Wyniki wyszukiwania dla: MESH
-
Methodology of generation of CFD meshes and 4D shape reconstruction of coronary arteries from patient-specific dynamic CT
PublikacjaDue to the difficulties in retrieving both the time‑dependent shapes of the vessels and the generation of numerical meshes for such cases, most of the simulations of blood flow in the cardiac arteries use static geometry. The article describes a methodology for generating a sequence of time‑dependent 3D shapes based on images of different resolutions and qualities acquired from ECG‑gated coronary artery CT angiography. The precision...
-
3d Visualization of Seabed from Multibeam Sonar Records Using TriangularIrregular Mesh. W: [CD-ROM] Forum Acusticum Sevilla 2002. 3rd European Con-gres on Acoustics. XXXIII Spanish Congress on Acoustics-TECNIACUSTICA 2002.European and Japanese Symposium on Acoustics. Sevilla, Spain 16-20 Septem- ber 2002. Madrid: Soc. Espanola de Acustica**2002 vol. 33, [6 s.] 4 rys. bibliogr. 6 poz. ISBN: 84-87985-06-8 Special Issue of the Journal Revista de Acustica, vol.33, ano 2002. Trójwym. wizual.dna mors. z danych pochodz. z echosond wielowiąz. z wykorz.niergul.siat.TIN.
PublikacjaPrzedstawiono sposób trójwymiarowej wizualizacji dna morskiego przy wyko-rzystaniu siatki nieregularnej (TIN) otrzymanej w wyniku triangularyzacjioraz porównano otrzymane wyniki z rzeczywistymi pomiarami batymetrycznymidna Bałtyku Południowego.
-
Jacek Rak dr hab. inż.
OsobyJacek Rak uzyskał stopień doktora habilitowanego nauk technicznych w dyscyplinie telekomunikacji (specjalność: teleinformatyka) w 2016 r., a stopień doktora nauk technicznych w dyscyplinie informatyka w 2009 r. Obecnie jest pracownikiem naukowo-dydaktycznym Katedry Teleinformatyki Wydziału Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej. Jego działalność naukowa koncentruje się w obszarze doboru tras, projektowania...
-
Safety and efficacy of a Ventralight ST echo ps implant for a laparoscopic ventral hernia repair – a prospective cohort study with a one-year follow-up
Publikacjaing new products Thus, every mesh prior to introduction in clinical settings should be tested with a dedicated tacker to discover the proper fixation algorithm. The aim of the study was to assess the safety and efficacy of the Ventralight ST implant with an ECHO positioning system and a dedicated fixation device, the SorbaFix stapler, in a prospective cohort of patients. Material and methods. The study was a prospective single...
-
Tomasz Gierszewski dr inż.
Osoby -
Assessment of usefulness of different tacks in laparoscopic ventral hernia repair
PublikacjaLaparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described.
-
Combined numerical and experimental approach to determine numerical model of abdominal scaffold
PublikacjaA proper junction of the prosthesis and the abdominal wall is important in successful hernia repair. The number of tacks should be balanced to assure appropriate mesh fixation and not to induce post-operative pain. Numerical simulations help to find this balance. The study is aimed at creating a proper numerical model of a knitted surgical mesh subjected to boundary conditions and load occurring in the abdominal cavity. Continuous,...
-
A New Type of Macro-Elements for Efficient Two-Dimensional FEM Analysis
PublikacjaThis letter deals with a model order reduction technique applicable for driven and eigenvalue problems solved using the finite element method (FEM). It allows one to efficiently compute electromagnetic parameters of structures comprising small features that require strong local mesh refinement. The subdomains of very fine mesh are separated from the global domain as so called macro-elements that undergo model reduction. The macro-elements...
-
On the necessity of experimental verification of numerical results in biomedical applications
PublikacjaPorous structures made of metal or biopolymers with a structure similar in shape and mechanical properties to human bone can be easily produced by stereolitography techniques, e.g. selective laser melting (SLM). Numerical techniques, like finite element method (FEM) have great potential in testing new, even the most sophisticated designs, according to their mechanical properties, i.e. strength or stiffness. However, due to different...
-
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublikacjaThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
Analiza sieci bezprzewodowych serii IEEE 802.15.x - Bluetooth (BT), UWB i ZigBee - z transmisją wieloetapową. Część I
PublikacjaW artykule zaprezentowano ogólną koncepcję pracy bezprzewodowych sieci mesh (Wireless Mesh Networks - WMNs), tj. sieci ad hoc z topologią złożoną (kratową) i z transmisją wieloetapową. Opisano podstawowe problemy projektowania i implementacji sieci WMN. Przedstawiono ogólne założenia nowego standardu IEEE 802.15.5 - WPAN Mesh. Skoncentrowano się przy tym na opisie i analizie bezprzewodowych sieci złożonych typu WPAN, realizowanych...
-
Analiza sieci bezprzewodowych serii IEEE 802.15.x - Bluetooth (BT), UWB i ZigBee - z transmisją wieloetapową. Część II
PublikacjaW artykule zaprezentowano ogólną koncepcję pracy bezprzewodowych sieci mesh (Wireless Mesh Networks - WMNs), tj. sieci ad hoc z topologią złożoną (kratową) i z transmisją wieloetapową. Opisano podstawowe problemy projektowania i implementacji sieci WMN. Przedstawiono ogólne założenia nowego standardu IEEE 802.15.5 - WPAN Mesh. Skoncentrowano się przy tym na opisie i analizie bezprzewodowych sieci złożonych typu WPAN, realizowanych...
-
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublikacjaThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
-
Mechanizmy odkrywania usług i integracji międzysieciowej w samoorganizujących systemach bezprzewodowych standardu IEEEE 802.11s
PublikacjaWobec gwałtownie rosnącej popularności urządzeń mobilnych rośnie również zainteresowanie bezprzewodowymi systemami dostępowymi. Wśród nich ciekawą propozycją są systemy sieci samoorganizujących się typu mesh, których przykładem może być standard IEEE 802.11s. W artykule przedstawiono propozycje rozbudowy wybranych jego mechanizmów, w wyraźny sposób zwiększające efektywność współpracy sieci mesh z sieciami zewnętrznymi oraz rozwiązaniami...
-
Fluid–Structure Interaction methods for the progressive anatomical and artificial aortic valve stenosis
PublikacjaCardiovascular system diseases, as aortic valve stenosis, are the main cause of mortality and morbidity among patients. There is still a room for enhancement of the diagnostic and therapeutic procedures, which will lead to improvement of the treatment. One of the remedies are the computer tools to support the medical diagnoses and prostheses design. The development of a procedure for modeling the aortic valves: anatomical tricuspid...
-
Complete input data to CFD 3D model of combustion in the large marine 4-stroke engine
Dane BadawczeInput data to CFD and 3D model of combustion process for large marine 4-stroke diesel engine.
-
Impact response of novel layered two stage fibrous composite slabs with different support type
PublikacjaThe performance of novel Layered Two Stage Fibrous Composite slabs (LTSFC) was pioneered under falling mass collisions using a combined experimental and numerical study. Such LTSFC slabs consist of three layers with and without the insertion of glass fibre mesh between the layers. LTSFC techniques were used to fabricate the composite slabs with three layers including 3%, 1.5%, and 3% of fibre content for the top, middle, and...
-
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublikacjaIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
Cyclic polarization studies of Mg corrosion in alkaline environment
Dane BadawczeThe dataset contains the cyclic polarization studies of Mg (99.99%) in NaOH electrolyte at different pH values: 10, 11 and 12 aiming at understanding of Mg(OH)2 passive layer formation mechanism and conditions. The electrochemical studies were carried out in a three electrode setup, with Pt mesh as the counter electrode and Ag|AgCl as the reference...
-
A concept of measurement system based on the Z-Wave standard
PublikacjaIn the paper a new concept of measurement system based on the Z-Wave standard is presented. This standard is dedicated to use mainly in home automation systems, but its properties enable to use it in dispersed measurement systems and support wireless communication between measurement nodes in a mesh-type network. In the paper basic metrological aspects of the Z-Wave standard and an example of impedance measurement system are discussed.
-
Mechanizmy bezpieczeństwa transmisji w systemie netBaltic
Publikacjaartykule zaprezentowano założenia dotyczące zabezpieczania węzłów sieci realizowanej w ramach systemu netBaltic. Ze względu na dużą różnorodność rozważanych mechanizmów komunikacyjnych architektura bezpieczeństwa została podzielona na kilka elementów – infrastrukturę klucza publicznego (PKI), bezpieczeństwo systemowe węzłów, zabezpieczanie komunikacji w modelu samoorganizującej wieloskokowej sieci kratowej, a także sieci niewrażliwej...
-
Smooth Particle Hydrodynamics (SPH) approach in simulating large penetration into soil
PublikacjaA study of Smooth Particle Hydrodynamics (SPH) approach for predicting large soil deformation is presented. Theoretical basics of SPH method, including the equations governing, discussion of the importance of smoothing function length, contact formulation, boundary treatment and finally utilization in hydrocodes simulations are presented. An application of SPH to a real case of large penetrations (crater creating) into soil caused...
-
Cost-Effective and Sufficiently Precise Integration Method Adapted to the FEM Calculations of Bone Tissue
PublikacjaThe technique of Young’s modulus variation in the finite element is not spread in biomechanics. Our future goal is to adapt this technique to bone tissue strength calculations. The aim of this paper is to present the necessary studies of the element’s integration method that takes into account changes in material properties. For research purposes, a virtual sample with the size and distribution of mechanical properties similar...
-
Global Complex Roots and Poles Finding Algorithm Based on Phase Analysis for Propagation and Radiation Problems
PublikacjaA flexible and effective algorithm for complex roots and poles finding is presented. A wide class of analytic functions can be analyzed, and any arbitrarily shaped search region can be considered. The method is very simple and intuitive. It is based on sampling a function at the nodes of a regular mesh, and on the analysis of the function phase. As a result, a set of candidate regions is created and then the roots/poles are verified...
-
Modelowanie losowych imperfekcji geometrycznych przestrzennych konstrukcji metalowych
PublikacjaImperfekcje geometryczne zbiorników, silosów i powłok siatkowych mogą znaczą-co wpłynąć na ich nośność, a więc powinny być one uwzględniane w obliczeniach komputerowych i w procesie projektowania. Wykazano, że przy podstawowych obcią-żeniach, działających na tego typu konstrukcje, tj. podciśnieniu oraz naporu wiatru i śniegu (w przypadku powłok siatkowych), wykazują wyraźne różnice w porównaniu z analogicznymi wynikami dla tych...
-
Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation
Publikacjarelation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients’ life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical...
-
Geometry Parametric Model Order Reduction with Randomly Generated Projection Bases
PublikacjaIn this work, a reduced-order model for geometry parameters and fast frequency sweep is proposed. The Finite Element Method is used to solve time-harmonic Maxwell’s equations. Taking into account the electromagnetic field does not arbitrarily vary as a function of frequency and geometry parameters, a low dimension system manifold is identified. Thus, the original Finite Element problem can be approximated by a model of reduced...
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublikacjaThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
Cyclic voltammetry curves for FTO/PANI:WO3 nanocomposite
Dane BadawczeThis dataset contains the results of kinetic electrochemical studies, carried out with cyclic voltammetry (CV) of FTO/PANI:WO3 nanocomposite at various scan rates: 10, 20, 50, 75, 100 and 200 mV/s. The electrolyte was 1M H2SO4 solution. The measurements were performed in a three electrode setup, and with Ag|AgCl|3M KCl as the reference electrode and...
-
Multi-objective design of miniaturized impedance transformers by domain segmentation
PublikacjaFast multi-objective design optimization of compact microstrip impedance transformers is discussed. Our approach exploits approximation models constructed using sampled coarse- mesh EM simulation data in a partitioned design space and response correction techniques for design refinement. Demonstra
-
Research into flows in turbine blade seals. Part II: Numerical analysis
PublikacjaPrzedstawiono wyniki badań numerycznych programem Fluent przepływów w uszczelnieniu nadbandażowym stopnia turbinowego. Badania wykonano przy zastosowaniu różnych typów siatek obliczeniowych, różnych rodzajów "zszywek" oraz różnych metod obliczeniowych (Mixing Plane, Sliding Mesh, Multiple ReferenceFrame).
-
Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair
PublikacjaEven though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...
-
Biomechanical causes for failure of the Physiomesh/Securestrap system
PublikacjaThis study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh...
-
Virtual spring damper method for nonholonomic robotic swarm self-organization and leader following
PublikacjaIn this paper, we demonstrate a method for self-organization and leader following of nonholonomic robotic swarm based on spring damper mesh. By self-organization of swarm robots we mean the emergence of order in a swarm as the result of interactions among the single robots. In other words the self-organization of swarm robots mimics some natural behavior of social animals like ants among others. The dynamics of two-wheel robot...
-
Multiscale model for blood flow after a bileaflet artificial aortic valve implantation
PublikacjaCardiovascular diseases are the leading cause of mortality in the world, mainly due to atherosclerosis and its consequences. The article presents the numerical model of the blood flow through artificial aortic valve. The overset mesh approach was applied to simulate the valve leaflets motion and to realize the moving mesh, in the aortic arch and the main branches of cardiovascular system. To capture the cardiac system’s response...
-
Partial PLA composite surface activation by femtosecond laser ablation
Dane BadawczeThe dataset contains the studies on electrochemical activity of PLA composite (commercially available CB-PLA Protopasta), which was 3D printed in a form of 1x1cm electrodes. The electrodes were submitted to femtosecond laser ablation, etching a certain % of the electrochemically-exposed electrode size. The % value is in the name of each file. The goal...
-
Modelling of Geared Multi-Rotor System
PublikacjaIn the paper the method of modelling a speed-varying geared rotor system is presented. The proposed approach enables us to obtain an accurate low-order lumped parameter representation of the investigated system. The final model consists of reduced modal models of an undamped beam/torsional shaft system as well as a spatially lumped model of other linear and nonlinear phenomena including gear mesh interaction.
-
Example of Using Particle Swarm Optimization Algorithm with Nelder–Mead Method for Flow Improvement in Axial Last Stage of Gas–Steam Turbine
PublikacjaThis article focuses principally on the comparison baseline and the optimized flow efficiency of the final stage of an axial turbine operating on a gas–steam mixture by applying a hybrid Nelder– Mead and the particle swarm optimization method. Optimization algorithms are combined with CFD calculations to determine the flowpaths and thermodynamic parameters. The working fluid in this study is a mixture of steam and gas produced...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion with different times and concentrations
Dane BadawczeThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K. DIfferent proteinase K concentrations and digestion times were evaluated, as described in subfolder names. The studies were performed before surface activation, during...
-
The photocatalytic activity of MoS2 electrodes under sunlight illumination
Dane BadawczeThis dataset contains the results of the photocatalytic activities of the MoS2 and MoS2 modified by SnO2 were assessed through the photocatalytic reduction of Cr6+ under the sunlight illumination. In the experiment, 20 mg of the catalyst was distributed in the K2Cr2O7 aqueous solution (50 mL, 100 mg•L-1). The mixed solution was stirred for 30 min to...
-
Integration of thermographic data with the 3D object model
PublikacjaThe aim of the paper is to present new method for merging the 3D model data of the measured object with thermograms. Our technique is based on the combination of visual 3D imaging technique and thermal imaging technique, which maps the 2D thermograms on to 3D anatomical mesh model. The combination of these imaging modalities allows the generation of combined 3D and thermal data from which thermal signatures can be verified and...
-
Resilient Routing in Communication Networks
PublikacjaThis important text/reference addresses the latest issues in end-to-end resilient routing in communication networks. The work highlights the main causes of failures of network nodes and links, and presents an overview of resilient routing mechanisms, covering issues related to the Future Internet (FI), wireless mesh networks (WMNs), and vehicular ad-hoc networks (VANETs). For each of these network architectures, a selection of...
-
Possibility of thermal imaging use in studies of natural convection heat transfer on the example of an isothermal vertical plate.
PublikacjaA new method of infrared (IR) camera use in convective heat transfer studies has been presented. Until now, IR cameras were utilized for temperature field visualizations of flat heated surfaces of solid objects only. Because liquids and gasses do not emit radiation in the infrared range of wave lengths, detection of temperature field in the air was conducted with the use of plastic mesh, which, after heating by hot air, emits infrared...
-
Electrochemical cell impedance spectra at Eoc+100mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
The electrochemical studies of CB-PLA surface activation by electrolysis in 1M NaOH
Dane BadawczeThe dataset contains the electrochemical studies performed under different conditions of surface activation of the CB-PLA 3D printed electrodes. The activation was performed by electrolysis in 1M NaOH solution under cycling polarization with different anodic or cathodic overpotentials (data in different subfolders). The file names contain the exact...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion
Dane BadawczeThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K (72h digestion period). Different enzyme concentrations were evaluated: 0.2, 0.4, 0.6 and 0.8 mg/ml. The studies were performed before surface activation, during and...
-
Electrochemical cell impedance spectra at Eoc-100mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...