Filters
total: 255
filtered: 204
Search results for: shunt active power filter
-
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Static Shunt PE Voltage-Quality Controllers
PublicationThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Interconnection of the Customer-Side Resources Using Single Phase VAPF
PublicationThe paper introduces method for utilization of the customer-side generated energy using single phase voltage active power filter. Structure and control method of the power electronics converter has been described and some simulation results are shown to prove usefulness of this arrangements. Proposed application realizes the following functions: power quality improvement, uninterruptible supplying and energy costs reduction.
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublicationAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Neutral earthing reactor protection
PublicationThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
Resonant Conditions in a Node with an SVC Compensator
PublicationThe primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.
-
SVC and power transformers controllers coordination
PublicationThe use of shunt compensators such as FACTS (for example SVC) in power systems gives possibility of fast and flexible control of voltage or reactive power. An efficient cooperation between a transformer and compensator connected to busbars, or transformer’s tertiary winding, requires a proper coordination of controls. The article contains theoretical considerations and simulation results which indicate that such co-ordination is...
-
Resonance problems in UHV transmission lines
PublicationThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublicationThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Highly linear CMOS triode transconductor for VHF applications
PublicationA high-speed, fully balanced complementary-symmetry metal-oxide-semiconductor (CMOS) triode transconductor is presented. The proposed approach exploits a pseudo-differential-pair triode configuration with a simple adaptive circuit stabilising the drain-to-source voltages of metal-oxide-semiconductor (MOS) transistors. Since no additional active circuits (apart from the resistors made of the cut-off MOS devices) and no feedback...
-
A 0.5 V Nanowatt Biquadratic Low-Pass Filter with Tunable Quality Factor for Electronic Cochlea Applications
PublicationA novel implementation of an analogue low-power, second-order, low-pass filter with tunable quality factor (Q) is presented and discussed. The filter feature is a relatively simple, buffer-based, circuit network consisting of eleven transistors operating in a subthreshold region. Q tuning is accomplished by injecting direct current into a network node, which changes the output resistance of the transistors and, as a result, modifies...
-
Wielopoziomowy przekształtnik trakcyjny SiC z izolacją od sieci 3kV DC realizowaną za pomocą transformatorów 30kHz do napędów EZT
PublicationW referacie przedstawiono wielopoziomowy izolowany kaskadowy przekształtnik DC-AC z tranzystorami SiC MOSFET 1,2kV, przeznaczony do napędów elektrycznych zespołów trakcyjnych (EZT). Zaproponowana konstrukcja przekształtnika, przeznaczonego do pracy przy zasilaniu z sieci trakcyjnej 3kV DC, spełnia założenia energoelektronicznego transformatora trakcyjnego (z ang. Power Electronic Traction Transformer). Budowa modułowa z niskonapięciowych...
-
CMOS implementation of an analogue median filter for image processing in real time
PublicationAn analogue median filter, realised in a 0.35 μm CMOS technology, is presented in this paper. The key advantages of the filter are: high speed of image processing (50 frames per second), low-power operation (below 1.25 mW under 3.3 V supply) and relatively high accuracy of signal processing. The presented filter is a part of an integrated circuit for image processing (a vision chip), containing: a photo-sensor matrix, a set of...
-
VSC converters control for offshore wind farms HVDC grid connection
PublicationThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
-
Size and mass minimization of capacitor bank in a power converter DC line of DC drive with closed loop control system with PWM and current limitation
PublicationPaper deals with evaluation equations for power filter of AC-DC power converter which allows to provide size and mass minimization of capacitor bank in DC drive closed loop systems with PWM and current limitation. Reliability of provided equations is proved by simulation in MATLAB/Simulink
-
A nine-input 1.25 mW, 34 ns CMOS analog median filter for image processing in real time
PublicationIn this paper an analog voltage-mode median filter, which operates on a 3 × 3 kernel is presented. The filter is implemented in a 0.35 μm CMOS technology. The proposed solution is based on voltage comparators and a bubble sort configuration. As a result, a fast (34 ns) time response with low power consumption (1.25 mW for 3.3 V) is achieved. The key advantage of the configuration is relatively high accuracy of signal processing,...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Ladder-Based Synthesis and Design of Low-Frequency Buffer-Based CMOS Filters
PublicationBuffer-based CMOS filters are maximally simplified circuits containing as few transistors as possible. Their applications, among others, include nano to micro watt biomedical sensors that process physiological signals of frequencies from 0.01 Hz to about 3 kHz. The order of a buffer-based filter is not greater than two. Hence, to obtain higher-order filters, a cascade of second-order filters is constructed. In this paper, a more...
-
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
PublicationPoniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublicationLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
Code development of a DSP-FPGA based control platform for power electronics applications
PublicationThis paper focuses on the implementation of power electronics algorithms in control platforms based on DSP-FPGA. Today’s power electronics technology demands high power computation with high speed interfacing at the same time. The most popular configuration is a DSP for the former and a FPGA for the latter. The main goal of this work was to develop a generic control system for power electronics application, but it is explained...
-
Secondary arc modelling for single pole reclosing analyses
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage calculation results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc model implementation is presented. The paper presents the study results for the three types of EHV transmission...
-
Selection of C-Type Filters for Reactive Power Compensation and Filtration of Higher Harmonics Injected into the Transmission System by Arc Furnaces
PublicationThis article presents a method for selecting the elements of a C-type filter working with a conventional LC-type filter for compensating reactive power and filtering out higher harmonics generated by arc furnaces and ladle furnaces. The study was conducted in a steel mill supplied by a 110 kV transmission system, where higher harmonic currents and nonlinear loads were measured. A series of computer simulations were performed under...
-
In-ADC, Rank-Order Filter for Digital Pixel Sensors
PublicationThis paper presents a new implementation of the rank-order filter, which is established on a parallel-operated array of single-slope (SS) analog-to-digital converters (ADCs). The SS ADCs use an “on-the-ramp processing” technique, i.e., filtration is performed along with analog-to-digital conversion, so the final states of the converters represent a filtered image. A proof-of-concept 64 × 64 array of SS ADCs, integrated with MOS...
-
Power electronic transformer based on cascaded H-bridge converter
PublicationIn this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublicationThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter
PublicationThe control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...
-
Evaluation of VSC Impact on Power System Using Adequate P-Q Capability Curve
PublicationRenewable energy sources, which are becoming increasingly popular, often use a voltage source converter (VSC) for connection to the power system. Assessing the effects of connecting such a source to the power system is essential to ensure the proper operation of the power system and the connected source. For this purpose, it is necessary to know the range of active and reactive power generation by the converter. The authors indicate...
-
Niskonapięciowy filtr analogowy CMOS wykorzystujący konwerter ujemnoimpedancyjny
PublicationA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Niskonapięciowy filtr analogowy CMOS oparty o konwerter ujemno-impedancyjny
PublicationA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Feasibility Study GaN Transistors Application in the Novel Split-Coils Inductive Power Transfer System with T-Type Inverter
PublicationA promising solution for inductive power transfer and wireless charging is presented on the basis of a single-phase three-level T-type Neutral Point Clamped GaN-based inverter with two coupled transmitting coils. The article focuses on the feasibility study of GaN transistor application in the wireless power transfer system based on the T-type inverter on the primary side. An analysis of power losses in the main components of the...
-
Ancillary services to grids provided with distributed generation
PublicationThe paper introduces system for utilization of the customer-side generated energy. Additionally system can secure some ancillary services to grids. Those services include: current active filtering, load voltage stabilization and in case of grid voltage faults - uninterruptible load supplying (possible with energy storage device). Presented experimental results confirm flexibility of this arrangement in processes of power delivery...
-
Ultra-Wideband Vivaldi Antenna with an Integrated Noise-Rejecting Parasitic Notch Filter for Online Partial Discharge Detection
PublicationPower transformers and gas-insulated switchgear (GIS) play crucial roles in electrical power grids. However, they may suffer from degradation of insulation material due to wear and tear, leading to their imminent failure. Partial discharges (PDs) are an initial sign of insulation materials degradation which emit signals spanning various physical domains, including electromagnetic. PDs are temporally narrow, high-frequency, stochastic...
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublicationZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....
-
Low-Loss 3D-Printed Waveguide Filters Based on Deformed Dual-Mode Cavity Resonators
PublicationThis paper introduces a new type of waveguide filter with smooth profile, based on specially designed dual-mode (DM) cavity resonators. The DM cavity design is achieved by applying a shape deformation scheme. The coupling between the two orthogonal cavity modes is implemented by breaking the symmetry of the structure, thus eliminating the need for additional coupling elements. The modes operating in the cavity are carefully analyzed...
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublicationIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublicationFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
Technique to improve CMRR at high frequencies in CMOS OTA-C filters
PublicationIn this paper a technique to improve the common-mode rejection ratio (CMRR) at high frequencies in the OTA-C filters is proposed. The technique is applicable to most OTA-C filters using CMOS operational transconductance amplifiers (OTA) based on differential pairs. The presented analysis shows that a significant broadening of CMRR bandwidth can be achieved by using a differential pair with the bodies of transistors connected to...
-
Efficient FPGA Implementation of an RFIR Filter Using the APC–OMS Technique with WTM for High-Throughput Signal Processing
PublicationNowadays, Finite Impulse Response (FIR) filters are used to change the attributes of a signal in the time or frequency domain. Among FIR filters, a reconfigurable filter has the advantage of changing the coefficient in real-time, while performing the operation. In this paper, the Anti-Symmetric Product Coding (APC) and Odd Multiple Storage (OMS) modules are utilized to implement the reconfigurable FIR filter (RFIR–APC–OMS). Herein,...
-
The effect of current signal filtering method on the value of cutting power while sawing wood
PublicationThe goal of this work was to investigate an effect of various signal pre-processings on the outline of the electrical power curve and its influence on the measured cutting force estimation. Two signal processing methods were selected for the needs of the experiment, including digital filter and wavelet transform. The filter used was Butterworth, 3rd order band-stop with the cut-out band from 45 Hz to 55 Hz. The second approach...
-
THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS
PublicationThe paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.
-
Smart acoustic band structures
PublicationSmart acoustic band structures exhibit very interesting and non-standard physical properties due to the periodic nature of their certain characteristic on different scale levels. They manifest mostly in their frequency spectra as socalled frequency band-gaps or stop-bands, what has a great impact on the behaviour of these structures in relation to the propagation of vibro-acoustic signals that can be transmitted through the structures...
-
Implementation of the digital receiver in multibeam long-range sonar
PublicationThe article presents the implementation of a digital receiver in multibeam long - range sonar. Developed by the authors of the article, the implementation was part of sonar modernisation on large Polish Navy ships. The article explains the structure of the receiver, its design details and requirements affecting the architecture. The technical solutions regarding the equipment and signal processing algorithms for determining receiving...
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublicationThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Impact of R/X ratio of distribution network on selection and control of energy storage units
PublicationThe interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublicationNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Investigations on the removal of hydrophobic odorous volatile organic compounds by biotrickling filtration monitored with electronic nose
PublicationThe presented paper presents the results of research on the removal of selected hydrophobic volatile organic compounds (VOCs) from their mixture with air by means of a trickled-bed biofiltration. The efficiency of the removal of toluene and α-pinene, as model VOCs, in a three-section biotrickling filter is evaluated using GCFID and additionally monitored with an electronic nose. The results show that the removal of the model mixture...