Filters
total: 1693
-
Catalog
- Publications 1124 available results
- Journals 11 available results
- People 21 available results
- Inventions 6 available results
- Projects 12 available results
- Laboratories 1 available results
- Research Teams 3 available results
- e-Learning Courses 19 available results
- Events 2 available results
- Open Research Data 494 available results
displaying 1000 best results Help
Search results for: ELEKTRODY MEMBRANOWE
-
Ion-selective electrodes based on p-tert-butyl-homooxacalixarene di(ethyl) amides
PublicationPochodne dietyloamidowe p-tert-butylodihomooksakaliks[4]arenu (1), p-tert-butyloheksahomotrioksakaliks[3]arenu (2) oraz p-tert-butylokaliks[4]arenu (3) były wykorzystane jako materiał aktywny w membranach elektrod jonoselektywnych w celu sprawdzenia detekcji kationów różnych rodzajów (Na+, K+, Cs+, Mg2+, Ca2+, Mn2+, Cu2+, Zn2+, Cd2+, Pb2+ oraz kation tetrametyloammoniowy). Wyznaczono charakterystyki elektrod oraz współczynniki...
-
Monika Wilamowska-Zawłocka dr hab. inż.
PeopleDr Monika WILAMOWSKA-ZAWŁOCKA obtained her PhD in Chemistry in 2011 at Faculty of Chemistry, Gdańsk University of Technology. She then was a post-doctoral fellow at Technische Universität Darmstadt, Germany. Since 2013 she has worked at Gdańsk University of Technology, since 2019 as an Associate Professor. Her research interests include composite materials for energy storage devices, especially for lithium-ion and sodium-ion batteries,...
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublicationIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
-
Kallikrein-related peptidase 14 activates zymogens of membrane type matrix metalloproteinases (MT-MMPs) - a CleavEx library-based analysis
Publication -
Optimization of a microplate reader method for the analysis of changes in mitochondrial membrane potential in Chlamydomonas reinhardtii cells using the fluorochrome JC-1
Publication -
How do sterols determine the antufungal activitiy of amphotericin B? Free energy of binding between the drug and its membrane targets.
PublicationAmphotericin B (AmB) is a well-known polyene antibiotic used to treat systemic fungal infections. It is commonly accepted that the presence of sterols in the membrane is essential for the AmB biological activity, that is, for the formation of transmembrane ion channels. The selective toxicity of AmB for fungal cells is attributed to the fact that it is more potent against fungal cell membranes containing ergosterol than against...
-
Arginine-, d-arginine-vasopressin, and their inverso analogues in micellar and liposomic models of cell membrane: CD, NMR, and molecular dynamics studies
Publication -
An integral-differential method for impedance determination of the hydrogen oxidation process in the presence of carbon monoxide in the proton exchange membrane fuel cell
PublicationThe impedance of a proton exchange membrane fuel cell powered by hydrogen contaminated with carbon monoxide, ranging from 150 to 300 ppb, is measured and discussed. The tested range of CO concentration complied with the fuel standard specified in the ISO standards. Studies of influence of CO contamination on operation of PEMFC are crucial for further development and commercialization of fuel cells for automotive applications. Based...
-
Ultrasound-Assisted Solvent Extraction of a Porous Membrane Packed Sample for the Determination of Tobacco-Specific Nitrosamines in the Replacement Liquids for E-Cigarettes
PublicationThe content of tobacco-specific nitrosamines (TSNAs) possessing carcinogenic properties has been an important area of research since replacement liquids were introduced for e-cigarettes. A method for determining N′-nitrosonornicotine (NNN), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N′-nitrosoanatabine (NAT), and N′-nitrosoanabasine (NAB) in replacement liquids for electronic cigarettes was developed using liquid chromatography–tandem...
-
Lower Rim Substituted p-tert-Butyl Calix[4]arenes(V). Synthesis of New 5,11,17,22-tetrakis-p-tert-Butyl-25-27-bis(dialkoxyphosphorylmethoxy)calix[4] arenes and Cation Complexation Studies in Ion Selective Membrane Electrodes.
PublicationZaprezentowano syntezę i właściwości trzech nowych związków (2-4), bis podstawionych na dolnym obrzeżu grupami z resztą fosforylową. Związki te były badane jako jonofory w membranowych elektrodach jonoselektywnych (ISE) wykazując selektywność na kationy Rb+,K+ oraz duży i płaski kation guanidyniowyG+). Badano korelację pomiędzy stereo-strukturą związków a ich selektywnością w ISE. Stałe trwałości kompleksów z kationami metali...
-
Modyfikacja i optymalizacja konstrukcji elektrochemicznych czujników gazów toksycznych
PublicationW pracy przedstawiono wyniki badań mających na celu opracowanie konstrukcji i przebadanie właściwości elektrochemicznych czujników gazów. Badania dotyczyły amperometrycznego czujnika ditlenku siarki oraz czujnika elektrokatalitycznego wykorzystanego do pomiaru stężenia gazów toksycznych. Badany w pracy prototyp czujnika posiadał elektrodę pomiarową otrzymaną w wyniku chemicznego wytrącania złota w membranie nafionowej. Zbadano...
-
O-substituted tetrahydroxamate derivatives of p-tert-butylcalix[4]arene as receptors for transition and heavy metal cations
PublicationTetrasubstituted O-hydroxamate derivatives of p-tert-butylcalix[4]arene were applied as active materials in ion-selective membrane electrodes and were tested towards Pb-selectivity. The electrodes gave near-Nernstian characteristics for Pb2+ cations. The selectivity coefficients were determined. The influence of plasticizer on the electrode behaviour was studied. The dependence of the chemical structure on selectivity coefficients...
-
Lower rim substituted tert-Butylcalix[4]arenes. Part 13. Interaction of calix-hydroxamates with Fe(III) and Pb(II); studies in ion-selective membrane electrodes (ISE)
PublicationPrzedmiotem pracy są badania oddziaływań pomiędzy trzema wybranymi hydroksamowymi pochodnymi t-butylo-kaliks[4]arenu i jonami metali z wykorzystaniem membranowych elektrod jonoselektywnych (ISE). Elektrody zawierające jako materiał aktywny wymienione związki jonoforowe charakteryzują się nernstowskim nachyleniem i szerokim zakresem liniowości na jony Pb(II), a także dobrą selektywnością na jony Pb(II)w stosunku do jonów UO2(II),...
-
Renata Tomczak-Wandzel dr inż.
People -
Dipodal Tetraamide Derivatives of 1,10-Diaza-18-Crown-6 and Alkylmalonic Acids—Synthesis and Use as Ionophores in Ion Selective Membrane Electrodes
PublicationNovel dipodal derivatives of an 18-membered diaza-crown ether with two diamide chains featuring methylmalonic or butylmalonic acid residues were obtained and tested as ionophores in ion-selective plasticized membrane electrodes. The objective of the study was to identify measurement conditions which ensure the most favorable performance for magnesium ion-selective electrodes. The relationship between the molar lipophilic anion...
-
Effect of Laminar Pulsatile Fluid Flow on Separation of Volatile Organic Compounds from Aqueous Solution by a Hollow Fiber Membrane-Based Process
PublicationIn this study, a laminar pulsatile fluid flow was used for the separation of benzene, toluene, ethylbenzene, and xylene isomers (BTEX) from aqueous solutions. Polyether sulfone hollow fiber membrane has been applied to this process. The effects of BTEX concentration, and feed and extraction flow rates were examined. It was found that the application of the pulsatile fluid flow with...
-
Ultrasound-assisted solvent extraction of porous membrane packed solid samples: A new approach for extraction of target analytes from solid samples
PublicationFor the first time, a porous membrane-based method is proposed for the extraction of target analytes directly from the solid samples. This method involves the packing of solid sample inside a porous polypropylene membrane sheet whose edges are heat-sealed to fabricate a bag. This bag is immersed in a suitable solvent and the analytes are extracted by the application of ultrasound energy. The various factors that affect the extraction...
-
Mechanism of Binding of Antifungal Antibiotic Amphotericin B to Lipid Membranes: An Insight from Combined Single-Membrane Imaging, Microspectroscopy, and Molecular Dynamics
PublicationAmphotericin B is a lifesaving polyene antibiotic used in the treatment of systemic mycoses. Unfortunately, the pharmacological applicability of this drug is limited because of its severe toxic side effects. At the same time, the lack of a well-defined mechanism of selectivity hampers the efforts to rationally design safer derivatives. As the drug primarily targets the biomembranes of both fungi and humans, new insights into the...
-
Extraction and Analysis of Bisphenols and Their Derivatives in Infant and Toddler Ready-to-feed Meals by Ultrasound-assisted Membrane Extraction Followed by LC MS/MS
PublicationThis research developed an ultrasound-assisted membrane extraction coupled with liquid chromatography-tandem mass spectrometry method for the determination of nineteen bisphenols and their derivatives in infant and toddler ready-to-feed meals. The calibration curves for all analytes were linear in the tested range, and the limit of detection and limit of quantitation were in the range 0.27 to 0.79 ng/g and 0.80 to 2.4 ng/g, respectively....
-
Simultaneous determination of droxidopa and carbidopa by carbon paste electrode functionalized with NiFe2O4 nanoparticle and 2-(4-ferrocenyl-[1,2,3]triazol-1-yl)-1-(naphthalen-2-yl) ethanone
Publication -
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublicationThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...
-
Determination of moisture resistance of covered electrodes according to PN-EN ISO 14372
PublicationMoisture present in the electrode covering is one of the sources of diffusible hydrogen in welded joints. In order to study the diffusible hydrogen content in deposited metal, a stand for moisturizing covered electrodes, in accordance with the PN-EN ISO 14372 standard, was built. After the stand was completed, a test of moisturizing the electrodes was carried out and measurements of the diffusible hydrogen content in deposited...
-
pH-tunable equilibria in azocrown ethers with histidine moieties
PublicationEtery koronowe posiadające elektro- i fotoaktywne reszty azowe oraz ugrupowania z ruchliwymi protonami jak w grupie COOH histydyny charakteryzują się unikalnym, zależnym od pH, efektem stymulowania pozornej obecności/nieobecności ugrupowania azowego. Obserwowane różnice właściwości elektrochemicznych eterów azokoronowych z resztą N-acetylohistydyny lub resztami imidazolu uwidaczniają się przebiegiem chemicznej redukcji w silnie...
-
Jacek Ryl dr hab. inż.
PeopleI have obtained my PhD in chemical technology in 2010. In the same year, I was employed at the Department of Electrochemistry, Corrosion and Materials Engineering at the Faculty of Chemistry. In 2018 I received habilitation at the Faculty of Chemistry GUT in technical sciences in the discipline of chemical technology. From 2021, he was employed at the Institute of Nanotechnology and Materials Science at the Faculty of Technical...
-
Evolution of the nanostructure of Pt and Pt–Co polymer electrolyte membrane fuel cell electrocatalysts at successive degradation stages probed by X-ray photoemission
PublicationWe present a set of XPS (X-ray photoemission spectroscopy) measurements and detailed data-analysis of electrodes for polymer electrolyte membrane fuel cell (PEMFC) based on carbon supported catalysts (Pt and Pt–Co) subjected to a step-like potential cycling (accelerated degradation test). The results of the measurements complete and corroborate parallel TEM (transmission electron microscopy), XRD (X-ray diffraction) and XAS (X-ray...
-
Development of a new green analytical methodology for the determination of phthalates in single-use babies diapers using ultrasound-assisted extraction and polypropylene porous membrane
PublicationA green extraction strategy was developed and utilized for the extraction and determination of phthalates. The extraction is based on ultrasound-assisted extraction and a polypropylene porous membrane. The Box-Behnken model was performed to optimize the extraction condition. The optimal extraction conditions are 5.5 mL of ethyl acetate, 10 min of extraction time and 55 C for extraction temperature. The developed green extraction...
-
Membrane in tandem with a helical sorbent trap as continuous sampling technique of the polyvinyl chloride thermo-oxidative degradation products for their on-line gas chromatographic monitoring
Publication -
Hydrophobic PVDF hollow fiber membranes with narrow pore size distribution and ultra-thin skin for the fresh water production through membrane distillation
Publication -
Adaptation of phenol-degrading Pseudomonas putida KB3 to suboptimal growth condition: A focus on degradative rate, membrane properties and expression of xylE and cfaB genes
Publication -
Studies on removal of Zn(II), Cd(II) and Pb(II) ions in polymer inclusion membrane transport with calix[4]-crown-6 derivatives
PublicationZbadano selektywność procesu wydzielania jonów cynku(II), kadmu(II) i ołowiu(II) z wodnych roztworów azotanowych zawierających równomolową mieszaninę tych trzech metali (cMe= 0,01 M) w procesie transportu przez polimerowe membrany inkluzyjne (PIM) przy użyciu w roli przenośników jonów pochodnych kaliks[4]-korony-6. Membrany typu PIM syntezowano z trójoctanu celulozy (nośnik), eteru o?nitrofenylopentylowego (pastyfikator) i pochodnych...
-
Preparation and physicochemical characterization of ceramic supports for supported liquid membranes
PublicationImmobilizowane membrany ciekłe stały się przedmiotem intensywnych badań w ostanich latach, głównie w procesach oczyszczania strumieni gazowych. Kluczowym czynnikiem mającym wpływ na efektywność tych procesów ma czas życia układu membranowego, a zatem odpowiedni dobór nośnika i fazy membranowej. W porównaniu do nośników polimerowych, ceramiczne charakteryzują się większą grubością, jednak są bardziej stabilne termicznie. Praca...
-
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 16. Synthesis of 25, 26, 27, 28-tetrakis(piperidinethiocarbonylmethylene)-p-tert-butylcalix[4]arene and its interaction with metal ions
PublicationThe synthesis, characterisation and X-ray crystal structures of p-tert-butyl-calix[4]arenethioamide L and its complex with lead L-Pb2+ is reported. The cation-binding properties in solution have been assessed by liquid-liquid extraction of the metal picrates from water into dichloromethane and by stability constants determination in acetonitrile using UV-absorption spectrophotometry or potentiometry. The compound was used as active...
-
The comparison of the removal of copper(II) and zinc(II) ions from aqueous solution using 2,6-diaminopyridine in a polymer inclusion membrane and in a classic solvent extraction
Publication -
Modelowanie procesów oscylacyjnych w układach z membraną ciekłą i kationowym surfaktanetm = Modeling of oscillation processes in systems with liquid membrane and cationic surfactant
PublicationBadano mechanizm oscylacji róznicy potencjału elektrycznego między fazami wodnymi trójfazowego układu z membraną ciekłą zawierającą kwas pikrynowy rozpuszcony w nitrobenzenie. Wodna faza donorowa zawierała kationowy surfaktant (bromek heksadecylotrimetyloamoniowy) i etanol. Faza akceptorowa składała się z wodnego roztworu sacharozy. Mechanizm sugeruje, że gwałtowna adsorpcja i desorpcja surfaktantu na granicy fazy akceptorowej...
-
Rozróznianie substancji odpowiedzialnych za wrażenia smakowe za pomocą oscylatorów z membraną ciekłą.Recognition of substances responsible for taste by using liquid membrane oscillators.
PublicationOtrzymano krzywe oscylacyjne oscylatorów z membraną ciekłą zawierających anionowy (oleinian sodu) lub kationowy (chlorek brnzylodimetylotetradecyloamoniowy) surfaktant i substancje należące do czterech podstawowych klas samaku (słony, słodki, kwaśny i gorzki). Dla każdego przypadku zrekonstuowano portrety fazowe metodą opóźnienia czasowego. Stwierdzono, iż oscylatory z kationowym surfaktantem wydają sie byż korzystniejsze do rozróżniania...
-
SEM and Raman studies B:CNWs and BDD electrode used for electrochemical paraquat determination
Open Research DataThe dataset contains the scanning electron micrographs (SEM) and Raman spectra of B:CNWs and BDD samples deposited by MW-PECVD. SEM was used to characterise the morphology of BDD and B:CNW. In contrast, RAMAN was used to reveal the main differences in the crystalline structure of BDD and B:CNWs.
-
A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures
PublicationThe detection of glucose at low concentrations using electrochemical sensors is of great importance due to the possibility of using different human body fluids than blood, such as e.g. urine, saliva, sweat or tears. The interest behind those biofluids is related to their utility in non-invasive sugar determination. In this work, we present flexible, fully biocompatible electrode material based on Au nanoparticles immobilized onto...
-
Organic electroluminescent devices containing phosphorescent molecules in molecularly doped hole transporting layer.
PublicationW pracy opisano mechanizm świecenia diody dwuwarstwowej diody elektroluminescencyjnej (EL) o zewnętrznej kwantowej wydajności świecenia osiągającej 9% fot./elektron. Warstwę transportującą elektrony tworzyła pochodna osadiazolu (PBD) otrzymana metodąnaparowania próżniowego. Warstwę transportującą dziury uzyskano przez wylanie roztworu poliwęglanu(PC), dendrymeru aminowego m-MTDATAoraz fosforyzującego kompleksu irydu Ir(ppy)3 i...
-
Lower Rim Substituted tert-Butyl Calix[4]arenes (Part IV). Calix[4]arene-Crown Ethers as Ionophores in Plasticized PVC-membrane electrodes.
PublicationPrzedstawiono syntezę i charakterystykę trzech p-tert-butylokaliks[4]aren-koron-4, -5, -6 (związki 2 - 4 o różnej długości łańcucha polyoksaetylenowego łączącego distalne grupy OH). Syntezowane związki wykazują wysoką selektywność na kationy sodu, potasu lub cezu. Badano zależność pomiędzy stereochemiczną strukturą tych ligandów, a wyznaczonymi potencjometrycznie współczynnikami selektywności oraz wyznaczonymi stałymi trwałości...
-
Recent advances in the recovery of precious metals (Au, Ag, Pd) from acidic and WEEE solutions by solvent extraction and polymer inclusion membrane processes – a mini-review
Publication -
Ultrasound assisted solvent extraction of porous membrane-packed samples followed by liquid chromatography-tandem mass spectrometry for determination of BADGE, BFDGE and their derivatives in packed vegetables
PublicationThe problem of the presence of trace organic pollutants in food is of growing importance due to increasing awareness about their impact on newborns, infants and adults of reproductive age. Despite the fact that packaged food products offer many advantages, packaging can be a source of contamination for stored food. Thus, monitoring such pollution in food is of high importance. In this work, a novel methodology based on the solvent...
-
Materiały sensorowe o makrocyklicznej budowie. Synteza benzokoron oraz azobenzokoron. Zależność: struktura a właściwości jonoforowe
PublicationRozwój chemii supramolekularnej jest ściśle powiązany z poszukiwaniem nowych materiałów użytecznych np. w konstruowaniu sensorów chemicznych lub urządzeń molekularnych. Sensory potencjometryczne-membranowe elektrody jonoselektywne (ISE) to jedne z najczęściej stosowanych detektorów jonów metali. Substratami często stosowanymi do otrzymywania jonoforów są etery koronowe.W ramach pracy zsyntezowano szereg eterów koronowych i przeprowadzono...
-
Corrosion monitoring of selected metals in artificial seawater by harmonic synthesis method
PublicationPrzedstawiono podstawy teoretyczne nowej metody elektrochemicznej nazwanej metodą syntezy harmonicznej (SH). Metoda jest oparta na pomiarach pierwszych trzech składowych harmonicznych prądu generowanego przez korodującą elektrodę po pobudzeniu sinusoidalnym sygnałem napięciowym bardzo niskiej częstotliwości. Na tej podstawie rekonstruowana jest dyskretna quasi-stacjonarna charakterystyka polaryzacyjna elektrody. Jej analiza numeryczna...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion
Open Research DataThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K (72h digestion period). Different enzyme concentrations were evaluated: 0.2, 0.4, 0.6 and 0.8 mg/ml. The studies were performed before surface activation, during and...
-
SEM image and EDS map of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with EDS map analysis results. This study were performed for better understanding the chemical composition of flat like structures that occurs in electrode. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope...
-
SEM image and line EDS of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with line EDS analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 20 kV in a high vacuum mode. The chemical compositions of the investigated powder...
-
The electrochemical response to Au electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the Au electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration, with...
-
Melatonin maintains mitochondrial membrane potential and attenuates activation of initiator (casp-9) and effector caspases (casp-3/casp-7) and PARP in UVR-exposed HaCaT keratinocytes
Publication -
Investigation of mechanism of desmopressin binding in vasopressin V2 receptor versus vasopressin V1a and oxytocin receptors: Molecular dynamics simulation of the agonist-bound state in the membrane–aqueous system
Publication -
Immunocytochemical and biochemical detection of EMMPRIN in the rat tooth germ: differentiation-dependent co-expression with MMPs and co-localization with caveolin-1 in membrane rafts of dental epithelial cells
Publication