Filters
total: 1552
filtered: 1356
displaying 1000 best results Help
Search results for: power system voltage stability
-
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublicationThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
The excitation controller with gain scheduling mechanism for synchronous generator control
PublicationThe power systems, including the synchronous generators and power systems networks, are complex nonlinear systems with configuration and parameters which change through time. That leads to electromechanical oscillations occurring in that system. Thus synchronous generator excitation controller must be capable of providing appropriate stabilization signal over broad range of operating conditions and disturbances. In this paper,...
-
The Influence of LED Lighting Sources on the Nature of Power Factor
PublicationThis article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...
-
MPPT and GMPPT Implementation for Buck-Boost Mode Control of quasi-Z-Source Inverter
PublicationThe focus is on the maximum power point tracking implementation for the buck-boost voltage mode control of a single-phase multilevel inverter based on a three-level neutral point clamped quasi-Z-source topology. To utilize shoot-through states only when boost function is needed and avoid it in the buck mode, two different control approaches are required. This work proposes merged control system which provides switching between...
-
Cascaded Buck Hybrid Interlink Converter for Multiple-Input / Multiple-Output Operation
PublicationThe provision of isolated- and non-isolated DC output voltages by Power electronics power-conditioning devices in the recent ‘green-energy-revolution’ era is on course. In this paper, a structure for multi-input multi-output(MIMO) DC–DC buck converter is proposed to generate output voltages of varying levels with fewer component-count. The DC output voltage of each of the constituting buck converters can be used independently or...
-
Design and experimental validation of a single-stage PV string inverter with optimal number of interleaved buck-boost cells.
PublicationIncreasing converter power density is a problem of topical interest. This paper discusses an interleaved approach of the efficiency increase in the buck-boost stage of an inverter with unfolding circuit in terms of losses in semiconductors, output voltage ripples and power density. Main trends in the power converter development are reviewed. A losses model was designed and used for the proposed solution to find an optimal number...
-
High Performance Control of AC Drives with Matlab/ Simulink
PublicationExplore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublicationThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
Regulacja napięcia w sieci nN z rozproszonymi źródłami energii
PublicationPodłączanie rozproszonych źródeł energii do sieci energetycznych niskiego napięcia powoduje powstawanie problemów zmienności i niesymetrii napięcia, zwłaszcza w przypadku dużych odległości od transformatora zasilającego. W skrajnych przypadkach zachodzi konieczność redukcji mocy generowanej przez źródło podczas oddawaniu energii do sieci. Rozwiązaniem tego problemu jest zastosowanie energoelektronicznego regulatora napięcia składającego...
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublicationHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Quality Evaluation of Voice Transmission Using BPL Communication System in MV Mine Cable Network
PublicationThis article presents results of a quality evaluation study, considering voice transmission in a 6 kV medium voltage cable network using the BPL (Broadband over Power Line) communication system. The tests are carried out under real mining conditions for the selected power cable without voltage, earthed at both sides. Such a method of monitoring work conditions is of great importance, especially during a disaster. Power cables are...
-
Control strategies and comparison of the Dynamic Voltage Restorer
PublicationThis paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...
-
Grid-Forming Operation of Energy-Router Based on Model Predictive Control with Improved Dynamic Performance
PublicationThe focus of this study is on the grid-forming operation of the Energy Router (ER) based on Model Predictive Control (MPC). ER is regarded as a key component of microgrids. It is a converter that interfaces the microgrid (s) with the utility grid. The ER has a multiport structure and bidirectional energy flow control. The ER concept can be implemented in Nearly Zero-Energy Buildings (NZEB) to provide flexible energy control. A...
-
Problems of varistor quality assessment during exploitation
PublicationVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
PublicationIn this paper, a tuning method of a resonant circuit suited for wireless powering of miniature endoscopic capsules is presented and discussed. The method allows for an automatic tuning of the resonant frequency and matching impedance of a full wave rectifier loading the resonant circuit. Thereby, the receiver tunes so as to obtain the highest power efficiency under given conditions of transmission. A prototype receiver for wireless...
-
Decentralized control of a different rated parallel UPS systems
PublicationThe paper presents the single phase uninterruptible power supply (UPS) system with galvanic separated DC-AC-DC-AC converters operating in parallel. The CAN physical layer based system of communication between converters has been developed and applied, which allow to utilize a decentralized master-slave control providing high availability factor of the whole UPS system. The control system of particular converters has been developed...
-
Problemy przyłączania farm wiatrowych do systemu elektroenergetycznego z wykorzystaniem kabli WN
PublicationArtykuł prezentuje problemy, jakie rodzi przyłączanie farm wiatrowych do systemu elektroenergetycznego za pomocą kabli wysokiego napięcia. Autor wskazuje możliwe problemy z kompensacją mocy biernej, w zależności od sposobu przyłączenia dławika kompensacyjnego i nastawień układów regulacji mocy biernej oraz napięcia farmy wiatrowej. Artykuł porusza też zagadnienia zwiększenia strat mocy czynnej powodowanych instalacją dławików kompensacyjnych.
-
Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter
PublicationThe control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...
-
Low current transformer utilizing Co-based amorphous alloys
PublicationMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublicationMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
An Overview of Bidirectional EV Chargers: Empowering Traction Grid-Powered Chargers
PublicationIn recent years, the number of electric vehicles has been at least doubling year after year. As a result, today electric vehicles already account for approximately 10% of the global automotive market, which positively affects environment in urbanized areas. However, to take full advantage of the EV integration it is necessary to use renewable sources for their charging; optimally place charging stations/terminals; optimally manage...
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublicationThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Selection of optimal location and rated power of capacitor banks in distribution network using genetic algorithm
PublicationIn this paper, the problem of placement and rated power of capacitor banks in the Distribution Network (DN) is considered. We try to suggest the best places for installing capacitor banks and define their reactive power. The considered formulation requires the optimization of the cost of two different objectives. Therefore the use of properly multiobjective heuristic optimization methods is desirable. To solve this problem we use...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Voltage Transients Transfer over Medium Voltage Instrument Transformers
PublicationThis paper presents voltage harmonic transfer accuracy problems through voltage transformers which are used in power quality monitoring systems in medium and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid has been tested in the conducted disturbances...
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublicationIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublicationIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters
PublicationMultiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...
-
Neutral earthing reactor protection
PublicationThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
AUTOMATED SYSTEM FOR FLUCTUATION ENHANCED GAS SENSING
PublicationResistance gas sensors exhibit random phenomena (resistance noise) which can be utilized to improve gas sensitivity and selectivity. That new emerging technique has to be investigated to recognize optimal parameters for gas detection. It means that a measurement system has to have ability of numerous parameters adjustment (e.g., sampling frequency, heater voltage, polarization current, voltage noise amplification). That fact induced...
-
Voltage Harmonics Transfer through Medium Voltage Instrument Transformers
PublicationVoltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...
-
Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view
PublicationPower cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...
-
Dynamic variables limitation for backstepping control of induction machine and voltage source converter
PublicationDynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublicationLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Study of prototype multi-pole non-salient field winding for high speed brushless synchronous generator
PublicationIn this paper a non-salient field winding for a brushless synchronous generator working with high speed in an autonomous energy generation system (e.g. airplane power grid) has been presented. A conception of a six-pole cylindrical-rotor with distributed field winding has been proposed. Comparison study of salient and prototype non-salient field winding has been carried out. Chosen simulation and measurement results of the generator...
-
Four level inverter's DC bus voltage balancing with 3-terminal DAB converter
Publication—Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...
-
Niskonapięciowy filtr analogowy CMOS wykorzystujący konwerter ujemnoimpedancyjny
PublicationA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Niskonapięciowy filtr analogowy CMOS oparty o konwerter ujemno-impedancyjny
PublicationA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
PublicationPoniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
-
Multi-Channel Virtual Instrument for Measuring Temperature—A Case Study
PublicationThe article presents the hardware and software configuration of the developed multi-channel temperature measurement system as well as calibration procedures and measurement results verifying the properties of measurement channels. The system has been developed and dedicated primarily for measuring the temperature distribution in a laboratory model simulating underground power lines. With the adopted configuration of the analog...
-
THREE-LEVEL F-TYPE INVERTER
PublicationGiven the recent available IGBT switch modules up to 6.5 kV, 1200 A rating, the prospect of the diode-free variant topology of the three-level neutral-point-clamped (3-level, T-type) inverter in certain medium voltage applications is bright; due to its small part count and low conduction losses compared to the diode-clamped NPC inverter. However, within this voltage range, the input dc voltage rating of 50% of the switches per...
-
Dual Active Bridge (DAB) DC-DC converter for multilevel propulsion converters for electrical multiple units (EMU)
PublicationSemiconductor power devices made from silicon carbide (SiC) reached a level of technology enabling their widespread use in power converters. Two different approaches to implementation of modern traction converters in electric multiple units (EMU) have been presented in recent years: (i) 3.3-kV SiC MOSFET-based three-level PWM inverter with regenerative braking and (ii) 6.5-kV IGBT-based four-quadrant power electronic traction transformer...
-
Power Electronic Transformer For Smart Grid Application
PublicationIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
СИЛОВОЙ ПРЕОБРАЗОВАТЕЛЬ С АКТИВНЫМ ПОДАВЛЕНИЕМ ВЫСШИХ ГАРМОНИК ДЛЯ СИСТЕМ ЭЛЕКТРОСНАБЖЕНИЯ ЛЕТАТЕЛЬНЫХ АППАРАТОВ (Power converter with active suppression of higher harmonics for aircraft power supply systems)
PublicationПредставлены два алгоритма активной фильтрации для силового преобразователя с активным подавлением высших гармоник. Первый алгоритм основан на дискретном преобразовании Фурье: посредством синтезированной системы управления инвертированные измеренные высшие гармоники напряжения поступают на вход инвертора. Второй метод управления основан на алгоритме с использованием принципов самообучения, что значительно снижает потребность в...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublicationEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Interconnection of the Customer-Side Resources Using Single Phase VAPF
PublicationThe paper introduces method for utilization of the customer-side generated energy using single phase voltage active power filter. Structure and control method of the power electronics converter has been described and some simulation results are shown to prove usefulness of this arrangements. Proposed application realizes the following functions: power quality improvement, uninterruptible supplying and energy costs reduction.
-
Conducted EMI Propagation Paths in DC-AC Hard Switching Converter
PublicationIn order to limit the electromagnetic interference (EMI) in power electronics devices, knowledge about the phenomena connected with EMI generation and propagation is necessary. This papers describes the propagation paths in the 3 phase voltage source inverter using wide-band simulation and laboratory test with the signal processing method Wiener filtering, where the transfer functions between voltage across switches and the perturbation...
-
REALIZACJA USŁUGI DSR NA PRZYKŁADZIE DOMÓW JEDNORODZINNYCH
PublicationW artykule przedstawiono ideę usługi DSR, czyli reakcji strony popytowej, dla odbiorców rozproszonych. Polega ona na zmniejszeniu zapotrzebowania na energię elektryczną lub przesunięcia go w czasie. Wdrożenie usługi może w znaczny sposób wpłynąć na pracę systemu elektroenergetycznego – usługa DSR może wspomóc bilansowanie systemu elektroenergetycznego, a także pozytywnie oddziaływać na jego elastyczność, wydajność oraz stabilność....
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublicationNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...