Filtry
wszystkich: 278
wybranych: 192
Filtry wybranego katalogu
Wyniki wyszukiwania dla: pulse-frequency
-
High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study
PublikacjaIntroduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...
-
Reliability of Pulse Measurements in Videoplethysmography
PublikacjaReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
Increased inspiratory resistance affects the dynamic relationship between blood pressure changes and subarachnoid space width oscillations
PublikacjaBackground and objective Respiration is known to affect cerebrospinal fluid (CSF) movement. We hypothesised that increased inspiratory resistance would affect the dynamic relationship between blood pressure (BP) changes and subarachnoid space width (SAS) oscillations. Methods Experiments were performed in a group of 20 healthy volunteers undergoing controlled intermittent Mueller Manoeuvres (the key characteristic of the procedure...
-
High Performance Control of AC Drives with Matlab/ Simulink
PublikacjaExplore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...
-
Analysis of the Accuracy of Pulse Estimation Using Smart Watches
PublikacjaThe purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...
-
Directed electromagnetic pulse dynamics: projecting operators method
PublikacjaIn this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...
-
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
PublikacjaIn this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...
-
Time domain model of the resonance-based electromagnetic pulses emission system
PublikacjaIn the literature, the emission properties of the electromagnetic field pulse systems based on high voltage antennas (HVR) have been widely described. In order to increase the emission efficiency by extending duration and increasing amplitude of the impulse it is possible to use a resonance system tuned to the parameters of the signal shaped in the pulse forming circuit. The synthesis of a time-domain simulation model of a complex...
-
The Influence of Laser Alloying of Ti13Nb13Zr on Surface Topography and Properties
PublikacjaThe laser alloying is a continually developing surface treatment because of its significant and specific structuration of a surface. In particular, it is applied for Ti alloys, being now the most essential biomaterials` group for load-bearing implants. The present research was performed on the Ti13Nb13Zr alloy subject to laser modification in order to determine the treatment effects on surface topography and its some mechanical...
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublikacjaThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublikacjaThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
A robust 18-pulse diode rectifier with coupled reactors
PublikacjaThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Estimating Intercept Range of Silent Sonar
PublikacjaWhen used in military application, sonars should ensure secretiveness. There is some evidence suggesting that silent sonars have a significant advantage over pulse sonars in the respect. If improved, the secretiveness of silent sonar translates into the distance over witch its soundings signal are detected by intercept sonars. The article gives estimated distances for far, medium, and short range sonars operating in the oceans...
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublikacjaAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
Measuring Pulse Rate with a Webcam
PublikacjaIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
Remote Estimation of Video-Based Vital Signs in Emotion Invocation Studies
PublikacjaAbstract— The goal of this study is to examine the influence of various imitated and video invoked emotions on the vital signs (respiratory and pulse rates). We also perform an analysis of the possibility to extract signals from sequences acquired with cost-effective cameras. The preliminary results show that the respiratory rate allows for better separation of some emotions than the pulse rate, yet this relation highly depends...
-
Directed pulse dynamics
PublikacjaIntroducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublikacjaIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Propagation of acoustic pulses in some fluids with yield stress
PublikacjaThis study is devoted to the derivation of approximate equations governing acoustic pulses in flows with yieldstress, including some time-dependent flows with a slow dependence on time of yield stress and apparent viscosity. Themodeling of yield stress and apparent viscosity in the vicinity of a zero deformation rate allows us to consider a thixotropicfluid as a Bingham plastic with coefficients that are dependent on time. The...
-
Ultrashort Opposite Directed Pulses Dynamics with Kerr Effect and Polarization Account
PublikacjaWe present the application of projection operator methods to solving the problem of the propagation and interaction of short optical pulses of different polarizations and directions in a nonlinear dispersive medium. We restrict ourselves by the caseof one-dimensional theory, taking into account material dispersion and Kerr nonlinearity. The construction of operators is delivered in two variants: for the Cauchy problem and for the...
-
New Architecture of Solid-State High-Voltage Pulse Generators
PublikacjaThe application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublikacjaIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Control strategy for the multilevel cascaded H-bridge converter
PublikacjaThe paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.
-
A new duty cycles calculation method in pulse width modulation for direct matrix converters based on the shape function concept
PublikacjaPaper presents a new approach to duty cycle calculation in pulse width modulation for direct matrix converters. The essence of the proposed method is the use of elementary shape function of finite element. The algorithm for calculating the duty cycles was reduced to simple operations on the coordinates of input and output voltage vectors without trigonometric functions.
-
Enhanced Remote Control Providing Medical Functionalities
PublikacjaThis paper presents the enhanced remote control and its role in pervasive healthcare in the home. The device was equipped with health-related measurement modules and a message-processing unit. Preliminary results are presented for monitoring of a pulse, hand tremors, grip forces, and for self evaluation procedures. The interaction of the device with the smart environment is presented and discussed.
-
Pulse-Width Modulation Template for Five-Level Switch-Clamped H-Bridge-Based Cascaded Multilevel Inverter
PublikacjaThis article presents a carrier-based pulse-width modulation (PWM) template for a 5-level, H bridge-based cascaded multilevel inverter (MLI). The developed control concept generates adequate modulation template for this inverter topology wherein a sinusoidal modulating waveform is modified to fit in a single triangular carrier signal range. With this modulation approach, classical multiplicity and synchronization of the triangular...
-
The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard
PublikacjaIn this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublikacjaThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Electrodeposited Biocoatings, Their Properties and Fabrication Technologies: A Review
PublikacjaCoatings deposited under an electric field are applied for the surface modification of biomaterials. This review is aimed to characterize the state-of-art in this area with an emphasis on the advantages and disadvantages of used methods, process determinants, and properties of coatings. Over 170 articles, published mainly during the last ten years, were chosen, and reviewed as the most representative. The most recent developments...
-
Studying the Effect of Working Conditions on WEDM Machining Performance of Super Alloy Inconel 617
PublikacjaWire electrical discharge machining (WEDM) has been for many years a precise and efficient non-conventional manufacturing solution in various industrial applications, mostly involving the use of hard-to machine materials like, among other, the Inconel super alloys. The focus of the present study is on exploring the effect of selected control parameters, including pulse duration, pulse-off time and the dielectric flow pressure on...
-
Radar time budget optimization subject to angle accuracy constraint via cognitive approach
PublikacjaThe problem of minimizing dwell time in multifunction phased array radar is considered. Target of interest is assumed to fluctuate according to a generalization of Swerling family and the parameters of fluctuation model are assumed to be known. The a'priori position of the target is uncertain. Optimization, whose variables include pulse count and array transmit beampattern, is carried out subject to achieving a desired accuracy...
-
Gate Driver with Overcurrent Protection Circuit for GaN Transistors
PublikacjaThe improvement of the gate driver for GaN transistor is presented in this paper. The proposed topology contains the overcurrent protectionwith the two-stage turning off and independent control of turn on and off time of the GaN transistor. The operation of driver and its application in thehalf-bridge converter are described using both simulation and prototype measurements. The overcurrent protection was tested in Double Pulse...
-
Eksperymentalna analiza modalna stojanów silników indukcyjnych
PublikacjaW artykule zaprezentowano technikę pomiarów i wyniki obliczeń postaci drgań własnych badanego stojana silnika indukcyjnego klatkowego. Przedstawiono również teoretyczne podstawy zastosowanej techniki obliczeniowej. Jako narzędzie akwizycji danych wykorzystano pomiarowy system PULSE firmy Brüel&Kjær, a w celu przeprowadzenia koniecznych obliczeń oraz wizualizacji wyników wykorzystano środowisko Matlab.
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublikacjaA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublikacjaA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions
PublikacjaAbstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...
-
Compact and Integrated High-Power Pulse Generation and Forming System
PublikacjaThis paper presents comprehensive analytical, numerical and experimental research of the compact and integrated high-power pulse generation and forming system based on the flux compression generator and the electro-explosive forming fuse. The paper includes the analysis of the presented solution, starting from the individual components studies, i.e., the separate flux compression generator tests in field conditions and the forming...
-
Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
PublikacjaTwo different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...
-
Analysis of the possibility of creep damage detection in T24 heat resistant steel with the help of magnetic nondestestructive testing methods
PublikacjaThe paper presents the result of an analysis of applicability of various electromagnetic methods of nondestructive evaluation for creep damage detection in a novel heat resistant steel - T24 grade. Two sample sets, cut out from membrane wall tubes, were investigated – the as-delivered one and another exploited for 36,000 h in a power plant. There are described results of magnetic hysteresis loops B(H), Barkhausen noise (BN) and...
-
FFT spectrum based matching algorithm for activedynamic thermography
PublikacjaIn Active Dynamic thermography (ADT) sequences of consecutive temperature distributions are analyzed. In biomedical applications of ADT, the problems of a patient's movements in front of a thermal camera should be eliminated before data analysis. Complete mechanical stabilization of the patients is impossible due to natural voluntary and involuntary moves caused by pulse breathing, etc. This paper presents a simple and efficient...
-
Application of the laser diode with central wavelength 975 nm for the therapy of neurofibroma and hemangiomas
PublikacjaThis paper presents newly developed dermatological laser (with central wavelength 975 nm) for application in therapies requiring deep penetration of tissue, e.g. cutaneous (dermal) neurofibroma (Recklinghausen disease) and hemangiomas. This laser can work either in pulse or continues wave mode. Laser radiation is transmitted toward the application region by optical fiber with a diameter of 0.6 mm. The compact design of the laser...
-
Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
PublikacjaA non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...
-
DC-link voltage balancing in cascaded H-Bridge converters
PublikacjaIn the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublikacjaIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
A New Three-Dimensional Space Vector Modulation for Multilevel Four-Leg Converters Based on the Shape Functions of Tetrahedral Element
PublikacjaThe paper proposes a new three-dimensional space vector pulse-width modulation (3D-SVPWM) algorithm for multilevel four-leg converters. The proposed PWM duty cycle calculation is based on the shape functions of the threedimensional tetrahedral finite elements. The algorithm ensures synthesis of accurate and undistorted output voltages even under significant imbalance or ripple in the DC-link voltages. At the same time, the algorithm...
-
Four Level Diode-Clamped Back-To-Back Converter with Active DC Link Voltage Control
PublikacjaThis article presents the design and control of 4L-DC back-to-back converter. To solve the DC link voltage balancing problem in four-level converter a new three-level double chopper topology based on PO-PWM modulation was designed and successfully tested. Also, the paper describes two phase space vector pulse width modulation 2P-SVPWM based on the shape function of finite elements. The control structure with modified Dead-Beat...
-
Determination of Antioxidant Activity of Vitamin C by Voltammetric Methods
PublikacjaVoltammetric methods—cyclic (CV) and differential pulse voltammetry (DPV) are considered the most appropriate way to evaluate antioxidant activity of redox active compounds. They provide information about both mechanism and kinetics of electrochemical oxidation of antioxidants as well as their physical and chemical properties such as the redox potential or the number of electrons transferred. These methods are helpful for understanding...
-
Accuracy of the discrete Green's function computations
PublikacjaThis paper discusses the accuracy of the discrete Green's function (DGF) computations. Recently closed-form expression of the DGF and its efficient numerical implementation were presented which facilitate the DGF applications in FDTD simulations of radiation and scattering problems. By carefully comparing the DGF results to those of the FDTD simulation, one can make conclusions about the range of the applicability of the DGF for...
-
Long-Term Measurement of Physiological Parameters – Child Dataset
PublikacjaThe dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...
-
Machine learning-based prediction of seismic limit-state capacity of steel moment-resisting frames considering soil-structure interaction
PublikacjaRegarding the unpredictable and complex nature of seismic excitations, there is a need for vulnerability assessment of newly constructed or existing structures. Predicting the seismic limit-state capacity of steel Moment-Resisting Frames (MRFs) can help designers to have a preliminary estimation and improve their views about the seismic performance of the designed structure. This study improved data-driven decision techniques in...