prof. dr hab. inż. Małgorzata Szczerska
Publikacje
Filtry
wszystkich: 146
Katalog Publikacji
Rok 2017
-
Full scattering profile of circular optical phantoms mimicking biological tissue
PublikacjaHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. In our poster, we suggest a new type of skin phantom and an optical method for sensing physiological tissue condition, basing on the collection of the ejected light at all exit angles, to receive the full scattering profile. Conducted experiments were carried out on an unique set-up for noninvasive encircled measurement. Set-up consisted...
-
Haemocompatibility of Modified Nanodiamonds
PublikacjaThis study reports the interactions of modified nanodiamond particles in vitro with human blood. Modifications performed on the nanodiamond particles include oxygenation with a chemical method and hydrogenation upon chemical vapor deposition (CVD) plasma treatment. Such nanodiamonds were later incubated in whole human blood for different time intervals, ranging from 5 min to 5 h. The morphology of red blood cells was assessed along...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublikacjaFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublikacjaIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation
PublikacjaIn brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and...
-
Tailoring the optical parameters of optical fiber interferometer with dedicated boron-doped nanocrystalline diamond thin film
PublikacjaOptical fiber interferometer using nanocrystalline boron-doped diamond film was investigated. The diamond films were deposited on glass plates using a Microwave Plasma-Enhanced Chemical Vapour Deposition (μPE CVD) sys-tem. The growth time was 3h, with boron doping level of 10 000 ppm producing films (B-NCD-10) of thickness ~ 200 nm. The presence of boron atoms in the diamond film is evident in Raman spectrum as peaks at 1212 cm-1...
-
The silver layers in fiber-optic sensors
PublikacjaIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
Rok 2016
-
Application of boron-doped diamond film and ZnO layer in the Fabry-Pérot interferometer
PublikacjaIn this article there have been presented the use of boron-doped diamond films for sensor applications. The low-finesse Fabry-Pérot interferometer working in the reflective mode has been implemented. Two kinds of reflective layers have been elaborated: boron-doped diamond thin films and zinc-oxide (ZnO) layer. Thin ZnO layers were deposited by Atomic Layer Deposition (ALD) on the face of a standard telecommunication single-mode...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublikacjaThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
Application of thin dielectric films in low coherence fiber-optic Fabry-Pérot sensing interferometers: comparative study
Publikacja -
Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers
PublikacjaIn this paper we investigated the response of a fiber-optic Fabry-Pérot sensing interferometer with thin ZnO layers deposited on the end faces of the optical fibers forming the cavity. Standard telecommunication single-mode optical fiber (SMF-28) segments were used with the thin ZnO layers deposited by Atomic Layer Deposition (ALD). Measurements were performed with the interferometer illuminated by two broadband sources operating...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublikacjaLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
Blood equivalent phantom vs whole human blood, a comparative study
PublikacjaPreclinical research of biomedical optoelectronic devices is often performed with the use of blood phantoms — a simpli¯ed physical model of blood. The aim of this study is the comparison and distinction between blood phantoms as well as whole human blood measurements. We show how the use of such phantoms may in°uence the incorrect interpretation of measured signal. On the other hand, we highlight how the use of blood phantoms enables...
-
Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
PublikacjaThe aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development...
-
Diamond-based protective layer for optical biosensors
PublikacjaOptical biosensors have become a powerful alternative to the conventional ways of measurement owing to their great properties, such as high sensitivity, high dynamic range, cost effectiveness and small size. Choice of an optical biosensor's materials is an important factor and impacts the quality of the obtained spectra. Examined biological objects are placed on a cover layer which may react with samples in a chemical, biological...
-
Experimental results of full scattering profile from finger tissue-like phantom
PublikacjaHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. We suggest a new optical method for sensing physiological tissue state, based on the collection of the ejected light at all exit angles, to receive the full scattering profile. We built a unique set-up for noninvasive encircled measurement. We use a laser, a photodetector and finger tissues-mimicking phantoms presenting different optical...
-
Introductory investigations of dermatologic diode laser with wavelengths 975 nm: clinical therapy of Recklinghausen disease and of hemangiomas
Publikacja -
Nanoparticle-free tissue-mimicking phantoms with intrinsic scattering
PublikacjaWe present an alternative to the conventional approach, phantoms without scattering nanoparticles, where scattering is achieved by the material itself: spherical cavities trapped in a silicone matrix. We describe the properties and fabrication of novel optical phantoms based on a silicone elastomer polydimethylsiloxane (PDMS) and glycerol mixture. Optical properties (absorption coefficient µa, reduced scattering coefficient µs',...
-
Optoelectronic investigation of nanodiamond interactions with human blood
PublikacjaWe present optoelectronic investigation of in vitro interactions of whole human blood with different nanodiamond biomarkers. Plasmo-chemical modifications of detonation nanodiamond particles gives the possibility for controlling their surface for biological applications. Optical investigations reveal the biological activity of nanodiamonds in blood dependent on its surface termination. We compare different types of nanodiamonds:...
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublikacjaRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...
Rok 2015
-
ALD thin ZnO layer as an active medium in a fiber-optic Fabry–Perot interferometer
Publikacja -
ALD thin ZnO layer as an active medium in a fiber-optic Fabry-Perot interferometer
Publikacja.
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublikacjaIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Detection of propofol concentrations in blood by Raman spectroscopy
PublikacjaIn this paper we present a proof-of-concept of a Raman spectroscopy-based approach for measuring the content of propofol, a common anesthesia drug, in whole human blood, and plasma, which is intended for use during clinical procedures. This method utilizes the Raman spectroscopy as a chemically–sensitive method for qualitative detection of the presence of a drug and a quantitative determination of its concentration. A number of...
-
Haemocompatibility Of Non-Functionalized And Plasmachemical Functionalized Detonation Nanodiamond Particles
PublikacjaThe purpose of this paper is to present the innovative design of microwave plasma system for modification of detonation nanodiamond particles (DNP) using a special rotating drum placed inside the reactor. Nanodiamond particles manufactured by detonation method reveal the biological activity depending on surface functionalization. Plasmachemical modification of detonation nanodiamond particles gives the possibility of controlling...
-
Investigation of photothermolysis therapy of human skin diseases using optical phantoms
PublikacjaDermatological diseases, such as neurofibroma (Recklinghausen disease) or hemangiomas can be efficiently treated using photothermolysis from laser irradiation. We have utilized a developed 975 nm fiber diode laser as a low-cost alternative over common Nd:YAG lasers. This paper describes the investigations of interaction of 975 nm diode laser radiation-pulses with optical skin phantoms which were designed and manufactured in our...
-
Measurements of fundamental properties of homogeneous tissue phantoms
PublikacjaWe present the optical measurement techniques used in human skin phantom studies. Their accuracy and the sources of errors in microscopic parameters’ estimation of the produced phantoms are described. We have produced optical phantoms for the purpose of simulating human skin tissue at the wavelength of 930 nm. Optical coherence tomography was used to measure the thickness and surface roughness and to detect the internal inhomogeneities....
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublikacjaExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
Optical properties of the chemotherapy drugs used in the central nervous system lymphoma therapy: monitoring drug delivery
PublikacjaOur aim is to optically monitor the delivery of the chemotherapy drugs for brain tumours, particularly used in the central nervous system (CNS) lymphoma therapy. In vivo monitoring would help to optimize the treatment and avoiding unnecessary medications. Moreover, it would be beneficial to be able to measure which of the multi-regimen drugs actually do penetrate and how well into the brain tissue. There exist several potential...
-
Raman spectroscopic investigation of blood and related materials
PublikacjaThis paper reports preliminary studies on use of Raman spectroscopy for investigation of blood. High quality blood spectra were recorded in-vitro with excitation wavelengths of 830 nm. Because of complex composition of the blood as well as by light attenuation and scattering in the tissues, spectra set up from wide, low-intensive Raman bands and intensive optical background. To get information about origin of bands in Raman spectra...
-
Selection of physiological parameters for optoelectronic system supporting behavioral therapy of autistic children
PublikacjaIn this article the procedure of selection of physiological parameters for optoelectronic system supporting behavioral therapy of autistic children is proposed. Authors designed and conducted an experiment in which a group of 30 health volunteers (16 females and 14 males) were examined. Under controlled conditions people were exposed to a stressful situation caused by the picture or sound (1kHz constant sound, which was gradually...
-
Sensing of anesthetic drugs in blood with Raman spectroscopy
PublikacjaA proof-of-concept study of a Raman spectroscopy-based approach for measuring the content of anesthesia drugs in blood is presented. Spectra of spiked blood from several patients exhibit prominent changes in regions associated with the drug.
-
Spectral reflectance modeling of ZnO layers made with Atomic Layer Deposition for application in optical fiber Fabry-Perot interferometric sensors
PublikacjaSuitability of zinc oxide (ZnO) layers grown using Atomic Layer Deposition for operation in optical-fiber extrinsic Fabry-Perot sensors is investigated using a numerical model. Reflectance spectra obtained using the developed model indicate that the application of these layers in optical-fiber extrinsic Fabry-Perot sensors is difficult as it may require a source whose spectrum width is about 300 nm. A series of ZnO layers grown...
-
System supporting behavioral therapy for children with autism
PublikacjaIn this paper, a system supporting behavioral therapy for autistic children is presented. The system consists of sensors network, base station and a brooch indicating person's emotional states. The system can be used to measure values of physiological parameters that are associated with changes in the emotional state. In the future, it can be useful to inform the autistic child and the therapist about the emotional state of the...
-
The use of low-coherence interferometer for sugar content determination
PublikacjaIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
Use of optical skin phantoms for preclinical evaluation of laser efficiency for skin lesion therapy
PublikacjaSkin lesions are commonly treated using laser heating. However, the introduction of new devices into clinical practice requires evaluation of their performance. This study presents the application of optical phantoms for assessment of a newly developed 975-nm pulsed diode laser system for dermatological purposes. Such phantoms closely mimic the absorption and scattering of real human skin (although not precisely in relation to...
Rok 2014
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublikacjaWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
Publikacja -
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublikacjaIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Wykorzystanie światłowodów w przemyśle elektroenergetycznym
PublikacjaAktualnie, eksploatacja czujników światłowodowych w elektroenergetyce nie jest rozwiązaniem powszechnie stosowanym, jednak wykorzystanie włókien światłowodowych w rozległych systemach sterowania i nadzoru, jakim jest np. Krajowy System Elektroenergetyczny, jest już standardem. Połączenie transmisji światłowodowej z techniką cyfrową wpłynęło na niezawodność łączy technologicznych, co spowodowało wzrost niezawodności i bezpieczeństwa...
Rok 2013
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublikacjaIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Metody matematyczne syntezowania źródeł optycznych do interferometrów niskokoherentnych dla zastosowa biomedycznych
PublikacjaW pracy przedstawiono mozliwosci wykorzystania metod matematycznych w układach interferometrii niskokoherentnej do zastosowan biomedycznych. Metody takie sa wykorzystywane na kazdym z etapów realizacji układów: projektowania poszczególnych elementów, obróbki danych pomiarowych oraz w trakcie walidacji techniki pomiarowej. W pracy przedstawiono mozliwosci optymalizacji parametrów metrologicznych interferometrów niskokoherentnych...
-
Optimization of a Fabry-Perot Sensing Interferometer design for an optical fiber sensor of hematocrit level
PublikacjaContinuous measurement of the hemato crit level in blo o d can p otentially b e p erformed using optical bre sensors. The FabryPerot interferometric sensors are a promising candidate in this application. The most imp ortant step in the design of the sensor is design of the sensing interferometer. Adequate cavity length and high interference contrast are two most imp ortant requirements in this application. The design metho d of...
-
Spectroscopic wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement is presented. The sensor, designed and developed by authors, consists of a spectroscopic set-up and a microcontroller. The work of the sensor is based on measurement of intensity of two selected spectral bands. Tests confirmed the ability of the sensor to determine the hematocrit level with appropriate measurement accuracy. Measurement results can be transmitted via wireless module to...
Rok 2012
-
Spectroscopic and wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.
-
Spectroscopic and Wireless Sensor of Hematocrit Level
Publikacja -
Wireless data transmission for fiber optical sensor system
PublikacjaW artykule opisano możliwość wykorzystania bezprzewodowego systemu transmisji danych do transmisji sygnałów z czujników światłowodowych.
Rok 2011
-
Application of spectroscopy to the measurement of blood parameters
PublikacjaSpectroscopy is the study of formation and interpretation of the spectra arising from the interactions of all types of radiation on matter, understood as a collection of atoms and molecules. This is a very important department of optics which gives us many opportunities to measure various parameters such as material blood parameters. Among the diseases that are associated significantly with changes in rheological properties of...
-
Low-coherence Fiber-Optic Interferometric Sensors
PublikacjaW artykule porównano parametry metrologiczne zrealizowanych niskokoherencyjnych czujników światłowodowych wykorzystujących interferometr Michelsona oraz Fabry-Perot.
-
Low-Coherence Fibre-Optic Interferometric Sensors
Publikacja
wyświetlono 8256 razy