displaying 1000 best results Help
Search results for: THERMOGRAPHY, TESTING, VARISTORS
-
Application of Infrared Thermography to Non-Contact Testing of Varistors
Publication -
Diagnostics of zno varistors by means of nondestructive testing
PublicationStandard industrial testing of high-voltage varistors for surge arresters demands application of high voltages and intensive currents. Nondestructive methods for varistor quality and endurance evaluation have been proposed and described. They rely on the application of resonant ultrasound spectroscopy, electro-ultrasonic spectroscopy, noise measurement and nonlinearity testing at voltages lower than continuous operating range....
-
Application of infrared thermoography to non-contact testing of varistors
PublicationTesting of varistors using thermography was carried out in order to assess their protective properties against possible overvoltage phenomena in the form of high-level voltage surges. An advantage of the thermography technique is non-contact temperature measurement. It was proposed to assess the properties of varistors workingin electronic devices as protective elements, on the basis of estimating temperature increments on varist...
-
APPLICATION OF INFRARED THERMOGRAPHY TO NON-CONTACT TESTING OF AD/DC POWER SUPPLY
PublicationTesting of AC/DC power supplies using the thermography was carried out in order to assess their assembly and operation correctness before launching them on the market. The investigation was carried out for 17 AC/DC power supplies which passed the standard tests (measurements of their basic parameters and characteristics). The investigation consisted of two steps. In the first step the dispersion of temperature on power supply boards...
-
Classification of high-voltage varistors into groups of differentiated quality
PublicationThe research was aimed on defining a factor of quality for high-voltage varistors using Non-Destructive Testing (NDT) techniques, which could be applied during the production testing. The newly proposed parameter Q determined on the basis of the lowest resonant frequency fr measured within the preselected frequency range was taken into account. The parameter Q was defined for ZnO structures after firing, without metallized contacts....
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublicationThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
Quality assessment of ZnO-based varistors by 1/f noise
PublicationNoise has been used as a diagnostic tool of surge arrester varistor structures comprising of ZnO grains of various type and size. The physical and electrical properties of the measured samples have been described. In the experimental study, the applied measurement system and the results of noise measurements for the selected structures of varistors designed for the continuous working voltage 280 V, 440 V and 660 V have been presented....
-
Resonant ultrasonic spectroscopy in high-voltage varistor spectroscopy
PublicationResonant spectroscopy is an effective non-destructive testing method focused on defects in tested objects. The testing procedure, based on the resonant pattern, allows rejection of the tested samples with defects which do not fit the pattern. A sweeping frequency method has been used to measure the spectrum of resonances in high-voltage varistors. As a result we can observe resonances that depend directly on inhomogeneity of the...
-
A universal NDT method for examination of low energy impact damage in CFRP with the use of TLC film
PublicationThe article presents an attempt to use a sheet of laminated thermochromic liquid crystal film (TLC film) for non-destructive testing of the impact damage (energy values: 1J, 2J, 3J and 4J) in carbon fibre-reinforced polymer (CFRP). This is a new, alternative NDT approach based on the thermo-optical effect. The main advantages of this method are a) the low cost of TLC film, b) the low cost of recording devices due to the usage of...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublicationResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
Face detection in image sequences using a portable thermal camera
PublicationFace detection is often a first step in quantitative analysis of face images. It is an important research area for visible images and recently also for thermography. Due to technological developments thermal cameras may be embedded into wearable devices to provide remote healthcare. In this paper, we compared three algorithms for face detection in thermal images by testing execution time, accuracy, symmetry ratio and false-positives....
-
Active IR-Thermal Imaging in Medicine
PublicationIn this paper we summarize results of several research projects devoted to development of new diagnostic methods and procedures based on quantitative infrared thermography in medical applications. First, basics of active dynamic thermography are presented. Described are both, instrumentation and software comprising measurement procedures including collection of series of IR-images after external excitation, data treatment with...
-
ADT in mammography
PublicationWe discuss limitations of the known methods of IR imaging in diagnostics of breast cancer. In conclusion we show that for practical reasons one requires new approaches because the known methods based on simple observation of external temperature distribution are not fully effective. Even advanced pattern recognition could not help too much for static images. We ask the question: may active dynamic thermography, known in nondestructive...
-
POLYMER TESTING
Journals -
Mariusz Kaczmarek dr hab. inż.
PeopleReceived M.Sc., Eng. in Electronics in 1995 from Gdansk University of Technology, Ph.D. in Medical Electronics in 2003 and habilitation in Biocybernetics and Biomedical Engineering in 2017. He was an investigator in about 13 projects receiving a number of awards, including four best papers, practical innovations (7 medals and awards) and also the Andronicos G. Kantsios Award and Siemens Award. Main research activities: the issues...
-
Quality assessment of high voltage varistors by third harmonic index
PublicationHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
Problems of Active Dynamic Thermography Measurement Standardization in Medicine
PublicationReliability of thermographic diagnostics in medicine is an important practical problem. In the field of static thermography, a great deal of effort has been made to define the conditions for thermographic measurements, which is now the golden standard for such research. In recent years, there are more and more reports on dynamic tests with external stimulation, such as Active Dynamic Thermography, Thermographic Signal Reconstruction...
-
Magnetic and infrared thermography methods in detection of antipersonnel landmines
PublicationIn this paper the two alternative methods of antipersonnel landmine detection are shown: the magnetic method and the active infrared thermography. The experimental results of the detection of selected, plastic mines using both methods are also presented.
-
Active Dynamic Thermography in Medical Diagnostics
PublicationThis is an overview of active thermal imaging methods in medical diagnostics using external thermal stimulation. In this chapter, several clinical cases diagnosed using the active dynamic thermography method, ADT, are presented. Features of this technology are discussed and main advantages underlined. Applications in skin burn diagnostics and quantitative evaluation leading to modern classification of burned patients for further...
-
FFT spectrum based matching algorithm for activedynamic thermography
PublicationIn Active Dynamic thermography (ADT) sequences of consecutive temperature distributions are analyzed. In biomedical applications of ADT, the problems of a patient's movements in front of a thermal camera should be eliminated before data analysis. Complete mechanical stabilization of the patients is impossible due to natural voluntary and involuntary moves caused by pulse breathing, etc. This paper presents a simple and efficient...
-
Impact resistance of plain and twill fabric in GFRP measured by active thermography
PublicationThis paper discusses the impact resistance of glass-fibre reinforced polymer (GFRP) composites depending on the type of reinforcement – plain or twill weave. The values of impact energy were: 3J, 10J and 15J. Specimens featuring twill weave transferred higher force during the impact as compared with plain weave specimens. It was observed that an increase of impact energy was accompanied by an increase of the disproportion in...
-
Diagnostics of high-voltage varistors by acoustic emission
PublicationWarystory, szeroko stosowane w ogranicznikach przepięć, powinny być testowane na końcowym etapie ich wytwarzania. Stosowane metody testowania wymagają użycia wysokich napięć i prądów o dużych natężeniach, co jest nidogodne, destrukcyjne i wymaga poboru relatywnie dużych pocy. W artykule zaproponowano zastosowanie analizy sygnału emisji akustycznej do predykcji jakości struktury warystora. Opisano system przygotowany do tej aplikacji,...
-
Active dynamic thermography method for TRAM flap blood perfusion mapping in breast reconstruction
PublicationThis paper presents the new method of the transverse rectus abdominis musculocutaneous flap blood perfusion mapping based on the active dynamic thermography. The method is aimed at aiding a surgeon during breast reconstruction procedure. A pair of dTnorm and t90_10 parameters were used as parametric image descriptors of the flap blood perfusion. The method was tested on 38 patients that were subjected to breast reconstruction procedure....
-
The use of the static thermography in monitoring flap perfusion in breast reconstruction with TRAM flap
PublicationThis paper shows results of the static thermography for intraoperative and postoperative imaging of TRAM flap perfusion. The results were compared with the clinical examination of flap perfusion. The study was conducted on a group of 38 female patients who underwent breast reconstruction.
-
Active Dynamic Thermography imaging of wound healing processes in cardio surgery
PublicationThe surgery is a branch of medicine, that is integrally connected to wounds. Despite using sterile tools and compliance with aseptic rolls, some of the surgery wounds become infected. In clinical practice there is a lack of cheap, objective methods and tools for quantitative definition and estimation of the surgery wound healing progress. This paper presents preliminary results of Active Dynamic Thermography (ADT) parametric imaging...
-
The Use of Liquid Crystal Thermography an Image Processing in Heat and Fluid-Flow Research
PublicationLiquid crystal thermography (LCT) have been used in many technical, industrial and biomedical applications [1]. During over 20 years it has been successfully applied in Department of Energy and Industrial Apparatus at Gdansk University of Technology for visualization of steady-state and transient temperature fields. In order to demonstrate feasibility of LCT techniques in practical heat transfer contexts, the authors have performed...
-
Graph security testing
PublicationSet S ⊂ V is called secure set iff ∀ X ⊂ S | N [ X ] ∩ S | ≥ | N ( X ) \ S | [3]. That means that every subset of a secure set has at least as many friends (neighbour vertices in S) as enemies (neighbour vertices outside S) and will be defended in case of attack. Problem of determining if given set is secure is co −NP -complete, there is no efficient algorithm solving it [3]. Property testers are algorithms that distinguish inputs...
-
Active dynamic thermography in cardiosurgery
Publication.
-
Active dynamic thermography in mammography.
PublicationW artykule przedstawiono zaproponowany numeryczny model termiczny piersi z nowotworem umiejscowionym na różnych głębokościach. Przedstawione są wyniki symulacji modelu dla różnych warunków zewnętrznego pobudzenia termicznego powierzchni piersi. Pokazano również wyniki przykładowego badania termograficznego piersi z nowotworem.
-
Dynamic thermography in diagnostics of onychomycosis.
PublicationW pracy zaprezentowano wyniki badań grzybicy paznokci przy użyciu termografii dynamicznej. Przedstawione wyniki badań pokazują, że metoda ta może okazać się skuteczna przy określaniu stanu mikrokrążenia w tkance pod paznokciem, co pozwoliłoby określić stopień zaawansowania choroby grzybiczej, a więc także umożliwiałoby ocenę postępów leczenia tej przypadłości.
-
Physical testing methods of materials
e-Learning Courses -
The Use of Liquid Crystal Thermography in Selected Technical and Medical Applications—Recent Development
PublicationThermochromic liquid crystals (TLC) and true-colour digital image processing have been successfully used in non-intrusive technical, industrial and biomedical studies and applications. Thin coatings of TLC at surfaces are utilized to obtain detailed temperature distributions and heat transfer rates for steady or transient processes. Liquid crystals also can be used to make the temperature and velocity fields in liquids visible...
-
Mechanical testing of technical woven fabrics
PublicationThis article presents a review of technical fabrics testing methods used by the authors on the basis of their experience with research on properties of polytetrefluoroethylene-coated fabrics used for Forest Opera in Sopot (Poland). First, the different types of testing methods used for description of mechanical properties (uniaxial tensile tests, biaxial tensile tests and shear tests) of technical woven fabrics are described. The...
-
Liquid crystal thermography experimental application
PublicationPraca przedstawia wykorzystanie termografii ciekłokrystalicznej do badania zjawisk wymiany ciepła z zastosowaniem metod stanu ustalonego i przejściowej.
-
Special Issue: “Non-Destructive Testing of Structures”
PublicationThe Special Issue “Non-Destructive Testing of Structures” has been proposed to present recent developments in the field of diagnostics of structural materials and components in civil and mechanical engineering. The papers highlighted in this editorial concern various aspects of non-invasive diagnostics, including such topics as condition assessments of civil and mechanical structures and connections of structural elements, the...
-
GENETIC TESTING
Journals -
Well Testing
Journals -
Language Testing
Journals -
The use of liquid crystal thermography TLC and particle image velocimetry PIV in selected technical applications
PublicationNowadays, the energy cost is very high and this problem is carried out to seek techniques for improvement of the aerothermal and thermal (heat flow) systems performances in different technical applications. The transient and steady-state techniques with liquid crystals for the surface temperature and heat transfer coefficient or Nusselt number distribution measurements have been developed. The flow pattern produced by transverse...
-
Physical testing methods of materials 23
e-Learning Courses -
Combined environmental testing device for picosatellites
PublicationAs access to space conditions becomes more available, both technically and economically, scientists’ interest in launching finer and more sophisticated experiments grows. To be qualified for launch, such experiments need to be carefully tested prior to the event. The tests should represent actual launch conditions as closely and in a detailed manner. Typical tests for payload include: vibration tests, thermal and vacuum tests,...
-
Non-destructive Testing of Wooden Elements
PublicationExamining the condition of wooden elements is crucial from the perspective of proper structure performance. If the deterioration in the internal wood condition, which displays no symptoms visible from the outside, is detected, the further spread of the deterioration can be prevented. Test results often point to the necessity of conducting repairs and, renovations, replacing the structure of wooden beams, or even substituting a...
-
Data processing methods for dynamic medical thermography.
PublicationArtykuł przedstawia zastosowanie nowej metody syntezy obrazów w termografii dla potrzeb opisu ilościowego właściwości termicznych tkanek. Opis taki umożliwia różnicowanie przypadków medycznych. Metodę zastosowania dla licznych pomiarów fantomowych i in vitro w eksperymentach na zwierzętach (świnia domowa). Przedstawiono i omówiono rezultaty prac.
-
Synthesis of parametric images in the medical active thermography
PublicationArtykuł przedstawia zastosowanie nowej metody syntezy obrazów w termografii dla potrzeb opisu ilościowego właściwości termicznych tkanek. opis taki umożliwia różnicowanie przypadków medycznych. Metodę zastosowania dla licznych pomiarów fantomowych oraz in vitro. Przedstawiono i omówiono rezultaty prac.
-
Liquid crystals thermography for technical and biomedical application
PublicationW artykule opisano termografię ciekłokrystaliczną jako technikę wykorzystu-jącą termochromatyczne ciekłe kryształy do badań technicznych i biomedycz-nych. W szczególności dotyczy to badań wymiany ciepła i masy, chorób skór-nych i podobnych. Praca zawiera ilustracje z badań przeprowadzonych przezautorów.
-
The influence of carbon dioxide on dynamic thermography results
Publication -
Implementation of Active Dynamic Thermography in medical diagnostics
PublicationW pracy przedstawiono wyniki badań wdrożeniowych Aktywnej Termografii Dynamicznej w diagnostyce wybranych chorób.
-
Usability Testing of Mobile Applications: A Methodological Framework
PublicationLess than five percent of all mobile applications have become successful throughout 2023. The success of a new mobile application depends on a variety of factors ranging from business understanding, customer value, and perceived quality of use. In this sense, the topic of usability testing of mobile applications is relevant from the point of view of user satisfaction and acceptance. However, the current knowledge seems to be fragmented,...
-
Testing for conformance of parallel programming pattern languages
PublicationThis paper reports on the project being run by TUG and IMAG, aimed at reducing the volume of tests required to exercise parallel programming language compilers and libraries. The idea is to use the ISO STEP standard scheme for conformance testing of software products. A detailed example illustrating the ongoing work is presented.
-
Selected Problems of Experimental Testing Marine Stern Tube Bearings
PublicationThis paper presents typical methods for conducting experimental tests on main shaft slide bearings. There are described their possible testing capabilities, advantages, drawbacks and limitations. Various testing methods were analyzed to find a solution able of providing a wide range of possible investigations at possibly acceptable limitations.