displaying 1000 best results Help
Search results for: BIOSENSORS , METASURFACES , SENSORS , GRAPHENE , OPTICAL SENSORS , SENSITIVITY , REFRACTIVE INDEX
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublicationtIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors
PublicationThis paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume...
-
Gradient-Index (GRIN) Matrices Based On Mosaic Assembling Technology (MAT) For Multichannel Fiberoptic Environmental Sensors
Publication -
Fixed Pattern Noise Reduction and Linearity Improvement in Time-Mode CMOS Image Sensors
PublicationIn the paper, a digital clock stopping technique for gain and offset correction in time-mode analog-to-digital converters (ADCs) has been proposed. The technique is dedicated to imagers with massively parallel image acquisition working in the time mode where compensation of dark signal non-uniformity (DSNU) as well as photo-response non-uniformity (PRNU) is critical. Fixed pattern noise (FPN) reduction has been experimentally validated...
-
Integration of inertial sensors and GPS system data for underwater navigation
PublicationThe Inertial Navigation System (INS) is usually employed to determine the position of an underwater vehicles, like Remotely Operated Vehicles (ROV) and, more recently, Autonomous Underwater Vehicle (AUV). The accuracy of the position provided by the INS, which uses accelerometers and gyroscopes, deteriorates with time. An external aiding sources such as the Global Positioning System (GPS) can be employed to reduce the error growth...
-
QUASI-DISTRIBUTED NETWORK OF LOW-COHERENCE FIBER-OPTIC FABRY-PÉROT SENSORS WITH CAVITY LENGTH-BASED ADDRESSING
PublicationDistributed measurement often relies on sensor networks. In this paper, we present the construction of low coherent fiber-optic Fabry-Pérot sensors connected into a quasi-distributed network. We discuss the mechanism of spectrum modulation in this type of sensor and the constraints of assembly of such sensors in the network. Particular attention was paid to separate the signals from individual sensors, which can be achieved by...
-
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublicationA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Data fusion of GPS sensors using Particle Kalman Filter for ship dynamic positioning system
PublicationDepending on standards and class, dynamically positioned ships make use of different numbers of redundant sensors to determine current ship position. The paper presents a multi-sensor data fusion algorithm for the dynamic positioning system which allows it to record the proper signal from a number of sensors (GPS receivers). In the research, the Particle Kalman Filter with data fusion was used to estimate the position of the vessel....
-
Application of optical microsphere in fiber optic sensors for measurement of electrochemical processes
Open Research Datainvestigation of the electrochemical processes using micro-sphere fiber-optic sensor with a zinc oxide (ZnO) coating applied by Atomic Layer Deposition method (ALD). The measurements were performed in 1M KNO3 during a decomposition of Bisphenol-A
-
Formaldehyde detection with chemical gas sensors based on WO3 nanowires decorated with metal nanoparticles under dark conditions and UV light irradiation
PublicationWe report results of formaldehyde gas (CH2O) detection under dark conditions and UV light irradiation with pristine tungsten trioxide nanowires (WO3 NWs) and metal nanoparticles decorated WO3 NWs gas sensing layers. The resistive layers were deposited by one step aerosol assisted chemical vapor deposition (AACVD) on commercial alumina substrates with 10-pair interdigitated platinum electrodes. The elaborated gas sensors, based...
-
An optimised placement of the hard quality sensors for a robust monitoring of the chlorine concentration in drinking water distribution systems
PublicationThe problem of an optimised placement of the hard quality sensors in drinking water distribution systemsunder several water demand scenarios for a robust monitoring of the chlorine concentration is formulatedin this paper. The optimality is understood as achieving a desired trade off between the sensors and theirmaintenance costs and the accuracy of estimation of the chlorine concentration. The contribution of thiswork is a comprehensive...
-
SU‐FF‐T‐209: New Polymer Gel Dosimeter with High Refractive Index for Artifact‐Free Optical CT Scanning
Publication -
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Investigation of sensing mechanism of Nasicon electrocatalytic sensors in nitrogen dioxide and ammonia
PublicationIn this paper a sensing mechanism of Nasicon electrocatalytic sensor in nitrogen dioxide and ammonia is investigated. Both gases are environmentally hazardous and contain nitrogen atom in the molecule. However, it seems that their sensing mechanism in electrocatalytic sensor could be totally different. Namely, the maximum sensitivity for each gas was obtained at different temperatures. Also, different auxiliary layers are formed...
-
An Ultra-Low-Energy Analog Comparator for A/D Converters in CMOS Image Sensors
PublicationThis paper proposes a new solution of an ultra-low-energy analog comparator, dedicated to slope analog-to-digital converters (ADC), particularly suited for CMOS image sensors (CISs) featuring a large number of ADCs. For massively parallel imaging arrays, this number may be as high as tens-hundreds of thousands ADCs. As each ADC includes an analog comparator, the number of these comparators in CIS is always high. Detailed analysis...
-
Energy requirements for methods improving gas detection by modulating physical properties of resistive gas sensors
PublicationAbstract. One of the most important disadvantage of resistive gas sensors is their limited gas selectivity. Therefore, various methods modulating their physical properties are used to improve gas detection. These methods are usually limited to temperature modulation or UV light irradiation for the layers exhibiting photocatalytic effect. These methods cause increased energy consumption. In our study we consider how much energy...
-
Interferometric optical fiber sensors with active stabilization of the operating point using a tunable semiconductor laser. Optical Fibres and Their Applications VIII.
PublicationW pracy przedstawiono wyniki badań światłowodowych interferometrycznych sensorów siły wykonanych w konfiguracji interferometru Michelsona i wykorzystujących aktywną stabilizację punktu pracy przy pomocy zmiany długości fali źródła. Porównano dwie klasy omawianych sensorów a następnie zrealizowano sensor. W konstrukcji sensora zastosowano modulator z pośrednim pomiarem siły. Mierzona siła jest zamieniana na ciśnienie hydrostatyczne,...
-
Uncertainty Quantification of Additive Manufacturing Post-Fabrication Tuning of Resonator-Based Microwave Sensors
PublicationReconfigurability, especially in terms of the ability of adjusting the operating frequency, has become an important prerequisite in the design of modern microwave components and systems. It is also pertinent to microwave sensors developed for a variety of applications such as characterization of material properties of solids or liquids. This paper discusses uncertainty quantification of additive-manufacturing-based post-fabrication...
-
Interface circuit for impedance sensors using two specialized single-chip microsystems
PublicationW artykule przedstawiono obwód interfejsu przeznaczony do pomiaru parametrów impedancyjnych czujników lub celek pomiarowych instalowanych na obiektach technicznych. Umożliwia on pomiar modułu i argumentu impedancji w zakresie 10ohm
-
Katania, 2023, Road SS114 – csv data from sensors on bicycle
Open Research DataData collected with bicycle-mounted sensors on 06.07.2023 while cycling on the cycle path along the SS114 road in Catania. The data includes parameters such as: gps coordinates- txt files, brain waves and heart rate- csv file.
-
Non-Gaussian Resistance Fluctuations in Gold-Nanoparticle-Based Gas Sensors: An Appraisal of Different Evaluation Techniques
PublicationVolatile organic compounds, such as formaldehyde, can be used as biomarkers in human exhaled breath in order to non-invasively detect various diseases, and the same compounds are of much interest also in the context of environmental monitoring and protection. Here, we report on a recently-developed gas sensor, based on surface-functionalized gold nanoparticles, which is able to generate voltage noise with a distinctly non-Gaussian...
-
Reduced graphene oxide doping with nanometer-sized ferrocene moieties – New active material for glucose redox sensors
Publication -
Modal structure design in refractive capillary optical fibers
Publication -
Two classes of capillary optical fibers: refractive and photonic
Publication -
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublicationElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Integration of inertial sensors and GPS system data for the personal navigation in urban area
PublicationGPS and Inertial Navigation Systems (INS) have complementary properties and they are therefore well suited for integration. The integrated solution offers better long-term accuracy than a stand-alone INS and better integrity, availability and continuity or a stand-alone GPS receiver, making it suitable for demanding applications. The complementary features of INS and GPS are the main reasons why integrated GPS/INS systems are becoming...
-
Nano-porous alumina humidity sensors
PublicationW pracy przedstawiono wyniki badań czujników wilgotności przygotowanych na bazie porowatej aluminy.
-
Fluctuation phenomena in semiconductor gas sensors
PublicationCzujniki gazu mogą być wytwarzane z cienkiej warstwy półprzewodnika, która po podgrzaniu do odpowiedniej temperatury staje się czuła na gaz. Zjawisko to jest dobrze znane i szeroko opisane w literaturze. Jako wskaźnik detekcji gazu wykorzystuje się zmianę rezystancji stałoprądowej czujnika. Zwiększenie czułości i, co najważniejsze z praktycznego punktu widzenia, selektywności dyskryminacji można uzyskać jeśli warstwa półprzewodnika...
-
Tools for signal analysis of gas sensors
PublicationStatystyki drugiego rzedu oraz jklasyczna analiza widmowa są zwykle stosowane do badania sygnałów losowych o rozkładzie gaussowskim. Są one jednak często nieodpowiednie w przypadku analizy niestacjonarnych sygnałów niegaussowskich. Pewne narzędzia do analizy takich sygnałów sa dostępne w bibliotekach środowiska MATLAB. Zostały one wykorzystane do do analizy fluktuacji sygnałów czujników gazów. W artykule przedstawiono system do...
-
Materials for potentiometric electrochemical gas sensors
PublicationPublikacja przeglądowa na temat zasady działania oraz rodzajów czujników elektrochemicznych gazów.
-
The silver layers in fiber-optic sensors
PublicationIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
Gas sensors based on superionic conductors
PublicationW pracy przedstawiono przegląd rozwiązań elektrochemicznych czujników gazów na bazie elektrolitów stałych.
-
On the selectivity of nanostructured semiconductor gas sensors
Publication.
-
Solid-state electrochemical gas sensors
PublicationW pracy przedstawiono budowę i zasadę działania wybranych typów elektrochemicznych czujników gazów zbudowanych na bazie elektrolitów stałych.
-
Density, sound velocity, viscosity, and refractive index of new morpholinium ionic liquids with amino acid-based anions: Effect of temperature, alkyl chain length, and anion
PublicationIn this work, room temperature synthesis of twenty new ionic liquids (ILs) based on the N-alkyl-N-methylmorpholinium ([Mor1,R], R = 2, 3, 4, 6, 8) cation and N-acetyl-L-amino acid anions (L-alaninate, L-valinate, L-leucinate, L-isoleucinate) was described. The synthesized ILs were characterized by various spectroscopic techniques and high-resolution mass spectrometry. Furthermore, density (ρ), sound velocity (v), viscosity (η)...
-
Metal-Organic Frameworks-Based Sensors for the Detection of Toxins in Food: A Critical Mini-Review on the Applications and Mechanisms
PublicationUsing scientific technologies to detect toxins in food is significant to prevent food safety problems and protect people’s health. Recently, the rise of sensors has made rapid, efficient, and safe detection of food toxins possible. One of the key factors impacting the sensor’s performance is the nanomaterials employed. Metal-organic frameworks (MOFs), with high specific surface area, tunable composition, porous structure, and flexible...
-
Benchmarking Scalability and Security Configuration Impact for A Distributed Sensors-Server IOT Use Case
PublicationInternet of Things has been getting more and more attention and found numerous practical applications. Especially important in this context are performance, security and ability to cope with failures. Especially crucial is to find good trade-off between these. In this article we present results of practical tests with multiple clients representing sensors sending notifications to an IoT middleware – DeviceHive. We investigate performance...
-
Inverse Modeling and Optimization of CSRR-based Microwave Sensors for Industrial Applications
PublicationDesign optimization of multivariable resonators is a challenging topic in the area of microwave sensors for industrial applications. This paper proposes a novel methodology for rapid re-design and parameter tuning of complementary split-ring resonators (CSRRs). Our approach involves inverse surrogate models established using pre-optimized resonator data as well as analytical correction techniques to enable rapid adjustment of geometry...
-
Journal of Sensors and Sensor Systems
Journals -
Chinese Journal of Sensors and Actuators
Journals -
Journal of Medical Signals and Sensors
Journals -
IEEJ Transactions on Sensors and Micromachines
Journals -
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
Optimised Allocation of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised placement of the hard quality sensors in Drinking Water Distribution Systems for robust quality monitoring is formulated. Two numerical algorithms to solve the problem are derived. The optimality is meant as achieving a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm. The robust estimation algorithm recently developed...
-
Real-time working gas recognition system based on the array of semiconductor gas sensors and portable computer Raspberry PI
PublicationThe gas-analyzing systems based on the array of partially selective gas sensors and pattern-recognition techniques are potentially fast and low-cost alternative for other devices, like gas analysers. They give the possibility of recognition the type and the concentration of measured volatile compounds in their working environment. In this work we present the implementation of gas recognition system, in which the signals from an...
-
Grzegorz Lentka dr hab. inż.
PeopleGrzegorz Lentka obtained his MSc title in electronics, specialization Measurement Systems at Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics in 1996. He obtained the PhD title in 2003 and habilitation in 2014, respectively. Currently he is an professor in Department of Metrology and Optoelectronics. His main scientific interests are focused on digital signal processing for metrology,...
-
Embedded system using Bluetooth Low Energy sensors for smart farming applications
PublicationThe main goal of this Bachelor of Engineering project titled Embedded system using Bluetooth Low Energy sensors for smart farming applications is to create a prototype of a system consistent with Agriculture 4.0 concept using Bluetooth Low Energy (BLE) technology. Developed solution shall be easy in implementation and its main functionality shall be periodic gathering of data from environmental sensors...
-
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublicationOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...
-
Monitoring Parkinson's disease patients employing biometric sensors and rule-based data processing
PublicationArtykuł prezentuje automatyczny system wykrywania pogorszenia zdrowia pacjentów z chorobą Parkinsona opracowany w ramach projektu PERFORM.The paper presents how rule-based processing can be applied to automatically evaluate the motor state of Parkinson's Disease patients. Automatic monitoring of patients by using biometric sensors can provide assessment of the Parkinson's Disease symptoms. All data on PD patients' state are compared...
-
Computational complexity and length of recorded data for fluctuation enhanced sensing method in resistive gas sensors
PublicationThis paper considers complexity and accuracy of data processing for gas detection using resistance fluctuation data observed in resistance gas sensors. A few selected methods were considered (Principal Component Analysis – PCA, Support Vector Machine – SVM). Functions like power spectral density or histogram were used to create input data vector for these algorithms from the observed resistance fluctuations. The presented considerations...