Search results for: LOW-COHERENCE
-
Measurement of Coherence Bandwidth in UHF Radio Channels for Narrowband Networks
PublicationThis paper presents results of investigation on the coherence bandwidth of narrowband radio channels in 430MHz band. The coherence bandwidth values were estimated froma power delay profile obtained by recording CDMA2000 forward channel signals during real-fieldmeasurements in various environments:mediumcity, flat terrain, and hilly terrain in northern Poland.The results of measurements are compared with characteristic parameters...
-
Advanced polarization sensitive analysis in optical coherence tomography
PublicationThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublicationThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublicationThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Parallel multithread computing for spectroscopic analysis in optical coherence tomography
PublicationSpectroscopic Optical Coherence Tomography (SOCT) is an extension of Optical Coherence Tomography (OCT). It allows gathering spectroscopic information from individual scattering points inside the sample. It is based on time-frequency analysis of interferometric signals. Such analysis requires calculating hundreds of Fourier transforms while performing a single A-scan. Additionally, further processing of acquired spectroscopic information...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublicationCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Polarization sensitive optical coherence tomography with spectroscopic analysis
PublicationOptyczna tomografia koherentna (OCT) jest nieinwazyjną, nieniszczącą i bezkontaktową metodą obrazowania wewnętrznej struktury obiektów i materiałów rozpraszających. Dodatkowo w połączeniu z analizą stanu polaryzacji metoda ta umożliwia badanie lokalnych zmian optycznej anizotropii występującej w badanym obiekcie. W artykule przedstawiono zalety oraz ograniczenia metody oraz przedstawiono propozycję rozszerzenia analizy o badanie...
-
Landscape as the tool of coherence in the land management of rural communes
PublicationEconomic and social transformation of rural areas in Poland after 1990 reveals itself through disintegration of previous spatial order. Building a new pattern requires a vision, which would counteract complex causes of disintegration. The latter belong to institutional domain of planning strategies and the area of common practices. Therefore, agreement on aims and means between spatial policy strategies and tactics of space users...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublicationThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Cross-sectional imaging of materials structure using PS-OCT
PublicationOptical low-coherence tomography is a measurement technique for non-contact and non-destructive investigation of materials inner structure. Nowadays, this method is highly applied in medical treatment especially in dermatology and ophthalmology. During our research we have developed an optical low-coherence tomography system with polarization state analysis for structure examination of a broad range of technical materials. In this...
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublicationIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublicationThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
Polarization sensitive optical coherence tomography for technical materials investigation
Publication -
<title>Synthesized light source for optical coherence tomograph</title>
Publication -
Polarization sensitive optical coherence tomography for technical materials investigation
PublicationZaprezentowano system optycznej tomografii koherentnej z analizą stanu polaryzacji światła. System umożliwia nieniszczące i bezkontaktowe badanie wewnętrznej struktury materiałów warstwowych. Przedstawiono zastosowaną metodę analizy stanu polaryzacji promieniowana wstecznie rozproszonego od badanego obiektu.
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublicationOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems
PublicationSimulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all, the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason,...
-
Reliability and Validity of Optoelectronic Method for Biophotonical Measurements
PublicationReliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate...
-
Emotional Costs, Social Influence, Sense of Coherence, and Coping in the Situation of Reemployment
Publication -
Multilayered structures examination using polarization sensitive optical coherence tomography
PublicationW artykule przedstawiono wstępne wyniki badań struktur warstwowych z użyciem systemu optycznej tomografii koherentnej z analizą stanu poaryzacji (PS-OCT). Omówiono budowę systemu oraz zakres stosowalności metody do badania złożonych struktur warstwowych.
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublicationNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Study of probe signal bandwidth influence on estimation of coherence bandwidth for underwater acoustic communication channel
PublicationA signal transmitted in a shallow Underwater Acoustic Communication (UAC) channel suffers from time dispersion due to the multipath propagation and the refraction phenomena. This causes intersymbol interference of the received signal and frequency-selective fading observed in its spectrum. Coherence bandwidth is one of the key transmission parameters used for designing the physical layer of a data transmission system to minimise...
-
Sense of coherence and acceptance of the disease in patients with lung cancer during palliative chemotherapy
Publication -
The mediational role of future and past time perspectives in the relationship between negative affectivity and sense of coherence
PublicationSense of coherence (SoC) can promote positive coping, and one of its most prominent negative correlates is negative affectivity (NA). In the current study, we hypothesized that future and past time perspectives (TPs) will mediate the relationship between sense of coherence and negative affectivity, and the inverse relationship. The study was questionnaire-based, performed online. N = 719 participants aged 25-45 from...
-
Optical coherence tomography and magnetic resonance imaging visual pathway evaluation in Wolfram syndrome
Publication -
Nano-particle doped hydroxyapatite material evaluation using Spectroscopic Polarization Sensitive Optical Coherence Tomography
PublicationBio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp....
-
Mild poikilocapnic hypoxia increases very low frequency haemoglobin oxygenation oscillations in prefrontal cortex
PublicationBackground: The aim of the study was to investigate the effect of mild cerebral hypoxia on haemoglobin oxygenation(HbO2), cerebrospinal fluid dynamics and cardiovascular physiology. To achieve this goal, four signals were recorded simultaneously: blood pressure, heart rate / electrocardiogram, HbO2 from right hemisphere and changes of subarachnoid space (SAS) width from left hemisphere. Signals were registered from 30 healthy,...
-
Niskokoherencyjne czujniki światłowodowe wykorzystujące cienkowarstwowe struktury nanodiamentowe
PublicationZnaczny rozwój technologii wytwarzania czujników światłowodowych spowodował, że są one powszechnie dostępne i stosowane w wielu gałęziach przemysłu, nauki oraz medycyny. Zastosowanie nowych materiałów w konstrukcji takich czujników niesie za sobą duży potencjał. Celem rozprawy jest przedstawienie możliwości wykorzystania cienkowarstwowych struktur nanodiamentowych w niskokoherencyjnych czujnikach światłowodowych, które poprawią...
-
A la recherche d’une coherence perdue – Possible Arguments for the Non-application of EU Law in Member States
PublicationThe European Union (EU) is an international organization which has a broad scope of competences that have been transferred to it by its Member States in the founding Treaties. The object of the article is to identify arguments raised, or that potentially might be raised, by national Constitutional Courts (and in the future possibly by other actors as well) to exclude in certain instances the application of EU law or EU jurisprudence...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Application of boron-doped diamond film and ZnO layer in the Fabry-Pérot interferometer
PublicationIn this article there have been presented the use of boron-doped diamond films for sensor applications. The low-finesse Fabry-Pérot interferometer working in the reflective mode has been implemented. Two kinds of reflective layers have been elaborated: boron-doped diamond thin films and zinc-oxide (ZnO) layer. Thin ZnO layers were deposited by Atomic Layer Deposition (ALD) on the face of a standard telecommunication single-mode...
-
Ce site dilution effects in the antiferromagnetic heavy fermion CeIn3
PublicationLa-doped intermetallic single crystals of Ce1−xLaxIn3 were synthesized via an In self-flux method throughout the entire range (x = 0–1). The prototypical heavy-fermion compound CeIn3 shows an antiferromagnetic phase transition at 10.1 K and becomes superconducting near a critical pressure where TN is completely suppressed. As the La concentration increases, Ce moments are diluted, and the lattice constant increases linearly, satisfying Vegard’s...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublicationIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
Application of the Fractional Fourier Transform for dispersion compensation in signals from a fiber-based Fabry-Perot interferometer
PublicationOptical methods of measurement do not require contact of a probe and the object under study, and thus have found use in a broad range of applications such as nondestructive testing (NDT), where noninvasive measurement is crucial. Measuring the refractive index of a material can give a valuable insight into its composition. Low‑coherence radiation sources enable measurement of the sample’s properties across a wide spectrum, while...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Spectral reflectance and transmission modeling of multi-cavity Fabry-Pérot interferometer with ZnO thin films
PublicationIn this paper spectral reflectance and transmission of a low-coherence fiber-optic Fabry-Pérot interferometer with thin ZnO layers is analyzed using a multi-cavity approach. In the investigated setup two standard single-mode optical fibers (SMF-28) with thin ZnO films deposited on their end-faces form an extrinsic Fabry-Pérot interferometer with air cavity. Calculations of the spectral response of the interferometer were performed...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublicationIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Photonic sensor to detect rapid changes in CRP levels
PublicationOne of the most important biomarkers used to determine inflammation is C-reactive protein (CRP). Its level, when it is within the range that does not define inflammation, informs about the risk of cardiovascular events. If the norm is exceeded and inflammation is detected in the body, CRP level can increase 1000 times within a few hours. The type of infection can also be determined based on the level of elevated CRP. All this makes...
-
Theory versus experiment for vacuum Rabi oscillations in lossy cavities
PublicationThe 1996 experiment by Brune et al. [Phys. Rev. Lett. 76, 1800 (1996)] on vacuum Rabi oscillation is analyzed by means of alternative models of atom-reservoir interaction. Agreement with experimental Rabi oscillation data can be obtained if one defines jump operators in the dressed-state basis and takes into account thermal fluctuations between dressed states belonging to the same manifold. Such low-frequency transitions could...
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublicationRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...
-
Does pandemic denial help or harm? Belief in COVID-19 and experience of it affect psychological consequences of using neurotic defence mechanisms
PublicationObjective: The COVID-19 pandemic may activate thoughts of death, leading to aversive psychological states. In such situations, defence mechanisms emerge; however, their adaptability depends on many factors. The aim of the study was to investigate the relationship between neurotic defence style and depressive symptoms. We assumed that the sense of coherence underlies this correlation and investigated how both believing (or not)...
-
Selected properties and parameters of radio channel impulse response estimation in ISM 2.4 GHz band
PublicationThe article presents experimental research indicating that the impulse response of the communication channel, determined in practice, are not of an universal character, but only represent its approximate value for the frequency on which this measurement was made. Phases for each of the replicas of the measurement signal were determined during the analysis of the received signals in the baseband. Phase changes of individual replicas...
-
Probe signal processing for channel estimation in underwater acoustic communication system
PublicationUnderwater acoustic communication channels are characterized by a large variety of propagation conditions. Designing a reliable communication system requires knowledge of the transmission parameters of the channel, namely multipath delay spread, Doppler spread, coherence time, and coherence bandwidth. However, the possibilities of its estimation in a realtime underwater communication system are limited, mainly due to the computational...
-
Measurement of Impulse Response of Shallow Water Communication Channel by Correlation Method
PublicationPerformances of underwater acoustic communication (UAC) systems are strongly related to specific propagation conditions of the underwater channel; conditions that can additionally change in time due to the movement of the acoustic system transmitter and receiver or to reflection by underwater objects of the transmitted signal. The time-varying impulse response is a comprehensive description of dynamically changing transmission...
-
Zastosowanie optycznej tomografii niskokoherentnej do 2-wymiarowego obrazowania cienkich warstw polimerów
PublicationW artykule omówiono zasadę działania i przedstawiono podstawowe właściwości systemu OCT (Optical Coherence Tomography). Na przykładzie folii polietylenowej przedyskutowano możliwości wykorzystania systemu do badanie wewnętrznej struktury warstwowej obiektów niebiologicznych. Przedstawiono i omówiono wyniki przeprowadzonych badań nad warstwowymi materiałami przeźroczystymi.
-
Highly porous nanoberyllium for X-ray beam speckle suppression
PublicationThe speckle suppressor device containing highly porous nanoberyllium is proposed for manipulating with the spatial coherence length and removing undesirable speckle structure during the imaging experiments. We report a special device called the speckle suppressor, which contains the highly porous nanoberyllium plate, compacted from both sides by two beryllium windows. By insertion the speckle suppressor in the X-ray beam it allows...
-
Efficacy of coping with work-related stress by firemen
PublicationThe aim of this study was efficacy of coping with work-related stress by firemen with reference to subjective health evaluation. Theoretical model of process of stress by Lazarus was applied. The group consistent of 230 line-duty firemen. Participation in traumatic events and sense of coherence both directly and indirectly, by stress, affected the health among firemen. In stress confrontation a wider array of task and emotional...
-
Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
PublicationPial artery adjustments to changes in blood pressure (BP)may last only seconds in humans. Using a novelmethod called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of...
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublicationThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...