Filters
total: 24442
-
Catalog
- Publications 19589 available results
- Journals 27 available results
- Publishing Houses 5 available results
- People 706 available results
- Inventions 95 available results
- Projects 270 available results
- Laboratories 18 available results
- Research Teams 40 available results
- Research Equipment 8 available results
- e-Learning Courses 1738 available results
- Events 593 available results
- Open Research Data 1353 available results
displaying 1000 best results Help
Search results for: POWŁOKI NA IMPLANTY
-
Zastosowanie metody georadarowej w badaniach konstrukcji podłogi posadowionej na gruncie
PublicationDiagnostyka nieniszcząca konstrukcji podłogi posadowionej na gruncie. Zastosowanie techniki georadarowej do badań podłogi. Metodologia badań. Wyniki identyfikacji ilości i rozkładu zbrojenia oraz występowania potencjalnych uszkodzeń betonu.
-
Wpływ metody trawienia i spiekania na właściwości mechaniczne powłok z nanorurek węglowych osadzonych elektroforetycznie na podłożu Ti13Nb13Zr
PublicationDo eksperymentu użyto stopu tytanu Ti13Zr13Nb, który ze względu na swój skład chemiczny i właściwości mechaniczne stanowi doskonały materiał do zastosowań w inżynierii medycznej. Celem pracy była ocena wpływu przygotowania podłoża (rodzaj zastosowanego odczynnika trawiącego) oraz obróbki końcowej (proces spiekania) powłok z wielościennych nanorurek węglowych na ich właściwości mechaniczne (nanotwardość, moduł Younga). Do wytworzenia...
-
Experimental Research of Implant-Fascia Connections
PublicationW pracy przedstawiono wyniki identyfikacji siły zrywającej połączenie implantu z powięzią wykonane z użyciem różnych typów łączników: zszywek lub szwów chirurgicznych. Rozważono pięć typów łączników i pięć typów implantów.
-
Ocena regeneracyjnych powłok napawanych plazmowo i laserowo na przylgnie zaworów ze stali H10S2M
PublicationW artykule dokonano oceny warstw napawanych plazmowo i laserowo proszkami na bazie kobaltu na przylgnie zaworów okrętowych. Badano wpływ zróżnicowanej budowy warstw napawanych na ich mikrotwardość. Przeanalizowano wpływ składu chemicznego proszków na własności warstw.
-
Stereometria warstwy wierzchniej porowatej powłoki ceramicznej po docieraniu
PublicationOmówiono strukturę geometryczną powierzchni warstwy wierzchniej porowatej powłoki ceramicznej po docieraniu. Parametry chropowatości analizowano dla powłoki Cr2O3. Zauważono, że do oceny stereometrii tego typu powierzchni przydatnym jest stosowane niektórych parametrów chropowatości wyznaczanych na podstawie krzywej udziału nośnego.
-
Ocena możliwości zastosowania obróbki laserowej i implantacji jonowej stopów metali na implant stawu kolanowego
PublicationZagadnieniem podjętym w niniejszym referacie jest zmodyfikowanie warstwy wierzchniej stopu tytanu Ti6Al4V przeznaczonego na implanty. Autor opisuje metody modyfikacji powierzchni w wyniki nakładania warstwy węglowej metodą PA CVD (ang. Plasma Assisted Chemical Vapour Deposition) oraz warstwy hydroksyapatytu metodą zol-żel i elektrochemiczną. Badania zostały przeprowadzone w laboratoriach Zakładu Biomateriałów, Katedry Inżynierii...
-
Metal implants in ostheosynthesis - construction solutions, materials and applications
PublicationThe aim of the article is to present two case studies on intramedullary nails. The research included the evaluation of the type of fracture and the analysis of microstructure, chemical composition and hardness of the implant material.
-
Analiza numeryczna propagacji fali elektromagnetycznej w konstrukcji podłogi posadowionej na gruncie
PublicationPopularną techniką wspomagającą interpretację map georadarowych jest modelowanie numeryczne propagacji pola elektromagnetycznego z użyciem metody różnic skończonych w dziedzinie czasu (FDTD). W pracy przedstawiono analizy numeryczne przeprowadzone dla konstrukcji podłogi posadowionej na gruncie, która wcześniej została poddana badaniom metodą georadarową. Przeanalizowano modele numeryczne dla konstrukcji idealnej oraz uszkodzonej....
-
The influence of biological environment on the silver-coated implants
PublicationThis paper deals with implants covered with nanosilver
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublicationTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
BIOMATERIALS AND IMPLANTS IN CARDIAC AND VASCULAR SURGERY - REVIEW
PublicationCurrently, on prosthesis in cardiac blood vessels and heart valves are used materials of animal or synthetic origin. For animal materials include, among others pericardial sac in which is the heart. Materials such as this (natural) are characterized by a remarkable biocompatibility within the human body, but their main disadvantage is the relatively low durability. In turn, synthetic materials, which include the austenitic chromium-nickel-molybdenum...
-
Porous materials used as inserted bone implants
PublicationArtykul zawiera przegladowa analize literatury dotyczaca scaffoldow
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublicationPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
New techniques assisting cochlear implants fitting.
PublicationW referacie przedstawiono metodę telemetrii odpowiedzi neuronalnej (SoE), którą zastosowano w celu oceny amplitudy sygnału, która będzie wywoływała percepcję słuchową poprzez pobudzenie elektrod implantu ślimakowego. Jest to obiektywna metoda wyznaczania skuteczności systemów implantów ślimakowych.
-
CLINICAL ORAL IMPLANTS RESEARCH
Journals -
Reactions on the surface of the implant under the influence of biofilm
PublicationThe contact of a biomaterial with the biological environment in in vitro and in vivo tests leads to the production of a particular ecosystem in which the active roles perform both, the material surface and the extracellular matrix protein forming a biofilm. Proteins affect cell and bacteria adhesion processes, biological activity of cells and activation of inflammatory response.The knowledge of the reaction mechanisms active on...
-
Materials Design for the Titanium Scaffold Based Implant
PublicationThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...
-
Materials Design for the Titanium Scaffold Based Implant
PublicationThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...
-
Stenty naczyniowe – problematyka i biomateriały
PublicationAngioplastyka z opcjonalną implantacją stentu odgrywa ważną rolę w leczeniu chorób układu sercowo-naczyniowego w przebiegu miażdżycy. Obecnie na rynku można znaleźć implanty naczyniowe z różnych materiałów, pomimo tego nadal prowadzone są badania nad nowymi technologiami zapewniającymi lepsze własności mechaniczne, fizykochemiczne i biologiczne powłokom, a także usprawniającymi sposoby uwalniania leków. Stenty uwalniające leki...
-
Nanotechnologie w implantologii – osiągnięcia i wyzwania
PublicationAktualnie nanotechnologia jest jedną z najszybciej rozwijających się gałęzi przemysłu, w tym również w zakresie medycyny i implantologii. Osiągnięcia nanotechnologii wykorzystuje się w obrazowaniu, diagnostyce, leczeniu chorób nowotworowych i bólu, lecz również szeroko w obszarze projektowania i wytwarzania implantów, w tym głownie modyfikacji powierzchni materiałów, które mają za zadanie chwilowo lub permanentnie zastąpić funkcję...
-
International Journal of Implant Dentistry
Journals -
Journal of Periodontal and Implant Science
Journals -
Ekspertyza w celu ustalenia utraty właściwości powłoki epoksydowej zastosowanej na konstrukcji stalowej - Raport z badań zleconych - Numer umowy: 031008
Publication.
-
Characteristics of orthopaedic implants damage and mechanisms of its initiation
Publication -
The influence of biological environment on the appearance of silver-coated implants
PublicationDespite antibiotics preventive treatment before and after implantation, risk of infection is real. The infections at the implant surface developein a few months after applying them into the body. To prevent the development of bacteria and to reduce the risk of infection, implants coated with silver layer come into use. The paper presents the research results in biological environment on vein and orthopaedicimplants covered with...
-
Bioactive core material for porous load-bearing implants
PublicationSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
Porous biomaterial for orthopaedic implants based on titanium alloy
PublicationTytan i jego stopy są szeroko stosowane jako biomateriały dla zastosowań ortopedycznych. Badania związane z ich najlepszą odpornością na korozję i ścieranie, biozgodnością i bioaktywnością są stale prowadzone. Obecne badania koncentrują się również na projektowaniu i produkcji materiałów porowatych w oparciu o stopy np. Ti-13Nb-13Zr, które mogą być stosowane do wytwarzania implantów. Jedną z najbardziej efektywnych metod wytwarzania...
-
Stefan Krakowiak dr hab. inż.
People -
Effect of ZrO2 on corrosion behaviour of chromium coatings
PublicationW celu zbadania wpływu cząstek ZrO2 na zachowania korozyjne powłok chromowych pokryto stal chromem z elektrolitów Cr(VI) z dodatkiem i bez ZrO2. Właściwości korozyjne osadzonych warstw zbadano w elektrolicie 0,01 mol L(-1) kwasu siarkowego plus 0,5 mol L(-1) siarczanu sodu za pomocą metody spektroskopii impedancyjnej i woltamperometrii cyklicznej. Zaproponowano elektryczny obwód zastępczy dla procesu korozji i wyznaczono pęd korozji....
-
Docieranie porowatej powłoki ceramicznej z analizą wpływu wybranych parametrów obróbkowych
PublicationW pracy zamieszczono wyniki badań procesu docierania powłoki ceramicznej stosowanej miedzy innymi na współpracujące powierzchnie łożysk ślizgowych. Wyniki zawierają analizę wpływu parametrów obróbkowych takich jak: prędkość docierania v, nacisk jednostkowy p i czas docierania t, na chropowatość powierzchni i ubytek liniowy docieranej powłoki ceramicznej z trójtlenku chromu. Badania realizowano w celu wyznaczenia granicznej wartości...
-
Powłoki malarskie w ochronie przeciwkorozyjnej. Zasady stosowania i kontrola jakości
PublicationW książce przedstawiono podstawowe zasady wykonywania i kontroli jakości przeciwkorozyjnych wymalowań malarskich na konstrukcjach stalowych. Opracowanie powstało na bazie wykładów i zajęć praktycznych dla studentów Wydziału Chemicznego Politechniki Gdańskiej prowadzonych przez Katedrę Elektrochemii, Korozji i Inżynierii Materiałowej oraz realizowanych w ramach prac Katedry od około 12 lat kursów dla inspektorów powłok malarskich....
-
Application of percolation theory for description of electrical properties of conducting coatings
PublicationPrzedstawiono pomiary elektryczne i elektrochemiczne powłok organicznych przewodzących prąd elektryczny i mogących pełnić rolę anody w systemie ochrony katodowej żelbetonu. Za pomocą pomiarów impedancyjnych dokonano oceny rezystancji powłoki w funkcji zawartości grafitu. Na tej podstawie oszacowano próg perkolacji powłoki epoksydowej domieszkowanej elektrografitem. Ocenę obciążalności prądowej powłok przewodzących dokonano wykonując...
-
Ocena degradacji cieplnej powłok metodami termoanalitycznymi
Publicationw rozdziale przedstawiono ocenę degradacji powłok emalii, stanowiącej izolację przewodu nawojowego, wskutek starzenia cieplnego. przedstawiono również wyniki badań termoanalitycznych emalii w różnych stadiach degradacji. badania wykonywano przy zastosowaniu skomputeryzowanego analizatora aga/dsc1.
-
Ocena degradacji cieplnej powłok metodami termoanalitycznymi
Publicationw rozdziale przedstawiono ocenę degradacji powłok emalii, stanowiącej izolację przewodu nawojowego, wskutek starzenia cieplnego.
-
Ocena mikrostruktury powierzchni poliuretanowych powłok antyporostowych
Publicationw pracy przedstawiono wyniki badań dotyczące mikroskopowej oceny powierzchni powłok poliuretanowych antyporostowych. Powłoki otrzymano metodą prepolimerową a jako czynnik antyporostowy zastosowano pirytion cynku oraz tlenek miedzi (I)
-
Badania powłok izolacyjnych rozdzielnicy elektrycznej nn
PublicationBadania miały na celu analizę grubości pokryć izolacyjnych, a następnie określenie wytrzymałości napięciowej układu izolacyjnego rozdzielnicy. Poszukiwano oczywistej korelacji pomiędzy wytrzymałością elektryczną powłoki, a grubością warstwy izolacyjnej. Następnie wykonano dodatkową serię pomiarów powłoki z naniesionymi celowo uszkodzeniami mechanicznymi określonego rodzaju. Na podstawie zebranego materiału doświadczalnego wykonano...
-
Analizator do spektroskopii wysokoimpedancyjnej powłok antykorozyjnych
PublicationW pracy przedstawiono analizator do spektroskopii wysokoimpedancyjnej, w którym zastosowano sondę wejściową umożliwiającą pomiary impedancji do |Zx|<100Gohm w szerokim zakresie częstotliwości od 10uHz-1MHz. Opracowano metodę pomiaru impedancji opartą na próbkowaniu sygnałów oraz wyznaczaniu ich parametrów za pomocą algorytmów cyfrowego przetwarzania sygnałów. W pracy omówiono rozwiązania układowe i programistyczne, zastosowane...
-
Behaviour of Fascia-Implant Structure under the Impulse Pressure
PublicationW pracy przedstawiono badania eksperymentalne wykonane dla modeli zaoperowanych przepuklin brzusznych poddanych impulsowemu działaniu ciśnienia, analogicznego do kaszlu pooperacyjnego. Zbudowano 57 modeli zgodnie ze sztuką oparacji laparoskopowej, z użyciem powiezi świńskiej, pięciu typów implantów i pięciu rodzajów łączników. Opisano otrzymane wyniki wskazując na mocniejsze i słabsze rozwiązania operacyjne.
-
Zastosowanie próby implant do oceny spawalności stali
PublicationPraca dotyczy oceny spawalności stali o podwyższonej i wysokiej wytrzymałości w aspekcie eksperymentalnego określania skłonności do tworzenia pęknięć zimnych. W artykule opisano metodykę określania wrażliwości na pękanie próbą implant. Przedstawiono również proponowane w literaturze i autorskie sposoby opracowywania i przedstawiania wyników badań rozpatrywaną metodą i ich interpretacji.
-
The reactions occuring on the implant as a result of contact with human tissue
PublicationObecnosc implantu w ciele czlowieka powoduje liczne, czesto nieprzewidywalne skutki. Powodem takiej sytuacji jest duza roznorodnosc interakcji materialu medycznego z kontaktujaca sie z nim tkanka. Stwierdzenie to dotyczy glownie oddzialywan i skutkow zachodzacych na poziomie molekularnym w poszczegolnych komorkach kontaktujacej sie tkanki.
-
Allergy to implant components: chromium, nickiel, cobalt and titanium
PublicationImplant jest kompozycja roznych pierwiastkow: niklu, chromu, kobaltu, tytanu, molibdenu i wanadu. Pierwiastki te moga doprowadzic do alergii, egzemy i obluzowania implantu.
-
Biomateriały
e-Learning CoursesBiomateriały, powłoki, implanty, bakterie
-
Biomateriały i nanobiomateriały
e-Learning CoursesBiomateriały, powłoki, implanty, bakterie
-
The allergic and irritating reactions to metallic implants with trauma - orthopaedic patients
PublicationThe article presents the analysis of clinical operation complications after the treatment of long bones by mean of ostheosynthesis with the use of metal implants and endoprothesoplastic of hip joints.
-
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublicationThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublicationResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Preparation of the porous biomaterial based on titanium alloy for orthopaedic implants
PublicationObecnie tytan i jego stopy (Ti-6Al-4V lub Ti-13Nb-13Zr) są szeroko stosowane jako biomateriały dla implantów ortopedycznych. Stale prowadzone są badania nad ich najlepszą odpornością na korozję i zużycie ścierne oraz biozgodnością i bioaktywnością. Obecne badania również skoncentrowane są na projektowaniu, wytwarzaniu i właściwościach materiałów porowatych na podstawie na przykład stopu tytanu (Ti-13Nb-13Zr), które mogą być stosowane...
-
Biological and mechanical research of titanium implants covered with bactericidal coating
PublicationThe paper concerns the biological and mechanical properties of titanium implants with an antibacterial coating. The Ti13Zr13Nb alloy samples were coated with hydroxyapatite (HAp) coatings using the electrophoretic deposition technique (EPD). Subsequently, the surface of the samples was modified with silver, copper, and nickel nanoparticles by the immersion method. Different titanium sample types (i.e. HAp-only and nanometals-enriched...