Search results for: PH-SENSITIVITY
-
Improvement of derivatized amino acid detection sensitivity in micellar electrokinetic capillary chromatography by means of acid-induced pH-mediated stacking technique
PublicationDerivatization is a frequently used sample prepara-tion procedure applicable to the enhancement of analyte de-tection sensitivity. Amino acids mostly require derivatization prior to electrophoretic or chromatographic analysis, especial-ly if spectrophotometric detection is used. This study presents an on-line preconcentration technique for derivatized amino acids. The sensitivity of the method was improved by the utilization of...
-
Supporting Gastroesophageal Reflux Disease Diagnostics by Using Wavelet Analysis in Esophageal pH-Metry
PublicationThis paper presents a new approach to computer supported esophageal pH-metry measurement analysis performed in order to diagnose gastroesophageal reflux disease. In this approach wavelet analysis was used to analyse the esophageal pH-metry course. The research was performed on three groups of pH-metry courses: whole 24-hour pH-metry course, sleep only pH-metry course and 20 minutes after the end of a meal pH-metry course. After...
-
Myrosinase activity in different plant samples; optimisation of measurement conditions for spectrophotometric and pH-stat methods
PublicationMyrosinase found in Brassicaceae plants, is the enzyme responsible for hydrolysis of glucosinolates. As a result a variety of biologically active metabolites are liberated, whose importance in crop protection and especially in cancer chemoprevention is rapidly gaining recognition. The growing practical application of glucosinolate degradation products requires that sensitive and reliable methods of myrosinase activity determination...
-
Effect of pH on optical sensing with poly-L-lysine-modified nanodiamonds
PublicationNitrogen-vacancy (NV) centers are crystallographic defects which provide diamonds with unique physical properties. The centers are known for their intensive, time-stable fluorescence, and an electron spin, which exhibits long coherence time and may be manipulated using external stimuli. Nanodiamonds containing the NV centers are promising tools in biolabeling, biosensing, and drug delivery due to the aforementioned properties of...
-
Poly-L-Lysine-functionalized fluorescent diamond particles: pH triggered fluorescence enhancement via surface charge modulation
PublicationRecently, the interest in applying fluorescent diamond particles (FDPs) containing nitrogen-vacancy (NV) centers for enhancing the mechanical and chemical properties of some materials, biological imaging, and sensing has been expanding rapidly. The unique properties of NV centers such as intensive, time-stable fluorescence, and an electron spin, which exhibits long coherence time and may be manipulated using external stimuli, such...
-
Application of Wavelet Transform and Fractal Analysis for Esophageal pH-Metry to Determine a New Method to Diagnose Gastroesophageal Reflux Disease
PublicationIn this paper, a new method for analysing gastroesophageal reflux disease (GERD) is shown. This novel method uses wavelet transform (WT) and wavelet-based fractal analysis (WBFA) on esophageal pH-metry measurements. The esophageal pH-metry is an important diagnostic tool supporting the physician’s work in diagnosing some forms of reflux diseases. Interpreting the results of 24-h pH-metry monitoring is time-consuming, and the conclusions...
-
Release of selected chemical elements from shale drill cuttings to aqueous solutions of different pH
PublicationThe effect of pH changes on leachability of light and heavy metals from shale drill cuttings generated from unconventional shale gas production was investigated. Cuttings, being the primary byproduct generated from drilling operations, belong to the potentially hazardous type of wastes due to presence of heavy and radioactive elements and remains of drilling fluid. In this regard, assessment of potentially dangerous components...
-
Measurement of sub-nanometer molecular layers with ISFET without a reference electrode dependency
PublicationA new method of detection and measurement with sub-nanometer resolution of layers adsorbed or bonded to the ISFET's gate dielectric was presented. The sensitivity of this method is high enough to detect even partial mono-layer covering. The transconductance measurement of the ISFET provides independence of the output signal from pH changes and the driving electrode electrochemical potential instabilities. The stable reference electrode...
-
Stable and degradable microgels linked with cystine for storing and environmentally triggered release of drugs
PublicationEnvironmentally sensitive, degradable microgels based on poly(N-isopropylacrylamide) (pNIPA) crosslinked with the diacryloyl derivative of cystine (BISS) were synthesized by applying surfactant-free emulsion polymerization. pNIPA contributed the sensitivity to temperature to the microgels and the cross-linker made them degradable and sensitive to pH. The morphology of the microgels was investigated by using scanning and transmission...
-
Electrophoretic Deposition and Characterization of Chitosan/Eudragit E 100 Coatings on Titanium Substrate
PublicationCurrently, a significant problem is the production of coatings for titanium implants, which will be characterized by mechanical properties comparable to those of a human bone, high corrosion resistance, and low degradation rate in the body fluids. This paper aims to describe the properties of novel chitosan/Eudragit E 100 (chit/EE100) coatings deposited on titanium grade 2 substrate by the electrophoretic technique (EPD). The deposition...
-
Electrophoretic Deposition of Chitosan/Eudragit E 100/AgNPs Coatings for Controlled Release of Antibacterial Substance
PublicationThe development of bacterial infection of the tissues surrounding an implant is one of the leading causes of implant surgery failure. In order to prevent the deposition of bacteria on the implant surface and the formation of biofilm, coatings that exhibit antibacterial properties are manufactured. However, the problem is the controlled release of the therapeutic substance from the coating over the extended life of the implant [1],...
-
Ultrasound-assisted deep eutectic solvent-based liquid–liquid microextraction for simultaneous determination of Ni (II) and Zn (II) in food samples
PublicationA new approach was developed for the simultaneous pre-concentration and determination of Ni (II) and Zn (II) in food samples. This method is based on ultrasound-assisted liquid–liquid micro extraction using hydrophobic deep eutectic solvent (DES) and 1,10-phenanthroline as chelating agent. The effect of several parameters, such as pH, selection and volume of DES, amount of chelating agent, time of sonication and centrifugation,...
-
Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction Using Deep Eutectic Solvents (DESs) for Neutral Red Dye Spectrophotometric Determination
PublicationDeep eutectic solvents (DES), which have low toxicity and are low cost, biodegradable, and easily synthesized, were used for the extraction of neutral red (NR) dye before its spectrophotometric analysis. DES, containing choline chloride as a hydrogen bond acceptor and phenol as a hydrogen bond donor with a molar ratio of 1:2, was used for the extraction of NR dye from aqueous media. The possible interaction of different DESs with...
-
N-doped carbon nanospheres as selective fluorescent probes for mercury detection in contaminated aqueous media: chemistry, fluorescence probing, cell line patterning, and liver tissue interaction
PublicationA precise nano-scale biosensor was developed here to detect Hg2+ in aqueous media. Nitrogen-doped carbon nanospheres (NCS) created from the pyrolysis of melamine–formaldehyde resin were characterized by FESEM, XRD, Raman spectra, EDS, PL, UV–vis spectra, and N2 adsorption–desorption, and were used as a highly selective and sensitive probe for detecting Hg2+ in aqueous media. The sensitivity of NCS to Hg2+ was evaluated by photoluminescence...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
The electrochemical determination of isatin at nanocrystalline boron-doped diamond electrodes: stress monitoring of animals
PublicationUltra-thin nanocrystalline boron-doped diamond electrodes (B:NCD) were used for the electrochemical determination of isatin in dog urine samples using cyclic voltammetry and square wave voltammetry in a phosphate buffer saline, pH = 7.2. No additional modification or pretreatment of the electrode surface was required in this approach, being of high importance for the facile detection procedure. The increase of the peak current...
-
Direct determination of paraquat herbicide by square-wave voltammetry by two-step transfer mechanism at heterogeneous boron-doped carbon nanowall electrodes
PublicationBoron-doped carbon nanowalls (B:CNW) versus boron-doped diamond (BDD) materials were investigated for the effective electrochemical detection of highly toxic herbicide paraquat (PQ). Depending on the surface morphology and functional groups of BDD and B:CNWs, the electrochemical absorption and detection of the target analyte PQ revealed different detection mechanisms. The surface absorption mechanism was mainly observed for BDD,...
-
An electrochemical biosensor for the determination of hormone Human Chorionic Gonadotropin (hCG) in human serum
PublicationThis work describes the modification of a gold electrode to create an electrochemical biosensor capable of detecting human chorionic gonadotropin (hCG). The biosensor was obtained by modifying the gold electrode with cysteamine and oligopeptide (PPLRINRHILTR). The modification steps of the gold electrode were confirmed by cyclic voltammetry (CV) and impedance electrochemical spectroscopy (EIS) measurements. The conducted EIS experiments...
-
Impact of Cultivation Conditions, Ethylene Treatment, and Postharvest Storage on Selected Quality and Bioactivity Parameters of Kiwifruit “Hayward” Evaluated by Analytical and Chemometric Methods
PublicationOrganic, semiorganic, and conventional “Hayward” kiwifruits, treated with ethylene for 24 h and stored during 10 days, were assessed by UV spectrometry, fluorometry, and chemometrical analysis for changes in selected characteristics of quality (firmness, dry matter and soluble solid contents, pH, and acidity) and bioactivity (concentration of polyphenols via Folin-Ciocalteu and p-hydroxybenzoic acid assays). All of the monitored...
-
Właściwości i potencjalne zastosowania azobenzokoron: hydroksyazobenzokorony
PublicationW rozprawie doktorskiej przedstawiono właściwości oraz metody syntezy azobenzokoron oraz hydroksyazobenzokoron. Opisano również zastosowanie związków makrocyklicznych jako chromojonoforów w czujnikach optycznych. W ramach pracy zbadano wpływ pH, rozpuszczalników oraz obecności jonów na równowagę tautomeryczną wybranych hydroksyazobenzokoron. Zbadano również równowagę kompleksowania jonów metali przez te związki oraz sprawdzono...
-
Progress in targeting tumor cells by using drug-magnetic nanoparticles conjugate.
PublicationTo limit the cytotoxicity of anticancer drugs against healthy cells, an appropriate carrier should be synthesized to deliver the drug to the tumor tissue only. A good solution is to anchor a magnetic nanoparticle to the molecule of the drug and to use a properly directed external magnetic field. We have shown that the improved by us synthesis of the conjugate of doxorubicin with iron-oxide magnetic nanoparticles allows a substantial...
-
Ranking of ecotoxisity tests for underground water assessment using the Hasse diagram technique
PublicationThe present study deals with the novel application of the Hasse diagram technique (HDT) for the specific ranking of ecotoxicity tests capable of assessment of underground water quality. The area studied is a multi-municipal landfill in the northern Poland. The monitoring network of the landfill constitutes of 27 piezometers for underground water monitoring and two observation points at surface water courses. After sampling, chemical...
-
Green porous benzamide-like nanomembranes for hazardous cations detection, separation, and concentration adjustment
PublicationGreen biomaterials play a crucial role in the diagnosis and treatment of diseases as well as health-related problem-solving. Typically, biocompatibility, biodegradability, and mechanical strength are requirements centered on biomaterial engineering. However, in-hospital therapeutics require an elaborated synthesis of hybrid and complex nanomaterials capable of mimicking cellular behavior. Accumulation of hazardous cations like...
-
Effects of biotransport and hydro-meteorological conditions on transport of trace elements in the Scott River (Bellsund, Spitsbergen)
PublicationThe shaping of surface water chemistry in the Svalbard Archipelago is strongly dependent on the geology of the catchment and the process of long-range transport of atmospheric pollutants (LRATP). It was found that the dissolved trace elements in the Scott River, which catchment is characterized by a decreasing degree of glaciation, were of the natural origin (i.a. weathering and dissolution of local geological substratum). The...
-
Monosubstituted hydrazone β-cyclodextrin derivatives for pH-sensitive complex formation with aromatic drugs
PublicationA new and convenient synthetic pathway was developed to produce monosubstituted cyclodextrins with high yields. Each of the β-cyclodextrin derivatives described in this work has an aromatic substituent connected with cyclodextrin core by a pH-sensitive hydrazone linker and a carbon chain. Carbon chains differ in lengths having one or three carbon atoms. The correlation between water solubility and linker length was determined using...