Filters
total: 1421
filtered: 1329
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: FAULT IDENTIFICATIONS
-
Tripping limitations of residual current devices in photovoltaic installations
PublicationIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Identification of leaf rust resistance genes Lr34 and Lr46 in common wheat (Triticum aestivum L. ssp. aestivum) lines of different origin using multiplex PCR
Publication -
Fatal intoxication with U-47700 in combination with other NPS (N-ethylhexedrone, adinazolam, 4-CIC, 4-CMC) confirmed by identification and quantification in autopsy specimens and evidences
Publication -
Treatment of landfill leachate in a constructed free water surface wetland system over a decade – Identification of disturbance in process behaviour and removal of eutrophying substances and organic material
PublicationAn 8 ha free water surface wetland system in Örebro, Sweden, which has sediment traps followed by 10 ponds for treatment of landfill leachate in the methanogenic stage, was studied from 2003 to 2012. The wetland was irregularly loaded and the leachate characteristics showed high temporal and spatial variability, so Multivariate Statistical Process Control was chosen as the diagnostic tool for detecting anomalies prior to assessing...
-
Broken Rotor Symptons in the Sensorless Control of Induction Machine
PublicationInverter fed sensorless controlled variable speed drives with induction machine are widely used in the industry applications, also in wind power generation and electric vehicles. On-line self diagnostic systems implementation is needed for early stage fault detection and avoiding a critical fault. Diagnostic algorithms in modern DSP-based controllers can operate simultaneously with control system functions. In the closed-loop controlled...
-
Genome-Wide Identification of Dickeya solani Transcriptional Units Up-Regulated in Response to Plant Tissues From a Crop-Host Solanum tuberosum and a Weed-Host Solanum dulcamara
Publication -
Differential and Overlapping Effects of 20,23(OH)2D3 and 1,25(OH)2D3 on Gene Expression in Human Epidermal Keratinocytes: Identification of AhR as an Alternative Receptor for 20,23(OH)2D3
Publication -
Identification of X-DING-CD4, a new member of human DING protein family that is secreted by HIV-1 resistant CD4+ T cells and has anti-viral activity
Publication -
State and control system variables sensitivity to rotor asymmetry in the induction motor drive
PublicationThe aim of this paper is to undertake analysis and comparison of the closed-loop and sensorless control systems sensitivity to the broken rotor for diagnostic purposes. For the same vector control system induction motor drive analysis concerning operation with the asymmetric motor, broken rotor fault handling and operation were investigated. Reliability, range of stable operation, fault symptoms and application of diagnosis methods...
-
Identyfikacja i izolacja genu kodującego zaadaptowaną do zimna β-galaktozydazę Paracoccus sp. = Identification and izolation of the gene encoding cold-active β-galactosidase from paracoccus sp.
PublicationZaprezentowane badania były prowadzone u eehi wyizolowania ze środo¬wiska organizmu psychrofilnego, zdolnego do hydrolizy laktozy w niskiej tempe¬raturze, oraz zidentyfikowania genu kodującego (i-galaktozydazę zaadaptowaną do zimna.Poszukiwan gen został w izolowany z psychrofilnego szczepu autarkicz¬nego Paracoccus sp. 321). Na podstawie sekwencji nukleotydowej genu kodują¬cego fS-galaktozdaze ustalono skład aminokwasów),...
-
Resonance problems in UHV transmission lines
PublicationThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
Service-based Resilience via Shared Protection in Mission-critical Embedded Networks
PublicationMission-critical networks, which for example can be found in autonomous cars and avionics, are complex systems with a multitude of interconnected embedded nodes and various service demands. Their resilience against failures and attacks is a crucial property and has to be already considered in their design phase. In this paper, we introduce a novel approach for optimal joint service allocation and routing, leveraging virtualized...
-
Convenient identification of desulfoglucosinolates on the basis of mass spectra obtained during liquid chromatography-diode array-electrospray ionisation mass spectrometry analysis: Method verification for sprouts of different Brassicaceae species extracts
PublicationOver the past decade, glucosinolates (GLs) present in different tissues of Brassicaceae and their breakdown products, especially isothiocyanates formed after myrosinase catalyzed hydrolysis, have been regarded as not only environment friendly biopesticides for controlling soilborne pathogens, but most importantly as promising anticarcinogenic compounds. For these reasons, the identification and quantitative determination of the...
-
IDENTIFICATION OF DAMAGES OF TRIBOLOGICAL ASSOCIATIONS IN CRANKSHAFT AND PISTON SYSTEMS OF TWO-STROKE INTERNAL COMBUSTION ENGINES USED AS MAIN PROPULSION IN SEA-GOING VESSELS AND PROPOSAL OF PROBABILISTIC DESCRIPTION OF LOADS AS CAUSES OF THESE DAMAGES
PublicationThe article discusses damages of essential tribological associations in crankshaft and piston systems of large power two-stroke engines used as main engines, which take place during transport tasks performed by those ships. Difficulties are named which make preventing those damages impossible, despite the fact that the technical state of engines of this type is identified with the aid of complex diagnostic systems making use of...
-
Comments on Identification and Determination of Volatile Chloroorganic Compounds in Crude Oil at Trace Level = Komentarz na temat identyfikowania i oznaczania śladowych ilości lotnych związków chloroorganicznych w ropie naftowej
PublicationW pracy przedstawiono możliwości i ograniczenia w stosowaniu techniki GC-ECD i GC-MS do identyfikacji i oznaczania śladowych stężeń związków chloroorganicznych w destylatach z ropy naftowej (frakcjach wrzących do 200oC). Przedyskutowano także procedury rutynowo stosowane w rafineriach do oznaczania zawartości chloru organicznego. Należą do nich metodyki oparte na spalaniu próbki i oznaczaniu wybranych produktów mineralizacji za...
-
Identyfikacja parametrów zastępczego schematu elektrycznego krwiobiegu nerki na podstawie niepełnych danych pomiarowych : The parameters identification of the equivalent electric circuit of the kidney blood circulation basis on incomplete measuring date
PublicationW referacie przedstawiono metodę identyfikacji parametrów elektrycznego schematu zastępczego odwzorowującego przepływ krwi przez nerkę. Napięcie potraktowano jako sygnał wejściowy, któremu w hemodynamice odpowiada ciśnienie, natomiast prąd jako sygnał wyjściowy, któremu odpowiada przepływ krwi. Przebieg napięcia aproksymowano funkcją sklejaną w celu uproszczenia procedury pomiarowej i ograniczenia fluktuacji związanych z przebiegiem...
-
Identification of novel psychoactive substances 25B-NBOMe and 4-CMC in biological material using HPLC-Q-TOF-MS and their quantification in blood using UPLC–MS/MS in case of severe intoxications
PublicationThis paper describes cases of poisoning caused by new psychoactive substances such as: 25BNBOMe (2-(4-bromo-2,5-dimethoxyphenyl)-N-[(2-methoxyphenyl)methyl]ethanamine) and 4-CMC (1-(4-chlorophenyl)-2-(methylamino)-1-propanone). The analytical procedure includes rapid and selective method for the extraction and determination of 4-CMC and 25B-NBOMe in blood samples using UPLC–MS/MS technique. To the best of our knowledge,this is...
-
Residual current devices in electric vehicles charging installations
PublicationThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Identification attempts of toluene sources in post-flood sediment samples from the Odra river (flood 1997). Identyfikacja źródeł toluenu w próbkach osadów popowodziowych pobranych z rzeki Odry (powódź 1997).
PublicationPrzedstawiono badania mające na celu oznaczanie zawartości toluenu w próbkach osadów dennych i w próbkach mikrobiologicznych. W badaniach wykorzystano zestaw do jednoczesnego wymywania i wychwytywania analitów na stałym sorbencie (Purge and Trap). Oznaczenia końcowe wykonano z wykorzystaniem techniki chromatografii gazowej połączonej ze spektrometrem mas.
-
Iterative‐recursive estimation of parameters of regression models with resistance to outliers on practical examples
PublicationHere, identification of processes and systems in the sense of the least sum of absolute values is taken into consideration. The respective absolute value estimators are recognised as exceptionally insensitive to large measurement faults or other defects in the processed data, whereas the classical least squares procedure appears to be completely impractical for processing the data contaminated with such parasitic distortions. Since...
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublicationEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Synthesis of 11,12-dihydro benzo[c]phenanthridines via a Pd-catalyzed unusual construction of isocoumarin ring/FeCl3-mediated intramolecular arene-allyl cyclization: First identification of a benzo[c]phenanthridine based PDE4 inhibitor
Publication -
Portable raman spectrometer for maritime security applications
PublicationThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is widely used for fast identification of various chemicals. Continuous progress in the field of photonics has resulted in commercial availability of low-power compact Raman spectrometers which can be integrated into portable systems....
-
Residual Current Devices: Selection, Operation, and Testing
PublicationIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Szybkie uziemniki do ograniczania skutków zwarć łukowych w okrętowych rozdzielnicach SN
PublicationW artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu gazu ziemnego w stanie ciekłym. Na podstawie parametrów prądnic i silników odbiorników zasilanych z rozdzielnicy głównej obliczono prądy...
-
Conditions for increasing the recognition of degradation in thermal-flow diagnostics, taking into account environmental legal aspects
PublicationThe ever-increasing demand for electricity and the need for conventional sources to cooperate with renewable ones generates the need to increase the efficiency and safety of the generation sources. Therefore, it is necessary to find a way to operate existing facilities more efficiently with full detection of emerging faults. These are the requirements of Polish, European and International law, which demands that energy facilities...
-
Demonstrator testera wbudowanego BIST dla układów w pełni różnicowych
PublicationPrzedstawiono demonstrator testera wbudowanego, przeznaczony do pracy na stanowisku dydaktycznym w laboratorium z przedmiotu Zaawansowane Metody Pomiarowe i Diagnostyczne. Na stanowisku studenci zapoznają się z technologią BIST (ang. Built-In Self-Test), która jest przykładem wdrożenia strategii projektowania dla testowania.
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublicationThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Optimal retrofit strategy using viscous dampers between adjacent RC and SMRFs prone to earthquake‑induced pounding
PublicationNowadays, retrofitting-damaged buildings is an important challenge for engineers. Finding the optimal placement of Viscous Dampers (VDs) between adjacent structures prone to earthquake-induced pounding can help designers to implement VDs with optimizing the cost of construction and achieving higher performance levels for both structures. In this research, the optimal placement of linear and nonlinear VDs between the 3-story, 5-story,...
-
An idea of an approach to self-testing of mixed signal systems based on a quadratic function stimulation
PublicationA new approach to self-testing of the analog parts of mixed-signal electronic systems controlled by microcontrollers equipped with an ADC and a DAC is presented. It is based on a BIST and a new fault diagnosis method. A novelty is the use of the DAC as a component of the BIST, allowing to generate a stimulating signal with a quadratic function shape. It contributes to a better extraction of information about the state of the circuit...
-
Wybrane metody przydatne w analizie niezawodności i bezpieczeństwa funkcjonalnego systemów technicznych.
PublicationPrzedstawiono wybrane metody przydatne w analizie niezawodności i bezpieczeństwa funkcjonalnego systemów technicznych takie jak: metoda FMECA (failure mode, effect and criticality analysis, FTA (fault tree analysis, RBD (reliability block diagram) RCM (reliability centered maintenance, LCC (life cycle cost) i PMO (preventive maintenance optimising.
-
Diagnostics of thermal processes in antenna systems of broadcast stations
PublicationDiagnostics is an important element associated with the operation of a radio antenna systems, allowing earlier detection of potential damage. Thermography is one of the diagnostic tools, which allows for non-invasive assessment of technical condition. It brings together both financial savings associated with the removal of the damage and the potential effects caused by it. The article presents an example of using a thermal imaging...
-
Residual current devices in installations with PV energy sources
PublicationThe paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of...
-
Samotestowanie toru analogowego ze wzmacniaczem w pełni różnicowym w elektronicznych systemach wbudowanych sterowanych mikrokontrole-rami
PublicationPrzedstawiono nową metodę samotestowania toru analogowego opartego na wzmacniaczu w pełni różnicowym w elektronicznych systemach wbu-dowanych sterowanych mikrokontrolerami. Bazuje ona na nowej metodzie diagnostycznej opartej na przekształceniu transformującym próbki odpo-wiedzi czasowej badanej części analogowej na pobudzenie "ujemnym" impulsem prostokątnym na wejściu Vocm na krzywe identyfikacyjne w przestrzeni pomiarowej. Metoda...
-
Refinement of the Hardening Soil model within the small strain range
PublicationThe popularity of the elasto-plastic Hardening Soil (HS) model is based on simple parameter identification from standard testing and empirical formulas. The HS model is implemented in many commercial FE codes designed to analyse geotechnical problems. In its basic version, the stress–strain behaviour within the elastic range is subject to the hypoelastic power law, which assures the barotropy of the elastic stiffness. However,...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Analiza przepływu gazu w kanałowych reduktorach ciśnienia podczas zwarć łukowych w rozdzielnicach SN
PublicationW artykule przedstawiono metodę obliczania ciśnienia i temperatury gazów podczas zwarcia łukowego wewnątrz przedziału wyłącznika rozdzielnicy średniego napięcia z wykorzystaniem modelu termodynamicznego procesów towarzyszących zwarciom łukowym wewnątrz rozdzielnic z izolacją powietrzną. Następnie, w oparciu o mechanikę płynów lepkich, przedstawiono metodę obliczania rozkładu prędkości i ciśnienia gazu w kanałowych reduktorach ciśnienia...
-
General Provisioning Strategy for Local Specialized Cloud Computing Environments
PublicationThe well-known management strategies in cloud computing based on SLA requirements are considered. A deterministic parallel provisioning algorithm has been prepared and used to show its behavior for three different requirements: load balancing, consolidation, and fault tolerance. The impact of these strategies on the total execution time of different sets of services is analyzed for randomly chosen sets of data. This makes it possible...
-
Locating and Identifying Ferromagnetic Objects
PublicationThe new non-iterative method of determining the dipole moment and location is presented in this paper. The algorithm of an object's localization and identification was achieved by using numerical calculations and approximation method. The arbitrary shapes of an object were assumed in the identification algorithm - axially symmetric spheroid (a prolate and an oblate). Several examples of localization and identification of an object's...
-
Locating and Identifying Ferromagnetic Objects
PublicationThe new non-iterative method of determining the dipole moment and location is presented in this paper. The algorithm of an object's localization and identification was achieved by using numerical calculations and approximation method. The arbitrary shapes of an object were assumed in the identification algorithm - axially symmetric spheroid (a prolate and an oblate). Several examples of localization and identification of an object's...
-
Skutki zwarć łukowych w średnionapięciowych rozdzielnicach okrętowych z izolacją powietrzną
PublicationW artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu kontenerów, w tym 600 kontenerów chłodzonych. Na podstawie parametrów prądnic i silników, odbiorników zasilanych z rozdzielnicy głównej...
-
Machine learning-based prediction of seismic limit-state capacity of steel moment-resisting frames considering soil-structure interaction
PublicationRegarding the unpredictable and complex nature of seismic excitations, there is a need for vulnerability assessment of newly constructed or existing structures. Predicting the seismic limit-state capacity of steel Moment-Resisting Frames (MRFs) can help designers to have a preliminary estimation and improve their views about the seismic performance of the designed structure. This study improved data-driven decision techniques in...
-
Performance analysis of power swing blocking feature in ABB 670 series impedance relays
PublicationThis paper presents test results of a distance protection’s PSD power swing detection feature in ABB 670 series relays. A RED670 relay was tested, which is part of the hydroelectric set protection in Żarnowiec Pumped Storage Plant. The power swing blocking feature’s performance was analysed on the basis of the results of object tests made with an Omicron digital tester. Also presented are simulation results that illustrate the...
-
SELECTION OF DIAGNOSTIC FUNCTIONS IN A WHEELED TRACTOR
PublicationIn a classical approach to damage diagnosis, the technical condition of an analyzed machine is identified based on the measured symptoms, such as performance, thermal state or vibration parameters. In wheeled tractor the fundamental importance has monitoring and diagnostics during exploitation concerning technical inspection and fault element localizations. The main functions of a diagnostic system are: monitoring tractor components...
-
Mid-infrared spectroscopy for characterization of Baltic amber (succinite)
PublicationNatural Baltic amber (succinite) is the most appreciated fossil resin of the rich cultural traditions dating back to prehistoric times. Its unequivocal identification is extremely important in many branches of science and trades including archeology, paleontology, chemistry and finally mineralogical and gemological societies. Current methods of modification of natural succinite are more and more sophisticated making the identification...
-
Enhancing seismic performance of rigid and semi-rigid connections equipped with SMA bolts incorporating nonlinear soil-structure interaction
PublicationNowadays, using smart connections can improve the performance of buildings with some recentering features that are from the superelastic behavior of Shape Memory Alloys (SMAs). It seems that there is different rigidity between the designed connection and the real one in Steel Moment-Resisting Frames (SMRFs), which can be considered as a problematic issue due to the importance of connections in seismic performance assessment. This...
-
Redukcja czasu analizy MZP przez ograniczenie rozmiaru rozwiązania
PublicationAnaliza drzew niezdatności jest uznaną metodą analizy bezpieczeństwa systemów. Notacja ECSDM pozwala definiować zależności czasowe między zdarzeniami drzewa oraz przeanalizować je w celu określenia zależności pomiędzy zdarzeniami z Minimalnych Zbiorów Przyczyn (MZP). Dzięki wprowadzeniu klasyfikacji zdarzeń z MZP można wyodrębnić zależności czasowe istotne dla zapobiegania wywoływania hazardu przez konkretny MZP. Pozostałe zależności...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublicationThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.