Filters
total: 1774
-
Catalog
- Publications 1257 available results
- Journals 25 available results
- Publishing Houses 8 available results
- People 122 available results
- Inventions 16 available results
- Projects 25 available results
- Laboratories 3 available results
- Research Teams 6 available results
- e-Learning Courses 259 available results
- Events 51 available results
- Open Research Data 2 available results
displaying 1000 best results Help
Search results for: OCHRONA ATMOSFERY
-
Akademia Pióra - Akademia Ochrony Zdrowia przy Uniwersytecie Wrocławskim
Publishing Houses -
Cofka ścieków
PublicationZagrożenie cofką ścieków w instalacjach. Potrzeby w zakresie ochrony. Charakterystyka urządzeń.
-
Protection and conservation of modern movement heritage in Gdynia - some examples of local Government activities
Publicationartykuł dotyczy ochrony i konserwacji acrhitektury modernizmu na przykładzie miasta Gdyni
-
Real and virtual enviromnents in environmental engineering: approaches, models, technologies, and critical issues.
PublicationW pracy scharakteryzowano zagadnienia związane z projektowaniem systemów uwzględniającym ochronę środowiska.
-
Agnieszka Ubowska dr hab. inż.
PeopleAgnieszka Ubowska, PhD Dsc Eng was born in 1978 in Piła, where she graduated from the Secondary School of Environmental Protection. In the years 1998-2003 she studied at the Faculty of Technology and Chemical Engineering of the Szczecin University of Technology, majoring in environmental protection. She obtained her doctorate in technical sciences in 2008, defending her thesis entitled "Hybrid hydrophilic acrylamide (co)polymers"....
-
Pomioary hałasu drogowego
PublicationCiągły rozwój motoryzacji i związanej z nią infrastruktury drogowej niesie ze sobą oprócz wielu niekwestionowanych korzyści również zagrożenia dla środowiska naturalnego i zdrowia człowieka. Obok emisji szkodliwych substancji do atmosfery jednym z najistotniejszych zagrożeń związanych z pojazdami i ruchem drogowym jest obecnie hałas. Jest on najbardziej odczuwalny w pobliżu głównych ciągów komunikacyjnych oraz przy trasach szybkiego...
-
Monitoring stanu powietrza atmosferycznego oraz wód powierzchniowych i podziemnych
PublicationOpisano cele i zadania i definicje Państwowego Monitoringu środowiska. Monitoring powietrza atmosferycznego obejmuje substancje gazowe oraz pyły a także wybrane substancje wchodzące w skład pyłów. Monitoring przeprowadza się z wykorzystaniem metod manualnych i analizatorów automatycznych a także za pomocą metod zdalnych. Stan powietrza atmosferycznego można oceniać na podstawie zmian wywołanych w środowisku. Nowoczesnym rozwiązaniem...
-
Przegląd metod oznaczania pozostałości pestycydów w próbkach powietrza = Methods of determination of pesticides residues in atmosphere - a review.
PublicationPestycydy to liczna i chemicznie zróżnicowana grupa związków. Są one powszechnie uŜywane na całym świecie do niszczenia i unieszkodliwiania organizmów niebezpiecznych dla ludzi i produktów. Doochrony produktów i upraw stosuje się pestycydy, które w różny sposób trafiają do atmosfery. Oznaczanie zawartości pestycydów w powietrzu jest niezmiernie waŜne, gdyŜ transport atmosferyczny jest jednymz podstawowych źródeł zanieczyszczenia...
-
1-Methyl-3-octylimidazolium Chloride − Sorption and Primary Biodegradation Analysis in Activated Sewage Sludge
PublicationCiecze jonowe są nielotne i z tego względu nie przedostają się do atmosfery, jednakże mogą zanieczyszczać wodę i gleby. Badania sposobów redukcji stężenia cieczy jonowych w środowisku jest istotne ze względu na rosnące zapotrzebowanie na biodegradowalne związki chemiczne. Ustalono, że górny limit stężeń dla pierwotnej biodegradacji chlorku 1-metylo-3-oktyloimidazolu wynosi 0.2 mM. Powyżej tego stężenia aktywność dehydrogenaz znacząco...
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublicationIn this paper performance of an electrocatalytic sensor in presence of chlorine is investigated. Presented studies concern sensor prepared in ceramic technology based on NASICON as a solid electrolyte with two round shaped platinum electrodes. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Zabytki architektury jako sfera działania samorządów terytorialnych - wybrane problemy
PublicationTekst dotyczy działań w zakresie ochrony zabytków realizowanych przez samorząd terytorialny Gdyni
-
Landscape protection in environmental impact assessment in Poland. The exa- mple of a Gdańsk fortification system which is threatened by transport in- vestments. J. Transdiscipl. Environ. Stud. [online]**2002 vol. 1 nr 2 [dos- tęp: 2002.12.20] s. 1-18, 3 rys. bibliogr. 11 poz. Dostępny w Internecie: http://www.journal-tes.dk/. ISSN 1602-2297 Ochrona krajobrazu w Ocenach Oddziaływania na Środowisko w Polsce -na przy- kładzie fortyfikacji gdańskich zagrożonych inwestycjami komunikacyjnymi.
PublicationSpecyficzny przypadek potencjalnego zagrożenia dla fortyfikacji nowożytnych Gdańska, spowodowanego nowymi, planowanymi inwestycjami komunikacyjnymi jesttłem dla ukazania możliwości wykorzystania procedury Oceny Oddziaływania na Środowisko dla ochrony i kształtowania krajobrazu.
-
USUWANIE ZWIĄZKÓW AZOTU Z ODCIEKÓW SKŁADOWISKOWYCH W PILOTOWEJ OCZYSZCZALNI HYDROFITOWEJ
PublicationOczyszczanie odcieków ze składowisk odpadów komunalnych jest jednym z aktualnych problemów inżynierii środowiska, co spowodowane jest niekorzystnym składem odcieków, przede wszystkim wysokimi wartościami ChZT i stężeniami azotu amonowego, oraz obecnością trwałych zanieczyszczeń organicznych (TZO) i metali ciężkich. Obok wysokosprawnych, lecz kosztownych metod oczyszczania, np. technik membranowych, możliwe jest zastosowanie obiektów...
-
Zrównoważone gospodarowanie ściekami na przykładzie obszarów wiejskich
PublicationW pracy podano charakterystykę sanitacji obszarów wiejskich w Polsce na tle krajów Europy Środkowej i Wschodniej oraz najnowsze przykłady zagospodarowania ścieków i osadów w systemach wykorzystujących technologie hydrofitowe.1. Metoda hydrofitowa stanowi dobry przykład inżynierii ekologicznej, a jej zastosowanie w gospodarce komunalnej umożliwia zrównoważone gospodarowanie ściekami
-
Znaczenie złóż hydrofitowych z pionowym i poziomym przepływem ścieków w przemianach frakcji azotu
PublicationW oczyszczalniach hydrofitowych wiele jednostkowych procesów usuwania zanieczyszczeń zachodzi jednocześnie np. sedymentacja , filtracja czy procesy z udziałem mikroorganizmów o różnych wymaganiach troficznych. Z tych powodów zarówno forma jak i stopień dyspersji zanieczyszczeń mogą mieć istotny wpływ na szybkość ich usuwania. W pracy przedstawiono wyniki badań prowadzone w trzech wielostopniowych systemach hydrofitowych (WSH)...
-
Measurement methods for assessing insulation condition of underground pipelines
PublicationThe paper discusses the most frequently applied measurement methods for assessing the quality of external insulation along pipelines and detecting defect locations in the protective coating. The quality of coating along a given pipeline section under investigation is assessed by determining unitary resistance of the coating, which is calculated on the basis of measurement results obtained along a pipeline subjected to cathodic...
-
Podatność na degradację poliuretanów z syntetycznym polihydroksymaślanem w środowisku utleniającym i hydrolitycznym
PublicationPoliuretany (PURs), zawierające w segmencie giętkim ataktyczny, telecheliczny poli([R,S]-3-hydroksymaślan) (a-PHB) oraz polikaprolaktonodiol (PCL) lub polioksytetrametylenodiol (PTMG), poddano degradacji hydrolitycznej i oksydacyjnej. Poliuretany poddano degradacji hydrolitycznej w buforze fosforanowym z dodatkiem NaN3 w czasie 36 tygodni oraz oksydacyjnej w roztworze CoCl2/H2O2 w czasie 16 tygodni inkubacji. Próbki inkubowano...
-
Adhesion of organic coatings to hot-dip galvanized steel
PublicationDuplex systems provide long-time corrosion protection, much longer than the sum of the lifetimes of zinc and paint used individually. However loss of adhesion between coating and zinc substrate is often found in practice. Different methods of zinc surface preparations are used in the fi eld. The aim of this study was to examine and compare coating protection when the old zinc surface, stored during long-time period (15 years) in...
-
Badania rozmieszczenia metali ciężkich w osadach dennych zbiorników retencyjnych na terenie zlewni zurbanizowanej
PublicationPotoki na terenach miejskich stanowią odbiornik dla kolektorów kanalizacji deszczowej oraz dla spływów powierzchniowych, które spłukują zanieczyszczenia z terenu zlewni. W zbiornikach retencyjnych budowanych na potokach m.in. w celu ochrony przed powodzią, następuje sedymentacja zawiesiny ogólnej, stanowiącej nośnik dla innych zanieczyszczeń, między innymi metali ciężkich. Źródłem metali ciężkich w zlewni miejskiej jest przede...
-
Diagnostyka stanu technicznego rurociągów stalowych z wykorzystaniem tłoków ultradźwiękowych wysokiej rozdzielczości
PublicationW pracy przedstawiono wybrane przykłady mozliwosci pomiarowych ultradźwiękowych tłoków wysokiej rozdzielczości do badania stanu ścianek rurociągów. Przedstawiono techniki zmierzające do precyzyjnej lokalizacji wykrywanych wad oraz opisano znaczenie i metodykę oszacowania trendów rozwojowych wad. Wskazano również na możliwości synergii informacji otrzymywanych różnymi technikami pomiarowymi w oparciu o systemy GIS. Na koniec podano...
-
Charakterystyka odcieków powstających w aspekcie wyboru metody ich oczyszcania
PublicationArtykuł obejmuje analizę odcieków generowanych w zakładach utylizacji odpadów w aspekcie ich ilości i jakości oraz możliwości oczyszczania/zagospodarowania, ze szczególnym zwróceniem uwagi na metody biologiczne, najbardziej przyjaznej środowisku. Ponad trzyletnie badania prowadzono na dwóch obiektach zlokalizowanych w woj. pomorskim, gdzie pobierano próbki ścieków technologicznych, powstających podczas sortownia oraz kompostownia odpadów...
-
Wpływ ścieków przemysłowych na energochłonność i efektywność procesów technologicznych w komunalnej oczyszczalni ścieków
PublicationW artykule skupiono się na przedstawieniu wpływu jakości i ilości ścieków przemysłowych wprowadzanych do sieci kanalizacyjnej PEWIK GDYNIA Sp. z o. o. na stabilność procesów technologicznych. Określono również wpływ ścieków przemysłowych na energochłonność i efektywność oraz na wzrost kosztów oczyszczania ścieków komunalnych w Grupowej Oczyszczalni Ścieków „Dębogórze” w latach 2012-2015.
-
Application of Eco-innovative Technologies of Nutrients Removal in Wastewater – Case Study BARITECH Project
PublicationEco-innovative technologies in wastewater treatment should provide not only stringent standards for the quality of treated wastewater but also ensure maximum recovery of energy and raw materials from wastewater. One of the ways to improve the removal efficiency of nitrogen and phosphorus compounds in existing conventional wastewater treatment plants is pretreatment of reject water generated during the mechanical...
-
Efficiency of Wastewater Treatment in Single-Family Constructed Wetlands in Kaszuby Lake District
PublicationIn the paper results of investigation upon three different configurations of single family treatment wetlands were presented. It was indicated that the application of treatment wetlands for single family effluent is a effective and sustainable solution for wastewater treatment in the rural areas. In spite of the receiving higher concentration of pollutants in comparison to the TWs operated in Europe and USA analysed TWs ensure...
-
Influence of Wastewater Treatment Technology on Particle Size Distribution in the Effluent
PublicationSuspended solids in water and wastewater usually carry quite a large load of pollutants (organic substances, nutrients, heavy metals, etc.) adsorbed on the particles surface. Particles of different sizes carry different types and quantities of pollutants. Therefore, particle size distribution is of importance in waster and wastewater treatment. In the article the influence of different treatment technologies on particle size distribution...
-
Corrosion monitoring by harmonic analysis in aqueous environments
PublicationThis paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at...
-
Monitorowanie korozji w strefach zagrożonych wybuchem, na przykładzie korozji zbiorników solanki na platformie wiertniczej
PublicationW pracy przedstawiono specyfikę budowy automatycznego systemu monitorowania korozji w strefie przeciwwybuchowej. Omówiono wymagania prawne budowy systemu monitorowania korozji w strefach wybuchowych. Przedstawiono wyniki badań testowych
-
PROBLEMS WITH CORROSION PROTECTION STEEL STACKS IN FGD SYSTEMS
PublicationThis paper presents problems associated with corrosion of steel stacks and changes in philosophy of corrosion protection when implemented into flue gas desulphurization systems. In-situ tests were taken by means of electrochemical impedance spectroscopy at a stack which discharges flue gas before wet lime/limestone desulphurization. A very rapid soaking of spherical infill vinylester coating with electrolyte has been observed....
-
Problemy z powłokami antykorozyjnymi na elementach wyposażenia obiektów mostowych
PublicationOpisano problem wadliwości zabezpieczenia antykorozyjnego w zakresie malarskich powłok ochronno-dekoracyjnych wykonywanych na stalowych elementach barier zabezpieczonych uprzednio poprzez ocynkowanie metodą zanurzeniową na gorąco. Wykorzystując przykłady pochodzące z różnych obiektów przedstawiono powtarzający się problem delaminacji powłok malarskich, niezależny od rodzaju zastosowanych wyrobów lakierniczych oraz znacznego rozwoju...
-
Assessment of the Water Needs of Fruit Plants in the Perspective of Climate Change
Publication -
The Water Requirements of Grapevines (Vitis vinifera L.) Under Climatic Conditions of Central Poland
Publication -
Water Footprint Index (WFTP) for Poznań as a Tool for Assessing Water Management in Urban Areas
Publication -
Effects of Contamination with Gasoline and Diesel Oil on Shear Strength of Coarse Grained Soil
Publication -
Precyzyjna lokalizacja i parametryzacja wad korozyjnych ścianek rurociągów stalowych przy wykorzystaniu tłoków inteligentnych
PublicationW artykule przedstawiono sposoby pozyskiwania danych o stanie technicznym dalekosiężnych rurociągów stalowych, w szczególności ropy surowej i paliw ropopochodnych. Scharakteryzowano kilka technik diagnostyki rur przy pomocy autonomicznych urządzeń pomiarowych typu ''tłok inteligentny'', z podziałem na typy wykrywanych obiektów: deformacja średnicy wewnętrznej, korozja i wady materiałowe, zmiany w trajektorii rurociągu. Przedstawiono...
-
Nowe metody badań korozji i pękania wodorowego materiałów eksploatowanych w umiarkowanych warunkach
PublicationPrzedstawiono założenia testu niskocyklowego zmęczenia nawodorowanego materiału oraz oceny odporności korozyjnej biomateriału bazującej na oznaczaniu ilości metalu w roztworze.
-
Ocena odporności powłok organicznych na niszczenie zmęczeniowe o charakterze mechanicznym
PublicationW pracy opisano metodę oceny trwałości organicznych powłok ochronnych eksploatowanych w warunkach oddziaływania cyklicznych naprężeń mechanicznych. Wywoływane w ten sposób niszczenie zmęczeniowe dotyczy powłok chroniących m.in. mosty, wiadukty, maszty, kadłuby jednostek pływających, korpusy maszyn i urządzeń itp. Okazuje się jednak, iż ten aspekt degradacji powłok pozostaje niedoceniany, o czym świadczy skromna liczba publikacji...
-
Pomiar impedancji metodą skanowania częstotliwościowego
PublicationW pracy przedstawiono nową metodę pomiaru impedancji. Bazuje ona na ciągłym niestacjonarnym sygnale pobudzającym CHIRP którego częstotliwość zmienia się wykładniczo w czasie. W procesie rejestracji pobudzenia i odpowiedzi prądowej zastosowano zmienną częstotliwość próbkowania. Stwierdzono iż dokładność wyników otrzymywanych tą metodą jest wprost proporcjonalna do rozdzielczości częstotliwościowej z jaką otrzymywane są wartości...
-
Niedestrukcyjne wyznaczanie adhezji międzywarstwowej w powłokowych systemach ochronnych
PublicationPrzedstawiono zagadnienia pomiaru adhezji (przyczepności) międzywarstwowej w wielowarstwowych systemach powłokowych, stosowanych do ochrony przed korozją konstrukcji metalowych. Dotychczas stosowane metody mają charakter destrukcyjny i ich wyniki obarczone są wpływem sposobu wykonania pomiaru. Zaprezentowano koncepcję niedestrukcyjnego monitorowania adhezji międzywarstwowej przy wykorzystaniu specjalnego czujnika oraz techniki...
-
Kinetyka formowania się tlenku miedzi(I) na elektrodzie Cu w oparciu o badania impedancyjne
PublicationWykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej (DEIS) do wyznaczenia chwilowych widm impedancyjnych w zakresie potencjałów formowania się warstwy pasywnej tlenku miedzi (I) w roztworze 0.1M NaOH. Autorzy skupili się na określeniu charakteru zmian parametrów impedancyjnych towarzyszących powstawaniu monowarstwy Cu-OHads. Do analizy zastosowano elektryczny obwód zastępczy R(CR)(COR). Zmiany tych parametrów...
-
Deis assessment of intergranular corrosion process proceeding on AISI 304 stainless steel
PublicationW pracy przedstawiono nowe podejście do badania mechanizmu i intensywności korozji międzykrystalicznej. Badania przeprowadzono przy wykorzystaniu techniki dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS), która pozwala na jednoczesne rejestrowanie chwilowych zmian impedancji oraz prądu stałego badanego układu. Tym samym możliwe jest otrzymanie z jednego pomiaru informacji dotyczących zarówno mechanizmu korozji międzykrystalicznej,...
-
Analiza czasowo-częstotliwościowa standaryzowanych sygnałów pól prądów błądzących
PublicationPrzedstawiono metodę analizy mierzonych sygnałów pól prądów błądzących w łącznej dziedzinie czasu i częstotliwości. Wskazano zalety procedury standaryzacji rejestrów pomiarowych, które są następnie poddawane analizie czasowo-częstotliwościowej. Standaryzacja pozwala na jakościowe i ilościowe porównanie wyników analiz dzięki zlokalizowaniu różnych rejestrów sygnałowych w tej samej dziedzinie. Jest nią dziedzina odchylenia standardowego....
-
Zastosowanie metody emisji akustycznej i metody dynamicznej elektrochemicznej spektroskopii impedancyjnej do badania odporności korozyjnej stopów aluminium
PublicationPrzedstawiono wyniki badania stopów aluminium metodą DEIS oraz metodą emisji akustycznej. Badania przeprowadzono w roztworze buforu boranowego (pH ) domieszkowanego jonami chlorkowymi w celu zwiększenia agresywności korozyjnej. Obydwa badane stopy aluminium ulegają w tych warunkach korozji wżerowej. Stwierdzono, że pierwsze sygnały emisji akustycznej pojawiają się przy potencjałach niższych niż potencjały, przy których następuje...
-
Badania elektrochemiczne stopu Al-Mg podczas realizacji procesu rozciagania
PublicationW pracy wykonano badania metodą dynamicznej spektroskopii impedancyjnej (DEIS) podczas pomiarów mechanicznych polegających na rozciąganiu próbek wykonanych ze stopu typu Al-Mg aż do zerwania. Stwierdzono, że w zakresie sprężystym zachodzi zjawisko mechanicznego pękania warstwy pasywnej, mające wpływ na znaczne załamanie się właściwości barierowych warstwy i w związku z tym początek procesów korozyjnych na powierzchni. W zakresie...
-
Skaningowa impedancyjna mikroskopia sił atomowych
PublicationW pracy przedstawiono nowatorskie podejście do analizy impedancyjnej sprzężonej z mikroskopią sił atomowych. Stosowane współcześnie metody pomiaru impedancyjnego w kontaktowym trybie AFM opierają się na punktowym pomiarze zmiennoprądowym z wykorzystaniem sekwencyjnego, sinusoidalnego pobudzania badanego obiektu. Autorzy proponują wykorzystanie techniki dynamicznej, co umożliwia uzyskiwanie widm impedancyjnych w warunkach ciągłego...
-
Heavy Metals and Metalloids Leachability from Composite Ground Materials Peat – Fly Ash – Lime
Publication -
Aspekty korozyjne metody termicznej usuwania bakterii Legionella
PublicationPrzedstawiono stan prawny związany z wykrywaniem bakterii Legionella w instalacjach wodnych oraz zalecanych metod usuwania bakterii. Zwrócono uwagę na brak precyzyjności zapisów rozporządzenia Ministra Infrastruktury w kwestii możliwości wystąpienia korozji rur ze stali ocynkowanej na wskutek zjawisk przebiegunowania powłoki cynkowej. Przedstawiono przyklad korozji rur wody ciepłej ze stali ocynkowanej w duzym obielcie hotelowym...
-
Badania procesu trawienia stali wysokostopowej za pomocą spektroskopii impedancyjnej
PublicationPrzeprowadzono badania trawienia stali wysokostopowej w mieszaninie kwasu HF IHNO3 wykorzystując elektrochemiczna spektroskopie impedancyjną. W celu odwzorowania warunków naturalnych eksperyment przeprowadzono przy uzyciu DEIS w trybie galwanostatycznym z wypadkowym prądem równym zero. Wyznaczone zostały zmiany parametrów elektrycznych opisujących układ ew czasie zmian. Zaobserwowano wpływ stężenia HF na czas trwania procesu.
-
Zwiększenie odporności stali austenitycznych poprzez obróbkę chemiczna powierzchni
PublicationPrzedstawiono wyniki badań elektrochemicznych stali stopowej 1.4301 w środowisku korozyjnym zawierającym jony chlorkowe. Powierzchnia stali została poddana przed badaniami różnym typom obróbki powierzchniowej. Porównano odporność na korozję wżerową stali poddanej trawieniu, trawieniu i pasywacji oraz samej pasywacji. Stwierdzono poprawę odporności stali poddanej dodatkowej obróbce powierzchniowej w stosunku do stali przygotowanej...
-
Emisja akustyczna podczas korozji stopów na bazie metali lekkich
PublicationPrzedstawiono wyniki badań elektrochemicznych metodą polaryzacji cyklicznej oraz emisji akustycznej technicznie czystego aluminium(stop1050) oraz magnezu. W przypadku aluminium aktywność akustyczna jest związana z inicjacją i wzrostem wżerów. Aktywność akustyczna magnezu występuje w obszarze inicjacji i wzrostu wżerów oraz w czasie repasywacji wżerów.
-
Kontrola stanu wykładzin przeciwkorozyjnych przy zastosowaniu spektroskopii mikrofalowej i metod chemometrycznych
PublicationPrzedstawiono nową niedestrukcyjną metodę kontroli jakości nowych wykładzin przeciwkorozyjnych na podłożu metalowym oraz oceny ich stanu w trakcie eksploatacji przy zastosowaniu spektroskopii mikrofalowej w szerokim zakresie częstotliwości od 6,5 do 20 GHz. Uzyskane dane poddawane są obróbce chemometrycznej w celu redukcji danych doświadczalnych i wizualizacji rezultatów. Zaprezentowano podstawy teoretyczne metody oraz przykładowe...