Filters
total: 1501
displaying 1000 best results Help
Search results for: WATER CAPSULE AIRDROP CONTROL SYSTEM
-
Integrated monitoring, control and security of Critical Infrastructure Systems
PublicationModern societies have reached a point where everyday life relies heavily on desired operation of critical infrastructures, in spite of accidental failures and/or deliberate attacks. The issue of desired performance operation of CIS at high security level receives considerable attention worldwide. The pioneering generic methodologies and methods are presented in the paper project for designing systems capable of achieving these...
-
Zintegrowane sterowanie systemami zaopatrzenia w wodę pitną
PublicationOptymalne ekonomicznie zaspokojenie w miastach bieżącego zapotrzebowania na wodę pitną tak, aby spełnione były wymagania jakości dostaw oraz jakości samej wody jest złożonym zadaniem. Zarówno aspekty aplikacyjne jak i teoretyczne tego problemu są przedmiotem intensywnych prac prowadzanych w sektorach naukowych i przemysłowych na całym świecie. Prace te finansowane są przez przemysł, komitety naukowe oraz Programy Ramowe Unii Europejskiej....
-
Stormwater runoff in the urbanized coastal basin of Gdańsk Urbanized basin of Gdańsk
PublicationAnthropopressure strongly affects the primal water cycle. Alternation of the natural basins imposes changes of drainage patterns, reduction of bioretention, infiltration and base flow. As a result the overland flow predominates and greater runoff rates flow into storm water collection systems and reservoirs. Moreover changing climatic conditions increase the frequency of rapid extreme weather events. Infrastructures of urban areas...
-
Krzysztof Armiński dr inż.
PeopleKrzysztof Armiński received his PhD in Control System Enginiering from the Gdańsk University of Technology in 2014 Currently he is a assistant professor of Control Enginiering at the Gdańsk University of Technology. His research interests are in the field of set bounded state estimation and modeling for control purpose.
-
Robust Parameter Estimation and Output Prediction for Reactive Carrier-Load Nonlinear Dynamic Networks
PublicationIn this paper an extension of on-line model simplification technique for a class of networked systems, namely reactive carrier-load nonlinear dynamic networked system (RCLNDNS), kept within point-parametric model (PPM) framework is addressed. The PPM is utilised to acquire a piece wise constant time-varying parameter linear structure for the RCLNDNS suitable for the on-line one step ahead prediction that may be applied to monitoring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
On the problem of optimised allocation of water quality sensors and actuators in DWDS
PublicationThe problems of water quality sensors and actuators placement in drinking water distribution systems (DWDSs) are addressed as separate, primarily. However, against the background of control systems theory, the nature of DWDSs dynamics indicates that these both problems are interdependent and impact the design of related water quality monitoring and control structures and algorithms. The research work presented in this paper is...
-
Cooperative control in production and logistics
PublicationClassical applications of control engineering and information and communication technology (ICT) in production and logistics are often done in a rigid, centralized and hierarchical way. These inflexible approaches are typically not able to cope with the complexities of the manufacturing environment, such as the instabilities, uncertainties and abrupt changes caused by internal and external disturbances, or a large number and variety...
-
ECG measurement in the bathtub - drl on one side of the bathtub, the other side of the bathtub is grounded and the system ground is grounded- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
PublicationIn this paper, a tuning method of a resonant circuit suited for wireless powering of miniature endoscopic capsules is presented and discussed. The method allows for an automatic tuning of the resonant frequency and matching impedance of a full wave rectifier loading the resonant circuit. Thereby, the receiver tunes so as to obtain the highest power efficiency under given conditions of transmission. A prototype receiver for wireless...
-
Leakage detection and localisation in drinking water distributionnetworks by MultiRegional PCA
PublicationMonitoring is one of the most important steps in advanced control of complex dynamic systems. Precise information about systems behaviour, including faults indicating, enables for efficient control. The paper describes an approach to detection and localisation of pipe leakage in Drinking Water Distribution Systems (DWDS) representing complex and distributed dynamic system of large scale. Proposed MultiRegional Principal Component...
-
The adaptive backstepping control of PMSM supplied by current source inverter for the field weakening region
PublicationThe sensorless control system of permanent magnet synchronous motor PMSM supplied by current source inverter for field weakening operation is presented in this paper. The adaptive backstepping control system and the backstepping speed observer are presented. The control system is based on multi-scalar variables. The control variables are: dc-link voltage and the output current vector pulsation. The control system was named voltage...
-
Control of induction machine supplied by a current source inverter using the multi-scalar transformation and backstepping approach
PublicationThe paper describes the voltage control technique of squire-cage induction machines supplied by a current source inverter. The control system is based on new transformation of the electric drive system (machine and inverter) state variables to the multi-scalar variables form. The backstepping approach is used to obtain the feedback control law. The control system contains the structure of the observer...
-
Sensorless control of five-phase induction machine supplied by the VSI with output filter
PublicationIn this paper, a novel sensorless control structure based on multi-scalar variables is proposed. The tatic feedback control law is obtained by using the multi-scalar variables transformation, where the multi-scalar variables approach allows a full linearization of the nonlinear system. The control system could be described as “optimized” because of the minimized number of controllers. Furthermore, control system is divided into...
-
Synthesis of a state feedback controller for an averaging tank with variable filling
PublicationIn paper, a nonlinear averaging tank with variable filling is considered. The main purpose of this research work was the modelling and control system synthesis of an averaging tank. The control objectives included ensuring stability and zero steady-state error of the system and achieving settling time as short as possible, while maintaining a minimal overshoot. In order to achieve the intended purpose, firstly a mathematical model...
-
Dynamic variables limitation for backstepping control of induction machine and voltage source converter
PublicationDynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...
-
Stormwater and snowmelt runoff storage control and flash flood hazard forecasting in the urbanized coastal basin.
PublicationCity of Gdańsk is located in a coastal region where changing climatic conditions increase the frequency of extreme weather events. Developing urbanization affects the hydrology of natural basins by simplification of the drainage system and reduction of infiltration and base flow. Consequently greater runoff rates flow into storm water collection systems, reservoirs and surrounding water bodies. Not only infrastructures of urban...
-
Design of three control algorithms for an averaging tank with variable filing
PublicationAn averaging tank with variable filling is a nonlinear multidimensional system and can thus be considered a complex control sys-tem. General control objectives of such object include ensuring stability, zero steady state error and achieving simultaneously shortest possible settling time and minimal overshoot. The main purpose of this research work was the modelling and synthesis of three control systems for an averaging tank. In...
-
Krzysztof Goczyła prof. dr hab. inż.
PeopleKrzysztof Goczyła, full professor of Gdańsk University of Technology, computer scientist, a specialist in software engineering, knowledge engineering and databases. He graduated from the Faculty of Electronics Technical University of Gdansk in 1976 with a degree in electronic engineering, specializing in automation. Since then he has been working at Gdańsk University of Technology. In 1982 he obtained a doctorate in computer science...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Optimising approach to designing kernel PCA model for diagnosis purposes with and without a priori known data reflecting faulty states
PublicationFault detection plays an important role in advanced control of complex dynamic systems since precise information about system condition enables efficient control. Data driven methods of fault detection give the chance to monitor the plant state purely based on gathered measurements. However, they especially nonlinear, still suffer from a lack of efficient and effective learning methods. In this paper we propose the two stages learning...
-
ECG measurement in the bathtub - getting into the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Sensorless Control of Induction Machine Supplied by Current Source Inverter
PublicationThe paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.
-
Control Strategy of a Five-Phase Induction Machine Supplied by the Current Source Inverter With the Third Harmonic Injection
PublicationIn the five-phase induction machine (IM), it is possible to better use the electromagnetic circuit than in the three-phase IM. This requires the use of an adequate converter system which will be supplied by an induction machine. The electric drive system described, in this article, includes the five-phase induction machine supplied by the current source inverter (CSI). The proposed novelty—not presented previously—is the control...
-
The results of physico – chemical monitoring of watercourses around the municipality of Gdańsk in 2016
Open Research DataThe dataset contains the results of a physico-chemical study of watercourses waters within the administrative boundaries of Gdańsk city in 2016. The examined material consisted of water samples collected from 16 watercourses (5 rivers, 6 streams, 2 storm water sewers, 1 artificial canal, 1 artificial arm of a river and 1 drainage trench) flowing directly...
-
Nonlinear fuzzy control of the dissolved oxygen in activated sludge processes
PublicationWastewater treatment plant is generally a complex, multivariable, time varying and nonlinear large scale industrial system. Moreover, interactions between the components are very strong. The dissolved oxygen tracking problem is one of the most complex and fundamental issues of biological processes. Air for the aerated tanks is supplied by aeration system (blowers, pipes, diffusers). It is a complex dynamic system. The new control...
-
The Application of the Thermal Stabilization Prompted by the Ice Cover Expansion Considering the Energy Production Optimization in the Dam-Reservoir Coupled Systems on the Vistula River
PublicationIn this study, the thermal stabilization of a water resource together with an energy production optimization in the power plant of the dam–reservoir coupled system is conducted. This coupled dam system is designed to consist of a primary (Włocławek) and secondary (Siarzewo) dam due to the erosion control aspect. The other beneficial aspect of this coupled dam design is to have an additional power plant, with the aim of achieving...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...