Search results for: doppler
-
Doppler effect in the CW FM sonar
PublicationWhen sonars are used for military purposes they have to ensure unobtrusive operation, a feature that can be potentially secured by 'silent sonar' or continuous wave frequency modulation sonars (CW FM sonars). The article presents how these sonars operate and identifies the relations between their parameters. The Doppler effect and its impact on the CW FM sonar are studied to identify how it affects the sonar's parameters. The results...
-
Doppler estimation method for moving target location
PublicationArtykuł opisuje nowy algorytm lokalizacji obiektów ruchomych bazujących na analizie odchyłek dopplerowskich sygnałów odebranych z sieci hydrofonów rozmieszczonych równomiernie w obserwowanym akwenie. Źródłem analizowanych sygnałów są fale ciągłe o niskim natężeniu odbite od obiektu ruchomego. W artykule została przedstawiona postać algorytmu oraz wyniki symulacji komputerowych.
-
Educational Dataset of Handheld Doppler Blood Flow Recordings
PublicationVital signals registration plays a significant role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomena as well learn how to correctly process and interpret the data. This dataset was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly acquired signals as well as the basic methods of signal processing. This...
-
The Doppler effect in a bistatic system for determining the position of moving targets
PublicationThe article presents the theoretical analysis and the results of numerical calculations of the Doppler effect it occurs in a system designed to determine the position and speed of a moving target. The transmitter is the source of the signal and it emits a sinusoidal, acoustic and continuous wave. Signal reflected off a moving target is received by four hydrophones. Based on the signals, four Doppler shifts are determined and inserted...
-
Underwater Navigation System Based on Doppler Shifts of a Continuous Wave
PublicationThe paper describes a concept of an underwater navigation system designed to determine the location and speed of its ROVs or divers. Conducted by the Department of Marine Electronic Systems at the Gdansk University of Technology for several years, research has focused on navigation systems which determine positions on the basis of Doppler shifts of echo signals reflected from a moving object. This article presents a different version...
-
Receiver of Doppler multistatic system for moving target detection and tracking
PublicationThe article presents a method for solving major structural problems that occur in the receiver used in the multistatic Doppler system, aimed at determination of the trajectory and velocity of a moving target. In the system two transmitters emit acoustic continuous sinusoidal waves at different frequencies. The signals, scattered from a moving target are received by four hydrophones. Beside of the echoes, much larger signals coming...
-
Underwater Navigation Ssystem Based on Doppler Shift – Measurements and Error Estimations
PublicationA new acoustic navigation system was developed to determine the position and speed of moving underwater objects such as divers and underwater vehicles. The path of an object and its speed were determined by the Doppler shifts of acoustic signals emitted by a transmitter placed on the object and received by four hydrophones installed at the periphery of the monitored body of water. The position and speed measurements were affected...
-
Evaluating the effectiveness of Doppler frequency shift determination using pilots in broadband transmission
PublicationIn underwater communications, reciprocal motion between transmitter and receiver has a significant impact on reception quality. In orthogonal broadband systems that provide high bit rates, this problem becomes more important, especially in the higher frequency range, where the absolute Doppler shift is the greatest. Due to the low propagation speed of acoustic wave underwater, a substantial difference exists between the Doppler...
-
Comparison of Doppler Effect Estimation Methods for MFSK Transmission in Multipath Hydroacoustic Channel
PublicationUnderwater wireless communication remains a challenging topic, particularly for applications such as wreck penetration where multipath and Doppler effects are very intense. These effects are becoming even more difficult to mitigate for fast data transmission systems that utilize wideband signals. Due to the low propagation speed of acoustic wave in the water, there is a significant difference between the Doppler shift for lower...
-
Suppression of distortions in signals received from Doppler sensor for vehicle speed measurement
PublicationDoppler sensors are commonly used for movement detection and speed measurement. However, electromagnetic interference and imperfections in sensor construction result in degradation of the signal to noise ratio. As a result, detection of signals reflected from moving objects becomes problematic. The paper proposes an algorithm for reduction of distortions and noise in the signal received from a simple, dual-channel type of a Doppler...
-
Visualizing Carotid Bodies With Doppler Ultrasound Versus CT Angiography: Preliminary Study
PublicationOBJECTIVE. The purpose of this article is to evaluate the utility of ultrasound in identifying carotid bodies (CBs) in patients with drug-resistant arterial hypertension. SUBJECTS AND METHODS. We enrolled 13 patients with drug-resistant hypertension into a trial for surgical CB excision. CT angiography (CTA) and Doppler ultrasound (DUS) of the cervical arteries were performed before surgery. CBs were identified in a blind manner...
-
Doppler blood flow recordings
Open Research DataVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
Approximate Cramér–Rao bound on Doppler error in correlation-processing relatively narrowband noise radar
PublicationThe paper studies limitations on accuracy of Doppler estimation in continuous-wave noise radar with correlation processing. Second order properties of output of the correlation receiver are evaluated and an approximate Cram´er-Rao bound on errors of Doppler measurement is derived. The accuracy of Doppler measurements is found to be affected by the following factors: power spectral density of noise signal, frequency response of the...
-
Estimating Traffic Intensity Employing Passive Acoustic Radar and Enhanced Microwave Doppler Radar Sensor
PublicationInnovative road signs that can autonomously display the speed limit in cases where the trac situation requires it are under development. The autonomous road sign contains many types of sensors, of which the subject of interest in this article is the Doppler sensor that we have improved and the constructed and calibrated acoustic probe. An algorithm for performing vehicle detection and tracking, as well as vehicle speed measurement,...
-
Comparing traffic intensity estimates employing passive acoustic radar and microwave Doppler radar sensor
PublicationThe purpose of our applied research project is to develop an autonomous road sign with built-in radar devices of our design. In this paper, we show that it is possible to calibrate the acoustic vector sensor so that it can be used to measure traffic volume and count the vehicles involved in the traffic through the analysis of the noise emitted by them. Signals obtained from a Doppler radar are used as a reference source. Although...
-
Comparison of perforator location in dynamic and static thermographic imaging with Doppler ultrasound in breast reconstruction surgery
PublicationThis paper co mpares the effectiveness of the dTnorm and t90_10 parametrizations in dynamic thermography for imaging location of perforators in TRAM flaps in the intraoperative period. The results were compared with the location detected in a Doppler ultrasound examination. Cold and heat stimulation was used in dynamic thermography. Additionally, these results were compared with static...
-
Doppler indexes of left ventricular systolic and diastolic function in relation to the arterial stiffness in a general population
Publication -
Time series of Doppler blood flow recordings
Open Research DataVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
Tissue Doppler indexes of left ventricular systolic function in relation to the pulsatile and steady components of blood pressure in a general population
Publication -
The influence of the grid density of measurement points on damage detection in an isotropic plate by the use of elastic waves and laser scanning Doppler vibrometry
PublicationDamage detection in structural components, especially in mechanical engineering, is an 2 important element of engineering practice. There are many methods of damage detection, in which 3 changes in various parameters caused by the presence of damage are analysed. Recently, methods 4 based on the analysis of changes in dynamic parameters of structures, i.e. frequencies or mode shapes 5 of natural vibrations, as well as changes in...
-
Time frequency representation of Doppler boold flow recordings
Open Research DataVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
Efekt dopplera w systemach hydrolokacyjnych
PublicationReferat zawiera przegląd problematyki zjawiska Dopplera w systemach hydrolokacyjnych. Przegląd poprzedzony jest omówieniem efektu Dopplera w kategorii kompresji czasu. Następnie przedstawiono metody wykorzystania zjawiska Dopplera do pomiaru prędkości ruchu i położeniaobserwowanych obiektów oraz wykorzystanie tego zjawiska w sonarach z syntetyczną aperturą. W drugiej części referatu omówiono negatywne skutki zjawiska Dopplera i...
-
Multistatyczny, Dopplerowski System określania położenia i prędkości ruchomych celów w wodzie
PublicationW omawianym w pracy multistatycznym, dopplerowskim systemie określania położenia i prędkości ruchomych celów w wodzie źródłem sygnału są dwa nadajniki emitujące sinusoidalne, akustyczne fale ciągłe o różnych częstotliwościach, które po odbiciu od ruchomego celu są obierane przez cztery hydrofony. W artykule przedstawiono analize teoretyczna efektu Dopplera, na którym oparte jest działanie systemu oraz metodę rozwiązania głównych...
-
Szyk planarny anten mikropaskowych z przeznaczeniem do radaru dopplerowskiego
Publicationw pracy opisano konstrukcję oraz wyniki pomiarów szyku 4 anten mikropaskowych w postaci macierzy 2x2 na częstotliwość 10 ghz, z przeznaczeniem do pracy w układzie radaru dopplerowskiego. pojedynczym promiennikiem w omawianym szyku jest antena mikropaskowa, zasilana przez sprzężenie elektromagnetyczne realizowane przez szczelinę we wspólnym ekranie. wykorzystanie szyku w układzie radaru dopplera stwarza wymagania w stosunku do charakterystyk...
-
Szyk planarny anten mikropasokwych z przeznaczeniem do radaru dopplerowskiego
PublicationW pracy opisano konstrukcję oraz wyniki pomiarów szyku 4 anten mikropaskowych w postaci macierzy 2x2, zaprojektowanych na częstotliwość 10 GHz. Pojedynczym promiennikiem w szyku jest antena mikropaskowa , zasilana przez sprzężenie elektromagnetyczne realizowane przez szczelinę we wspólnym ekranie. W wyniku badań zrealizowanych 3 egzemplarzy szyku stwierdzono, że niewielkie odchyłki w wymiarach fizycznych badanych układów przełożyły...
-
Badania możliwości wyznaczania położenia i prędkości ruchomych obiektów pływających z wykorzystaniem odchyłek dopplerowskich sygnałów akustycznych
PublicationCelem rozprawy było zbadanie możliwości budowy hydroakustycznych systemów nawigacyjnych, których działanie opiera się wyłącznie na pomiarach odchyłek dopplerowskich sygnałów akustycznych emitowanych przez obiekty poruszające się pod wodą. Rozpatrywano dwie wersje systemu: pierwszego opartego na analizie sygnału emitowanego przez nadajnik zainstalowany na ruchomym obiekcie oraz drugiego opartego na analizie sygnału emitowanego...
-
Measurement of distance, velocity and angle of arrival using FMCW-CW combined waveform
PublicationA procedure of tacking small flying object based on a general principle of FMCW and Doppler radar is presented. In order to increase measurement range, this technique uses active signal source on the moving object. For simultaneous measurements of distance, radial velocity and direction (AoA) as well as simplified synchronization a combined FMCW-CW waveform is proposed. The presented measurement system was realized and verified...
-
Application of Maximum Lenght Sequence in Silent Sonar
PublicationSilent sonars are designed to reduce the distance over which their sounding pulses can be detected by intercept sonars. In order to meet this objective, we can use periodical sounding signals that have low power, a very long duration and wide spectrum. If used in the silent sonar's receiver, matched filtration ensures very good detection of motionless or slow moving targets. However, it is more difficult to detect echo signals...
-
Experimental Study of Silent Sonar
PublicationStealth is a frequent requirement in military applications and involves the use of devices whose signals are difficult to intercept or identify by the enemy. The silent sonar concept was studied and developed at the Department of Marine Electronic Systems of the Gdansk University of Technology. The work included a detailed theoretical analysis, computer simulations and some experimental research. The results of the theoretical...
-
New method to monitor changes in the subarachnoid width and pial artery pulsation for physiological and clinical research
PublicationThere are several medical conditions associated with brain oedema such as traumatic brain injury, intoxication or tumors. Brain edema and related brain parenchyma expansion may lead to compression and subsequent injury of several brain structures. So far, the only method enabling detection and monitoring of the progress a cerebral oedema in a patient, has been monitoring of intracranial pressure (ICP) with a pressure probe inserted...
-
Velocity Field Characteristics at the Inlet to a Pipe Culvert
PublicationA poorly designed culvert inlet structure causes scouring, which can lead to the collapse of the culvert and significant damage to the neighboring land. A set of laboratory tests was evaluated to examine velocity distribution at the culvert inlet. A three-dimensional acoustic Doppler velocimeterwas used to measure instantaneous flowvelocity upstream of the culvert. The analysis of mean velocities, turbulence strength, and Reynolds...
-
numerical prediction of vortex generated by hydrofoil
PublicationW pracy przedstawiono wyniki obliczeń programami Fluent i Comet dla płata śruby napędowej. Pola prędkości oraz wirowość za płatem porównano z wynikami pomiarów (LDA- Laser Doppler Anemometry) w tunelu kawitacyjnym Centrum Techik Okrętowych (CTO). Przedstawiono wpływ adaptacji siatki wg różnych kryteriów (lokalnej wirowości lub prędkości) na zgodność wyników obliczeń z danymi eksperymentalnymi.
-
Silent Sonar with matched filtration
PublicationRadars with continuous wave frequency (CW FM sonars) are used in radiolocation as 'silent sonars'. They determine the distance to target by measuring the difference between the frequency of the sounding signal and echo signal. The article presents the principle of operation and parameters of silent CW FM sonars. Target distance determined by these sonars is based on the signal at the output of the matched filter. The Doppler effect...
-
Using Fast Frequency Hopping Technique to Improve Reliability of Underwater Communication System
PublicationAcoustic underwater communication systems designed to work reliably in shallow coastal waters must overcome major limitations such as multipath propagation and the Doppler effect. These restrictions are the reason for the complexity of receivers being built, whose task is to decode a symbol on the basis of the received signal. Additional complications are caused by the low propagation speed of the acoustic wave in the water and...
-
Detection of damages in a rivetted plate
PublicationThe paper presents the results of damage detection in a riveted aluminium plate. The detection method has been based on Lamb wave propagation. The plate has been analysed numerically and experimentally. Numerical calculations have been carried out by the use of the time-domain spectral finite element method, while for the experimental analysis laser scanning Doppler vibrometry (LSDV) has been utilised. The panel has been excited...
-
Damage localisation in a stiffened plate structure using a propagating wave
PublicationThe paper presents an application of changes in propagating waves for damage detection in a stiffened aluminium plate. The experimental investigation was conducted on an aluminium plate with riveted two L-shape stiffeners. The wave has been excited with a piezoelectric transducer and measured with the Laser Scanning Doppler Vibrometer. Recorded signals were analysed using the special signal processing techniques developed for damage...
-
A concept of software extension of 3D low-PRF radar systems to 4D semi-medium-PRF radar systems
PublicationWe present a concept of software modification of three-dimensional (3D) radar systems, designed to work in the low pulse repetition frequency mode, that equips them with the ability to estimate the radial velocity and to properly measure the range of targets that are detected outside the radar’s instrumented range. Despite the fact that the proposed modifications are designed so as to require only minor changes in software, they...
-
Measurements of guided wave propagation in CFRP/steel adhesive joints obtained by scanning laser vibrometry
Open Research DataThe DataSet contains guided wave signals measured in adhesive joints of steel plates (steel of type S355 with a thickness of 11.9 mm ) and carbon fibre reinforced polymer (CarboDur S1012 with a thickness of 1.24 mm). The samples were as follows: #0 – intact; #1 – 10% disbond; #2 – 20% disbond; #3 – 50% disbond; #4 – 80% disbond; #5 – 100% disbond.
-
Mutual Clutter Suppression Techniques for FM Sonars
PublicationThe article presents methods that help in the elimination of mutual clutter as well as the consequences of two FM sounding signal sonars operating in the same body of water and frequency band. An in-depth analysis of mutual clutter was carried out. The effects of sounding signal differentiation were determined, as was the Doppler effect on mutual clutter suppression. One of the methods analysed is of particular interest in a situation...
-
Continuous wave sonar with hyperbolic frequency modulation keyed by pseudo-random sequence
PublicationA CW FM type sounding signal is used in the classical solution of silent sonar. While the signal provides a relatively simple implementation of digital signal processing, and ensures good detection conditions, unfortunately, in the presence of the Doppler effect, distance measurement results tend to be wrong. This is due to the fact that the received signal’s instantaneous frequency value is dependent both on the distance to the...
-
Probe signal processing for channel estimation in underwater acoustic communication system
PublicationUnderwater acoustic communication channels are characterized by a large variety of propagation conditions. Designing a reliable communication system requires knowledge of the transmission parameters of the channel, namely multipath delay spread, Doppler spread, coherence time, and coherence bandwidth. However, the possibilities of its estimation in a realtime underwater communication system are limited, mainly due to the computational...
-
A Comparison of Simplified Two-dimensional Flow Models Exemplified by Water Flow in a Cavern
PublicationThe paper shows the results of a comparison of simplified models describing a two-dimensional water flow in the example of a water flow through a straight channel sector with a cavern. The following models were tested: the two-dimensional potential flow model, the Stokes model and the Navier-Stokes model. In order to solve the first two, the boundary element method was employed, whereas to solve the Navier-Stokes equations, the...
-
Pomiarowa analiza drgań tarcz łożyskowych silników asynchronicznych laserem skanującym SLDV
PublicationArtykuł przedstawia analizę pomiarową tarcz łożyskowych silników asynchronicznych badanych przy wykorzystaniu lasera skanującego SLDV (Scanning Laser Doppler Vibrometer) na przykładzie urządzenia Polytec PSV-400. Przedstawiono istotę problemu drgań wibroakustycznych małych silników asynchronicznych powszechnie spotykanych w przemyśle. Przedstawione zostały teoretyczne wyliczone reluktancyjne składowe naprężeń promieniowych oddziałowujące...
-
Impact of surface skin temperature change on blood flow characteristics in palm
PublicationHeating a human palm during 3 minutes period causes changes in superficial skin temperature and leads to thermoregulation system response. The response time and level of flow characteristics change depend on the subject hand size and health of his vascular tree. A solution of Pennes bioheat propagation model was analyzed in order to see how much heat has to be transferred into the tissue to extort the observable reaction. The reflective...
-
Diagnostics of the Peripheral Artery Disease with use of Glucose Sensor - A Proof of Concept
PublicationIt is estimated that 13% of population over 50 years old suffer from symptomatic or asymptomatic peripheral artery disease (PAD). Ankle-brachial index (ABI) is viewed as a useful parameter in diagnostics of peripheral arterial disease, however screening tests with usage of this method are not advised. Hypoxia causes increase in lactate values and decrease in blood glucose. We hypothesize that the deficit in blood supply to the...
-
Counting and tracking vehicles using acoustic vector sensors
PublicationA method is presented for counting vehicles and for determining their movement direction by means of acoustic vector sensor application. The assumptions of the method employing spatial distribution of sound intensity determined with the help of an integrated 3D intensity probe are discussed. The intensity probe developed by the authors was used for the experiments. The mode of operation of the algorithm is presented in conjunction...
-
Measurement of Impulse Response of Shallow Water Communication Channel by Correlation Method
PublicationPerformances of underwater acoustic communication (UAC) systems are strongly related to specific propagation conditions of the underwater channel; conditions that can additionally change in time due to the movement of the acoustic system transmitter and receiver or to reflection by underwater objects of the transmitted signal. The time-varying impulse response is a comprehensive description of dynamically changing transmission...
-
Frequency Guided Generalized Adaptive Notch Filtering - Tracking Analysis and Optimization
PublicationGeneralized adaptive notch filters (GANFs) are estimators of coefficients of quasi-periodically time-varying systems, encountered e.g., in RF applications when Doppler effect takes place. Current state of the art GANFs can deliver highly accurate estimates of system variations’ frequency, but underperform in terms of accuracy of system coefficient estimates. The paper proposes a novel multistage GANF with improved coefficient...
-
Diagnostics of the Peripheral Artery Disease with use of Glucose Sensor - A Proof of Concept
PublicationIt is estimated that 13 % of population over 50 years old suffer from symptomatic or asymptomatic peripheral artery disease (PAD). Ankle-brachial index (ABI) is viewed as a useful parameter in diagnostics of peripheral arterial disease, however screening tests with usage of this method are not advised. Hypoxia causes increase in lactate values and...
-
Detection and Imaging of Debonding in Adhesive Joints of Concrete Beams Strengthened with Steel Plates Using Guided Waves and Weighted Root Mean Square
PublicationStrengthening of engineering structures is an important issue, especially for elements subjected to variable loads. In the case of concrete beams or slabs, one of the most popular approaches assumes mounting an external reinforcement in the form of steel or composite elements by structural adhesives. A significant disadvantage of adhesive joints is the lack of access to the adhesive film for visual condition assessment, thus, there...