Experimental study of flow boiling pressure drop and heat transfer of R1233zd(E) at moderate and high saturation temperatures
PublicationThe paper presents the results of experimental study of flow boiling of R1233zd(E) in minichannel at moderate and high saturation temperatures. The heat transfer coefficient and pressure drop were measured for flow boiling in a stainless steel tube with 2 mm inside diameter and a length of 300 mm. Experiment has been conducted for saturation temperatures ranging from 83 to 145 °C which corresponds to values of reduced pressures...
-
Stabilitě des coques lasto-viscoplastiques en grandes rotations soumises aux charges dynamiques et temperatures variables.
PublicationPrzeanalizowano stabilność powłoki walcowej poddanej obciążeniu równomiernie rozłożonemu. Przeanalizowano wpływ temperatury na wielkość obciążenia krytycznego. W obliczeniach metodą elementów skończonych zastosowano lepkoplastyczne związki konstytutywne.
-
Glass transition temperatures of polyurethane-urea elastomers based on N, N′-ethylenethiourea and N, N′-ethyleneurea as chain extenders
Publication -
Analyse du comportement des coques elastoviscoplastiques en grandes rotations soumisses aux charges dynamiques et temperatures variables.
PublicationPrzeanalizowano wpływ temperatury na zachowanie się panelu cylindrycznego. Obliczenia przeprowadzono w zakresie dużych przemieszczeń i obrotów z uwzględnieniem wpływu temperatury na lepkoplastyczne zależności konstytutywne (model Chaboche´a).
-
Analytical method of determining dynamic properties of thermocouples used in measurements of quick – changing temperatures of exhaust gases in marine diesel engines
PublicationThe article presents selected issues of mathematical modeling of heat exchange between the thermocouple and the exhaust gas flowing them, in unsteady conditions. On the way of energy balancing consideration of thermodynamic processes developed differential equations describing the dynamic properties for three versions of the design sheathed thermocouples: with weld isolated from the sheath, with weld welded the sheath and with...
-
Wpływ podwyższonych temperatur na napawane warstwy na bazie kobaltu = The elevated temperatures influence on the cobalt base cladding layer
Publicationw pracy przeanalizowano wpływ temperatur utleniania (850, 950 i 110 stopni C) na mikrostrukturę i twardośc napawanych plazmowo warstw zykonanych z proszku na bazie kobaltu zdodatkiem 28,8% chromu, 4,9% wolframu, 2,2% niklu, 2,09% żelaza, 1,2% krzemu i 1,2% węgla. W wyniku utleniania na powierzchni napoiny powstaje warstwa tlenku chromu stanowiaca dobrą ochronę w niższych temperaturach, jednak w temperaturach wyższych ulega ona...
-
Electron Density from Balmer Series Hydrogen Lines and Ionization Temperatures in Inductively Coupled Argon Plasma Supplied by Aerosol and Volatile Species
Publication -
Low temperature cracking equipment: Termal Stress Restrained Specimen Test (TSRST); Uniaxial Tensile Strength Test (UTST); Tensile Creep Test (TCT); Relaxation Test (RT);
Research Equipment -
Dynamic Behavior of Aluminum Alloy Aw 5005 Undergoing Interfacial Friction and Specimen Configuration in Split Hopkinson Pressure Bar System at High Strain Rates and Temperatures
Publication -
Research of hydraulic axial piston pump at low ambient temperatures
Open Research DataPresented data include the results of measurements of oil temperature at the inlet and outlet of the hydraulic pump (theoretical displacement is equal to 16 cm3/rev) , temperature of the heated pump and oil pressure at the inlet and outlet of the pump.
-
The XRD diffraction patterns of LSCNT sintered at various temperatures
Open Research DataThe dataset includes XRD diffraction patterns of La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s sintered at various temperatures under air atmosphere for 12 h. Samples were produced using aqueous soft chemistry methods (Pechini).
-
Effect of the Cooling Time in Annealing at 350°C on the Phase Transformation Temperatures of a Ni<sub>5</sub><sub>5</sub>Ti<sub>4</sub><sub>5</sub> wt. Alloy
Publication -
X-ray diffraction of ZnIn2S4 layers on TiO2NT and FTO annealed at different temperatures
Open Research DataData show XRD results for ZnIn2S4 layers deposited using hydrothermal method on FTO glass and TiO2 nanotubes. The layers were annealed in air atmosphere at 300, 400 and 500 oC.
-
Pore size distribution of PC-X (porous carbon materials obtained at various temperatures)
Open Research DataThese data contain pore size distribution of PC-700 (porous carbon materials obtained at 700°C), PC-800 (porous carbon materials obtained at 800°C) and PC-900 (porous carbon materials obtained at 900°C) analyzed by the nitrogen adsorption/desorption technique.
-
SEM images of cross sections of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains cross sectional images of the porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes symmetric cells samples interface. Here are presented images of electrodes sintered at 950 °C, 1000 °C and 1050 °C. Images were obtained using a FEI Quanta FEG 250 Scanning Electron Microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum...
-
Series resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces area.
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.50Fe0.50O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.50Fe0.50O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.30Fe0.70O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
The XRD diffraction patterns of reduced LSCNT prepared using two methods and two sintering temperatures
Open Research DataThe dataset includes XRD diffraction patterns of La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s produced using two methods, namely organic (citrate assisted) and Pechini sintered at 1000 or 1200oC under air atmosphere and reduced at 900 for 12 h in wet H2.
-
Vibration signals collected for concrete beams with GFRP reinforcement subjected to elevated temperatures (120C-240C)
Open Research DataThe dataset contains the time domain signals obtained during dynamic tests of concrete beams reinforced with GFRP bars. The vibration were induced with the use of modal hammer, while the signals were collected by the accelerometers attached at the beam surface. The signals were captured before and after subjecting the concrete beams to elevated temperatures.
-
Area specific resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.50Fe0.50O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.50Fe0.50O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.30Fe0.70O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
Scanning Electron Microscopy (SEM ) images of PC-X (porous carbon materials obtained at various temperatures)
Open Research DataThese data contain SEM (scanning electron microscopy) images of PC-700 (porous carbon materials obtained at 700°C), PC-800 (porous carbon materials obtained at 800°C) and PC-900 (porous carbon materials obtained at 900°C).
-
Nitrogen (N2) adsorption/desorption isotherms of PC-X (porous carbon materials obtained at various temperatures)
Open Research DataThese data contain nitrogen (N2) adsorption/desorption isotherms of PC-700 (porous carbon obtained at 700 °C), PC-800 (porous carbon obtained at 800°C), PC-900 (porous carbon materials obtained at 900°C). Data showed typical type-I isotherms, indicating the presence of micropores in their structures. PC-900, compared with PC-700 and PC-800, showed a...
-
X-ray Diffraction (XRD) patterns of PC-X (porous carbon materials obtained at various temperatures)
Open Research DataThese data contain X-ray diffraction patterns (XRD) of PC-700 (porous carbon materials obtained at 700°C), PC-800 (porous carbon materials obtained at 800°C) and PC-900 (porous carbon materials obtained at 900°C).
-
Raman spectra of PCMCA-X (potassium citrate derived porous carbon materials obtained at various temperatures of carbonization)
Open Research DataThese data contain Raman spectra of PCMCA-700 (potassium citrate derived porous carbon materials obtained at 700°C ), PCMCA-800 (potassium citrate derived porous carbon materials obtained at 800°C ), PCMCA-900 (potassium citrate derived porous carbon materials obtained at 900°C ). The D peak at 1340 cm−1 and the G peak at 1592 cm−1 can be seen in all...
-
CO2 adsorption isotherms on PCMCA-X (potassium citrate derived porous carbon materials obtained at various temperatures of carbonization)
Open Research DataThis dataset contains static CO2 adsorption isotherms on PCMCA-700 (potassium citrate derived porous carbon material obtained at 700 °C), PCMCA-800 (potassium citrate derived porous carbon material obtained at 800 °C), PCMCA -900 (potassium citrate derived porous carbon material obtained at 900 °C) adsorbents.
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times measured with impedance spectroscopy method at low temperatures
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times was measured by impedance spectroscopy method.
-
CO2 uptake capacities of PCMCA-900 (potassium citrate-derived porous carbon prepared at 900 °C) adsorbent at various temperatures
Open Research DataThese data contain CO2 uptake capacities of PCMCA-900 (potassium citrate-derived porous carbon prepared at 900 °C) adsorbent at various temperatures. Adsorption experiments were carried out at temperatures 0 °C, 25 °C, and 50 °C at 1 bar.
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
XPS (X-ray photoelectron spectroscopy) spectra and high-resolution spectra of C 1 s and O 1 s of the PCMCA-X (potassium citrate derived porous carbon materials obtained at various temperatures)
Open Research DataThese data include XPS full spectra and high-resolution spectra of C 1 s and O 1 s of the (potassium citrate derivedporous carbon material obtained at 700 °C), PCMCA-800 (potassium citrate derived porous carbon material obtained at 800 °C), PCMCA (potassium citrate derived porous carbon material obtained at 900 °C). The elemental composition on the...
-
Marek Pszczoła dr hab. inż.
PeopleI am a Faculty member (Department of Highway and Transportation Engineering) at the Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Poland). My main research interests include: low-temperature properties of asphalt mixtures, low temperature cracking assessment of pavement structures, road materials properties, thermal stress analysis, design of pavement structures, airfield design and analysis....
-
Maciej Wierzbowski dr inż.
People -
Piotr Jaskuła dr hab. inż.
PeopleI am a Faculty member (Associate Professor, Highway and Transportation Research Department) at the Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Poland).My main research interests include: pavement structures, interlayer bonding, pavement materials, recycling of road pavements, asphalt mixtures, bitumens, construction and maintenance of pavement structures.My lectures at the University include:...
-
Sebastian Lech Wachowski dr inż.
PeopleBorn in 1987 in Bydgoszcz, Poland. In 2012 graduated MSc in Applied Physics: Nanotechnology and in 2017 finished, with honours, PhD in physics at Gdańsk University of Technology. Since the beginning of his academic journey interested in functional materials, especially in high-tech ceramics. Devoted to the development of high temperature protonic conductors for water vapour electrolyzers and fuel cells. During his career has several...
-
Ewa Klugmann-Radziemska prof. dr hab.
PeopleEwa Klugmann-Radziemska graduated from the University of Gdansk with a degree in physics, and since 1996 has been associated with the Gdansk University of Technology, when she began PhD studies. Currently, he is a professor at the Faculty of Chemistry at the Gdansk University of Technology, since 2006 head of the Department of Chemical Apparatus and Machinery. In the years 2008–2016 she was the Vice-Dean for cooperation and development,...
-
Maciej Łuszczek dr hab. inż.
PeopleMaciej Łuszczek born in 1967 in Gdynia. He received the M.Sc. degree in Applied Physics in 1991, the Ph.D. degree in 1999, and the D.Sc. (‘habilitation’) degree in 2015, all from the Gdańsk University of Technology. Since 1991 he has been with the above university, initially at the Faculty of Applied Physics and Mathematics, Department of Solid State Physics, and currently (since 2015) at the Faculty of Electrical and Control Engineering,...
-
Friction-Induced Oscillations of a Non-Asbestos Organic Pin Sliding on a Steel Disc
PublicationFriction-induced oscillations result in deterioration of performance of disc brakes and are generally undesired. We conduct experimental study of friction-induced oscillations in a non-asbestos organic material / steel pair used in disc brakes of motor vehicles. The tests are done by use of a pin-on-disc machine which has the pin sample supported on a deformable beam. The adjustable friction parameters are the disc velocity, contact...
-
Obrony prac doktorskich na Wydziale Chemicznym
EventsDn. 29.04.2022 r. o godz. 10.00 w Audytorium 1.4 Wydziału Chemicznego PG (budynek nr 5) odbędzie się w trybie hybrydowym obrona pracy doktorskiej mgr. inż. Łukasza Zedlera.
-
Patrycja Puzdrowska dr inż.
PeopleW październiku 2005 r. – rozpoczęcie nauki na Wydziale Mechanicznym Politechniki Gdańskiej, kierunek Mechanika i Budowa Maszyn, studia stacjonarne, jednolite magisterskie. W lipcu 2010 r. – ukończenie studiów o specjalności Urządzenia i Systemy Chłodnicze i Klimatyzacyjne, uzyskanie tytułu magistra inżyniera. W 2012 r. – rozpoczęcie studiów III stopnia w Środowiskowym Studium Doktoranckim, na Wydziale Oceanotechniki i Okrętownictwa,...
-
Wykorzystanie ciepła niskotemperaturowego do procesu suszenia peletu ze słomy z wykorzystaniem mikrostrugowego wymiennika ciepła
PublicationW artykule przedstawiono wpływ temperatury medium suszącego na zmiany względnej oraz bezwzględnej zawartości wilgoci podczas suszenia peletu ze słomy. Proces suszenia przeprowadzono przy stałym ciśnieniu atmosferycznym i różnych wartościach temperatury powietrza, jako czynnika suszącego, wynoszących odpowiednio: 40℃, 60℃, 80℃, 100℃ oraz 120℃. Badania eksperymentalne wykonywano na innowacyjnym stanowisku wyposażonym w mikrostrugowy...
-
Dawid Ryś dr hab. inż.
PeopleCourses PRINCE2® Foundation Certificate in Project Management Tire-Pavement Interaction course Micromechanical Analysis of Asphalt Concrete