Filters
total: 305
filtered: 267
Search results for: POWER OUTPUT LOSS COMPENSATION
-
Acute Caffeine Intake Enhances Mean Power Output and Bar Velocity during the Bench Press Throw in Athletes Habituated to Caffeine
Publication -
The Acute Effect of Various Doses of Caffeine on Power Output and Velocity during the Bench Press Exercise among Athletes Habitually Using Caffeine
Publication -
The extended model predictive-sliding mode control of three-level AC/DC power converters with output voltage and load resistance variations
Publication -
Effects of Acute Caffeine Intake on Power Output and Movement Velocity During a Multiple-Set Bench Press Exercise Among Mild Caffeine Users
Publication -
Installation of Compensators in the Power System Transmission Grid
PublicationThe article discusses issues of reactive power compensation in transmission grids, with particular focus on the selection of compensator locations and basic parameters. Attention was focused on modern power electronics systems that ensure full automatic compensator adjustment to voltage or power criteria.
-
Problems of Connecting Wind Farms to the Power System with HV Cables
PublicationThis paper presents problems caused by connecting wind farms to a power system with high voltage cables. The author highlights possible problems with reactive power compensation, depending on the arrangement of the shunt reactor connection and settings of control systems for reactive power and voltage of the wind farm. The paper also discusses issues of increasing active power losses caused by a shunt reactor installation.
-
The Influence of LED Lighting Sources on the Nature of Power Factor
PublicationThis article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...
-
Cascaded Buck Hybrid Interlink Converter for Multiple-Input / Multiple-Output Operation
PublicationThe provision of isolated- and non-isolated DC output voltages by Power electronics power-conditioning devices in the recent ‘green-energy-revolution’ era is on course. In this paper, a structure for multi-input multi-output(MIMO) DC–DC buck converter is proposed to generate output voltages of varying levels with fewer component-count. The DC output voltage of each of the constituting buck converters can be used independently or...
-
Formowanie napięć wyjściowych trójfazowego przekształtnika sieciowego
PublicationW artykule przedstawiono kompensację dwu zasadniczych zjawisk powodujących zniekształcenia prądów fazowych przekształtnika sieciowego. Pierwszym z nich są zniekształcenia napięcia sieci. W celu ich eliminacji zaproponowano uśrednianie za okres podstawowej harmonicznej uchybu regulatora napięcia obwodu pośredniczącego oraz predykcję napięcia sieci. Drugim natomiast są zniekształcenia napięć wyjściowych przekształtnika sieciowego....
-
Modern Arrangement for Reduction of Voltage Perturbations
PublicationThe contents of this chapter encompass general problems and the most important issues of power-supply-quality improvement in AC systems. In the context of the above, consideration is given to evaluation of bilateral interactions of receivers with an electrical power-distribution system and methods of their reduction. Also are discussed the basis of operation of the most important compensation-filtration devices and their applications...
-
Neutral point balancing technique for 3-level neutral point clamped converter with servo system
PublicationNeutral point voltage drift compensation technique in 3-level NPC multilevel converter and servo system is described in the paper. Analytical expressions are obtained for power subsystem elements parameters of servo drive system. Simulation of servo system, based on PMSM motor with 3-level NPC converter is considered.
-
Resonance problems in UHV transmission lines
PublicationThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
Photovoltaic Maximum Power Point Technique based on Incremental Conductance (INCON) control algorithm
PublicationMaximum output power status can significantly improve the deployment rate of solar energy system. In order to get the maximum power output, issue of tracking maximum power point (MPP), reduced harmonics around MPP and improve efficiency of the solar power energy system, this paper presents the improved maximum power point tracking (MPPT) control...
-
Study of the Operation of Synchronous Generator Voltage Regulator During the Creation of Post Blackout Start-up Path
PublicationThis paper presents the influence of automatic voltage regulator (AVR) of synchronous generator on the process of creation of post black-out start-up path. Two elements of AVR have a significant impact on this process: underexcitation limiter (UEL) and load compensation (LC). The authors present a theoretical investigation and simulation results that illustrate how the mentioned elements of AVR affect voltage levels in a power...
-
Nuclear Co-generation: The Analysis of Technical Capabilities and Cost Estimates
PublicationThis paper presents a concept of the parallel connection of a nuclear power plant fitted to provide heat for district heating application, with the CHP and heat plants existing in the supply region, in this case with the heating systems of Wejherowo and Gdynia. Presented variant proposes to add heat to a nuclear power plant’s total output by supplying heat exchangers with the steam from bleeders of low pressure (LP) turbine stage...
-
A Five-Leg Three-Level Dual-Output Inverter
PublicationClassical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...
-
Experimental ORC micro-power plant for CHP application Part A: power plant arrangement
PublicationThe co-generative micro-power plant with the HFE7100 applied as a working medium was designed and built for experimental investigations. The heat output of the plant was assumed equal to 20 kW, while the electric output amounted to about 3kW. Examples of the results of the preliminary experimental research on a boiler, heat exchangers, a pump and a turbine-generator set are presented and analysed.
-
Coupled inductors based filter for matrix converters
PublicationThe use of the coupled inductors in the multipulse matrix converter (MC) systems is described in the paper. The possible arrangements of the system are given together with the description of their operation parameters. Moreover, the influence of the system’s topology on the output power quality is also presented. The invented converter structures evaluation results are given in the form of simulation tests acquired output waveforms...
-
Możliwości sterowania mocą bierną elektrowni wiatrowej : Reactive power control methods in wind parks
PublicationReferat poświęcony jest zagadnieniu sterowania mocą bierną w elektrowniach wiatrowych. W pierwszej części referatu opisano tło problemu sterowania mocą bierną w parkach wiatrowych, podano powody, dla których moc bierna powinna podlegać regulacji oraz zarysowano metody, które mogą być do niej użyte. W celu sprawdzenia proponowanych metod kompensacji, zbudowano model matematyczny elektrowni wiatrowej, którego poszczególne elementy...
-
Multiple output differential OTA with linearizing bulk-driven active-error feedback loop for continuous-time filter applications
PublicationA CMOS circuit realization of a highly linear multiple-output differential operational transconductance amplifier (OTA) has been proposed. The presented approach exploits a differential pair as an input stage with both the gate and the bulk terminals as signal ports. For the proposed OTA, improved linearity is obtained by means of the active-error feedback loop operating at the bulk terminals of the input stage. SPICE simulations...
-
Efficiency limit of excitonic photovoltaic cells under phosphor-based white LED illumination
PublicationThe limit of energy conversion of excitonic photovoltaic cells working under white light illumination generated by phosphor-based LED is analysed using the modified Giebink approach. Particularly, the impact of the optical energy gap and energy loss associated with the excitons dissociation at the heterojunction interface on power conversion efficiency of the device are discussed. From the results of our study it follows that the...
-
Design analysis of combined gas-vapour micro power plant with 30 kW air turbine
PublicationThe article presents basic results of the design analysis of a combined gas-vapour micro power plant with a waste-heat boiler without exhaust reheat, working in the vapour section in the Organic Rankine Cycle (ORC) system. The analysis concerned working media most frequently used in those types of power plants and planned to be used in future. The object of the analysis was a micro power plant with a 30 kW gas (air) turbine for...
-
Design analysis of combined gas-vapour micro power plant with 30 kW air turbine
PublicationThe article presents basic results of the design analysis of a combined gas-vapour micro power plant with a waste-heat boiler without exhaust reheat, working in the vapour section in the Organic Rankine Cycle (ORC) system. The analysis concerned working media most frequently used in those types of power plants and planned to be used in future. The object of the analysis was a micro power plant with a 30 kW gas (air) turbine for...
-
Topography measurement methods evaluation for entire bending-fatigued fracture surfaces of specimens obtained by explosive welding
PublicationIn this paper, the methods of compensation of differences in the results of entire bending-fatigued fracture surface topographies were presented. The roughness evaluation was performed with a focus variation microscope and confocal surface topography measurement techniques. The differences in the ISO 25178 roughness parameters were investigated and procedures for their compensation were studied. It was found that various types...
-
Exergy Losses in the Szewalski Binary Vapor Cycle
PublicationIn this publication, we present an energy and exergy analysis of the Szewalski binary vapor cycle based on a model of a supercritical steam power plant. We used energy analysis to conduct a preliminary optimization of the cycle. Exergy loss analysis was employed to perform a comparison of heat-transfer processes, which are essential for hierarchical cycles. The Szewalski binary vapor cycle consists of a steam cycle bottomed with...
-
Low energy electron mass stopping power in H2
PublicationWe present experimental mass stopping powers of electrons in gaseous H2 obtained with a newly developed electron time-of-flight spectrometer, for the incident electron energy range of 10eV to 25eV. In our procedure the average energy loss is derived from our conversion of measured electron time-of-flight spectra into equivalent electron energy loss spectra so as to obtain the values of mass stopping power for electron scattering...
-
Improving operating efficiency of a gas turboset via cooperation with an absorption refrigerating machine
PublicationThe analysis of increase of ambient air temperature entering the compressor on reduction in power output from the turbine and increase fuel use was conduced. For medium size gas turbine operates in winter and summer conditions elementary power and economical values was calculated. Conditions of the determination of turbine inlet air cooling solution (using thermal storage for reduce equipment size) are presented
-
Control of the wind turbine generator
PublicationWind power system consists of two main parts: wind turbine and electrical generator. Wind turbine converts the energy of the flowing air into mechanical energy, next generator converts this energy into electrical energy that is sent to the power system. These two processes should be realized with maximum efficiency and the following requirements for the control system can be formulated: opti-mal wind power conversion, compensation...
-
Method of sum of power losses as a way for determining the ki coefficients of energy losses in hydraulic motor
PublicationThis paper shows application of the method of sum of power losses to determining energy losses which occur in hydraulic rotary motor in situation when not all laboratory data are at one’s disposal or when no use is made of data contained in catalogue charts. The method makes it possible to determine the coefficients ,ki , of energy losses occurring in the motor. The method of sum of power losses is based on the approach proposed...
-
Core loss resistance impact on sensorless speed control of an induction motor using hybrid adaptive sliding mode observer
PublicationInduction motors (IMs) experience power losses when a portion of the input power is converted to heat instead of driving the load. The combined effect of copper losses, core losses, and mechanical losses results in IM power losses. Unfortunately, the core losses in the motor, which have a considerable impact on its energy efficiency, are not taken into account by the generally employed dynamic model in the majority of the studies. Due...
-
Problemy przyłączania farm wiatrowych do systemu elektroenergetycznego z wykorzystaniem kabli WN
PublicationArtykuł prezentuje problemy, jakie rodzi przyłączanie farm wiatrowych do systemu elektroenergetycznego za pomocą kabli wysokiego napięcia. Autor wskazuje możliwe problemy z kompensacją mocy biernej, w zależności od sposobu przyłączenia dławika kompensacyjnego i nastawień układów regulacji mocy biernej oraz napięcia farmy wiatrowej. Artykuł porusza też zagadnienia zwiększenia strat mocy czynnej powodowanych instalacją dławików kompensacyjnych.
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublicationThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Multi-Transformer Flyback Converter for Supplying Isolated IGBT and MOSFET Drivers
PublicationA multi transformer flyback converter topology for supplying transistor drivers is presented. The topology presents some advantages over typical multi output single transformer, as reduction of effective leakage inductance, equal magnetic coupling between primary and secondary circuits and better isolation between outputs. Simulation study carried out in the LTSpice IV program and preliminary experimental results indicate high...
-
Approximate Cramér–Rao bound on Doppler error in correlation-processing relatively narrowband noise radar
PublicationThe paper studies limitations on accuracy of Doppler estimation in continuous-wave noise radar with correlation processing. Second order properties of output of the correlation receiver are evaluated and an approximate Cram´er-Rao bound on errors of Doppler measurement is derived. The accuracy of Doppler measurements is found to be affected by the following factors: power spectral density of noise signal, frequency response of the...
-
Simplified, multiregional fuzzy model of a nuclear power plant steam turbine
PublicationPower systems, including steam turbines and synchronous generators, are complex nonlinear systems with parameters varying over time. The paper presents the developed simplified, multiregional fuzzy model of the steam turbine of a nuclear power plant turbine generator set and compares the results with a full nonlinear model and commonly used linear input-output model of a steam turbine. The proposed model consist of series of linear...
-
Przekształtnik prądu jako sterownik w układach napędowych z silnikami indukcyjnymi
PublicationThe circuits used for power conversion applied in drives with electric machines are classified into two groups: voltage source inverters (VSI) and current source inverters (CSI). Application of the current source inverter results in better properties of drive than application of voltage source inverter because there is no output filter. The development of power electronics and especially the IGBTs, in which on/off-times are very...
-
Experimental test results of an automatic voltage regulator with independent phase voltage controllers
PublicationThe growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...
-
Wireless Charging Station Design for Electric Scooters: Case Study Analysis
PublicationThis study proposes an example of a wireless charging station design for a small-scale vehicle available on the market. The article analyzes basic transmitter inverter topologies and their compensation methods in terms of flexibility of control, tolerance to uncertainty in positioning, and the possibility of decreasing the integration price. Our comprehensive analysis focuses on the battery voltage range, energy capacity, cost,...
-
A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters
PublicationMultiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...
-
A Power-Efficient Digital Technique for Gain and Offset Correction in Slope ADCs
PublicationIn this brief, a power-efficient digital technique for gain and offset correction in slope analog-to-digital converters (ADCs) has been proposed. The technique is especially useful for imaging arrays with massively parallel image acquisition where simultaneous compensation of dark signal non-uniformity (DSNU) as well as photo-response non-uniformity (PRNU) is critical. The presented approach is based on stopping the ADC clock by...
-
Design and experimental validation of a single-stage PV string inverter with optimal number of interleaved buck-boost cells.
PublicationIncreasing converter power density is a problem of topical interest. This paper discusses an interleaved approach of the efficiency increase in the buck-boost stage of an inverter with unfolding circuit in terms of losses in semiconductors, output voltage ripples and power density. Main trends in the power converter development are reviewed. A losses model was designed and used for the proposed solution to find an optimal number...
-
Static Shunt PE Voltage-Quality Controllers
PublicationThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Predykcyjne sterowanie równoległym filtrem aktywnym ze sprzężeniem od prądu zasilającego
PublicationArtykuł przedstawia nowatorską strategię predykcyjnego sterowania równoległym energetycznym filtrem aktywnym (EFA). Proponowane sterowanie zawiera sprzężenie zwrotne od prądu zasilającego i wiąże zalety sterowania w układzie otwartym oraz zamkniętym – szybkość reakcji na zmianę prądu odbioru i bardzo wysoką skuteczność kompensacji. Wysoka jakość prądu kompensacyjnego wynika również z zastosowania w sterowaniu algorytmów predykcyjnych,...
-
Design Analysis of Micro Gas Turbines in Closed Cycles
PublicationThe problems faced by designers of micro-turbines are connected with a very small volume flow rate of working media which leads to small blades’ height and high rotor speed. In the case of gas turbines this limitation can be overcome by the application of a closed cycle with very low pressure at the compressor inlet (lower than atmospheric pressure). In this way we may apply a micro gas turbine unit of accepted efficiency to work...
-
Performance Characteristics of a Micro-turbine, International
Publication. In the paper a design of a multi-stage micro-turbine with partial admission of all the stages is described in detail and the results of particular experimental investigations and numerical calculations are shown, followed by conclusions. The co-generative micro-power plant with the HFE7100 as a working medium was designed and built for experimental investigations. The values of the main cycle parameters were as follows:- heat...
-
Performance Characteristics of a Micro-Turbine
PublicationIn the paper a design of a multi-stage micro-turbine with partial admission of all the stages is described in detail and the results of particular experimental investigations and numerical calculations are shown, followed by conclusions. The co-generative micro-power plant with the HFE7100 as a working medium was designed and built for experimental investigations. The values of the main cycle parameters were as follows:heat output:...
-
Multiple output second-generation current conveyor utilizing high frequency output stage
PublicationIn this paper a multiple output second-generation current conveyor (MOCCII) is presented. The main advantage of the proposed general circuit architecture over a typical structure, well known in the literature, is the use of a high passband multiple output current mplifier block instead of cascaded current mirrors. It gives similar frequency responses for all the outputs of the current conveyor and also maintains simplicity of the...
-
Dynamic model of nuclear power plant turbine
PublicationThe paper presents the dynamic multivariable model of Nuclear Power Plant steam turbine. Nature of the processes occurring in a steam turbine causes a task of modeling it very difficult, especially when this model is intended to be used for on-line optimal process control (model based) over wide range of operating conditions caused by changing power demand. Particular property of developed model is that it enables calculations...
-
APPLICATION OF REDUNDANCY IN SHIP POWER PLANTS OF OFFSHORE VESSEL
PublicationPower and propulsion systems of offshore units must be of a very high level of reliability. The loss of ability to perform functions of their components causes generally to very high economic losses, which may be increased by unused the weather window resulting to postponing the planned offshore operations. To ensure carrying out so expensive offshore operations in the most reliable way, various types of redundancies are built-in...
-
Power Converter Solutions for Industrial PV Applications—A Review
Publication: As the use of photovoltaics becomes more widespread, new technologies for more efficient energy generation, transmission, and distribution based on power electronics converters are being developed. The most common applications are grid-on, energy storage, hybrid, and high voltage gain applications. These applications impose several additional requirements in the design of power converters associated with the solar battery’s maximum...