Filtry
wszystkich: 1278
wybranych: 892
Wyniki wyszukiwania dla: amperometric%20sensors
-
Identification of defected sensors in an array of amperometric gas sensors
PublikacjaPurpose Amperometric gas sensors are commonly used in air quality monitoring in long-term measurements. Baseline shift of sensor responses and power failure may occur over time, which is an obstacle for reliable operation of the entire system. The purpose of this study is to check the possibility of using PCA method to detect defected samples, identify faulty sensor and correct the responses of the sensor identified as faulty. Design/methodology/approach In...
-
Application of Ionic Liquids in Amperometric Gas Sensors
PublikacjaThis article presents an analysis of available literature data on metrological parameters of the amperometric gas sensors containing ionic liquids as an electrolyte. Four mechanism types of signal generation in amperometric sensors with ionic liquid are described. Moreover, this article describes the influence of selected physico-chemical properties of the ionic liquids on the metrological parameters of these sensors. Some metrological...
-
Selectivity of amperometric gas sensors in multicomponent gas mixtures
PublikacjaIn recent years smog and poor air quality became a growing environmental problem. There is a need to continuously monitor the quality of air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, a selectivity of the six amperometric gas sensors is being investigated. Calibration of sensors has been performed in order to find a correlation between concentration...
-
Gas mixtures recognition using an array of amperometric gas sensors with drifting or faulty sensors
PublikacjaIn this study, the possibility of using selected methods for diagnostics of performance of matrix composed with six amperometric electrochemical gas sensors is investigated. Measurements of sensor responses in selected concentrations of single toxic gases or gas mixtures were performed and were repeated over time to show sensor drift. Additionally, the studies on the sensors’ drift were performed. The drift has been recognized...
-
Amperometric gas sensors with elektrodes chemically deposited on Nafion membrane
PublikacjaW pracy przedstawiono opis metod otrzymywania elektrod pracujących w czujnikach amperometrycznych gazów z elektrolitem ciekłym. Zaprezentowano metody chemiczne takie jak: metoda impregnacji-redukcji i metoda Takenaka-Torikai. Przedstawiono przegląd konstrukcji czujnikowych gazowych z elektrodami tego typu.
-
Limited selectivity of amperometric gas sensors operating in multicomponent gas mixtures and methods of selectivity improvement
PublikacjaIn recent years, smog and poor air quality have became a growing environmental problem. There is a need to continuously monitor the quality of the air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, the selectivity of six amperometric gas sensors is investigated. First, the sensors were calibrated in order to find a correlation between the concentration...
-
Selectivity of amperometric sulfur dioxide sensor.
PublikacjaW pracy przedstawiono wartości współczynników selektywności amperometrycznego czujnika ditlenku siarki względem siarkowodoru. Obliczenia wykonane zostały w oparciu o krzywe kalibracyjne wyznaczone dla zaprezentowanego wcześniej przez nas amperometrycznego czujnika ditlenku siarki. Analiza krzywych kalibracyjnych pod względem czułości oznaczenia oraz analiza wartości amperometrycznych współczynników selektywności odgrywa dużą pomocniczą...
-
Analytical characteristics of a new amperometric sulfur dioxide sensor
PublikacjaZaprojektowano i skonstruowano wyposażony w układ trójelektrodowy amperometryczny czujnik ditlenku siarki. Elektroda pracująca czujnika była napylona bezpośrednio na powierzchnię membrany. Zbadano charakterystyki czujnika z membranami z mikroporowatego Teflonu oraz Nafionu. Porównano parametry statyczne i dynamiczne tych czujników wypełnionych roztworami elektrolitów wewnętrznych, zawierających dodatek dimetylosulfotlenku.
-
Influence of Humidity on Parameters of Amperometric Sensor with Nafion Membrane
PublikacjaPrzedstawiono wyniki badań wpływu umiarkowanych i wysokich wilgotności powietrza na sygnał, czułość i czas odpowiedzi prototypowego czujnika ditlenku siarki ze złotą elektrodą pracującą, próżniowo napyloną na powierzchnię membrany nafionowej. Zaprezentowano także wyniki badań impedancyjnych w zakresie potencjałów, w którym mechanizm utleniania ditlenku siarki jest kontrolowany aktywacyjnie i dyfuzyjnie. Parametry odpowiadające...
-
Influence of aprotic solvent on selectivity of an amperometric sensor with nafion membrane
PublikacjaW publikacji przedstawiono rezultaty badań dotyczące selektywności amperometrycznego czujnika ditlenku siarki z membraną nafionową wobec tlenku węgla i dwutlenku azotu jako interferentów. Zostały porównane współczynniki selektywności dla czujników wypełnionych roztworami elektrolitów zawierających wodne roztwory kwasu siarkowego i różne ilości rozpuszczalnika aprotycznego - dimetylosulfotlenku.
-
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublikacjaSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
Influence of aprotic solvent on a signal of an amperometric sensor with Nafion membrane
PublikacjaW pracy przedstawiono wyniki badań charakterystyk analitycznych amperometrycznego czujnika ditlenku siarki wyposażonego w mebranę nafionową i wypełnionego roztworami elektrolitów o różnej zawartości dimetylosulfotlenku. Ocenie poddany został wpływ zawartości DMSO w roztworze elektrolitu wewnętrznego czujnika oraz prędkości przepływu gazu na czułość czujnika i czas odpowiedzi na zmiany stężenia ditlenku siarki.
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublikacjaThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublikacjaIn this work amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode will be presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been investigated.
-
Construction and investigation of SO2 amperometric sensor with a solid polymer electrolyte membrane
Publikacjan this paper a sensor for detection of the sulphur dioxide based on three electrode cell configuration with a liquid electrolyte, a mercury sulphate reference electrode and a solid polymer electrolyte working electrode is presented. Working elec- trode was obtained by using Takenaka-Torikai chemical deposi- tion method by precipitation of Au particles into the pores of the Nafion membrane. Sensors characteristics measurements were...
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublikacjaIn this work investigation of an amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode properties is presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been studied.
-
Metrological parameters of sulphur dioxide amperometric sensor containing addition of aprotic solvents
PublikacjaW publikacji zaprezentowano wyniki badań nad dodatku rozpuszczalnika aprotycznego do roztworu elektrolitu wewnętrznego czujnika na parametry metrologiczne prototypowego czujnika ditlenku siarki z membraną nafionową. Porównywano właściwości pięciu czujników różniących się składem elektrolitu. W każdym przypadku elektroda pracująca wykonana była ze złota, próżniowo napylonego na powierzchnię membrany. Roztwory elektrolitów zawierały...
-
Determination of cyanide in urine and saliva samples by ion chromatography with pulsed amperometric detection
PublikacjaCommonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes. It naturally occurs in plant seeds as a cyanogenic glycosides. Another relatively common mode of cyanide exposure is inhalation of environmental tobacco smoke. This study concerns importance to determine cyanide ion in human biological samples. Urine and saliva samples were collected healthy volunteers exposed to tobacco...
-
Ion Chromatography with Pulsed Amperometric Detection for Determining Cyanide in Urine and Meconium Samples
PublikacjaThe parents’ addictions and eating habits have a significant influence on the child’s growth. The first stool of a newborn baby provides a large amount of information about xenobiotics transmitted by the mother’s body. The analytical technique used in the study is ion chromatography with pulsed amperometric detection (IC-PAD). The biological samples, which were obtained from women staying in a maternity ward and their partners,...
-
Determination of cyanide ion in urine samples using ion chromatography with pulsed amperometric detection.
PublikacjaCyanides are widely applied in industrial activity, including gold and silver mining and the production of organic chemicals. HCN is also formed directly from fossil fuel combustion sources from gasoline and diesel vehicles. In natural environment, in plants seeds for example an apple seed, it exists as a cyanogenic glycosides. The amount of cyanide ions originating from food products is however rather small. Larger concentrations...
-
Influence of Analyte Flow Rate on Signal and Response Time of the Amperometric Gas Sensor with Nafion Membrane
PublikacjaW publikacji przedstawiono rezultaty badań nad wpływem zmian objętościowego natężenia przepływu gazu na sygnał i czas odpowiedzi prototypowego czujnika ditlenku siarki z membraną nafionową. Porównywano właściwości czujników różniących się materiałem elektrody pracującej oraz składem roztworu elektrolitu wewnętrznego. Zastosowano elektrody pracujące wykonane z napylonych próżniowo na powierzchnię membrany nafionowej złota i platyny....
-
Determination of Chemical Oxygen Demand (COD) at Boron-doped Diamond (BDD) Sensor by Means of Amperometric Technique
Publikacja -
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publikacja -
Determination of Chemical Oxygen Demand (COD) at Boron-doped Diamond (BDD) Sensor by Means of Amperometric Technique
PublikacjaA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Poly-L-Lysine-modified boron-doped diamond electrodes for the amperometric detection of nucleic acid bases
PublikacjaBoron-doped diamond (BDD) is a very promising supporting material used in the construction of biosensors for molecular recognition. The direct immobilization of structurally-organized huge molecules, such as poly-L-Lysine (PLL) provides the possibility of determining organic molecules, e.g. nucleic acid bases (e.g. adenine, guanine) or peptides and proteins. This paper describes the direct method for chemical and electrochemical...
-
Determination of chemical oxygen demand (cod) at boron-doped diamond (bdd) sensor by means of amperometric technique
PublikacjaA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publikacja.A boron-doped diamond (BDD) sensor is proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Boron-doped diamond thin films, acting as active sensors, were deposited on both silicon wafer and glassy carbon (GC) substrates by microwave plasma assisted chemical vapour deposition. SEM micrographs showed that BDD–Si displays triangle-faceted crystallites ca. 0.5–3 μm in size, while BDD–GC...
-
Application of ion chromatography with pulsed amperometric detection for the determination of trace cyanide in biological samples, including breast milk
PublikacjaCyanide (CN) is the biomarker of exposure to the components of tobacco smoke, although its presence in biological samples is also due to the consumption of products containing cyanogenic glycosides. In this work, we determine the concentration of the free cyanide in urine, saliva and breast milk matrices, using ion chromatography with pulsed amperometric detection (IC-PAD). IC-PAD is an emerging method, with only few documented...
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublikacjaThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
Reduced graphene oxide/iron(II) porphyrazine hybrids on glassy carbon electrode for amperometric detection of NADH and L-cysteine
Publikacja -
Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
PublikacjaA simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat...
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublikacjaIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
-
Microsystem for measurement of impedance sensors parameters.Optoelectronic and electronic sensors V.
PublikacjaW artykule przedstawiono mikrosystem do pomiaru parametrów impedancyjnych czujników o module impedancji z przedziału 100ohm-1Gohm. Zastosowana w mikrosystemie technika cyfrowego przetwarzania sygnałów, pozwoliła na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich od 100uHz do 1MHz, przy zachowaniu prostej konstrukcji zapewniającej jego niską cenę. Mikrosystem zrealizowano w formie przyrządu...
-
Multicore Optical Fibres For Sensors
Publikacja -
Sensors and System for Vehicle Navigation
PublikacjaIn recent years, vehicle navigation, in particular autonomous navigation, has been at the center of several major developments, both in civilian and defense applications. New technologies, such as multisensory data fusion, big data processing, or deep learning, are changing the quality of areas of applications, improving the sensors and systems used. Recently, the influence of artificial intelligence on sensor data processing and...
-
Nano-porous alumina humidity sensors
PublikacjaW pracy przedstawiono wyniki badań czujników wilgotności przygotowanych na bazie porowatej aluminy.
-
Fluctuation phenomena in semiconductor gas sensors
PublikacjaCzujniki gazu mogą być wytwarzane z cienkiej warstwy półprzewodnika, która po podgrzaniu do odpowiedniej temperatury staje się czuła na gaz. Zjawisko to jest dobrze znane i szeroko opisane w literaturze. Jako wskaźnik detekcji gazu wykorzystuje się zmianę rezystancji stałoprądowej czujnika. Zwiększenie czułości i, co najważniejsze z praktycznego punktu widzenia, selektywności dyskryminacji można uzyskać jeśli warstwa półprzewodnika...
-
Tools for signal analysis of gas sensors
PublikacjaStatystyki drugiego rzedu oraz jklasyczna analiza widmowa są zwykle stosowane do badania sygnałów losowych o rozkładzie gaussowskim. Są one jednak często nieodpowiednie w przypadku analizy niestacjonarnych sygnałów niegaussowskich. Pewne narzędzia do analizy takich sygnałów sa dostępne w bibliotekach środowiska MATLAB. Zostały one wykorzystane do do analizy fluktuacji sygnałów czujników gazów. W artykule przedstawiono system do...
-
On the selectivity of nanostructured semiconductor gas sensors
Publikacja.
-
GAS SENSORS WITH TEMPERATURE MODULATION – AN OVERVIEW
PublikacjaAlthough different methods of improving semiconductor gas sensor properties have been proposed, a technique involving temperature modulation seems to be the most promising. Semiconductor gas sensors working with modulated temperature can be more stable and are more selective comparing with sensor working at one temperature. In this paper, various approaches to temperature modulation are reviewed.
-
Taguchi sensors under temperature modulation
PublikacjaSemiconductor gas sensors are widely used in gas- analyzing applications for various gas species determination due to their low cost and possibility to detect number of different gases. However, one of the main problems with such sensors is their lack of selectivity. To overcome this issue different ap- proaches can be used. One of them is the operation with sensor temperature modulation combined with dedicated data process- ing...
-
Materials for potentiometric electrochemical gas sensors
PublikacjaPublikacja przeglądowa na temat zasady działania oraz rodzajów czujników elektrochemicznych gazów.
-
Gas sensors based on superionic conductors
PublikacjaW pracy przedstawiono przegląd rozwiązań elektrochemicznych czujników gazów na bazie elektrolitów stałych.
-
The silver layers in fiber-optic sensors
PublikacjaIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
Inertial Sensors Applications in Underwater Measurements
PublikacjaOver the past decades microelectromechanical systems (MEMS) researchers have demonstrated a number of microsensors for almost every possible sensing modality, including attitudes. Current MEMS inertial measurement units (IMU) come in many shapes, sizes, and costs — depending on the application, and performance required. MEMS sensors have proved and demonstrated performance exceeding those of their macroscale counterpart sensors. In...
-
Sensors and Sensor’s Fusion in Autonomous Vehicles
PublikacjaAutonomous vehicle navigation has been at the center of several major developments, both in civilian and defense applications. New technologies such as multisensory data fusion, big data processing, and deep learning are changing the quality of areas of applications, improving the sensors and systems used. New ideas such as 3D radar, 3D sonar, LiDAR, and others are based on autonomous vehicle revolutionary development. The Special...
-
Applications of polarization interferometry in optical sensors
PublikacjaW artykule przedstawiono wybrane realizacje interferometrycznych czujników przesunięcia, wykonanych z elementów optyki objętościowej. Czujniki te, stosowane w technice pomiarowej i mikroskopii, charakteryzują się dużą rozdzielczością i dokładnością pomiaru. Omówiono problemy związane z implementacją tych czujników, wpływające na pogorszenie dokładności pomiaru. Zaprezentowano metody korekcji sygnału wyjściowego, opracowane dla...
-
Solid-state electrochemical gas sensors
PublikacjaW pracy przedstawiono budowę i zasadę działania wybranych typów elektrochemicznych czujników gazów zbudowanych na bazie elektrolitów stałych.
-
The influence of the choice of the cross linking agent on the electrical properties of polyethyleneimine based humidity sensors. Optoelectronic and Electronic Sensors V.
PublikacjaW pracy przedstawiono wyniki badań impedancyjnych polimerowych czujników wilgotności.Czujniki zostały wykonane z chemicznie modyfikowane polietylenoiminy. Przedstawiono wpływ środków sieciujących na właściwości czujników.
-
Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air
PublikacjaThe paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones....