Filters
total: 868
Search results for: ORIENTED POROUS SCAFOLD
-
Horizontal flow boiling of refrigerants inside porous coated tube.
PublicationPrzedstawiono wyniki badań przejmowania ciepła i spadku ciśnienia podczas wrzenia czynników chłodniczych R22, R134a i R407C w poziomej rurce z wewnętrzną powłoką porowatą.
-
Organic Acids and Polyphenols Determination in Polish Wines by Ultrasound-Assisted Solvent Extraction of Porous Membrane-Packed Liquid Samples
PublicationIn the near future, Poland is going to have more and more favorable conditions for viticulture. Organic acids and polyphenols are among the most commonly analyzed compounds due to their beneficial properties for human health and their importance in the winemaking process. In this work, a new technique involving ultrasound-assisted solvent extraction of porous membrane-packed liquid samples (UASE-PMLS) was for the first time described...
-
Simulation-driven size-reduction-oriented design of multi-band antennas by means of response features
PublicationThis study addresses the problem of explicit size reduction of multi-band antennas by means of simulation-driven optimisation. The principal difficulty of electromagnetic (EM)-based miniaturisation of multi-band antennas is that several resonances have to be controlled independently (both in terms of their frequency allocation and depth) while attempting to reduce physical dimensions of the structure at hand. The design method...
-
Design-oriented modeling of antenna structures by means of two-level kriging with explicit dimensionality reduction
PublicationThe employment of full-wave electromagnetic (EM) analysis is a practical necessity in the design of contemporary antenna structures. This is because simpler models are generally not available or of limited accuracy. At the same time, EM-based design is computationally expensive. Consequently, the ways of accelerating tasks such as parametric optimization or uncertainty quantification have to be sought. A possible workaround that...
-
High-density Polyethylene - Expanded Perlite Composites: Structural Oriented Analysis of Mechanical and Thermomechanical Properties
PublicationAs part of this work, research was carried out on the effect of the addition of expanded perlite (PR) on the mechanical and thermomechanical properties of high-density polyethylene (PE) composites. Composites containing from 1 to 10 wt% of the inorganic filler were produced. Polyethylene-based composites manufactured by twin-screw extrusion and formed in the compression molding process were subjected to mechanical, thermomechanical,...
-
Essentials and Perspectives of Computational Modelling Assistance for CNS-oriented Nanoparticle-based Drug Delivery Systems
Publication -
SEM image and line EDS of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with line EDS analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 20 kV in a high vacuum mode. The chemical compositions of the investigated powder...
-
Series resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces area.
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.50Fe0.50O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.50Fe0.50O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.30Fe0.70O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Structural and electrical properties of Cr-doped SrTiO 3 porous materials
PublicationSeries of single-phase materials with assumed formula SrTi1−xCrxO3 (where x = 0, 1, 4, 6 mol.%) were obtained by sol-gel method. The structure and microstructure of materials were characterised by X-ray diffraction and scanning electron microscopy methods. Moreover, the study of electrical properties and evaluation of chemical stability in CO2/H2O atmosphere was performed by electrochemical impedance spectroscopy and thermogravimery...
-
Computer-aided design and selective laser melting of porous biomimetic materials
Publication -
Porous Selective Laser Melted Ti and Ti6Al4V Materials for Medical Applications
Publication -
Evaluation of porous 430L stainless steel for SOFC operation at intermediate temperatures
PublicationW pracy przedstawiono badania porowatej stali nierdzewnej typu 430L do zastosowań w tlenkowych ogniwach paliwowych jako podłoża. Podłoża były poddawane utlenianiu w powietrzu oraz w wodorze i analizowane z wykorzystaniem mikroskopu elektronowego, dyfrakcji rentgenowskiej i termograwimetrii cyklicznej.
-
From polystyrene waste to porous carbon flake and potential application in supercapacitor
Publication -
Pool boiling of water-Al2O3 nanofliud on horizontal porous coated tube
PublicationPrzedstawiono wyniki badań przejmowania ciepła podczas wrzenia w dużej objętości nanocieczy woda-Al2O3 na poziomej rurce z aluminiową powłoką porowatą o grubości 0.15 mm i porowatości 40%. Koncentracja nanocząstek wnosiła 0.01%, 0.1% oraz 1%. Niezależnie od koncentracji współczynnik przejmowania ciepła przy wrzeniu nanocieczy był niższy niż przy wrzeniu wody destylowanej.
-
Preliminary Studies on a Lightweight Porous Cement-Based Composite – Gel Concrete
Publication -
Aquatic biomass containing porous silica as an anode for lithium ion batteries
PublicationA composite electrode was manufactured by pyrolysis of Red Algae (Polysiphonia fucoides) covered by diatoms (Diatomophyceae). Electrodes were tested as a half cell with capacity of 500 mA h g−1 after 80 cycles. XPS analysis shows formation of lithium silicate under reduction of silica in an aprotic electrolyte containing LiPF6 salt.
-
The structure of porous and spontaneously densified amorphous PbSiO3: a Molecular Dynamics study.
PublicationW pracy zaproponowano nową metodę numerycznego otrzymywania strukturporowatych metodą dynamiki molekularnej. Metoda polega na rozpoczęciu symulacji z ładunkami ekranowanymi i stopniowym zwiększaniu ich do pełnych ładunków jonowych. Metodę zastosowano do układu PbSiO3.
-
Analysis of different approaches of capillary rise method for characterization of porous materials
PublicationPomiar kąta zwilżania materiałów porowatych metodą wzniesienia kapilarnego został opisany przez wielu badaczy, jakkolwiek problem ten jest wciąż dyskutowany. Niniejsza praca dotyczy oceny wzniesienia kapilarnego za pomocą równania Washburn'a. Wykonano badania oparte na pomiarze masy i wysokości lustra cieczy zwilżającej w funkcji czasu wzniesienia w złożu wykonanym z kulek szklanych. Uzyskane wyniki były analizowane z użyciem równania...
-
Determination of Local Dye Concentration in Hybrid Porous Silica Thin Films
PublicationThe idea of determination of local dye concentration in a nanoporous matrix is proposed based on donor − acceptor energy transfer. The method was tested for a Rhodamine 110 − Rhodamine 101 system in silica and methylated silica nanolayers. Evaluation of acceptor (Rhodamine 101) local concentration was carried out by comparing the results of Monte Carlo simulation of energy transfer from donor (Rhodamine 110) to acceptor (Rhodamine...
-
Electrochemical Activity of Electrode Material Consisting of Porous Copper and Silica Aerogel
PublicationElectrochemically obtained copper was combined with silica aerogel (SiO2ag). Obtained composite (SiO2@Cu/CuxOy) was tested as an electrode in contact with LiPF6 in EC/DMC electrolyte. The electrochemical measurements showed the presence of complex redox couple activities of SiO2@Cu/CuxOy. This experiment was employed to help in understanding the carbon role used as an electric contact for silica in Li-Ion batteries and clarify...
-
Ultrasound-Assisted Solvent Extraction of a Porous Membrane Packed Sample for the Determination of Tobacco-Specific Nitrosamines in the Replacement Liquids for E-Cigarettes
PublicationThe content of tobacco-specific nitrosamines (TSNAs) possessing carcinogenic properties has been an important area of research since replacement liquids were introduced for e-cigarettes. A method for determining N′-nitrosonornicotine (NNN), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N′-nitrosoanatabine (NAT), and N′-nitrosoanabasine (NAB) in replacement liquids for electronic cigarettes was developed using liquid chromatography–tandem...
-
SEM image and EDS map of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with EDS map analysis results. This study were performed for better understanding the chemical composition of flat like structures that occurs in electrode. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope...
-
Jacek Rak dr hab. inż.
PeopleJacek Rak uzyskał stopień doktora habilitowanego nauk technicznych w dyscyplinie telekomunikacji (specjalność: teleinformatyka) w 2016 r., a stopień doktora nauk technicznych w dyscyplinie informatyka w 2009 r. Obecnie jest pracownikiem naukowo-dydaktycznym Katedry Teleinformatyki Wydziału Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej. Jego działalność naukowa koncentruje się w obszarze doboru tras, projektowania...
-
Area specific resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces...
-
Effect of sintering temperature on electrochemical performance of porous SrTi1-xFexO3-δ (x = 0.35, 0.5, 0.7) oxygen electrodes for solid oxide cells
PublicationThis work evaluates the effects of the sintering temperature (800 °C, 900 °C, 1000 °C) of SrTi1-xFexO3-δ (x = 0.35, 0.5, 0.7) porous electrodes on their electrochemical performance as potential oxygen electrode materials of solid oxide cells. The materials were prepared by a solid-state reaction method and revealed the expected cubic perovskite structure. After milling, the powders were characterised by a sub-micrometre particle...
-
Assessment with mechanical Barkhausen effect of residual stress in grain oriented polycrystalline 3% Si-Fe sheet
PublicationW tym artykule zostały opisane badania naprężeń resztkowych w blachach wykonanych z 3% si-fe o zorientowanym ziarnie za pomocą mechanicznego efektu barkhausena (mebn). badano blachy o 3 różnych orientacjach ziaren względem głównej osi próbki: 0, 45, 90 stopni. badania mebn przeprowadzano wzbudzając drgania skrętne oraz drgania gięte. zmierzone maksima obwiedni napięcia skutecznego mebn znajdują się dla badanych próbek w regionie...
-
Assessment with mechanical Barkhausen effect of residual stress in grain oriented polycrystalline 3% Si-Fe sheet
PublicationZbadano za pomocą mechanicznego efektu Barkhausena poziom napręzeń wewnętrznych w plikrystalicznej płycie z 3% Si-Fe o zorientowanym ziarnie.
-
Excitation energy migration in uniaxially oriented polymer films: a comparison between strongly and weakly organized systems
PublicationMechanizm wieloetapowej migracji energii w osiowo rozciąganych foliach polimerowych jest analizowany w układach o silnej i słabej orientacji molekuł barwników umieszczonych w matrycach poliwinylowych. Porównanie tych różnie orientujących się układów bazuje na zjawisku depolaryzacji stężeniowej anizotropii emisji, symulacjach Monte Carlo i wartościach liniowego dichroizmu. Pokazano, że uporządkowanie momentów przejścia fluoroforów...
-
A performance-oriented risk-based method for assessment of safety of ships. Modelling uncertainties in hazard and risk analysis
PublicationW artykule podano informacje na temat alternatywnej metody oceny bezpieczeństwa statków, opartej na ocenie zachowania się statku i ocenie ryzyka. Zaproponowano użycie metody do projektowania statków w oparciu o ocenę ryzyka. W takim podejściu do projektowania bezpieczeństwo powinno być celem projektowym. Ocena bezpieczeństwa w proponowanej metodzie powinna być dokonywana na podstawie oceny ryzyka. Do oceny ryzyka zastosowano elementy...
-
Brittle fracture of 100-, 110-, 111-oriented Cu crystals: MD vs. TB/MD approach
PublicationPrzeprowadzono wieloskalowe symulacje nanoindentacji miedzi nieskończenie twardym narzędziem, przy zastosowaniu metody dynamiki molekularnej, z siłami liczonymi na bieżąco w formalizmie ciasnego wiązania (TB). Przedstawiono wyniki dla trzech orientacji krystalicznych podłoża. Badano efekt dołączenia obliczeń TB na siłę normalną odczuwaną przez narzędzie i na przemieszczenia atomów podłoża, przez porównywanie z symulacją czystą...
-
Aggregation and excitation trapping of 3,3'-diethyl-9-methylthiacarbocyanine iodide in disordered and uniaxially oriented polymer films
PublicationPrzedstawiono analizę właściwości fotofizycznych barwnika 3,3'-diethyl-9-methylthiacarbocyanine iodide (MDTCI)domieszkowanego w zakresie dużych koncentracji w nieuporządkowanych osiowo rozciąganych foliach polimerowych. Zaobserwowano obecność fluoryzujących agregatów MDCTI zarówno w foliach nierozciąganych i rozciąganych stosując metody spektroskopii czasowo-rozdzielonej.
-
Dirk Dreheim, Gerald Weber: Form-oriented analysis : a new methodology to model form-based applications
PublicationArtykuł stanowi omówienie nowej metodyki modelowania interfesu użytkownika, przeznaczonej do projektowania aplikacji opartych na pracy z formularzami elektronicznymi. Metodyka ta, przedstawiona w książce Dreheima i Webera, stanowi interesującą notacje graficzną, która umożliwia projektowanie interfejsu użytkownika o wysokich własciwościach ergonomicznych i użytkowych. Szczególnie interesujace sa w tej metodyce możliwości elastycznego...
-
Photocatalytic degradation and pollutant-oriented structure-activity analysis of carbamazepine, ibuprofen and acetaminophen over faceted TiO2
PublicationPhotocatalytic degradation of carbamazepine, ibuprofen, acetaminophen and phenol was studied in the presence of anatase photocatalyst, exposing three different crystal facets in the majority of {0 0 1}, {1 0 0} or {1 0 1}. It was found that octahedral anatase particles exposing {1 0 1} facets allow to achieve the best degradation and mineralization of all persistent organic pollutants. This confirms that the previous findings,...
-
CO2 uptake capacities of PCMCA-900 (potassium citrate-derived porous carbon prepared at 900 °C) adsorbent at various temperatures
Open Research DataThese data contain CO2 uptake capacities of PCMCA-900 (potassium citrate-derived porous carbon prepared at 900 °C) adsorbent at various temperatures. Adsorption experiments were carried out at temperatures 0 °C, 25 °C, and 50 °C at 1 bar.
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.50Fe0.50O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.50Fe0.50O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.30Fe0.70O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
JOURNAL OF POROUS MATERIALS
Journals -
JOURNAL OF POROUS MEDIA
Journals -
TRANSPORT IN POROUS MEDIA
Journals -
Influence of sintering temperature of porous SrTi0.30Fe0.70O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Influence of sintering temperature of porous SrTi0.50Fe0.50O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Influence of sintering temperature of porous SrTi0.65Fe0.35O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublicationIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...