into account
-
Scattering From a Cylindrical Object of Arbitrary Cross Section With the Use of Field Matching Method
PublicationA simple and intuitive solution to scattering problems in shielded and open structures is presented. The main idea of the analysis is based on the direct field matching technique involving the usage of projection of the fields at the boundary on a fixed set of orthogonal basis functions. Different convex shapes and various obstacle materials are considered to verify the validity of the method in open and closed structures. The...
-
Measurements of differential cross sections for elastic electron scattering in the backward direction by molecular oxygen.
PublicationZmierzono różniczkowe przekroje czynne na rozproszenie sprężyste elektronów na cząsteczkach tlenu w zakresie kątów rozproszenia 100-180 st., dla wybranych energii padających elektronów w przedziale 7-20eV. Do pomiarów wykorzystano metodę lokalnego pola magnetycznego.
-
The effect of new non-cross resistant antitumor agents on the energy state of human erythrocytes
PublicationPrzebadano pochodne benzoperimidynowe i antrapirydonowe odnośnie ich wpływu na stan energetyczny ludzkich erytrocytów. Stwierdzono, że poziom nukleotydów jak i wartość AEC erytrocytów nie zmienił się w ciągu 24 h inkubacji z powyższymi związkami. Jest to wynik obiecujący w odniesieniu do ich zastosowania jako związków aktywnych w pokonywaniu oporności wielolekowej.
-
Eine Eeue Technik zur Präzisen Rissfortschrittsmessung im DCB oder im Keilversuch = A novel technique for precise crack length measurement in the DCB or wedge test
PublicationDiverse methods have been tried to study crack length, most basic relying on direct, or microscopic, observation of the crack tip position. Optical correlation, both lasermoiré and speckle interferometry, a single strain gauge and displacement sensorshave also been employed. Crack length measurement is, however, delicate. We present a novel method making use of strain gauges attached to one of the adherends.
-
Miniaturized passive emission test chamber for in-situ measurement of emissions of organic compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air (outdoor). One of the main groups of chemical compounds present in indoor air, with proven harmfulness to health,are volatile organic compounds (VOCs). VOCs present indoor comprise a wide variety of hydrocarbons and hydrocarbons derivatives including aliphatic, aromatics, alkylbenzens,...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
Induction Motor Multiscalar Model Based Sensorless Control Using Power Measurement
Publication -
Influence of the analyzing window on electrode impedance measurement by the continuous frequency scanning method
Publication -
Measurement invariance of the Belief in a Zero‐Sum Game scale across 36 countries
Publication -
<title>Modeling of noncontact temperature measurement system using multiwavelength pyrometry</title>
Publication -
Evaluation of a 10 nm Particle Number Portable Emissions Measurement System (PEMS)
Publication -
Optical Fibre Control-Measurement Systems Of Compound HV/HP Electrical Equipment
Publication -
Calibration of the CMS drift tube chambers and measurement of the drift velocity with cosmic rays
Publication -
Measurement of ethylene production as a method for determining the optimum harvest date of ‘Jonagored’ apples
Publication -
Sweet Cherry Skin Colour Measurement as an Non-Destructive Indicator of Fruit Maturity
Publication -
Energy Recovery Analysis in A-Type Pressure Regulation and Measurement Stations in Istanbul, Esenyurt
Publication -
Low Frequency Noise Measurement of Reverse Polarized Silicon Carbide Schottky Diodes
PublicationW artykule przedstawiono wyniki pomiaró szumów cz. wstecznie spolaryzowanych diod Schottky'ego.
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublicationW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Application of Maximum-Length Sequences to impulse response measurement of hydroacoustic communications systems
PublicationThere is a growing interest in digital transmission of telemetry data on ultrasonic waves. The dependence of signal attenuation on squared frequency, specific to the hy-droacoustic systems, induces problems that do not exist in monochromatic, narrowband radio communications systems. For adapting the transmission parameters to current propagation conditions, a precise knowledge of instantaneous changes of channel performances is...
-
Measurement of magnetic signals of vehicles with denoising by matched filtering with FPGA FFT processor
PublicationW artykule przedstawiono realizację systemu do analizy i identyfikacji pojazdów oparty na pomiarze indukcji magnetycznej. Proponowany system może być zastosowany do wykrywania i identyfikacji pojadów zawierających elementy ferromagnetyczne, które zaburzają pole magnetyczne ziemi. Zaburzenie to można zmierzyć przy zastosowaniu trójosiowych magnetometrów transduktorowych, pracującyh w układzie różnicowycm. Zastosowano w systemie...
-
Research on flue gas flow measurement and modelling in the moving grate biomass boiler
PublicationThe aim of this research was to determine the nature of gas flow in a grate boiler model by the method of Particle Image Velocimetry (PIV) and CFD. The paper presents the comparison of the PIV results with numerical simulations made in the environment of ANSYS Fluent. The main goal of the experiment was to describe the phenomena occurring on the grate. Methodology of modelling solid fuel combustion on the moving grate was proposed...
-
Analysis of distance measurement errors in CW FM sonar with MLS code modulation
PublicationAlthough used in the classic silent sonar, the CW FM sounding signal has a major flaw which is its inaccuracy in determining the distance to a target. The authors of the article have developed a concept of silent sonar using frequency modulation signals switched by pseudorandom codes, already discussed in their previous work. This article presents a detailed analysis of errors in CW FM sonar with pseudo-random sequence code modulation...
-
MEASUREMENT AND ANALYSIS OF A FLOOD WAVE PROPAGATION ON THE KACZA RIVER IN GDYNIA IN NORTHERN POLAND
PublicationKacza river is located in northern Poland in the neighborhood of the Gulf of Gdansk and the Baltic Sea. A Kacza having length of 15 km and catchment area of 53 km2 collects the water into the Gulf mostly from inhabited and forested areas within the administrative boundaries of the city of Gdynia. On the 14th and 15th of July 2016 in northern Poland on the large area of Tri-City agglomeration (Gdynia, Gdansk and Sopot) total daily...
-
Determination of magnetisation conditions in a Double-Core Barkhausen Noise measurement set-up
PublicationThe magnetic Barkhausen effect is useful forassessing 1D and 2D stress states of ferromagnetic steelobjects. However, its extension to technically importantmaterials, such as duplex anisotropic steels, remains challenging. The determination of magnetisation inside the studied object and the electromagnet for various geometries, materials and magnetisation angles is a key issue.Three-dimensional, dynamic finite element analysis...
-
Challenges in oscillometric blood pressure measurement in atrial fibrillation: looking for practical solutions
Publication -
In-service measurement of the small wind turbine test stand for structural health monitoring
PublicationThis paper presents the research activity performed on a Small Wind Turbine (SWT) test stand. Commercially available turbine was modified towards incorporation of the sensors system for condition monitoring. Installed sensors measure angular shaft position, torque applied from the wind loads, vibration accelerations and last but not least rotational speed. All gathered data are then transferred and processed in Test.Lab by means...
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublicationIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
Influence of the analyzing window on electrode impedance measurement by thecontinuous freqency scanning method
PublicationPrzeprowadzono pomiary impedancyjne modelowego układu elektrycznego RC techniką ciągłego skanowania częstotliwościowego. Wyznaczono impedancję modelowego układu dla różnych okien analizujących oraz ich różnych wielkości. Wyznaczone dla różnych okien analizujących wartości R i C porównywano z wartościami rzeczywistymi. Stwierdzono wpływ rodzaju okna analizującego oraz jego długość na dokładność otrzymywanych wyników.
-
Application of polarisation-maintaining side-hole fibres do direct force measurement
PublicationW pracy przedstawiono zastosowanie utrzymujących polaryzację światłowodów typu Side Hole do bezpośredniego pomiaru siły. Dla wybranych struktur tych światłowodów wyznaczono, przy pomocy Metody Elementów Skończonych i metody modów sprzężonych, czułość na siłę działającą prostopadle do osi symetrii światłowodu. Określono zależność tej czułości od poszczególnych wymiarów struktur tych światłowodów. Następnie, biorąc pod...
-
The measurement and calculation of gas temperature inside a switchgear during fault arc period.
PublicationW artykule przedstawiono metodę obliczania temperatury gazu wewnątrz rozdzielnicy szczelnej z izolacją powietrzną podczas zwarć łukowych w oparciu o równanie przewodnictwa cieplnego. Przedstawiono wyniki badań eksperymentalnych temperatury gazów podczas zwarć z łukiem wędrującym. Opisano model do badań, układ probierczy i warunki badań. Wyniki obliczeń porównano z wynikami badań eksperymentalnych.
-
Time domain diagnosis of anticorrosion coatings via shape designed measurement signals.
PublicationW pracy przedstawiono operującą w dziedzinie czasu metodę diagnostyki pokryć przeciwkorozyjnych, na poziomie identyfikacji parametrów obwodu zastępczego. Metoda jest oparta na pobudzeniu obiektu sygnałem niekonwencjonalnym o projektowanym kształcie i pomiarze odpowiedzi obiektu (tzw. obserwabla) po upływie zadanego czasu T. Parametry obwodu zastępczego są obliczane bezpośrednio z obserwabli na podstawie równań wynikających z topologii...
-
Accelerated impedance spectrum measurement via multisine perturbationand digital filter banks
PublicationPrzedstawiono przyspieszoną metodę pomiaru widma impedancyjnego, zorientowaną na pomiary jakości powłok przeciwkorozyjnych, modelowanych liniowymi obwodami zastępczymi. Metoda polega na pobudzeniu układu wielosinusoidalnym sygnałem popudzającym oraz analizie pobudzenia i odpowiedzi obiektu przez bank filtrów cyfrowych. Przedstawiono podstawy teoretyczne metody oraz propozycję metodologii pomiaru. Przeanalizowano wyniki symulacji...
-
Example of practical use of vibration measurement results - study of settlement of the Wisłoujście Tower
PublicationW pracy przedstawiono wyniki identyfikacji parametrów posadowienia wieży Twierdzy Wisłoujście. Badanie oparto na zidentyfikowanych w pomiarach częstotliwościach drgań swobodnych wieży. Przyjęto prosty model dynamiczny obiektu, dobrze opisujący jego zachowanie.
-
Interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and state measurement errors
PublicationThe design of interval observer for estimation of unmeasured state variables for application to drinking water distribution systems is described in this paper. In particular, it considers the design of such observer for estimation of water quality described by free chlorine concentration. An interval observer is derived to produce robust interval bounds on the estimated water quality state variables. The stability and robustness...
-
The Effect of Full-Cell Impregnation of Pine Wood (Pinus sylvestris L.) on Changes in Electrical Resistance and on the Accuracy of Moisture Content Measurement Using Resistance Meters
PublicationThe impact of the full-cell impregnation of pine wood was investigated with respect to changes in electrical resistance and the accuracy of moisture content measurement. This study compared the resistance of impregnated and untreated pine timber harvested from the northern part of Poland (Pomeranian region). The wood was impregnated by the vacuum-pressure method. The preservative (TANALITH E 3475) and coloring (TANATONE 3950) agents...