Filters
total: 1670
displaying 1000 best results Help
Search results for: GROUNDWATER TABLE
-
Heavy stable charged particles search by novel pattern comparator processor
Publication -
Dihydroxyanthraquinones as stable and cost-effective TiO2 photosensitizers for environmental and biomedical applications
Publication -
Design of dimensionally stable composites using efficient global optimization method
Publication -
In Vitro Toxicological Screening of Stable and Senescing Cultures of Aphanizomenon, Planktothrix, and Raphidiopsis
Publication -
Repulsive Coulomb Barriers in Compact Stable and Metastable Multiply Charged Anions
Publication -
Why Are SiX5– and GeX5– (X = F, Cl) Stable but Not CF5– and CCl5–?
Publication -
Stable anions formed by organic molecules substituted with superhalogen functional groups
Publication -
Displacements of Cable-Stayed Bridge Measured With The Use of Traditional And Modern Techniques
Publication -
Theoretical analysis of the cable-stayed bridge over brda river in Bydgoszcz
PublicationThe topic of this article is the numerical analysis carried out for the cable-stayed tram (road) bridge over Brda river in Bydgoszcz. The goal of numerical studies was the verification of project assumptions and construction solutions elaborated by the autonomous team. The bridge calculations were conducted on three independent FEM models The internal forces and the elements effort under different loading schemes were examined....
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublicationThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
Standardy zasilania sieci ethernetowych przez kable transmisyjne - rozwój PoE
PublicationW artykule przedstawiono rozwój koncepcji zasilania urzadzeń sieciowych przez standardowe kable ethernetowe, w szczególnosci opisano standard IEEE 802.3at. Zanalizowano również zastosowania i perspektywy rozwoju rozwišzań ethernetowych w domach prywatnych i przemyśle.
-
Design of dimensionally stable composites using efficient global optimization method
PublicationDimensionally stable material design is an important issue for space structures such as space laser communication systems, telescopes, and satellites. Suitably designed composite materials for this purpose can meet the functional and structural requirements. In this paper, it is aimed to design the dimensionally stable laminated composites by using efficient global optimization method. For this purpose, the composite plate optimization...
-
Determination of the Bending Properties of Wire Rope Used in Cable Barrier Systems
PublicationThis paper presents research on the bending properties of 3 × 7 19-mm wire rope commonly used in road cable barriers. A total of 19 experimental tests were conducted. In addition, two nonlinear 3D numerical models of the wire rope using beam and solid finite elements were developed. Based on these models, four numerical simulations were carried out. The numerical results were validated against the experimental ones and a very good...
-
Reference FEM model for SHM system of cable-stayed bridge in Rzeszów
PublicationThe paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...
-
Achieving Efficient and Stable Deammonification at Low Temperatures—Experimental and Modeling Studies
PublicationThe short-term effects of temperature on deammonification sludge were evaluated in a laboratory-scale sequencing batch reactor (SBR). Mathematical modeling was used for further evaluations of different intermittent aeration strategies for achieving high and stable deammonification performance at decreasing temperatures. As for the biomass cultivated at high temperatures (e.g., 30 C), a higher temperature dependency (the adjusted...
-
Energy losses reduction in the medium voltage cable line – case study
PublicationThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
The influence of position of the post or its absence on the performance of the cable barrier system
PublicationRoad safety barriers are used to increase safety in potentially dangerous places on the roads. They are designed and installed on the roads to prevent any vehicle from getting outside the travelled way or from entering the opposite lane of the road. Barriers, which are used on European roads, have to undergo full scale crash tests according to the EN 1317 standards. Nowadays as a supplement to real crash tests, numerical simulations...
-
Pylon foundation of a cable stayed bridge at the motorway ring road of Wrocław
PublicationThe largest bridge of the motorway ring road of Wroclaw is a cable stayed bridge over the Odra river near Rędzin. Due to hydrogeological conditions of the ground it was not convenient to use standard bored piles of high length. Instead shorter piles were applied with additional improvement by cement injections at the pile toes. This decision was possible by extending ground investigation program and application of numerical modeling...
-
Broadband Modeling of Motor Cable Impact on Common Mode Currents in VFD
PublicationExamination of conducted EMI generation and propagation in AC motor drives fed by frequency converter requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. AC motor winding voltage transients and related common mode currents are significantly correlated with resonance effects occurring in converter's load circuits. Intensity levels of these phenomena depend...
-
Interplay between Selected Chemical and Biochemical Soil Properties in the Humus Horizons of Grassland Soils with Low Water Table Depth
Publication -
Towards a universal embedded-atom method: empirically adjusted and consistent set of atomic densities for all elements of the periodic table
PublicationModel atomu HFS został zmodyfikowany poprzez wyznaczenie indywidualnych parametrów αex dla atomów. Parametry αex wyznaczono w oparciu o energię jonizacji atomów. W oparciu o tak zmodyfikowaną metodę HFS wyznaczono rozkłady gęstości elektronów w atomach.
-
Evaluation of the Influence of Farming Practices and Land Use on Groundwater Resources in a Coastal Multi-Aquifer System in Puck Region (Northern Poland)
PublicationThis study focuses on the modeling of groundwater flow and nitrate transport in a multi-aquifer hydrosystem in northern Poland, adjacent to Puck Bay (Baltic sea). The main goal was to investigate how changes in land use and farming practices may affect groundwater recharge and submarine groundwater discharge (SGD) to the sea and the associated N-NO3 fluxes. An integrated modelling approach has been developed, which couples the...
-
Conventional and unconventional yeasts able to grow on rapeseed meal hydrolysates
Publication -
Badania eksperymentalne modelu zbiornika stalowego na stole sejsmicznym = Experimental study on steel tank model using shaking table
PublicationCylindrical steel tanks are very popular structures used for storage of products of chemical and petroleum industries. Their safety and reliability is really crucial because any failure may have serious consequences. Earthquakes are the most dangerous and also the most unpredictable dynamic loads acting on such structures. On the other hand, rockburst-induced ground motions are usually considered to be less severe due to lower...
-
Experimental Study on Steel Tank Model Using Shaking Table/ Badania Eksperymentalne Modelu Zbiornika Stalowego Na Stole Sejsmicznym
PublicationStalowe zbiorniki walcowe są bardzo popularnymi konstrukcjami używanymi do magazynowania produktów przemysłu chemicznego i naftowego. Ich bezpieczeństwo i niezawodność są kluczowe, ponieważ każde uszkodzenie może nieść za sobą bardzo poważne konsekwencje. Trzęsienia ziemi są najbardziej niebezpiecznymi, a zarazem najbardziej nieprzewidywalnymi obciążeniami dynamicznymi, które mogą oddziaływać na tego typu konstrukcje. Z drugiej...
-
Modelowanie przepływu wód podziemnych w strefie brzegowej morza - możliwości prognozowania = Groundwater flow modeling in the coastline area - prediction possibilities
PublicationSpecyficzne warunki występowania wód podziemnych w strefie brzegowej morza sprawiają, że ich eksploatacja jest sprawą złożoną i powinna być weryfikowana na modelu numerycznym. Zasadniczym zagrożeniem jest ingresja słonych wód morskich, która może być wzbudzona eksploatacją. Innym czynnikiem, który może przyczynić się do ingresji wód słonych do warstwy wodonośnej może być podniesienie się poziomu morza. W pracy przedstawiono wyniki...
-
Effect of phosphorylation of the maize starch on thermal generation of stable and short-living radicals
Publication -
Determining the Mechanical Properties of Solid Plates Obtained from the Recycling of Cable Waste
Publication -
Study of Soil Temperature and Moisture Changes in a Physical Model of an Underground Cable Line
PublicationThe ampacity of power cables is highly dependent on the thermal resistivity of the soil in which they are laid. The lower it is, the higher this ampacity. The thermal resistivity of the soil decreases as its moisture increases. Therefore, it is preferable that the soil around the cables has high moisture. Unfortunately, the heat generated in heavily loaded cables causes the migration of moisture from the surrounding soil, which...
-
Experiment-Based Study of Heat Dissipation from the Power Cable in a Casing Pipe
PublicationThe paper deals with the important challenges in terms of electricity transmission by means of underground cable lines. The power cable’s performance is characterized by an ampacity that represents its maximum electric current-carrying capacity. The ampacity of power cables depends on their ability to diffuse the heat generated by the current flow into the environment. In the performed research, the analysis of the efficiency of...
-
The Laboratory Stand for the Evaluation of Heat Dissipation from the Power Cable in a Casing Pipe
PublicationThe current carrying capacity of a power cable determines its efficiency, which depends on its capability to dissipate heat produced inside the cable, as a result of current flow, into the surrounding. The studies were conducted to determine how the characteristics of the medium around the cable affected its temperature and, as a result, its ability to transport electricity. The experimentation in the lab and real measurements...
-
Experimental and numerical analysis of the modified TB32 crash tests of the cable barrier system
PublicationRoad restraint systems, including safety barriers, are one of the means used to improve road safety. Currently, they can be allowed to general use after passing the specific crash tests. However, it is always important and desirable to evaluate their performance under various realistic conditions, which can happen on the roads. In this study, the behaviour of the cable barrier system in impact conditions different than assumed...
-
Stable and degradable microgels linked with cystine for storing and environmentally triggered release of drugs
PublicationEnvironmentally sensitive, degradable microgels based on poly(N-isopropylacrylamide) (pNIPA) crosslinked with the diacryloyl derivative of cystine (BISS) were synthesized by applying surfactant-free emulsion polymerization. pNIPA contributed the sensitivity to temperature to the microgels and the cross-linker made them degradable and sensitive to pH. The morphology of the microgels was investigated by using scanning and transmission...
-
Motor Cable Effect on the Converter Fed AC Motor Common Mode Current
PublicationAnaliza zaburzeń elektromagnetycznych przewodzonych w przekształtnikowych układach napędowych wymaga uwzględniania pojemności pasożytniczych występujących w przekształtniku, uzwojeniach silnika oraz kablu zasilającym silnik. Dynamiczne zmiany napięć na uzwojeniach silników zasilanych z przekształtników częstotliwości PWM oraz związane bezpośrednio z nimi składowe wspólne prądów zaburzeń przewodzonych są istotnie związane z zjawiskami...
-
HMSE: A tool for coupling MODFLOW and HYDRUS-1D computer programs
PublicationA new software HMSE has been developed to facilitate external coupling between two well-known programs for subsurface flow modeling: MODFLOW-2005 (saturated zone flow) and HYDRUS-1D (unsaturated zone flow). Two coupling schemes have been implemented. In the first case the groundwater recharge flux is calculated by HYDRUS-1D assuming a fixed water table position and then passed to MODFLOW input files. In the second case the water...
-
Environmental tracers and groundwater residence time indicators reveal controls of arsenic accumulation rates beneath a rapidly developing urban area in Patna, India
Publication -
Stable indirect adaptive control based on discrete-time T-S fuzzy model
PublicationThis paper presents an indirect adaptive fuzzy control scheme for uncertain nonlinear asymptotically stable plants.A discrete-time T-S fuzzy input-output model is employed to approximate the unknown plant dynamics. The T-S fuzzy model is fed with its own states, which are indeed its past outputs, rather than the measurements from the plants. Entirely based on this model, a feedback linearization control law is designed by using...
-
Novel non-covalent stable supramolecular ternary system comprising of cyclodextrin and branched polyethylenimine
Publication -
Cable stayed bridge over Vistula river in Plock. Dynamic analysis and site test
PublicationBudowę mostu przez rzekę Wisłę w Płocku ukończono w 2006 roku. Główne przęsło o długości 375 m zaprojektowano jako stalową konstrukcję podwieszoną. W celu weryfikacji konstrukcji zbudowano przestrzenny model MES. Badano zachowanie się konstrukcji mostu pod wpływem statycznego i dynamicznego obciążenia. W dalszym etapie przeprowadzono badania in - situ weryfikujące analizy numeryczne oraz założenia projektowe. Na bazie modelu MES...
-
Stable indirect adaptive control based on discrete-time T-S fuzzy model
PublicationThis paper presents an indirect adaptive fuzzy control scheme for uncertain nonlinear asymptotically stable plants.A discrete-time T-S fuzzy input-output model is employed to approximate the unknown plant dynamics. The T-S fuzzy model is fed with its own states, which are indeed its past outputs, rather than the measurements from the plants. Entirely based on this model, a feedback linearization control law is designed by using...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Simple stable discrete-time generalised predictive control with anticipated filtration of control error
PublicationPraca dotyczy uogólnionego sterowania predykcyjnego w czasie dyskretnym z antypacyjną filtracją błędu sterowania. Pokazano, iż przy spełnieniu pewnych warunków rozwiązanie problemu syntezy optymlanego regulatora predykcyjnego zawsze istnieje oraz prowadzi do stabilnego zamkniętego układu sterowania o określonych własnościach dynamicznych. W pracy rozważano także problem syntezy regulatora predykcyjnego dla modeli sterowania obiektów...
-
Design of power cable lines partially exposed to direct solar radiation – special aspects
PublicationPower cable lines are usually buried in the ground. However, in some cases, their ending sections are mounted along the supports of overhead lines. This leads to a situation where the cables are exposed to direct solar radiation and, consequentially, overheat. The paper presents the advanced computer modelling of power cables’ heating, considering their insolation as well as the effect of wind. The temperature and current-carrying...
-
DETERMINATION OF ADDITIONAL TENSION IN TOWED STREAMER CABLE TRIGGERED BY COLLISION WITH UNDERWATER MOVING OBJECT
PublicationThe paper deals with issues connected with the behaviour of a streamer cable towed by a survey seismic vessel when the cable undergoes a strike triggered by collision with an underwater moving object. The consequences of such collisions may be both threat to the life of marine animals or damage to underwater units and large economic losses suffered by vessel owners. The risk of such collisions has increased over the last years...
-
Optimum number of actuators to minimize the cross-sectional area of prestressable cable and truss structures
PublicationThis paper describes a new computational method for determining the optimum number of actuators to design the optimal and economic cross-sectional area of pin-jointed assemblies based on the conventional force method. The most active members are selected to be prestressed to redistribute stress in the whole structure, resulting in regulating the internal force of bars that face high stress. Reducing stress in critical members allows...
-
Cerclage cable augmentation does not increase stability of the fixation of intertrochanteric fractures. A biomechanical study
PublicationBackground: Intertrochanteric fractures with a posteromedial intermediate fragment are unstable because of the loss of medial support. Additional fixation with a cerclage is used in subtrochanteric fractures, but not in intertrochanteric fractures. The aim of this biomechanical study is to evaluate whether cerclage fixation improves stability of intertrochanteric fractures. Hypothesis: Our hypothesis is that the cerclage fixation...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublicationCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
An Overview of Treatment Approaches for Octahydro-1, 3, 5, 7-tetranitro-1, 3, 5, 7-tetrazocine (HMX) Explosive in Soil, Groundwater, and Wastewater
PublicationOctahydro-1, 3, 5, 7-tetranitro-1, 3, 5, 7-tetrazocine (HMX) is extensively exploited in the manufacturing of explosives; therefore, a significant level of HMX contamination can be encountered near explosive production plants. For instance, up to 12 ppm HMX concentrations have been observed in the wastewater effluent of a munitions manufacturing facility, while up to 45,000 mg/kg of HMX has been found in a soil sample taken from...
-
Spatial variability of the hydrochemistry of shallow groundwaters and surface waters of the Rensdyrbekken: A case study of a permafrost catchment in Bellsund (SW Spitsbergen, Svalbard)
PublicationProgressive climate change may have unpredictable consequences for the Arctic environment. Permafrost catchments off the west coast of Svalbard, described as “thin” and “warm,” are particularly sensitive to climate change. The interdisciplinary research on the hydrochemical response of surface and underground water functioning within a small permafrost catchment area focused on the determination of the impact of meteorological...
-
Are firefighters able to perform intraosseous access and start fluid resuscitation in an anaphylactic patient?
Publication