Search results for: LIGHTNING PROTECTION EARTHINGEARTHING IMPEDANCE MEASUREMENTIMPULSE IMPEDANCEEARTHING IMPEDANCE
-
Impulse Impedance Measurements of Lightning Protection Earthings
PublicationLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
Kazimierz Darowicki prof. dr hab. inż.
PeopleStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Influence of test procedure on surge impedance of lightning earthings.
PublicationUziemienia systemu ochrony odgromowej powinny być badane prądami o parametrach czasowych podobnych do rejestrowanych podczas wyładowań atmosferycznych.Podano definicję impedancji i warunki jej pomiaru. omówiono pojęcie długości efektywnej uziomu.
-
Polynomial description of dynamic impedance spectrogram—introduction to a new impedance analysis method
PublicationThis paper presents a polynomial description of spectrograms obtained using Dynamic Electrochemical Impedance Spectroscopy. A method to fit the polynomial degree correctly is discussed. A simple electrical system of a diode connected in parallel with a capacitor was used for testing. Dynamic impedance measurements during potentiodynamic polarization were conducted. This paper presents an alternative analysis method that allows...
-
Polynomial analysis as a new way of describing dynamic impedance spectra – Differential and relative impedance spectra
PublicationModel measurements of an equivalent electrical system were carried out using the technique of Dynamic Electrochemical Impedance Spectroscopy. The measurement took the form of potentiodynamic changes imposed on the tested system. Using the possibility of continuous impedance measurements, an attempt was made to develop an original and innovative method of analyzing impedance spectrograms, which is termed polynomial analysis. As...
-
Platform Supporting the Esophageal Impedance Analysis
PublicationThe esophageal pH-impedance examination is one of the most popular diagnostic methods for identifying the upper gastrointestinal tract’s diseases. Inconclusive test evaluation criteria makes it difficult to state the definite diagnosis. In this paper, the computer platform supporting the research and teaching process in the area of pH-impedance analysis is presented. Users, having a variety of mathematical and statistical methods...
-
A Comprehensive Analysis of Impedance of the Electrochemical Cell
PublicationA comprehensive impedance characteristics of two electrodes electrochemical cell has been pre sented. In this method a multisinusoidal current excitation signal is used. The change of potential of both the electrodes are all registered as a function of time. The proposed method gives the possibility of determining the impedance of both electrodes individually as well as the impedance of a twoelectrode system. Additional application...
-
Characterization of Bi6Fe2Ti3O18 Ceramics with Impedance Spectroscopy
PublicationIn the present research the tool of impedance spectroscopy was utilized to characterize dielectric behavior of Aurivillius-type ceramics of Bi6Fe2Ti3O18 composition fabricated by hot pressing method from the stoichiometric mixture of oxides Bi2O3, TiO2 and Fe2O3. Impedance spectroscopy was applied to characterize dielectric response of bulk, grain boundary, and material/electrode interfaces of the fabricated polycrystalline ceramic...
-
Impedance evaluation of coatings from biobased material
PublicationThe authors propose a modification of sodium caseinate edible coating for foodstuff protection. The aim was to improve the film’s barrier properties. It was achieved by the addition of propolis, which is a natural, environmentally friendly product known from its intrinsic sealing action. In the next step, propolis-admixed sodium caseinate films were exposed to elevated temperature for 10 min. This approach was meant to improve...
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Selection of excitation signals for high-impedance spectroscopy
PublicationA method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 GOhm) is evaluated in this paper. An object is excited with a signal generated by a digital-to-analog converter (DAC) located on the U2531A DAQ module. Response signals proportional to current flowing through and voltage across the measured object are sampled by analog-to-digital converters (ADC) in the DAQ module. The object impedance spectrum...
-
Impedance monitoring of fuel cell stacks
PublicationThis paper presents an innovative, electrochemical impedance method for monitoring of electrochemical behaviour of a multi-cell, direct methanol fuel cell (DMFC) device. This method not only provides classical voltage changes at successive cells but also allows their detailed impedance behaviour to be presented. Impedance characteristics of individual cells within a fuel cell stack (depending on actual operating conditions) are...
-
Miniaturized impedance analyzer using AD5933
PublicationThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Miniaturized impedance analyzer using AD5933
PublicationThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
PublicationUsability of Electrochemical Impedance Spectroscopy data for better cathodic protection control was investigated. Carbon steel – S235JR2 grade specimen were exposed in artificial seawater environment. Samples were polarized and their potentials corresponded to four different cathodic protection degrees. Time evolution of Electrochemical Impedance spectra was investigated. Goodness of fit function (X2) was analysed in terms of proper...
-
Application of dynamic impedance spectroscopy to scanning probe microscopy.
PublicationDynamic impedance spectroscopy, designed for measuring nonstationary systems, was used in combination with scanning probe microscopy. Using this approach, impedance mapping could be carried-out simultaneously with topography scanning. Therefore, correlation of electrical properties with particular phases of an examined sample was possible. The sample used in this study was spheroidal graphite cast iron with clearly defined phases...
-
Electrochemical Evaluation of Sustainable Corrosion Inhibitors via Dynamic Electrochemical Impedance Spectroscopy
PublicationFinding suitable measurement methods for the effective management of electrochemical problems is of paramount importance, particularly for improving efficiency in corrosion protection. The need for accurate measurement techniques specific to nonstationary conditions has long been recognized, and promising approaches have emerged. This chapter introduces dynamic electrochemical impedance spectroscopy as a novel advancement in electrochemistry...
-
Effective length of lightning protection earthings
PublicationSystem uziemień współczesnych obiektów jest zwykle bardzo rozległy, a na łączenie poszczególnych elementów uziemiających za pomocą głównej szyny wyrównania potencjałów uwzględnia także uziemienia stacji transformatorowej. Ocena przydatności takiego systemu uziemień do celów ochrony odgromowej nie jest prosta, bo tylko jego część określana, jako długość efektywna bierze udział w odprowadzaniu do gruntu prądu piorunowego. Praca zawiera...
-
Validity of impedance spectra obtained by dynamic electrochemical impedance spectroscopy verified by Kramers-Kronig transformation.
PublicationArtykuł przedstawia weryfikację wiarygodności widm impedancyjnych otrzymanych za pomocą niedawno wprowadzonej techniki eksperymentalnej - Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej (Dynamic Electrochemical Impedance Spectroscopy, DEIS). Technika ta zakłada, że badany system jest pseudostacjonarny jeśli czas pomiaru jest odpowiednio krótki. Czas potrzebny na otrzymanie pojedynczego spektrum zależy od długości okna...
-
A complete impedance analysis of electrochemical cells used as energy sources
PublicationA comprehensive description of impedance ofelectrochemical systems has been presented, along withthe assumptions of the method used. In this method, amultisinusoidal current excitation signal is used. Thechanges of potential of both the electrodes and thepotential difference between these electrodes are allregistered simultaneously as a function of time. Theproposed method offers the possibility of separatelydetermining the instantaneous...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublicationThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Assessment of organic coating degradation via local impedance imaging
PublicationThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...
-
Finding the protection of lighting grounding with estimating its impulse impedance componets
PublicationOmówiono metodę rozdzielania składowych impedancji udarowej uziemień. Podano wskazania dotyczące oceny jakości ochrony odgromowej na podstawie wartości składowych impedancji udarowej.
-
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Local electrochemical impedance spectroscopy in dynamic mode of galvanic coupling
PublicationA novel method that combines local electrochemical impedance spectroscopy and mapping in dynamicmode is proposed. Method was validated over two galvanic couplings, namely zinc/copper and cad-mium/copper. Impedance spectrum response for all measuring points was obtained by means ofsimultaneous implementation of selected range of frequencies. Proposed method allows the measure-ment in a more time-efficient manner, at the same time...
-
Fast High-Impedance Spectroscopy Method Using SINC Signal Excitation
PublicationIn this paper the method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 Gohm) is evaluated by means of simulation and practical experiment. The method is based on excitation of an object with a sinc signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance spectrum is obtained with use of continuous Fourier transform...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublicationIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Scalable Measurement System for Multiple Impedance Gas Sensors
PublicationAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...
-
Validation of dynamic electrochemical impedance spectrograms using autocorrelation function
PublicationValidation of impedance data is essential for checking the reliability of experimental data. Kramers – Kronig transformation is used to verify data obtained from classical Electrochemical Impedance Spectroscopy (EIS) measurements. Data obtained from Dynamic Electrochemical Impedance Spectroscopy (DEIS) could be validated in the same way, but in this case, there is no information about internal consistency between every single spectrum...
-
Novel application of dynamic electrochemical impedance monitoring to a cataphoretic coating process
PublicationThe paper presents a novel method of on-line impedance monitoring of cataphoretic coating application process. Utilization of dynamic electrochemical impedance spectroscopy (DEIS) overcame the fundamental problem connected with non-stationarity of the aforementioned coating deposition process, which eliminates classical impedance spectroscopy technique from a real-time description of cataphoresis. The paper illustrates selected examples...
-
Monitoring of CRT by means of impedance multiple measurements - simulation studies
PublicationCardiac resynchronization therapy (CRT) is a very promising treatment for patients with congestive heart failure. An Impedance Cardiography (ICG) is used for evaluation of heart mechanical activity. A simulation study with the use of a FEM model was performed. The developed realistic model of the thorax, based on CT data obtained from examination of a 68-year-old man, consisted of 212 000 tetrahedral elements. Different configurations...
-
Analysis of thoracic regional impedance changes using PCA approach
PublicationA multichannel impedance and one lead electrocardiographic recording system has been developed. The impedance measurement unit is built using a four-electrode technique. It consists of a sinusoidal, 40 kHz, current source and five measurement channels. Circumferential current electrodes have been located at a neck and an abdomen. Voltagemeasurement disk electrodes formed five two-electrode measurement ports. The impedance change...
-
IMPEDANCE MEASUREMENT MODULE FOR GAS SENSORS WITH TEMPERATURE CONDITIONING FEATURE
PublicationThe paper presents an impedance measurement module which is aimed for gas sensor. Sensor’s heater temperature conditioning and modulation feature is available in order to allow implementation of different techniques improving selectivity and sensitivity of gas sensors. The measurement module uses three-parameter sine-fitting technique for impedance measurement. To monitor sensor temperature, the resistance of the sensor’s heater...
-
Evaluation of Lightning Protection Earthings by Impulse Tests
PublicationW artykule zamieszczono opis nowej procedury pomiaru uziemień odgromowych metodą udarową. Zgodnie z propozycję podczas testu udarowego można pomierzyć nie tylko impedancję udarową uziemienia, ale także ocenić jego rezystancję oraz współczynnik udaru. Wynik takiego badania uwzględnia tylko tę część uziomu, którą określa się jako jego długość efektywną.
-
Application of different modes of nanoscale impedance microscopy in materials research
PublicationIn recent years, there is noticeable interest in application of various types of scanning probe microscopy in material science research. One of them is contact atomic force microscopy combined with local impedance measurements, known as nanoscale impedance microscopy. Literature references present its application in investigations of new materials, microelectronics diagnostics, or research of protective coatings performance. In...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
PublicationLocal impedance imaging (LII) was used to visualise surficial deviations of AC impedances in polycrystalline boron-doped diamond (BDD). The BDD thin film electrodes were deposited onto the highly doped silicon substrates via microwave plasma-enhanced CVD. The studied boron dopant concentrations, controlled by the [B]/[C] ratio in plasma, ranged from 1 × 1016 to 2 × 1021 atoms cm−3. The BDD films displayed microcrystalline structure,...
-
Impedance of cation-coupled electron transfer reaction: Theoretical description of one pathway process
PublicationIt has been assumed that cation electron coupled charge transfer can be conducted in accordance with two mutually coupled reactions. Using a differential method an expression was introduced which describes the impedance of a cation electron coupled transfer reaction. Also, an electrical equivalent circuit has been defined. The total faradaic impedance is the sum of electron transfer impedance and cation transfer impedance. Issues...
-
Application of Impedance Spectroscopy for Bi1−xNdxFeO3 Ceramics Characterization
PublicationIn the present paper the synthesis conditions for fabrication of Bi1−xNdxFeO3 ceramics are reported. The single phase polycrystalline samples of Bi1−xNdxFeO3 were prepared by standard solid state reaction method from the mixture of oxides viz.: Bi2O3, Fe2O3 and Nd2O3. The samples were characterized by impedance spectroscopy in the frequency range 10Hz – 1MHz at room temperature.
-
Nonlinear impedance in oxide glasses containing single and mixed alkali ions
PublicationThe aim of the present was to find more clues on the nonlinearities in impedance of oxide glasses. The first family of researched glasses has a composition of FeO-P2O5-Na2O. Oxide glasses containing iron and alkali are well known for a very low alkali ion mobility and may be considered purely polaron conducting. These glasses show no detectable nonlinearities in the impedance spectra. The second was a family of ionic conducting...
-
An Application Supporting Gastroesophageal Multichannel Intraluminal Impedance-pH Analysis
PublicationDue to a significant rise in the number of patients diagnosed with diseases of the upper gastrointestinal tract and the high cost of treatment, there is a need to further research on one of the most popular diagnostic tests used in this case – esophageal Multichannel Intraluminal Impedance and pH measurement. This may lead to finding new diagnostically relevant information, used to quicken and improve the diagnostic procedure....
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Efficient Analysis of Noise Induced in Low-Voltage Installations Placed Inside Buildings with Lightning Protection Systems
PublicationThis paper describes an efficient approach to the broadband analysis of lightning protection systems (LPSs) using the method of moments (MoM) implemented in the frequency domain. The adaptive frequency sampling (AFS) algorithm, based on a rational interpolation of the relevant observable (e.g., voltage, current, electric or magnetic field) which describes the properties of the LPS, is employed to reduce the number of samples computed...
-
The high impedance measuring probe for gain-phase analysers.
PublicationAutorzy opracowali tanią sondę pomiarową przeznaczoną do pracy z analizatorami gain-phase jak Solartron 1260 Impedance/Gain-phase Analyser, 1255 Frequency Response Analyser (FRA) lub starszymi wersjami 1250, 1253. Przedstawiona architektura sondy wyznacza jej parametry metrologiczne. Pomiary możliwe są w 8 zakresach obejmujących wartości 100ohm<|Zx|<100Gohm w szerokim zakresie częstotliwości 10uHz-1MHz. Obwód wejściowy sondy pozwala...
-
Application of quartz crystal microbalance and dynamic impedance spectroscopy to the study of copper corrosion inhibitors
PublicationThe study investigates the application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) and Electrochemical Quartz Crystal Microbalance (EQCM) techniques to examine the corrosion inhibition of copper by Benzotriazole and Sodium Folate in a 0.1 M NaCl solution. DEIS, an advanced version of Electrochemical Impedance Spectroscopy (EIS), allows for real-time monitoring of non-stationary electrochemical systems,...
-
The Influence of Thin Gold Electrodes on the High-Temperature Impedance of Oxide Glasses
PublicationThe influence of thin gold electrodes on the electrical measurements of glasses at high temperatures was studied using impedance spectroscopy. The impedance was measured several times over a wide frequency range from 10 mHz to 1 MHz and the temperature ranged from 213 to 673 K under air and nitrogen atmospheres. The results showed a drop in the conductivity of more than an order of magnitude at a temperature around 603 K during...
-
Applicability of an effective conductivity approach in modeling thoracic impedance changes
PublicationThis paper describes numerical simulations of the influence of conductivity changes inside a volume conductor on impedance changes measured on its surface. A simple model based on the finite element method has been developed to estimate an applicability of the effective conductivity theory in human chest modeling. The model consisted of a cylinder with two concentric spheres inside. Simulations were performed for two cases: first...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublicationThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Multi-objective design of miniaturized impedance transformers by domain segmentation
PublicationFast multi-objective design optimization of compact microstrip impedance transformers is discussed. Our approach exploits approximation models constructed using sampled coarse- mesh EM simulation data in a partitioned design space and response correction techniques for design refinement. Demonstra
-
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublicationIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...