Filters
total: 384
filtered: 266
-
Catalog
Chosen catalog filters
Search results for: IMPLANTY
-
Comprehensive Evaluation of the Biological Properties of Surface-Modified Titanium Alloy Implants
PublicationAn increasing interest in the fabrication of implants made of titanium and its alloys results from their capacity to be integrated into the bone system. This integration is facilitated by different modifications of the implant surface. Here, we assessed the bioactivity of amorphous titania nanoporous and nanotubular coatings (TNTs), produced by electrochemical oxidation of Ti6Al4V orthopedic implants’ surface. The chemical composition...
-
The bahaviour of selected silver coated body implants in presence of various bacteria
PublicationThe article deals with implants covered with silver nanoparticles and its influence on bacteria adhesion.
-
Materiały stosowane do wytwarzania implantów kości
PublicationMateriały stosowane do wytwarzania implantów kostnych muszą być biokompatybilne, nietoksyczne, bioaktywne oraz wykazywać odpowiednie właściwości mechaniczne, takie jak wytrzymałość na ściskanie, na zginanie oraz sztywność i twardość. Gama stosowanych materiałów jest bardzo szeroka, obejmuje metale, polimery, ceramikę oraz ich kompozyty. Każdy z tych materiałów ma swoje mocne i słabe strony. Praca stanowi przegląd materiałów stosowanych...
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublicationThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
Dynamics of mechanical model of implant-tissue system in ventral hernia repair
PublicationThe paper deals with a finite element modelling of implants in the problem of ventral hernia repair. The synthetic mesh implanted in the abdomen during surgery is here modelled as a membrane structure. Thesystem undergoes the internal abdominal pressure that occurs during the postoperative cough, the load identified in the literature as the main cause of the connection failure and hernia recurrence. The model can be used to estimate...
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublicationAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
IMPLANT USED IN HERNIA REPAIR UNDER PHYSIOLOGICAL MOVEMENTS OF HUMAN ABDOMEN
PublicationThe study deals with the mechanical behaviour of implant used in repair of abdominal hernia. The influence of orientation of the orthotropic implants in different areas of abdominal wall is studied.
-
Mathematical approach to design 3D scaffolds for the 3D printable bone implant
PublicationThis work demonstrates that an artificial scaffold structure can be designed to exhibit mechanical properties close to the ones of real bone tissue, thus highly reducing the stress-shielding phenomenon. In this study the scan of lumbar vertebra fragment was reproduced to create a numerical 3D model (this model was called the reference bone sample). New nine 3D scaffold samples were designed and their numerical models were created....
-
Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair
PublicationEven though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...
-
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Electro-optical system for the automated selection of dental implants according to their colour matching
Publication -
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Influence of Surface Modification of Titanium and Its Alloys for Medical Implants on Their Corrosion Behavior
PublicationTitanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment,...
-
Constitutive Modelling of Knitted Abdominal Implants in Numerical Simulations of Repaired Hernia Mechanics
PublicationThe paper presents a numerical approach to describe mechanical behavior of anisotropic textile material, which is a selected abdominal prosthesis. Two constitutive nonlinear concepts are compared. In the first one the material is considered composed from two families of threads (dense net model) and in the second one the material is homogeneous but anisotropic (as proposed by Gassel, Ogden, Holzapfel). Parameters of both models...
-
Mathematical study of a tissue-implant connection in a ventral herniarepair in a context of the system's parameters
PublicationW pracy przedstawiono problem operowania przepuklin brzusznych u ludzi. Zaproponowano jednowymiarowy model układu powieź-implant. Na podstawie analizy wrażliwości zidentyfikowano najważniejsze parametry problemu.
-
Identification of the damage mechanism in orthopaedic implant. Case study including the biomechanical analysis
Publication -
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublicationThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
-
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublicationIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
PODATNOŚĆ IMPLANTÓW KARDIOLOGICZNYCH NA BIODEGRADACJĘ – PRZEGLĄD LITERATURY
PublicationDo implantów kardiologicznych należą sztuczne zastawki serca, naczynia krwionośne oraz stenty naczyniowe i stymulatory serca. Wszczepy te umieszcza się w miejscu nieprawidłowo działającego elementu w celu poprawy stanu zdrowia i jakości życia pacjenta. Prawidłowe funkcjonowanie implantów może zostać zaburzone przez biodegradację, która nie jest efektem jednego procesu, lecz skutkiem synergicznego działania wielu czynników natury...
-
Obiektywna metoda wyznaczania skuteczności systemów implantów ślimakowych
PublicationPrzedmiotem pracy było opracowanie nowej metody wyznaczania skuteczności systemów implantów ślimakowych opartej o komputerowe symulacje słyszenia elektrycznego.
-
Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study
PublicationPrimary stability of cementless implants is crucial for the surgical success and long–term stability. However, primary stability is difficult to quantify in vivo and the biomechanical phenomena occurring during the press–fit insertion of an acetabular cup (AC) implant are still poorly understood. The aim of this study is to investigate the influence of the cortical and trabecular bone Young's moduli Ec and Et, the interference...
-
Surgical implant used in ventral hernia repair subjected to physiological pressure - computer simulation
PublicationW streszczeniu przedstawiono matemayczny model implantu wszczepionego pacjentowi podczas laparoskopowej naprawy przepukliny brzusznej. Wykonano go z użyciem metody elementów skończonych. Przyjęto ortotropowy model materiałowy implantu.
-
Assessment of the usefulness of bacterial cellulose produced by Gluconacetobacter xylinus E25 as a new biological implant
PublicationBionanocellulose (BNC) is a clear polymer produced by the bacterium Gluconacetobacter xylinus. In our current study, “Research on the use of bacterial nanocellulose (BNC) in regenerative medicine as a function of the biological implants in cardiac and vascular surgery”, we carried out material analysis, biochemical analysis, in vitro tests and in vivo animal model testing. In stage 1 of the project, we carried out physical and...
-
Rozwój bioaktywnych implantów porowatych na osnowie stopów tytanu
PublicationGłównym przedmiotem pracy są złożone zagadnienia materiałowe wynikajace ze specyfiki zastosowań implantów wytworzonych z tytanu i jego stopów, szczególnie w zakresie bioaktywności i stabilności długoczasowej implantów tkanki kostnej w obszarach przenoszących znaczne obciążenia. Dokonano krytycznej analizy obecnego stanu wiedzy w tym zakresie i przedstawiono wyniki prac własnych prowadzonych prowadzonych na Politechnice Gdańskiej,...
-
Biological effect of hydrothermally synthesized silica nanoparticles within crystalline hydroxyapatite coatings for titanium implants
Publication -
Composites of polylactide and nano-hydroxyapatite created by cryomilling and warm isostatic pressing for bone implants applications
Publication -
Development and biological evaluation of Ti6Al7Nb scaffold implants coated with gentamycin-saturated bacterial cellulose biomaterial
Publication -
Studies on Silver Ions Releasing Processes and Mechanical Properties of Surface-Modified Titanium Alloy Implants
PublicationDispersed silver nanoparticles (AgNPs) on the surface of titanium alloy (Ti6Al4V) and titanium alloy modified by titania nanotube layer (Ti6Al4V/TNT) substrates were produced by the chemical vapor deposition method (CVD) using a novel precursor of the formula [Ag5(O2CC2F5)5(H2O)3]. The structure and volatile properties of this compound were determined using single crystal X-ray diffractometry, variable temperature IR spectrophotometry...
-
Modelowanie i badania doświadczalne implantów stosowanych w operacjach laparoskopowych
PublicationW pracy przedstawiono problemy modelowania implantów wszczepianych do powięzi w czasie operacji przepuklin brzusznych. Zastosowano metodę elementów skończonych w implementacj komputerowej systemu MSC.Marc.Wyniki symulacji komputerowej porównano z wynikami badań doświadczalnych implantu połączonego z powięzia zszywkami, które przeprowadzono w specjalnej, szczelnej komorze. Badany układ implant-powięź poddany był działaniu impulsowego...
-
Innowacyjna powłoka poprawiająca własności mechaniczne oraz biokompatybilne stopów tytanu Ti6Al4V i Ti13Zr13Nb przeznaczonych na implanty wewnetrzne
PublicationOstatnie badania nad materiałami tytanowymi przeznaczonymi na implanty wewnętrzne pokazują iż dotychczas uznawany za bezinwazyjny tytan odkłada się w organizmie. Nie wiadomo jeszcze jakie konsekwencje są tego procesu dla organizmu żywego. W artykule przedstawiono idee wytworzenia nowej, biokompatybilnej powłoki, która ma na celu zminimalizowanie przenikania jonów metalu do organizmu ludzkiego oraz ułatwienie porastania implantu...
-
Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation
Publicationrelation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients’ life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical...
-
„…I głosu, którym mówił, przypomnieć nie mogę”. Dzieło sztuki jako implant pamięci
PublicationPodjęcie tematu pamięci odziedziczonej, pamięci zastępczej – co dzieje się z pamięcią, gdy świadków wydarzeń nie ma już wśród nas – jest obecnie szczególnie ważne dla pamięci o wydarzeniach II wojny, w szczególności w odniesieniu do pamięci o Zagładzie. Koncepcja „implantów pamięci”, rozumianych jako „wtórnie i post factum wykreowane: budowle, zapisy, obrazy czy filmy, a także treści wiedzy, które mają uzupełnić braki pamięci,...
-
Telemetria odpowiedzi neuronalnych jako metoda wspomagająca dobór parametrów stymulacji przez implant ślimakowy
PublicationDzięki pomiarom odpowiedzi neuronalnych i możliwości wyznaczenia na tej podstawie tendencji rozkładu progów stymulacji można lepiej zaprogramować procesor mowy. Jest to niezwykle cenne zwłaszcza u pacjentów nie współpracujących podczas badań (na przykład u małych dzieci). W przypadku takich pacjentów tradycyjne, psychoakustyczne metody doboru parametrów stymulacji przez implant często zawodzą. Natomiast gdy audiolog dysponuje prawdopodobną...
-
IN VIVO DEGRADATION OF BIOMATERIALS
PublicationThe material designed to be introduced into the human tissue should be biocompatible and biofunctional. Unless it is so, the body may respond to the implant in different ways. An inflammation reaction may appear such as: parting of items of the implant surface resulting from fraction or pressure. The condition of the surface has an important influence on the usefulness of the implant. The required values depend on the implant function...
-
Numerical Model of the Aortic Valve Implanted Within Real Human Aorta
PublicationCardiovascular system diseases are the main cause of deaths in developed and developing countries. The main reasons are myocardial infarction, heart failure, stroke and valvular diseases. These are caused mainly by arteriosclerosis. The valvular diseases involve a significant burden for the health care system and their frequency is rising with the patient age. This work describes the tools and numerical models appropriate for modeling...
-
The research of glass-ceramics implants used for bone pitches to examine bacteria adhesion occuring in human body
PublicationThe paper deals with the research concerning the bacteria adhesion on bioactive glass - ceramics materials
-
Ultrafine-Grained Ti-31Mo-Type Composites with HA and Ag, Ta2O5 or CeO2 Addition for Implant Applications
Publication -
Complex Corrosion Properties of AISI 316L Steel Prepared by 3D Printing Technology for Possible Implant Applications
Publication -
A FEM membrane model of human fascia-synthetic implant system in a case of a stiff ventral hernia orifice
PublicationPraca prezdstawia model matematyczny układu tkanka ludzka - implant syntetyczny w postaci tzw. siatki w leczeniu przepuklin brzusznych. Implant jest tu moelowany jako struktura membranowa. Ocena wpływu danych materiałowych oraz wstępnego napięcia na zachowanie pracującej membrany po implantacji została przedstawiona na podstawie analizy wrażliwości. Pracę podsumowują pewne wskazówki dla chirurgów implantujących siatki.
-
Charakteryzacja warstw tlenkowych na stali 316L dla potzeb implantów biomedycznych
PublicationW pracy sprawdzony został wpływ warstw ochronnych na poprawę odporności korozyjnej stali 316L. Jako warstwy ochronne zastosowano materiał tlenku cyrkonu stabilizowanego itrem.
-
Możliwości modelowania rozkładu naprężeń i odkształceń w endoprotezie stawu biodrowego w układzie implant - kość z uwzględnieniem własności materiałowych = Possibility of stress and strain modelling in total hip replacement in implant-bone system including material properties
PublicationW pracy przedstawiono możliwości wykorzystania numerycznych technik komputerowych do modelowania rozkładu naprężeń i odkształceń w endoprotezie stawu biodrowego w układzie implant-kość z uwzględnieniem własności materiałowych elementów endoprotezy. Przedstawiono komputerowe modele służące do analizy naprężeń i odkształceń w endoprotezie wykonane przy wykorzystaniu metody elementów skończonych. Metody modelowania naprężeń i odkształceń...
-
Problematyka implantacji protez piersiowych - przegląd literatury
PublicationOperacje związane z wykorzystaniem implantów piersi są jednymi z najczęściej przeprowadzanych zabiegów chirurgii plastycznej, dlatego istotne jest, aby zminimalizować ryzyko powikłań. Do najczęściej występujących zalicza się: obrzęk, wysięk, krwiaki, problemy z gojeniem ran oraz infekcje. Zakłada się, że infekcja jest głównym czynnikiem prowadzącym do degradacji implantu. Agresywne środowisko gospodarza, ciągłe zmiany pH i temperatury...
-
Ocena możliwości zastosowania obróbki laserowej i implantacji jonowej stopów metali na implant stawu kolanowego
PublicationZagadnieniem podjętym w niniejszym referacie jest zmodyfikowanie warstwy wierzchniej stopu tytanu Ti6Al4V przeznaczonego na implanty. Autor opisuje metody modyfikacji powierzchni w wyniki nakładania warstwy węglowej metodą PA CVD (ang. Plasma Assisted Chemical Vapour Deposition) oraz warstwy hydroksyapatytu metodą zol-żel i elektrochemiczną. Badania zostały przeprowadzone w laboratoriach Zakładu Biomateriałów, Katedry Inżynierii...
-
The influence of plasma-sprayed coatings on surface properties and corrosion resistance of 316L stainless steel for possible implant application
Publication -
Nanotechnologie w implantologii – osiągnięcia i wyzwania
PublicationAktualnie nanotechnologia jest jedną z najszybciej rozwijających się gałęzi przemysłu, w tym również w zakresie medycyny i implantologii. Osiągnięcia nanotechnologii wykorzystuje się w obrazowaniu, diagnostyce, leczeniu chorób nowotworowych i bólu, lecz również szeroko w obszarze projektowania i wytwarzania implantów, w tym głownie modyfikacji powierzchni materiałów, które mają za zadanie chwilowo lub permanentnie zastąpić funkcję...
-
Cuprous Oxide Thin Films Implanted with Chromium Ions - Optical and Physical Properties Studies
Publication -
Mechanics of mesh implanted into abdominal wall under repetitive load. Experimental and numerical study
PublicationThere are a number of papers discussing medical and mechanical aspects of ventral hernia management. Despite intensive work on the problem understanding, recurrences of the sickness still happen too often. For that reason new aspects of the problem must be considered. In this paper, a change in the abdominal implant’s stiffness is discussed, which is caused by cyclic loading. Such loading influence abdominal implant e.g. while...
-
Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair
PublicationVentral hernia is a common medical problem. Statistically there are around 10% recurrences of the sickness. The authors' former investigation proved edges of the hernia orifice displacements to be one of the factors causing recurrence. Thus, experimental investigation of the abdomen surface deformation due to some normal activities of people is studied.The extreme strains, their localization and directions are identified. The acquired...
-
pH-dependent composite coatings for controlled drug delivery system - Review
PublicationNowadays in case of long-term implants, the most common postoperative complications are bacterial infections, which in consequence may provoke loos- ening of the implants in the primary phase of stabilization. Bacterial infections are currently the most frequent cause of revision surgery of the implants such as hip joint endoprosthesis, knee joint endoprosthesis and dental implants. In order to provide the local and long-term antibacterial...
-
Implant system for treatment of the orbital floor defects of blowout fractures in the maxillofacial region using polypropylene yarn and bioactive bone cement
PublicationFractures in the craniofacial region are a serious problem in terms of treatment. The most reasonable solution is the use of individual implants dedicated to a specific patient. The aim of this study was to develop the implant system specifically for treatment of the orbital floor defects of blowout fractures of maxillofacial region, using polypropylene yarn and bone cement. Three types of bone cement were used to fix the polypropylene...