Filters
total: 1724
-
Catalog
- Publications 1504 available results
- Journals 36 available results
- People 37 available results
- Inventions 15 available results
- Projects 7 available results
- Laboratories 3 available results
- Research Teams 4 available results
- Research Equipment 8 available results
- e-Learning Courses 47 available results
- Events 2 available results
- Open Research Data 61 available results
displaying 1000 best results Help
Search results for: regulator napiecia
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublicationThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Speed sensorless induction motor drive with motor choke and predictive control
PublicationArtykuł przedstawia układ napędowy z silnikiem indukcyjnym, zasilanym z falownika napięcia przy zastosowaniu filtru silnikowego. System pracuje bez czujnika prędkości obrotowej. Głównym aspektem pracy jest zwrócenie uwagi na to, że zastosowanie dławika silnikowego wymaga odpowiednich zmian w strukturach sterowania i estymacji zmiennych. Zaproponowano odpowiednie rozwiązanie dla układu napędowego z regulatorem predykcyjnym prądu....
-
Random components influence on the values characterising periodic disturbances in low voltage supply lines.
PublicationAnalizowano wpływ składowych losowych na wielkości charakteryzujących zaburzenia okresowe w napięciu zasilania na przykładzie współczynnika zawartości harmonicznych (THD). Zaprezentowano sposób wyznaczania niepewności pomiaru współczynnika THD, uwzględniający występowanie korelacji pomiędzy składową podstawową i kolejnymi harmonicznymi napięcia sieci a także między poszczególnymi harmonicznymi. Przedstawiono analizę wyników z pomiarów...
-
Projektowanie układów sterowania predykcyjnego obiektami z czasem ciągłym z uwzględnieniem niepewności modelowania.**2002, 166 s. 72 rys. 15 tab. bib- liogr. 79 poz. maszyn. Rozprawa doktorska /16.12.2002/ WETI PG. Promotor: dr hab. inż. Z. Kowalczuk, prof. nadzw. PG.
PublicationPrzedmiotem pracy jest uogólniony algorytm sterowania predykcyjnego w czasieciągłym CGPC, przeznaczony do sterowania obiektami ciągłymi o dowolnym cha-rakterze ze względu na stabilność i minmalnofazowość. Przedstawione jestkompletne wyprowadzenie przepisu na regulator, zaprezentowany jest sposóbstrojenia związany z mechanizmem predykcji i polegający na rozwinięciu po-czątkowego fragmentu odpowiedzi modelu obiektu w szereg...
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
Leszek Osiecki dr hab. inż.
People -
Wpływ odkształcenia prądu różnicowego na czułość zabezpieczeń różnicowoprądowych
PublicationReferat przedstawia problematykę działania zabezpieczeń różnicowoprądowych w obwodach niskiego napięcia, w których prądy różnicowe mogą mieć przebieg odkształcony. Tak bywa w obwodach z przemiennikami częstotliwości bądź innymi odbiorami nieliniowymi, a nawet w obwodach sąsiadujących z nimi, jeśli w wyniku odkształconych spadków napięcia, napięcie zasilające je również jest odkształcone. Problem prawidłowego działania zabezpieczeń...
-
Wpływ odkształcenia prądu różnicowego na czułość zabezpieczeń różnicowoprądowych
PublicationArtykuł przedstawia problematykę działania zabezpieczeń różnicowoprądowych w obwodach niskiego napięcia, w których prądy różnicowe mogą mieć przebieg odkształcony. Tak bywa w obwodach z przemiennikami częstotliwości bądź innymi odbiorami nieliniowymi, a nawet w obwodach sąsiadujących z nimi, jeśli w wyniku odkształconych spadków napięcia, napięcie zasilające je również jest odkształcone. Problem prawidłowego działania zabezpieczeń...
-
Better understanding EMI generation of power converters
PublicationPrzedstawiono metodę przewidywania poziomu zaburzeń w układzie podwyższającym napięcie w oparciu o metodę filtracji Wienera. Pozwoliło to na określenie odpowiedzi impulsowej pomiędzy przyczyną zaburzenia (zmianą napięcia na elementach półprzewdonikowych) a zaburzeniem. Metodę zwerifikowano przy użyciu danych z symulacji oraz pomiarów w rzeczywistym obiekcie
-
Step-Up DC/DC Converters With Cascaded Quasi-Z-Source Network
PublicationW artykule zaprezentowano nowe rozwiązania dotyczące przekształtników energoelektronicznych DC-DC podwyższających napięcie z ogniw paliwowych. Istota rozwiązania zawiera się w zastosowaniu kaskadowo połączonych wejściowych obwodów pasywnych typu Quasi-Z, umozliwiających znaczne podwyższanie napięcia z wykorzystaniem stanu parcy zwarć gałęzi tranzystorowych przekształtnika.
-
Jakość energii elektrycznej w obiekcie przemysłowym
PublicationW referacie przedstawiono wyniki pomiarów parametrów napięcia zasilającego w instalacji elektrycznej zakładu przemysłowego wyposażonego w dużą liczbę odbiorników nieliniowych. W czasie pracy wymienionych urządzeń rejestrowano miernikiem parametrów sieci niewielkie zmiany napięcia zasilającego w zakresie -2,3%÷+3,1%Un o zawartości harmonicznych THD nie przekraczającej 7%. Rejestrowano krótkotrwałe wzrosty THD do 12%. Wysoki poziom...
-
Dissolved oxygen tracking and control of blowers at fast time scale.
PublicationNapowietrzanie jest bardzo ważnym i drogim procesem w oczyszczalni ścieków. Tlen jest podstawowym składnikiem dla procesów biologicznych. System napowietrzania jest skomplikowanym, hybrydowym, nieliniowym, dynamicznym systemem z dynamiką szybszą w porównaniu z wewnętrzną dynamiką tlenu rozpuszczonego w reaktorze biologicznym. Obecnie stosowane systemy sterowania są dalekie od zadowalających. Koszt pompowania powietrza do reaktora...
-
Non-linear control of induction motor in field weakening region
PublicationW referacie przedstawiono układ sterowania silnikiem asynchronicznym klatkowym, oparty na modelu multiskalarnym. Dla zaproponowanej struktury wybrano dwa wektory do transformacji zmiennych stanu: wektor prądu stojana i wektor strumienia stojana. Przepro¬wadzono badania eksperymentalne na stanowisku badawczym z silnikami indukcyjnymi o mocy 22kW, w których do odtwarzania prędkości kątowej wykorzystano obserwator prędkości kątowej...
-
Wieloobszarowa regulacja systemu turbogeneratora elektrowni jądrowej =Multiregional control of nuclear power plant turbogenerator system
PublicationW artykule przedstawiono propozycję zaawansowanej struktury sterowania układem turbogeneratora w szerokim zakresie zmian zapotrzebowania na moc czynną. Dla potrzeb syntezy tej struktury wykorzystano nieliniowe, dynamiczne modele turbiny parowej i generatora synchronicznego współpracującego z systemem elektroenergetycznym. Zaproponowane algorytmy sterowania oparte są odpowiednio o wieloobszarowe regulatory rozmyte, z lokalnymi regulatorami...
-
Lessons learned in a decade: Medical‐toxicological view of tattooing
PublicationTattooing has been part of the human culture for thousands of years, yet only in the past decades has it entered the mainstream of the society. With the rise in popularity, tattoos also gained attention among researchers, with the aim to better understand the health risks posed by their application. 'A medical-toxicological view of tattooing'-a work published in The Lancet almost a decade ago, resulted from the international collaboration...
-
Wpływ przepięć na degradację izolacji polietylenowej. VI Ogólnopolskie Sympozjum Inżynieria Wysokich Napięć - IW 2002.
PublicationOmówiono wyniki badań wskazujące na istotny w procesie degradacji izolacji polietylenowej wpływ przepięć nakładanych na napięcie przemienne. Przeprowadzone badanie termicznie stymulowanej depolaryzacji cienkich próbek folii polietylenowej narażonych napięciem przemiennym oraz skojarzonym pozwoliły określić rodzaj napięcia efektywnie wprowadzającego ładunek do polimeru, wartość ładunku i jego energię aktywacji.
-
Regulator przepływu
InventionsPrzedmiotem wynalazku jest regulator przepływu w dziedzinie napędów hydraulicznych.
-
Analiza i badania transformatora hybrydowego z przekształtnikiem AC/DC/AC współdziałającym z przełącznikiem zaczepów
PublicationRozprawa dotyczy badań nad układem transformatora hybrydowego, który oprócz możliwości regulacji ciągłej napięcia za pomocą przekształtnika energoelektronicznego, posiada układ regulacji skokowej w postaci przełącznika zaczepów. Badane urządzenie przeznaczone jest do stabilizacji napięcia w dystrybucyjnej sieci niskiego napięcia. Dzięki skoordynowanej pracy układów (ciągłego i skokowego) uzyskana zostaje tzw. Wielostrefowa Regulacja...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publicationhe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
The influence of switching impulses on degradation of polyethylene insulation
PublicationW pracy omówiono czas inkubacji i wzrostu drzewka elektrycznego rozwijającego się w izolacji polietylenowej usieciowanej w układzie ostrze - płyta uziemiona. Badania przeprowadzono przy udarach łączeniowych nałożonych na napiecie przemienne (napięcie skojarzone). Wyniki badań wskazują na istotny wpływ ładunku przestrzennego wprowadzanego napięciem udarowym na inkubację i propagację drzewienia elektrycznego.
-
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY
Journals -
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K01
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate folders).Specimen...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K09 - full run
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K06
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K04
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate folders).Specimen...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K09 - pre-run (10s)
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K08
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K07
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K05
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate folders).Specimen...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K02
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K03
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate folders).Specimen...
-
Molecular and structural basis of inner core lipopolysaccharide alterations in Escherichia coli: incorporation of glucuronic acid and phosphoethanolamine in the heptose region.
PublicationIt is well established that lipopolysaccharide (LPS) often carries nonstoichiometric substitutions in lipid A and in the inner core. In this work, the molecular basis of inner core alterations and their physiological significance are addressed. A new inner core modification of LPS is described, which arises due to the addition of glucuronic acid on the third heptose with a concomitant loss of phosphate on the second heptose. This...
-
Recent advances in transcription regulation
e-Learning CoursesRecent advances in transcription regulation
-
Problemy pomiaru prądów upływowych w diagnostyce ograniczników przepięć
PublicationW monografii opisano wybrane zagadnienia związane z diagnostyką warystorowych ograniczników przepięć wykonanych z tlenku cynku ZnO. Spośród wielu metod diagnostycznych skupiono się głównie na problemach pomiaru prądów upływowych, których znajomość między innymi umożliwia bezinwazyjną diagnostykę ogranicznika w czasie jego eksploatacji. W celu prawidłowej oceny stanu ogranicznika tą metodą analizowano wyznaczanie składowej czynnej...
-
Przyczyna uszkodzeń uzwojeń silników 6 kV 500 kW, zainstalowanych w pompowni ujęcia wody
PublicationW artykule przedstawiono analizę przyczyn uszkodzeń silników średniej mocy i SN, służących do napędu pomp ujęcia wody dla miasta. Użytkownik pompowni w celu regulacji wydatku pomp zastosował przemiennik częstotliwości niskiego napięcia, których został zasilony przez transformator 6/0,4 kV. Napięcie za przemiennikiem było podnoszone poprzez transformator 0,4/6 kV i zasilało poprzez linie kablowe silniki pomp. W ciągu 2. lat od wdrożenia...
-
Zespolony regulator przepływu mocy UPFC
Research EquipmentZespolony regulator przepływu mocy UPFC
-
Identyfikacja parametrów zastępczego schematu elektrycznego krwiobiegu nerki na podstawie niepełnych danych pomiarowych : The parameters identification of the equivalent electric circuit of the kidney blood circulation basis on incomplete measuring date
PublicationW referacie przedstawiono metodę identyfikacji parametrów elektrycznego schematu zastępczego odwzorowującego przepływ krwi przez nerkę. Napięcie potraktowano jako sygnał wejściowy, któremu w hemodynamice odpowiada ciśnienie, natomiast prąd jako sygnał wyjściowy, któremu odpowiada przepływ krwi. Przebieg napięcia aproksymowano funkcją sklejaną w celu uproszczenia procedury pomiarowej i ograniczenia fluktuacji związanych z przebiegiem...
-
Zagrożenie porażeniowe przy urządzeniach chłodniczych i klimatyzacyjnych
PublicationW artykule przedstawiono pierwotne kryteria bezpieczeństwa, czyli bezpośrednie skutki przepływu prądu przez organizm ludzki. Zaprezentowano specyfikę pracy urządzeń i instalacji elektrycznych w obiektach z urządzeniami chłodniczymi i klimatyzacyjnymi oraz czynniki wpływające na zagrożenie porażeniowe. Zdefiniowano dotyk bezpośredni, dotyk pośredni oraz napięcie dotykowe, a także przedstawiono wartości napięć dotykowych w najczęściej...
-
Synthesis, physical properties and preliminary investigation of hemocompa-tibility of polyurethanes from aliphatic resources with castor oil participation
PublicationWykonano syntezy PUR z oligoeterodiolu, dioli małocząsteczkowych, oleju rycynowego i 4,4´diizocyjanianudicykloheksylometanu. Oznaczono właściwości mechaniczne PUR, kąty zwilżania i napięcie powierzchniowe. Opisano wstępne badania zgodności PUR z ludzką krwią oraz kalcyfikacji powierzchni PUR w warunkach statycznych in vitro. Napięcie powierzchniowe otrzymanych PUR jest zbliżone do napięcia powierzchniowego naturalnych powierzchni...
-
Stanisław Galla dr inż.
PeopleStanisław Galla was born in 1970 in Gdańsk. He graduated from the Secondary Technical School of Mechanical and Electrical Engineering in Gdansk (1990). He studied at the Faculty of Electrical Engineering at Gdansk University of Technology (graduated in 1996). His PhD thesis entitled "Methodology for increasing the accuracy of low frequency measurements of periodic disturbance indicators in low voltage networks" was defended in...
-
Stanisław Czapp prof. dr hab. inż.
People -
Proportional-derivative and Model-based Controllers for Control of a Variable Mass Manipulator
PublicationW artykule prezentowano wyniki analiza numeryczna dynamiki manipulatora o zmiennej masie. W skład manipulatora wchodzą jedynie członu i przeguby obrotowe. Ładowność chwytaka jest traktowana jako jedyny element o zmiennej masie. Podobnie jak w przypadku innych manipulatorów wyposażonych w przeguby obrotowe, parametry jego dynamika zależą od aktualnego ustawienia. Gdy przemieszczenia obejmują większy zakres roboczy, w równaniach...
-
Szacowanie niepewności pomiaru mocy chwilowej w układzie do bezinwazyjnej diagnostyki łożysk.
PublicationW artykule przedstawiono tematykę dotyczącą szacowania niepewności pomiaru mocy chwilowej w układzie do bezinwazyjnej diagnostyki łożysk tocznych, składającego się z przetworników: napięcia oraz prąd-napięcie. Zaprezentowano sposób oceny niepewności pomiarowej oraz przedstawiono przykładowe wyniki wykonanych analiz. Na tej podstawie sformułowano wnioski dotyczące dokładności pomiaru w układzie przeznaczonym do bezinwazyjnej diagnostyki...
-
Nowa metoda pomiaru parametrów sieci elektroenergetycznych przy wykorzystaniu impedancyjnego obciążenia pomiarowego z regulowanym argumentem
PublicationW pracy przedstawiono problematykę pomiaru impedancji obwodu zwarciowego i jego składowych elementów w sieciach elektroenergetycznych, gdzie krzywa napięcia w miejscu pomiaru może być odkształcona. W rozprawie doktorskiej przeprowadzono analizę wpływu wyższych harmonicznych zawartych w napięciu sieci na błędy pomiaru impedancji obwodu przy stosowaniu różnych metod i przyrządów. Z przeprowadzonej analizy wynika, że wpływ odkształcenia...
-
Fuzzy track controller for ships.
PublicationPrzedstawiono projekt regulatora trajektorii zrealizowanego w oparciu o logikę rozmytą. Zadaniem regulatora jest sterowanie statkiem wzdłuż zadanej trajektorii z uwzględnieniem prędkości. Zadana trajektoria przedstawiona została w postaci linii łamanej z wyznaczona wartością prędkości z jaką statek ma poruszać się po każdym odcinku. Opracowane reguły sterowania regulatora rozmytego trajektorii poddane zostały badaniom na statku...
-
Mirosław Włas dr inż.
PeopleWykształcenie : 1987-1991 – Liceum Ogólnokształcące im. Jana Bażyńskiego w Ostródzie – profil matematyczno-fizyczny 1991-1996 Politechnika Gdańska – studia na Wydziale Elektrycznym 1997-2002 Politechnika Gdańska – studia doktoranckie na Wydziale Elektrotechniki i Automatyki 1998- 1999 Politechnika Gdańska – kurs ekonomii na Wydziale Zarządzania i Ekonomii PG 1997-2000 – kurs j. angielskiego - Zespół Lektorów BEST – Gdańsk 2003...
-
Propagowanie elektrotechniki w latach 20 i 30 XX wieku na przykładzie samouczków technicznych Wydawnictwa Brunona Kotuli
PublicationW artykule przedstawiono serię Samouczków technicznych, wydawanych w latach 20 i 30 XX wieku w Cieszynie przez znanego księgarza i wydawcę Brunona Kotulę. Seria obejmuje ok. 135 pozycji, z czego znaczną część poświęcono różnorodnym tematom związanym z elektrotechniką. Opisano przykładowe rozwiązania propagowane w Samouczkach, takie jak budowę induktora Ruhmkorffa, pozwalającego uzyskać wysokie napięcie, budowę transformatora Tesli,...
-
An Automatic Self-Tuning Control System Design for an Inverted Pendulum
PublicationA control problem of an inverted pendulum in the presence of parametric uncertainty has been investigated in this paper. In particular, synthesis and implementation of an automatic self-tuning regulator for a real inverted pendulum have been given. The main cores of the control system are a swing-up control method and a stabilisation regulator. The first one is based on the energy of an inverted pendulum, whereas the second one...
-
Trójfazowy 4-gałęziowy falownik SiC w napędzie z wysokoobrotowym silnikiem indukcyjnym
PublicationZastosowanie tranzystorów SiC w falownikach napędów wysokoobrotowych powoduje nowe wyzwania, szczególnie odnośnie generowanego w falowniku napięcia common mode (CM) o wysokiej częstotliwości. Wysokoczęstotliwościowe napięcie CM wchodzi w interakcję z pojemnościami pasożytniczymi falownika, kabla i silnika wymuszając przepływ prądów CM, które są źródłem strat w filtrach pasywnych oraz powodują zakłócenia pomiarów prądów, nieakceptowalne...
-
Trójfazowy 4-gałęziowy falownik SiC w napędzie z wysokoobrotowym silnikiem indukcyjnym
PublicationZastosowanie tranzystorów SiC w falownikach napędów wysokoobrotowych powoduje nowe wyzwania,szczególnie odnośnie generowanego w falowniku napięcia common mode (CM) o wysokiej częstotliwości. Wysokoczęstotliwościowe napięcie CM wchodzi w interakcję z pojemnościami pasożytniczymi falownika, kabla i silnika wymuszając przepływ prądów CM, które są źródłem strat w filtrach pasywnych oraz powodują zakłócenia pomiarów prądów, nieakceptowalne...