Wyniki wyszukiwania dla: IMPEDANCE MONITORING
-
Impedance monitoring of fuel cell stacks
PublikacjaThis paper presents an innovative, electrochemical impedance method for monitoring of electrochemical behaviour of a multi-cell, direct methanol fuel cell (DMFC) device. This method not only provides classical voltage changes at successive cells but also allows their detailed impedance behaviour to be presented. Impedance characteristics of individual cells within a fuel cell stack (depending on actual operating conditions) are...
-
Impedance monitoring of fuel cell stacks
Publikacja -
On-line Impedance Monitoring of Direct Methanol Fuel Cell
PublikacjaW niniejszej pracy została przedstawiona technika badawcza Dynamiczna Elektrochemiczna Spektroskopia Impedancyjna w obszarze badań ogniw paliwowych. Obiektem badań było ogniwo paliwowe zasilane bezpośrednio metanolem. Badano on-line wpływ zmian warunków pracy na globalną impedancję ogniwa. Podczas pomiarów zmianie ulegała temperatura, natężenia przepływu utleniacza oraz obciążenie.
-
Novel application of dynamic electrochemical impedance monitoring to a cataphoretic coating process
PublikacjaThe paper presents a novel method of on-line impedance monitoring of cataphoretic coating application process. Utilization of dynamic electrochemical impedance spectroscopy (DEIS) overcame the fundamental problem connected with non-stationarity of the aforementioned coating deposition process, which eliminates classical impedance spectroscopy technique from a real-time description of cataphoresis. The paper illustrates selected examples...
-
Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes
PublikacjaThe most common method of determination of cavitation erosion resistance as well as the magnitude of erosion-corrosion synergistic interaction is based on the weight loss measurements. Nondestructive characterization of installations elements is in most cases impossible to perform. Also, such a measurement does not include local types of failure or alteration of operating conditions. There is an urge to elaborate a method for monitoring...
-
Impedance monitoring of carbon steel cavitation erosion under the influence of corrosive factors
PublikacjaW pracy przedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej oraz funkcję ubytku masy powszechnie stosowaną do oceny odporności kawitacyjnej materiałów. Oszacowanie stopnia degradacji powierzchni, a także wpływu erozji na odporność korozyjną jest możliwe po zastosowaniu odpowiedniego elektrycznego...
-
Impedance monitoring of corrosion degradation of plasma electrolytic oxidation coatings (PEO) on magnesium alloy
PublikacjaImpedance technique based on continuous multisinusoidal current perturbation was used to explain degradation process of plasma electrolytic oxidation coatings (PEO) on magnesium alloy. An obtained impedance spectrum was fitted by electrical equivalent circuit to describe properties of conversion layer on magnesium alloy. Additionally, galvanostatic mode maintained during experiment, with DC current equal to zero, allowed to achieve...
-
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublikacjaThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublikacjaA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublikacjaW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
-
Monitoring of CRT by means of impedance multiple measurements - simulation studies
PublikacjaCardiac resynchronization therapy (CRT) is a very promising treatment for patients with congestive heart failure. An Impedance Cardiography (ICG) is used for evaluation of heart mechanical activity. A simulation study with the use of a FEM model was performed. The developed realistic model of the thorax, based on CT data obtained from examination of a 68-year-old man, consisted of 212 000 tetrahedral elements. Different configurations...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublikacjaThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublikacjaThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery
Publikacja -
The impedance method of monitoring the degradation of rubber linings in applications where progressive deterioration is the predominant failure mechanism
Publikacja -
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublikacjaThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
PublikacjaDynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
The influence of dynamic load changes on temporary impedance in hydrogen fuel cells, selection and validation of the electrical equivalent circuit
PublikacjaTo achieve optimal performance of a fuel cell, a reliable monitoring and diagnostic method is required. The currently utilized methods give limited information or they are impossible to use under dynamic working conditions. To obtain comprehensive information about the fuel cell operation we utilized novel dynamic electrochemical impedance spectroscopy. Impedance measurements in dynamic mode were performed on a hydrogen fuel cell,...
-
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublikacjaWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...
-
The impedance of hydrogen oxidation reaction in a proton exchange membrane fuel cell in the presence of carbon monoxide in hydrogen stream
PublikacjaEvaluation of performance of a proton exchange membrane fuel cell, which is affected by carbon monoxide that pollutes the hydrogen stream, was presented. This influence was studied for carbon monoxide concentration of 125–325 ppb, which are close to values specified in ISO 14687:2019 standard. Performed studies provided crucial information for further development of fuel cell as an energy source for automotive application. Impedance...
-
Determination of pitting corrosion stage of stainless steel by galvanodynamic impedance spectroscopy
PublikacjaThis paper investigates the methodology for differentiation of multistep process of pitting corrosion of AISI 304 stainless steel in the environment of iron (III) chloride. Measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Application of this methodology allowed monitoring of natural corrosion process without external current (IDC = 0A) nor potential perturbation of the system. Applied...
-
Instantaneous Impedance Analysis of Non-Stationary Corrosion Process: a Case Study of Carbon Steel in 1M HCl
PublikacjaThe paper concerns the problem of evaluation of stationarity of carbon steel corrosion in 1M HCl. Comparison of corrosion rate with addition of corrosion inhibitor to the reference measurement is the most often used way of evaluating inhibitor efficiency. Such an approach is valid only if corrosion rate is a stationary process. Two complementary techniques were used simultaneously: volumetric analysis of evolved hydrogen and instantaneous...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublikacjaThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Investigation of the electrochemical behaviour of AA1050 aluminium alloy in aqueous alkaline solutions using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaThe paper presents the electrochemical behaviour of aluminium alloy AA1050 in aqueous alkaline media in the pH range 14–8.5. Electrochemical study was applied in order to obtain comprehensive information on the mechanism and kinetics of the process of anodic dissolution of aluminium, supplemented by monitoring of surface topography using an electron microscope. The corrosion rate of AA1050 increases with increasing concentration...
-
Multisine impedimetric monitoring with an in-depth distribution of relaxation times analysis of WE43 and AZ31 magnesium alloys corrosion
PublikacjaThis research aims to develop and utilize an impedance-based tool for monitoring non-stationary electrochemical processes, coupling the multisinusoidal perturbation signal approach and distribution of relaxation times (DRT) analysis for the first time. The approach was used to distinguish independent processes occurring at the surface of AZ31 and WE43 Mg alloys undergoing corrosion in Hank’s Balanced Salt Solution at 37 °C. We...
-
Application of quartz crystal microbalance and dynamic impedance spectroscopy to the study of copper corrosion inhibitors
PublikacjaThe study investigates the application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) and Electrochemical Quartz Crystal Microbalance (EQCM) techniques to examine the corrosion inhibition of copper by Benzotriazole and Sodium Folate in a 0.1 M NaCl solution. DEIS, an advanced version of Electrochemical Impedance Spectroscopy (EIS), allows for real-time monitoring of non-stationary electrochemical systems,...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublikacjaThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Application of Galvanostatic Non-Linear Impedance Spectroscopy to the Analysis of Metallic Material Degradation
PublikacjaThis study presents a novel application of Non-Linear Electrochemical Impedance Spectroscopy (NLEIS) in galvanostatic mode for the rapid, non-destructive assessment of metal degradation. By using galvanostatic mode instead of traditional potentiostatic methods, polarization-related challenges are mitigated, enabling more accurate and reliable analysis. The technique allows for the determination of corrosion rates (corrosion current)...
-
The contactless method of chip-to-chip high-speed data transmission monitoring
PublikacjaThis paper presents a technique of decoupling differential signals transmitted in a pair of microstrip lines on a printed circuit board (PCB), using dedicated coupler for high speed data transmission monitoring in chip-to-chip interconnections. The coupler used for signal probing is overlayed on the pair of microstrip lines under test, and provides a signal to the next blocks of the measurement system without disturbing transmission...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublikacjaThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
A Wearable System Developed to Monitor People Suffering from Vasovagal Syncope
PublikacjaA wearable system for monitoring non-invasively signals invaluable when examining person suffering from vasovagal syncope is presented in the paper. Following signals are continuously recorded: electrocardiogram, photopletysmogram, impedance cardiogram and electrodermal resistance.
-
Study on surface termination of boron-doped diamond electrodes under anodic polarization in H2SO4 by means of dynamic impedance technique
PublikacjaAnodic oxidation is a popular way to modify termination bonds at boron doped diamond electrodes altering their electrochemical and physicochemical properties. Our studies, performed with dynamic electrochemical impedance spectroscopy technique, supported with X-ray photoelectron spectroscopy and ellipsometry analysis prove its utility in continuous on-line monitoring of impedance changes on the electrode surface under polarization...
-
The Impact of Crushed Rock Spoil on Pitting Corrosion of Selected Stainless Steel
PublikacjaThe paper presents the results of the pitting resistance investigations of selected stainless steels in the chloride environment and the simultaneous impact of erosive factors using the cyclic polarization technique. Additionally, using electrochemical techniques, ie: electrochemical impedance spectroscopy (EIS) and measurement of corrosion potential, the behavior of the passive layer of selected stainless steels in the environment...
-
The non-invasive evaluation of heart function in patients with an acute myocardial infarction: The role of impedance cardiography
PublikacjaBackground: The purpose of this study was to analyze hemodynamic changes in patients treated with percutaneous coronary intervention (PCI) at an early stage of acute myocardial infarction (AMI) and at one-month follow-up. Methods: Patients with AMI (n = 27) who underwent PCI were analyzed using impedance cardiography (ICG). ICG data were collected continuously (beat by beat) during the whole PCI procedure and thereafter at every...
-
A novel sensor for measuring temperature profile during the thermoablation
PublikacjaAbstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...
-
Exploring Mechanism of Corrosion Inhibition of WE43 and AZ31 Alloys by Aqueous Molybdate in Hank’s Solution by Multisine Impedimetric Monitoring
PublikacjaThe concept of utilizing multisine dynamic electrochemical impedance spectroscopy to monitor effectiveness of a model molybdate inhibitor for AZ31 and WE43 Mg alloys is proposed. The corrosion kinetics and instantaneous values of inhibition efficiency (IE) of molybdate at concentrations up to 150 mM were examined. The inhibitor provides inhibition in Hank’s solution at concentrations starting from ca. 25 mM, with the IE of about...
-
Assessment of copper surface coverage with corrosion inhibitor using AFM-based local electrical measurements
PublikacjaThe paper presents a new method of assessment of metal surface coverage with corrosion inhibitor and thus of inhibitor protective performance. It is based on the atomic force microscopy measurement performed in a contact mode. Apart from topography images the proposed approach allows acquisition of local DC maps and local electrical impedance spectra via application of DC bias voltage or AC perturbation signal between the conductive...
-
Effect of Thermal Shock During Legionella Bacteria Removal on the Corrosion Properties of Zinc-Coated Steel Pipes
PublikacjaThe purpose of this investigation was to conduct the failure analysis of a water-supply system made from zinc-coated steel. The observed corrosion process had an intense and complex character. The brownish deposits and perforations were present after 2-3 years of exploitation. The electrochemical study based on the Tafel polarization, corrosion potential monitoring, and electrochemical impedance spectroscopy together with microscopic...
-
Assessment of cardiovascular risk in assisted living
PublikacjaWady i choroby układu krążenia są jedną z podstawowych przyczyn problemów zdrowotnych oraz przyczyn śmierci. Wczesne ich wykrycie jest szczególnie cenne jako, że może zapobiec przez poważnymi incydentami (np. zawał, udar, itp.). W artykule przedstawiono nasobny system pomiarowy integrujący wiele pomiarów przydatnych do oceny problemów kardiologicznych.Disorders of the heart and blood vessels are the leading cause of health problems...
-
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublikacjaThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...
-
Phospholipid-functionalized gold electrode for cellular membrane interface studies - interactions between DMPC bilayer and human cystatin C
PublikacjaThis work describes the electrochemical studies on the interactions between V57G mutant of human cystatin C (hCC V57G) and membrane bilayer immobilized on the surface of a gold electrode. The electrode was modified with 6-mercaptohexan-1-ol (MCH) and 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC). DMPC was used as a membrane mimetic for monitoring electrochemical changes resulting from the interactions between the functionalized...
-
Discriminating macromolecular interactions based on an impedimetric fingerprint supported by multivariate data analysis for rapid and label-free Escherichia coli recognition in human urine
PublikacjaThis manuscript presents a novel approach to address the challenges of electrode fouling and highly complex electrode nanoarchitecture, which are primary concerns for biosensors operating in real environments. The proposed approach utilizes multiparametric impedance discriminant analysis (MIDA) to obtain a fingerprint of the macromolecular interactions on flat glassy carbon surfaces, achieved through self-organized, drop-cast,...
-
A novel dual-band rectifier circuit with enhanced bandwidth for RF energy harvesting applications
PublikacjaIn recent years, a rapid development of low-power sensor networks, enabling machine-to-machine communication in applications such as environmental monitoring, has been observed. Contemporary sensors are normally supplied by an external power source, typically in a form of a battery, which limits their lifespan and increases the maintenance costs. This problem can be addressed by harvesting and converting ambient RF energy into...
-
Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements
PublikacjaWe proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...
-
Variable-Fidelity Simulation Models and Sparse Gradient Updates for Cost-Efficient Optimization of Compact Antenna Input Characteristics
PublikacjaDesign of antennas for the Internet of Things (IoT) applications requires taking into account several performance figures, both electrical (e.g., impedance matching) and field (gain, radiation pattern), but also physical constraints, primarily concerning size limitation. Fulfillment of stringent specifications necessitates the development of topologically complex structures described by a large number of geometry parameters that...
-
Chemical-Assisted Mechanical Lapping of Thin Boron-Doped Diamond Films: A Fast Route Toward High Electrochemical Performance for Sensing Devices
PublikacjaThere is an urgent need for an effective and economically viable increase in electrochemical performance of boron-doped diamond (BDD) electrodes that are used in sensing and electrocatalytic applications. Specifically, one must take into consideration the electrode heterogeneity due to nonhomogenous boron-dopant distribution and the removal of sp2 carbon impurities saturating the electrode, without interference in material integrity....
-
Application of Wavelet Transform and Fractal Analysis for Esophageal pH-Metry to Determine a New Method to Diagnose Gastroesophageal Reflux Disease
PublikacjaIn this paper, a new method for analysing gastroesophageal reflux disease (GERD) is shown. This novel method uses wavelet transform (WT) and wavelet-based fractal analysis (WBFA) on esophageal pH-metry measurements. The esophageal pH-metry is an important diagnostic tool supporting the physician’s work in diagnosing some forms of reflux diseases. Interpreting the results of 24-h pH-metry monitoring is time-consuming, and the conclusions...
-
Impedance of cation-coupled electron transfer reaction: Theoretical description of one pathway process
PublikacjaIt has been assumed that cation electron coupled charge transfer can be conducted in accordance with two mutually coupled reactions. Using a differential method an expression was introduced which describes the impedance of a cation electron coupled transfer reaction. Also, an electrical equivalent circuit has been defined. The total faradaic impedance is the sum of electron transfer impedance and cation transfer impedance. Issues...
-
Polynomial analysis as a new way of describing dynamic impedance spectra – Differential and relative impedance spectra
PublikacjaModel measurements of an equivalent electrical system were carried out using the technique of Dynamic Electrochemical Impedance Spectroscopy. The measurement took the form of potentiodynamic changes imposed on the tested system. Using the possibility of continuous impedance measurements, an attempt was made to develop an original and innovative method of analyzing impedance spectrograms, which is termed polynomial analysis. As...
-
Fast High-Impedance Spectroscopy Method Using SINC Signal Excitation
PublikacjaIn this paper the method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 Gohm) is evaluated by means of simulation and practical experiment. The method is based on excitation of an object with a sinc signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance spectrum is obtained with use of continuous Fourier transform...