displaying 1000 best results Help
Search results for: plate heat exchanger
-
Numerical modeling of cross-flow heat exchanger for air-conditioning purposes in preliminary study.
PublicationPraca przedstawia wyniki obliczeń numerycznych krzyżowego płytowo-rurowego wymiennika ciepła przeznaczonego do celów klimatyzacyjnych w początkowym etapie jego projektowania.
-
Monitoring Regenerative Heat Exchanger in Steam Power Plant by Making Use of the Recurrent Neural Network
PublicationArtificial Intelligence algorithms are being increasingly used in industrial applications. Their important function is to support operation of diagnostic systems. This paper pesents a new approach to the monitoring of a regenerative heat exchanger in a steam power plant, which is based on a specific use of the Recurrent Neural Network (RNN). The proposed approach was tested using real data. This approach can be easily adapted to...
-
Corrosion-erosion damage of heat exchanger tubes by desalted crude oil flowing at shell side
Publication -
Corrosion-erosion damage of heat exchanger tubes by desalted crude oil flowing at shell side.
PublicationRurki wymiennika zostały uszkodzone lokalnie przez odsoloną ropę naftową przepływającą pod ciśnieniem 2,6 MPa i w temperaturze 385-395K. Większość powierzchni rurek nie była uszkodzona i była pokryta osadem związków organicznych i nieorganicznych, zabezpieczającym przed uszkodzeniami. Badania wykluczyły możliwość występowania intensywnej korozji elektrochemicznej na powierzchniach rurek pozbawionych osadu. Przyczyną perforacji...
-
Flow visualization and heat transfer investigations on the flat plate with streamwise pressure gradient
PublicationPaper presents experimental investigations results for film cooling on a flat plate. The main objective of the design is the streamwise pressure distribution on the flat plate as in the blade cascade. The transient and steady-state technique with liquid crystals for the surface temperature distribution with film cooling has been used in experiments in a low speed wind tunnel.
-
The effect of plate size on the natural convective heat transfer intensity of horizontal surfaces
PublicationW pracy przedstawiono badania wpływu rozmiarów płyty prostokątnej poziomej na intensywność wymiany ciepła w warunkach konwekcji swobodnej. Zaproponowano dwa zakresy: dla płyt o wymiarze charakterystycznym mniejszym niż 0,1 m - 0,2 m intensywność konwekcyjnej wymiany ciepła jest odwrotnie proporcjonalna do szerokości płyty, dla płyt szerszych niż 0,2 m szerokość płyty nie wpływa znacząco na współczynnik konwekcyjnej wymiany ciepła....
-
Thermal and economic investigation of straight and U-bend double tube heat exchanger with coiled wire turbulator
PublicationExperimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800–9000 – on the shell side, for a constant cold water temperature of 9 ◦C and hot water of 50 ◦C. The heat exchangers were made from copper tubes with...
-
Experimental investigation on straight and u-bend double tube heat exchanger with active and passive enhancement methods
PublicationAuthors in this work want to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. In the study, Wilson plot approach was applied in order to estimate heat transfer coefficients for all heat exchanger (HX) configurations. The study focuses on experimental values of heat transfer coefficient...
-
ATTEMPTS OF THERMAL IMAGING CAMERA USAGE IN ESTIMATIONS OF THE CONVECTIVE HEAT LOSS FROM A VERTICAL PLATE
PublicationIn this paper a new method for determining heat transfer coefficients using a gradient method has been developed. To verify accuracy of the proposed method vertical isothermal heating plate with natural convection mechanism has been examined. This configuration was deliberately chosen, because of the fact that such case is historically the earliest and most thoroughly studied and its rich scientific documentation - the most reliable....
-
Possibility of thermal imaging use in studies of natural convection heat transfer on the example of an isothermal vertical plate.
PublicationA new method of infrared (IR) camera use in convective heat transfer studies has been presented. Until now, IR cameras were utilized for temperature field visualizations of flat heated surfaces of solid objects only. Because liquids and gasses do not emit radiation in the infrared range of wave lengths, detection of temperature field in the air was conducted with the use of plastic mesh, which, after heating by hot air, emits infrared...
-
Improved finite element method for flow, heat and solute transport of Prandtl liquid via heated plate
PublicationIn the current study, a vertical, 3D-heated plate is used to replicate the generation of heat energy and concentration into Prandtl liquid. We discuss how Dufour and Soret theories relate to the equations for concentration and energy. In order to see how efectively particles, interact with heat and a solvent, hybrid nanoparticles are used. It does away with the phenomena of viscous dissipation and changing magnetic felds. The motivation...
-
Possibility of thermal imaging use in studies of natural convection heat transfer on the example of an isothermal vertical plate
Publication -
Theoretical consideration of free convective heat transfer from a round isothermal plate slightly inclined from the vertical
PublicationA semi-analytical solution of simplified Navier-Stokes and Fourier-Kirchhoff equations describing free convective heat transfer from a round isothermal surface slightly inclined from the vertical is presented. The solution is based on the assumption, typical for natural convection, that the velocity component normal to the surface is negligibly small in comparison to the tangential one. Next we neglect the nonlinear inertia force...
-
Simulation of hybridized nanofluids flowing and heat transfer enhancement via 3-D vertical heated plate using finite element technique
PublicationThe present study probed the creation of heat energy and concentrating into Newtonian liquids across vertical 3D-heated plates. The role of the Soret and Dufour theories in concentrating and energy formulas is discussed. The role of hybrid nanoparticles is introduced to illustrate particle efciency in terms of solute and thermal energy. It is removed a viscous dissipation process and a changing magnetic feld. The proposed approach...
-
Thermal-FSI modeling of flow and heat transfer in a heat exchangerbased on minichanels
PublicationIn this paper selected numerical modelling problems for an advanced thermal-FSI ("Fluid Solid Interaction") mini-channel heat exchanger model are presented. Special attention is given to the heat transfer between the separated mediums for different mass flows. Similar modelling problems have also been discussed in the literature dedicated to numerical and theoretical modelling problems for typical heat exchangers [1, 2, 3]. Basic...
-
Flow distribution and heat transfer in minigap and minichannel heat exchangers during flow boiling
PublicationThe topic of boiling heat transfer in miniscale geometries has focused the ever increasing interest of researchers in recent years. However, most of the works are related to mini- and microchannels and much less to minigaps. Meanwhile, minigaps allow for more comprehensive experimental studies, i.e. flow visualisations due to the flat, two-dimensional configuration of the flow. The results of the experimental investigations of...
-
Recuperator with microjet technology as a proposal for heat recovery from low-temperature sources
PublicationA tendency to increase the importance of so called dispersed generation, based on the local energy sources and the working systems uti- lizing both the fossil fuels and the renewable energy resources is observed nowadays. Generation of electricity on industrial or domestic scale together with production of heat can be obtained for example through employment of the ORC systems. It is mentioned in the EU directive 2012/27/EU for...
-
Recuperator with microjet technology as a proposal for heat recovery from low-temperature sources
PublicationA tendency to increase the importance of so called dispersed generation, based on the local energy sources and the working systems utilizing both the fossil fuels and the renewable energy resources is observed nowadays. Generation of electricity on industrial or domestic scale together with production of heat can be obtained for example through employment of the ORC systems. It is mentioned in the EU directive 2012/27/EU for cogenerative...
-
Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator
PublicationTwo-dimensional numerical investigations of the fluid flow and heat transfer have been carried out for the laminar flow of the louvered fin-plate heat exchanger, designed to work as an air-source heat pump evap- orator. The transferred heat and the pressure drop predicted by simulation have been compared with the corresponding experimental data taken from the literature. Two dimensional analyses of the louvered fins with varying...
-
Application of nanofluids in thermal technologies
PublicationNanofluids it is a relatively new category of thermal fluids that can serve as coolants, both in single- and two phase systems. However application of nanofluids in industrial applications requires faultless their thermophysical properties. Existing models originally developed for liquid/solid particles mixtures (slurries) fail in case of nanofluids. Moreover correlations used to calcuate heat transfer coefficients of conventional...
-
CHARAKTERYSTYKA WYMIANY CIEPŁA I OPORÓW PRZEPŁYWU OMYWANIA MIKROSTRUGAMI ROZWINIĘTEJ POWIERZCHNI
PublicationW artykule przedstawiono eksperymentalne badania kompaktowego wymiennika ciepła z intensyfikacją przejmowania ciepła przy użyciu mikrostrug. Niniejszy artykuł przedstawia projekt i testy prototypu, wymiennika ciepła typu mikrostrugowego. Modułowa konstrukcja wymiennika umożliwia zmianę wymiarów geometrycznych, a także zmianę materiału przegrody wymiennika ciepła. Metoda graficzna Wilsona została z zastosowana w celu określenia...
-
Analytical and reliability data from the real-time simulator biogas plant
Open Research DataThe dataset represents the results of biogas plant simulation. The described plant is an agricultural biogas system, which can produce electrical energy with power estimated up to 1070 kW and heat energy that can reach 1200 kW simultaneously.
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 85
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 40
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 90 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 70
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a rectangular manifold, condenser temperature 30 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 70 and evaporator temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 95
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
INTENSYFIKACJA WYMIANY CIEPŁA W WYMIENNIKU WĘŻOWNICOWYM Z WYKORZYSTANIEM PRZEGRÓD O RÓŻNEJ GEOMETRII
PublicationW pracy zaprezentowano możliwości wykorzystania pasywnej intensyfikacji wymiany ciepła w postaci przegród dla podniesienia efektywności energetycznej wymiennika wężownicowego. Badania zostały przeprowadzone z wykorzystaniem modułowego wymiennika z wężownicą w postaci grzałki elektrycznej. Medium odbierającym ciepło była woda o stałych parametrach cieplnoprzepływowych na wlocie do modułu. Pomiary przeprowadzono dla szerokiego zakresu...
-
The topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope
Open Research DataThe topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope.
-
The morphology of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with AFM
Open Research DataThe morphology of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses was measured with the use of atomic force microscope.
-
The topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with AFM
Open Research DataThe topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with AFM.
-
The topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with confocal microscope
Open Research DataThe topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with confocal microscope.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at 273 K
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times measured with impedance spectroscopy method at low temperatures
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K was measured by impedance spectroscopy method.
-
The structure of vanadate glass-ceramics containing BaTiO3 measured with X-ray diffraction method
Open Research DataThe structure of vanadate glass-ceramics doped with BaTiO3 was measured by XRD. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated...
-
Jan Wajs dr hab. inż.
People -
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 813 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties as a function of A.C. voltage of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat treated at 813 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of Bi2VO5.5 glass-ceramic heat-treated at 913 K was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 glass-ceramic heat-treated at 913 K was measured by impedance spectroscopy method.
-
The morphology of vanadate glass-ceramics containing BaTiO3 measured with the use of AFM
Open Research DataThe structure of vanadate glass-ceramics doped with BaTiO3 was measured by AFM technique. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on...
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 3 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 10 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
The topography of Bi2VO5.5 ceramics prepared by melt-quenching technique was measured with confocal microscope
Open Research DataThe topography of Bi2VO5.5 ceramics prepared by melt-quenching technique was measured by confocal microscope.
-
Charakterystyka eksploatacyjna pomp ciepła zainstalowanych w oczyszczalni ścieków
PublicationW artykule przedstawiono charakterystykę eksploatacyjną sprężarkowych pomp ciepła zainstalowanych w oczyszczalni komunalnej i wykorzystujących ścieki oczyszczone jako dolne źródło ciepła. Zastosowanie ścieków oczyszczonych jest uzasadnione ich dostępnością oraz stosunkowo wysoką temperaturą (10-25°C). Prawidłowa eksploatacja układu wymaga zastosowania pośredniego obiegu parowacza oraz regularnych zabiegów czyszczenia wymiennika...