Filters
total: 1724
displaying 1000 best results Help
Search results for: REFRACTIVE INDEX SENSING
-
ZnO coated fiber optic microsphere sensor for the enhanced refractive index sensing
PublicationOptical fiber-based sensors are expected to become key components in the control of industrial processes,and the tuning and the enhancement of their sensing properties are crucial for the further developmentof this technology. Atomic Layer Deposition (ALD), a vapor phase technique allowing for the deposition ofconformal thin films, is particularly suited for the deposition of controllable thin films on challenging sub-strates....
-
DFT studies of the refractive index of boron-doped diamond
PublicationThe density functional theory is one of the optimal solutions in calculation of optical properties of materials on the quantum scale. In this paper, we have investigated the refractive index of a boron-doped diamond structure with the usage of Atomistic Toolkit software from Synopsys. During this study, various methods and pseudopotentials were checked to obtain an optimal performanceaccuracy method for calculation of such materials....
-
Millimeter Wave Negative Refractive Index Metamaterial Antenna Array
PublicationIn this paper, a novel negative refractive index metamaterial (NIM) is developed and characterized. The proposed metamaterial exhibits negative effective permittivity (εeffe) and negative effective permeability (µeffe) at millimeter wave frequency of 28GHz. This attractive feature is utilized to enhance the gain of a microstrip patch antenna (MPA). Two thin layers of 5 5 subwavelength unit cell array of NIM are placed above a...
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublicationIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublicationIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Effect of temperature change on refractive index of an egg white and yolk: a preliminary study
PublicationIn this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
Response of a fiber-optic Fabry-Pérot interferometer to refractive index and absorption changes – modelling and experiments
PublicationThis paper describes how the refractive index and the absorption of investigated substances change the spectrum of the optical radiation at the output of the fiber-optic Fabry-Pérot interferometer. The modeling of the operation of the interferometer takes into account not only the spectra of the refractive index and the absorption of the medium that is inside the cavity, but also spectra of the refractive indices of the core and...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublicationThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
Fiber optic microsphere with a ZnO thin film for potential application in a refractive index sensor – theoretical study
PublicationOptical fiber sensors of refractive index play an important role in analysis of biological and chemical samples. This work presents a theoretical investigation of spectral response of a fiber optic microsphere with a zinc oxide (ZnO) thin film deposited on the surface and evaluates the prospect of using such a structure for refractive index sensing. A microsphere is fabricated by an optical fiber tapering method on the base of...
-
Determination of the refractive index and wavelength‐dependent optical properties of few‐layer CrCl3 within the Fresnel formalism
PublicationBased on previous reports on the optical microscopy contrast of mechanically exfoliated few layer CrCl3 transferred on 285 nmand 270 nmSiO2 on Si(100), we focus on the experimental determination of an effective mean complex refractive index via a fitting analysis based on the Fresnel equations formalism. Accordingly, the layer and wavelength-dependent absorbance and reflectance are calculated. Layer and wavelength-dependent optical...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublicationWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
<title>Nonlinear glasses and metaglasses for photonics, a review: Part I. Nonlinear electrical susceptibility and refractive index</title>
Publication -
Combined Long-Period Fiber Grating and Microcavity In-Line Mach–Zehnder Interferometer for Refractive Index Measurements with Limited Cross-Sensitivity
PublicationThis work discusses sensing properties of a long-period grating (LPG) and microcavity in-line Mach–Zehnder interferometer (µIMZI) when both are induced in the same single-mode optical fiber. LPGs were either etched or nanocoated with aluminum oxide (Al2O3) to increase its refractive index (RI) sensitivity up to ≈2000 and 9000 nm/RIU, respectively. The µIMZI was machined using a femtosecond laser as a cylindrical cavity (d = 60...
-
SU‐FF‐T‐209: New Polymer Gel Dosimeter with High Refractive Index for Artifact‐Free Optical CT Scanning
Publication -
Application of high performance liquid chromatography with ultraviolet diode array detection and refractive index detection to the determination of class composition and the analysis of gasoline.
PublicationZaprezentowano nową metodę HPLC oznaczania składu grupowego benzyn i komponentów benzyn tj. oznaczania zawartości olefin, węglowodorów aromatycznych i parafinowo-naftenowych.
-
UAV-Based Hyperspectral Ultraviolet-Visible Interpolated Reflectance Images for Remote Sensing of Leaf Area Index
PublicationDespite its relation to a number of environmental parameters, ultraviolet (UV) reflectance is rarely used in remote sensing. In this study, we investigate the applicability of UV-vis reflectance for vegetation monitoring with unmanned aerial vehicles (UAV). We measure point reflectance over the study area using a UAV-borne spectrometer, project the points onto the Earth's surface, and interpolate them to obtain continuous reflectance...
-
Underground Water Level Prediction in Remote Sensing Images Using Improved Hydro Index Value with Ensemble Classifier
PublicationThe economic sustainability of aquifers across the world relies on accurate and rapid estimates of groundwater storage changes, but this becomes difficult due to the absence of insitu groundwater surveys in most areas. By closing the water balance, hydrologic remote sensing measures offer a possible method for quantifying changes in groundwater storage. However, it is uncertain to what extent remote sensing data can provide an...
-
Density, sound velocity, viscosity, and refractive index of new morpholinium ionic liquids with amino acid-based anions: Effect of temperature, alkyl chain length, and anion
PublicationIn this work, room temperature synthesis of twenty new ionic liquids (ILs) based on the N-alkyl-N-methylmorpholinium ([Mor1,R], R = 2, 3, 4, 6, 8) cation and N-acetyl-L-amino acid anions (L-alaninate, L-valinate, L-leucinate, L-isoleucinate) was described. The synthesized ILs were characterized by various spectroscopic techniques and high-resolution mass spectrometry. Furthermore, density (ρ), sound velocity (v), viscosity (η)...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Study on Combined Optical and Electrochemical Analysis Using Indium-tin-oxide-coated Optical Fiber Sensor
PublicationThe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Plasma-Based Deposition and Processing Techniques for Optical Fiber Sensing
PublicationPlasma-based techniques are widely applied for well-controlled deposition, etching or surface functionalization of a number of materials. It is difficult to imagine fabrication of novel microelectronic and optoelectronic devices without using plasma-enhanced deposition of thin films, their selective etching or functionalization of their surfaces for subsequent selective binding of chemical or biological molecules. Depending on...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublicationThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
Optical investigations of electrochemical processes using a long-period fiber grating functionalized by indium tin oxide
Publicationhe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Long-Period Gratings and Microcavity In-Line Mach Zehnder Interferometers as Highly Sensitive Optical Fiber Platforms for Bacteria Sensing
PublicationSelected optical fiber sensors offer extraordinary sensitivity to changes in external refractive (RI), which make them promising for label-free biosensing. In this work the most sensitive ones, namely long-period gratings working at (DTP-LPG) and micro-cavity in-line Mach-Zehnder interferometers (µIMZI) are discussed for application in bacteria sensing. We describe their working principles and RI sensitivity when operating in water...
-
Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers
PublicationIn this paper we investigated the response of a fiber-optic Fabry-Pérot sensing interferometer with thin ZnO layers deposited on the end faces of the optical fibers forming the cavity. Standard telecommunication single-mode optical fiber (SMF-28) segments were used with the thin ZnO layers deposited by Atomic Layer Deposition (ALD). Measurements were performed with the interferometer illuminated by two broadband sources operating...
-
Nanocrystalline diamond microelectrode on fused silica optical fibers for electrochemical and optical sensing
PublicationFabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrode on fused silica single mode optical fiber has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with the mean grain size in the range of 100-250...
-
Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film
PublicationThe fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD...
-
Real-time isothermal DNA amplification monitoring in picoliter volumes using an optical fiber sensor
PublicationRolling circle amplification (RCA) of DNA can be considered as a great alternative to the gold standard polymerase chain reaction (PCR), especially during this pandemic period, where rapid, sensitive, and reliable test results for hundreds of thousands of samples are required daily. This work presents the first research to date on direct, real-time and label-free isothermal DNA amplification monitoring using a microcavity in-line...
-
Jakub Szulwic dr inż.
PeopleJakub Szulwic (born 23 December 1974 in Bydgoszcz, Poland) – is an experienced, licensed Land Surveyor, specialized in construction monitoring by the use of photogrammetric methods and laser scanning technology. His specialization are geomatics and geoinformatics. He is an author about 100 publications including 50 indexed in Web of Science (H-index = 15) In 1993, He graduated from Secondary School in Tuchola, Poland on physics...
-
Spectral reflectance and transmission modeling of multi-cavity Fabry-Pérot interferometer with ZnO thin films
PublicationIn this paper spectral reflectance and transmission of a low-coherence fiber-optic Fabry-Pérot interferometer with thin ZnO layers is analyzed using a multi-cavity approach. In the investigated setup two standard single-mode optical fibers (SMF-28) with thin ZnO films deposited on their end-faces form an extrinsic Fabry-Pérot interferometer with air cavity. Calculations of the spectral response of the interferometer were performed...
-
Linear antenna microwave chemical vapour deposition of diamond films on long-period fiber gratings for bio-sensing applications
PublicationThe growth processes of nanocrystalline diamond (NCD) thin films on fused silica optical fibers with UV-induced long-period gratings (LPGs) were investigated with regard to biosensing applications. The films were deposited using a linear antenna microwave plasma enhanced chemical vapor deposition system, which allows for the growth of diamond at temperatures below 350°C. The films exhibited a high refractive index n = 2.32, as...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Enhancing electrochemical properties of an ITO-coated lossy-mode resonance optical fiber sensor by electrodeposition of PEDOT:PSS
PublicationA sensor working in multiple domains may offer enhanced information about the properties of an investigated analyte, including those containing biological species. It has already been shown that a dual-domain sensing capability, i.e., in optical and electrochemical domains, can be offered by lossy-mode resonance (LMR) sensors based on indium-tin-oxide (ITO) thin film. The spectral response of the LMR sensors depends on the refractive...
-
Characterization of Optical and Electrical Properties of Transparent Conductive Boron-Doped Diamond thin Films Grown on Fused Silica
PublicationA conductive boron-doped diamond (BDD) grown on a fused silica/quartz has been investigated. Diamond thin films were deposited by the microwave plasma enhanced chemical vapor deposition (MW PECVD). The main parameters of the BDD synthesis, i.e. the methane admixture and the substrate temperature were investigated in detail. Preliminary studies of optical properties were performed to qualify an optimal CVD synthesis and film parameters...
-
Optical fiber aptasensor for label-free bacteria detection in small volumes
PublicationHighly sensitive devices for fast bacteria detection are sought to be developed with the task of quantifying the worldwide problem of pathogenic bacteria and thus helping to take control over spreading bacterial infections. This work concerns a sensing solution based on microcavity in-line Mach-Zehnder interferometer (μIMZI) induced in an optical fiber. Such a device exhibits ultrahigh sensitivity to refractive index changes...
-
Functional fluorine-doped tin oxide coating for opto-electrochemical label-free biosensors
PublicationSensors operating in multiple domains, such as optical and electrochemical, offer properties making biosensing more effective than those working in a single domain. To combine such domains in one sensing device, materials offering a certain set of properties are required. Fluorine-doped tin oxide (FTO) thin film is discussed in this work as functional optically for guiding lossy modes and simultaneously electrochemically, i.e....
-
Ellipsometric study of carbon nitride films deposited by DC-magnetron sputtering
PublicationWe report the optical properties of a carbon nitride (CNx) film as a function of nitrogen concentration (N/C) of the deposited film. As nitrogen concentration is increased (N/C ratio) in a CNx film, the refractive index and band gap also increase. The real and imaginary parts, n and k (refractive index and extinction coefficient) of the complex refraction index of carbon nitride films were determined by spectroscopic ellipsometry...
-
Anisotropic optical properties of few-layer black phosphorus coatings: from fundamental insights to opto-electrochemical sensor design
PublicationFew-layer black phosphorus (FLBP) is characterised by a tuneable bandgap, high carrier mobility and anisotropic optical properties. It therefore has the potential to find applications in electronics and photonics. FLBP oxidizes upon exposure to air, limiting its utility in devices and components. To address this issue, the thesis introduces methods and tools developed for studying FLBP's optical parameters, with a particular emphasis...
-
Thermal dewetting as a method of surface modification of the gold thin films for surface plasmon resonance based sensor applications
PublicationHere, we report a quick and simple approach with low, optimized production costs to obtain surface plasmon resonance (SPR) based sensors fabricated through a time- and resource-effective method based on thermal dewetting of thin Au films. From the applicative point of view, the method of detection presented here should be easier to implement, since light transmission measurements seem to be much less challenging than light refractive...
-
Mapping of Flood-Prone Areas Utilizing GIS Techniques and Remote Sensing: A Case Study of Duhok, Kurdistan Region of Iraq
PublicationOne of the most common types of natural disaster, floods can happen anywhere on Earth, except in the polar regions. The severity of the damage caused by flooding can be reduced by putting proper management and protocols into place. Using remote sensing and a geospatial methodology, this study attempts to identify flood-vulnerable areas of the central district of Duhok, Iraq. The analytical hierarchy process (AHP) technique was...
-
Overview of planar antenna loading metamaterials for gain performance enhancement: the two decades of progress
PublicationMetamaterials (MTMs) are artificially engineered materials with unique electromagnetic properties not occurring in natural materials. MTMs have gained considerable attention owing to their exotic electromagnetic characteristics such as negative permittivity and permeability, thereby a negative refraction index. These extraordinary properties enable many practical applications such as super-lenses, and cloaking technology, and are...
-
Experimental and predicted physicochemical properties of monopropanolamine-based deep eutectic solvents
PublicationIn this work, the novel deep eutectic solvents (DESs) based on 3-amino-1-propanol (AP) as hydrogen bond donor (HBD) and tetrabutylammonium bromide (TBAB) or tetrabutylammonium chloride (TBAC) or tetraethylammonium chloride (TEAC) as hydrogen bond acceptors (HBAs) were synthesized with different molar ratios of 1:4, 1:6 and 1:8 salt to AP. Fourier Transform Infrared Spectroscopy measurements were performed to provide an evidence...
-
Experimental and predicted physicochemical properties of monopropanolamine-based deep eutectic solvents
PublicationIn this work, the novel deep eutectic solvents (DESs) based on 3-amino-1-propanol (AP) as hydrogen bond donor (HBD) and tetrabutylammonium bromide (TBAB) or tetrabutylammonium chloride (TBAC) or tetraethylammonium chloride (TEAC) as hydrogen bond acceptors (HBAs) were synthesized with different molar ratios of 1: 4, 1: 6 and 1: 8 salt to AP. Fourier Transform Infrared Spectroscopy measurements were performed to provide an evidence...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Reliability and Validity of Optoelectronic Method for Biophotonical Measurements
PublicationReliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate...
-
Acoustic Sensing Analytics Applied to Speech in Reverberation Conditions
PublicationThe paper aims to discuss a case study of sensing analytics and technology in acoustics when applied to reverberation conditions. Reverberation is one of the issues that makes speech in indoor spaces challenging to understand. This problem is particularly critical in large spaces with few absorbing or diffusing surfaces. One of the natural remedies to improve speech intelligibility in such conditions may be achieved through speaking...
-
Tomasz Edward Berezowski dr inż.
PeopleHe was born in 1986 in Warsaw. He graduated in 2009 with honors from the Interfaculty Study of Environmental Protection at SGGW in Warsaw, specialty Restoration and Management of Environment. He defended his doctorate with honors at Vrije UIniversiteit Brussels in 2015. In 2015-2017 he worked as an assistant and then assistant professor at the Faculty of Civil and Environmental Engineering at SGGW. In 2017, he was employed as an...