Wyniki wyszukiwania dla: STEEL COLUMNS
-
CFFT columns in road through railroad crossings
PublikacjaThere were 12801 road through railroad one-level crossings in Poland in 2018. 215 accidents happened at them in 2018. In order to increase safety in rail and road traffic two-level crossings should be used. They are definitely safer and make the traffic more smooth. In the design and construction of two-level intersections of railway and road or path columns of circular cross-section are often used. They can be successfully replaced...
-
Determination of the shape of the CFGFT cylindrical column based on laboratory tests
PublikacjaAnalyses were carried out on glass-fibre-reinforced polymer tube columns with reference to laboratory tests. The angles of the glass fibre beams were 20◦, 55◦ and 85◦. The study employed non-classical operational calculus. Various modulated harmonic signal shapes were considered for columns and tubes at buckling. The buckling loads were assessed and compared for different models.
-
Buckling of thin-walled columns accounting for initial geometrical imperfections
PublikacjaThe paper is devoted to the effect of some geometrical imperfections on the critical buckling load of axially compressed thin-walled I-columns. The analytical formulas for the critical torsional and flexural buckling loads accounting for the initial curvature of the column axis or the twist angle respectively are derived. The classical assumptions of theory of thin-walled beams with non-deformable cross-sections are adopted. The...
-
Selected Stability Problems of Thin-Walled Columns and Beams
PublikacjaThe article reviews a number of papers in the light of buckling analy- sis of thin-walled columns and beams. Stability of thin-walled columns and beams are considered a vital engineering science issue in both historical and present-day approaches. The paper refers to the recent authors’ works of the 2012–2019 period, published in leading journals. Similar review of stability problems of thin-walled structures developed at Gdansk...
-
Long-term operating conditions for different sorption materials to capture phosphate from domestic wastewater
PublikacjaThis paper presents the results of a study on the possibility of applying various configured filters filled with a mixture of Rockfos® and Leca® material for the effective capture of phosphate from domestic wastewater. The tests were carried out for two years at two wastewater flow rates (20 and 40 L/day) in three pairs of filtration columns with a volume of filter material equal to 20 liters each. Columns 1A and 1B were filled...
-
Degradation of stiffness of building columns exposed to bending and impact load during ground motions
PublikacjaThe safety of civil engineering structures under external loads, including ground motions, is one of the issues related to the idea of sustainable society. The earthquake-induced soft-storey failure is a typical type of damage observed in buildings due to seismic excitation. The failure of an intermediate soft storey of a structure results in large vertical impact loading acting on the lower floors due to the fall of the upper...
-
Transportable, Portable and Micro Gas Chromatographs
PublikacjaSignificant benefits can be obtained by miniaturization of conventional benchtop gas chromatographs. The attractive features arising from miniaturization include low-power requirements, low heat capacity of separation columns, low consumption of mobile phase, enhanced performance, higher portability, and easily coupling to detectors and secondary chromatographic systems. In separation sciences, including gas phase separations,...
-
Application of the ‘CPT 2012’model of AFNOR standard for column design in Poland–Jazowa case study
Publikacjahis paper presents the ‘CPT 2012’ model incorporated into the AFNOR NF P94-262:2012-07, French standard for pile design fully compatible with Eurocode 7, to the wider Polish audience. The bearing capacity of three reference columns for Vistula Marshlands have been calculated according to ‘CPT 2012’ model and AFNOR recommendations. Then, the design resistances have been compared with ultimate column bearing capacity measured during...
-
Polycyclic aromatic hydrocarbons as test probes to investigate the retention behavior of 1,3-alternate calix[4]arene silica-bonded stationary phases
PublikacjaA series of polycyclic aromatic hydrocarbons (PAHs) of different size and shape has been used to characterize the chromatographic behavior of five calix[4]arene stationary phases in 1,3-alternate conformation synthesized in our laboratory. The selection of linear, fourring nonlinear, and five-ring PAHs gave data on selectivity changes across range of the calix[4]arene columns. Retention of the 12 aromatic solutes has been evaluated...
-
Characterization of 1,3-alternate calix[4]arene-silica bonded stationary phases and their comparison to selected commercial columns by using principal component analysis
PublikacjaTwelve calix[4]arene stationary phases in 1,3-alternate conformation, synthesized in the authors laboratory, were characterized in terms of their surface coverage, hydrophobic selectivity, aromatic selectivity, shape selectivity, hydrogen bonding capacity and ion-exchange capacity. The set of tests commonly used for evaluation of commercially available stationary phases was applied to assess fundamental chromatographic properties...
-
Distortional buckling of composite thin-walled columns of a box-type cross section with diaphragms
PublikacjaDistortional buckling of axially compressed columns of box-like composite cross sections with andwithout internal diaphragms is investigated in the framework of one-dimensional theory. The channel membersare composed of unidirectional fibre-reinforced laminate. Two approaches to the member orthotropic materialare applied: homogenization based on the theory of mixture and periodicity cells, and homogenization basedon the Voigt–Reuss...
-
Buckling of frame braced by linear elastic springs
PublikacjaIn the design codes and specifications, simplifed formulae or diagrams are given for determining the buckling lengths of frame columns based on the ruling criterion of considering frames as sway or non sway. Due to the fact that, the code formulae utilize onlylocal stifness distributions, these formulae may yield in certain cases rather erroneous results. In most code formulas a case of weakly braced frames is usually not considered.In...
-
Flexural buckling and post-buckling of columns made of aluminium alloy
PublikacjaThe paper concerns flexural buckling and initial post-buckling of axially compressed columns made of aluminium alloy described by the Ramberg-Osgood relationship. The non-linear differential equation of the problem is derived using the stationary total energy principle and the assumptions of classical beam theory within a finite range. The approximate analytical solution of the equation leading to the buckling loads and initial...
-
Sensitivity analysis of flexural and torsional buckling loads of laminated columns
PublikacjaThe paper concerns first order sensitivity analysis of flexural and torsional bucklin g loads of axiallycompressed thin-walled columns with bisymmetric or axisymmetric cross-section made of unidirectional fibre-reinforcedlaminate. The first variation of critical loads versus some variations of the column material properties and cross-sectionaldimensions is derived. Numerical examples dealing with simply supported I-columns are...
-
Local buckling of compressed flange of cold-formed channel members made of aluminum alloy
PublikacjaThe paper deals with local buckling of a compressed single flange of thin-walled channel cold- formed columns and beams made of aluminum alloy. Material is described by means of the Ramberg-Osgood constitutive equation. Axial compression of the columns and beams undergoing bending is taken into consid- eration. A simple model of the member flange in the form a long beam elastically connected to the web is used to find the critical...
-
Method of determining the residual fluxes in transformer core
PublikacjaThe article presents the method of calculating the residual induction in transformer columns. The method is based on measurement of the magnetic induction in selected points around the transformer core. The values of residual induction are calculated as linear combination of the results of measurement.
-
Enhancing the Seismic Resistance of Columns by GFRP Confinement Using Flexible Adhesive-Experimental Study
PublikacjaIn this paper, the results of two experiments, focused on testing the effectiveness of a method of enhancing the seismic (dynamic) resistance of masonry columns with the use of flexible polymer adhesive, are shown. The first experiment was devoted to investigate the damping properties of a polymer working between two stiff layers, whereas the aim of the second one was to verify if the identified damping properties of the polymer...
-
Correlation between natural frequencies and buckling load in a stiffened shell
PublikacjaThe paper deals with correlation between natural frequencies and buckling load of a stiffened shell composed of corrugated sheets and vertical stiffeners (columns). The simplified shell segment represents the buckling behaviour of a whole silo with sparsely distributed columns. The paper covers variants of linear buckling anal-yses, dynamic eigenvalue analyses and geometrically non-linear analyses of a segment modelled with shell...
-
Comparison of High Performance Liquid Chromatography Methods with Different Detectors for Determination of Steroid Hormones in Aqueous Matrices
PublikacjaThis paper presents the development and comparison of procedures for the qualitative and quantitative determination of five estrogenic compounds (17-a-ethynylestradiol, estrone, estradiol, estriol, and progesterone) in drinking water and wastewater samples. Five extraction columns and two disks were tested for their efficiency. The C18 columns were superior on the basis of cost for solid phase extraction of drinking water or sewage....
-
Application of the expanded clay aggregate in form of granular materials for water treatment
PublikacjaThe paper aimed to evaluate the efficiency of Filtralite MonoMulti compared to the conventional dual-media filter beds comprising silica sand layer covered with anthracite coal. Filtralite media are composed of processed (expanded), highly porous clay products characterized by relatively rough grain surfaces. In order to compare these different media filters in a reliable way, the pilot filter columns operated in parallel, under...
-
Buckling of braced frames
PublikacjaIn this paper the classical Winter model, developed originally for columns is applied for frame structures and compared with the results of parametric study of frame with bracing. Sensitivity analysis of critical loads of frame due to bracing stiffness is carried out and the threshold bracing stiffness for full bracing is found. In the non-linear statical analysis the forces in bracings are calculated.
-
Effect of initial imperfection on buckling of thin-walled I columns
PublikacjaEffects of initial geometrical imperfections on critical buckling loads of thin-walled I columns are investigated. Torsional and flexural buckling are taken into account. The column behaviour is described in accord to the theory of thin-walled beams with nondeformable cross-section. Some numerical examples and conclusions related to effects of imperfections on properties of the critical loads are presented.
-
Local buckling of composite channel columns
PublikacjaThe investigation concerns local buckling of compressed flanges of axially compressed composite channel columns. Cooperation of the member flange and web is taken into account here. The buckling mode of the member flange is defined by rotation angle a flange about the line of its connection with the web. The channel column under investigation is made of unidirectional fibre-reinforced laminate. Two approaches to member orthotropic...
-
Experimental Studies of Concrete-Filled Composite Tubes under Axial Short- and Long-Term Loads
PublikacjaThe paper presents experimental studies on axially compressed columns made of concrete-filled glass fiber reinforced polymer (GFRP) tubes. The infill concrete was C30/37 according to Eurocode 2. The investigated composite pipes were characterized by different angles of fiber winding in relation to the longitudinal axis of the element: 20, 55 and 85 degrees. Columns of two lengths, 0.4 m and 2.0 m, were studied. The internal diameter...
-
Corrosion mechanisms in columns for atmospheric distillation of crude oil
PublikacjaThe paper presents the most common corrosion processes occurring in the columns for atmospheric distillation of crude oil. It describes the mechanisms leading to formation of the chemical compounds, which contribute to corrosion phenomena. The main technological factors influencing corrosion processes have been indicated. The paper also presents the interactions between particular corrosion mechanisms resulting in acceleration...
-
An approach for the response of buildings subjected to impact load after soft-story failure due to earthquake excitation
Publikacjahe soft-story failure is one of the most typical types of damage observed in buildings during earthquakes. The failure of an intermediate soft story of a structure results in large impact loading acting on the lower floors due to the fall of the upper stories. The aim of the present paper is to study the behavior of the structural members exposed to such extreme load conditions occurring under ground motion excitation. Special...
-
Distortional buckling of thin-walled columns of closed quadratic cross-section
PublikacjaThe elastic stability of axially compressed column related to the cross-section distortion is investigated. Two kinds of closed quadratic cross-sections are taken into consideration with internal walls and without it. The governing differential equation is derived with aid of the principle of stationary total potential energy. The critical loads for the simply supported columns are found in an analytical form and compared with...
-
Shaking table experimental study on damage mechanism of the disconnecting switch under seismic excitation
PublikacjaThe efficiency of the energetic network is a very import safety issue in the region experienced by the earthquake. High voltage disconnecting switches are important elements of the energetic infrastructure used to separate electric circuits (i.e. during repairs), which should not be damaged remaining fully operational. The aim of the paper is to show the results of the shaking table experimental investigation focused on damage...
-
Local buckling and initial post-buckling behaviour of channel member flange - analytical approach
PublikacjaThe local buckling and initial post-buckling behaviour of the cold-formed channel member flange is investigated. The governing nonlinear differential equation for axially compressed columns and beams undergoing pure bending is derived using the stationary total potential energy principle. The critical stress and initial post-buckling equilibrium path is determined by means of a perturbation approach. The results obtained allow...
-
Installation of CMC columns in overconsolidated clays
PublikacjaDuring rigid inclusions execution in the subsoil some monitoring data are registered by a drilling rig for quality control. The use of these data can improve the design procedure of soil improvement as they can provide some information about the position of bearing strata and the energy necessary to install the column in the ground. In this paper the parameters registered in a drilling machine are described, the installation...
-
The circle object detection with the use of Msplit estimation
PublikacjaThe paper presents the use of Msplit(q) - estimation in the filtration and aggregation of point clouds containing a known number of elliptical shapes with preliminary unknown - locations and dimensions. These theoretical solutions may have practical relevance especially in the modelling of terrestrial laser scanning data of objects that have similar shape to circles. Mentioned shapes can be scanned of tree trunks, columns, gutters,...
-
The Idea of Using Adhesive Bonds in Shaping of Cold-formed Thin-walled Beam-columns
PublikacjaThe chapter concerns the idea of using adhesive bonds in the shaping of cold-formed thin-walled beam-columns. The idea of adhesive-bonded connections is not new but is unlikely to have been used in the design and shaping of thin-walled beam-columns in civil engineering up to date. Metal bar structures, including (due to economic reasons) thin-walled structures, are the most common and effective means to build engineering superstructures/loadbearing...
-
The use of GFRP tubes as load-bearing jackets in concrete-composite columns
PublikacjaThe paper presents the fields of applications of polymer composites in building structures. The use of composite glass fibre tubes is discussed in more detail. The laboratory methods used to test the mechanical properties of these pipes are presented. An original research program is presented, including six concrete-filled glass fibre tubes. The cylinders and columns made in this way were tested for their axial load capacity. Conclusions...
-
Sensitivity analysis of critical loads of I-columns
PublikacjaThe first order variation of critical buckling load of thin-walled columns with bisymmetric open cross-section due to some variations of the design variables such as: cross-section dimensions, or material characteristics is derived. The influence of the residual welding stresses is taken into account. In the numerical examples dealing with I-column the functions describing the effect of the variation of the dimensions of the flange...
-
Mechanical characterization of a gravel column in a calibration chamber operating as a triaxial cell
PublikacjaA series of tests considering the behavior of gravel columns was performed. A segment of column with a height of 1 m and a diameter of 0.53 m was modelled in a calibration chamber used as a triaxial cell at three different lateral stress applied. The vertical load transferred on the column head was simulated with steady increase of water pressures in the upper and lower membranes. During the loading the volumetric changes in the...
-
Development and Validation of SPE-HPLC-MS/MS Method for Determining Cyclophosphamide in Surface Waters
PublikacjaA rapid and selective method for trace amounts determination of cyclophosphamide in surface water samples has been developed. A solid phase extraction SPE method for extraction and clean-up procedure has been optimized for determination by reversed-phase high-performance liquid chromatography with tandem mass spectrometry. The analyses proceed in the positive ion mode by means of the electrospray ionization method (ESI). Clean...
-
Analysis of floor-to-column pounding of buildings founded on different soil types
PublikacjaThe aim of this study is to investigate the effect of the soil type on buildings experiencing floor-to-column pounding during earthquakes. Five buildings with 4-storeys, 6-storeys, and 7-storeys were considered. Three types of the 4-storey building with different total heights were taken into account which leads to floor-to-column pounding at 1/3, 1/2 and 2/3 of the height of the impacted column. Two pounding scenarios were considered,...
-
9-(Trichloroacetylimino)acridine monohydrate
PublikacjaThe title compound, alternatively called N-acridin-9(10H)-ylidene-2,2,2-trichloroacetamide monohydrate, C15H9Cl3N2O·H2O, crystallizes in space group P21/c with Z = 4. The acridine moieties are arranged in layers, tilted at an angle of 15.20 (4)° relative to the ac plane, while adjacent molecules pack in a head-to-tail manner. Acridine and water molecules form columns along the b axis held in place by a network of hydrogen...
-
Methods of assaying volatile oxygenated organic compounds in effluent samples by gas chromatography—A review
PublikacjaThe paper is a review of the procedures for the determination of volatile and semivolatile oxygenated organic compounds (O-VOCs) in effluent samples by gas chromatography. Current trends and outlook for individual steps of the procedure for the determination of O-VOCs in effluents are discussed. The available sample preparation techniques and their limitations are described along with GC capillary columns used for O-VOCs separation...
-
Torsional buckling and post-buckling of columns made of aluminium alloy
PublikacjaThe paper concerns torsional buckling and the initial post-buckling of axially compressed thin-walled aluminium alloy columns with bisymmetrical cross-section. It is assumed that the column material behaviour is described by the Ramberg–Osgood constitutive equation in non-linear elastic range. The stationary total energy principle is used to derive the governing non-linear differential equation. An approximate solution of the equation...
-
Study on 19th-century cast iron columns from the former financial office building in Kwidzyn
PublikacjaThe article presents the results for cast iron columns used as floor supports in the former financial office building in Kwidzyn (Poland).The stocktaking drawings provided the general and detailed data about the 19th century designer’s decisions. During the research, architectural and structural analysis was carried out. The graphics were used as a starting material for preparing 3D calculation models. The FEM-based numerical simulations...
-
Quality evaluation of agricultural distillates using different types of electronic noses
PublikacjaThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with TGS type semiconductor sensors. HERACLES II included two chromatographic columns with different polarity of stationary phase and two FID detectors. In case of the prototype volatile fraction...
-
Response of high voltage disconnector under seismic excitation - experimental and numerical study
PublikacjaThe efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....
-
Pore Water Pressure Development in Soft Soil due to Installation and Loading of Controlled Modulus Columns
PublikacjaExcess pore water pressure (EPWP) development and decay due to the installation and static loading tests of controlled modulus columns (CMC) in soft soil was measured with piezometers equipped with low air entry (LAE) filters and a piezocone (CPTU) equipped with a high air entry (HAE) filter. The HAE filter allows for detailed detection of EPWP in short time intervals during construction of CMC. The influence zone due to the installation...
-
Miniaturized Solid Phase Extraction techniques for different kind of pollutants analysis: State of the art and future perspectives – PART 1
PublikacjaSolid Phase Extraction (SPE) has been practiced in a modern form for more than half a century. It was constantly developing, driven by the analysts needs. These needs are coming from the importance to select an appropriate analytical method, which should have satisfactory accuracy, precision and sensitivity. In the case of sorbent-based microextraction techniques, the choice of miniaturized variants that meet these requirements...
-
Local buckling of thin-walled channel member flange made of aluminum alloy
PublikacjaThe paper deals with local stability of the thin-walled compressed flange of channel columns and beams made of aluminum alloy. The aim of paper is to find critical stress of local buckling of the flange member taking into account the web-flange interaction in linear and nonlinear elastic range of the member material. The governing differential equation of the problem is derived with aid of the principle of stationary total potential...
-
Distillation cleanup preceded gc determination of short-chain monocarboxylic acids in aqueous and solid samples of wastewater origin = Oznaczanie krótkołańcuchowych kwasów monokarboksylowych w próbkach wodnych i stałych pochodzących z oczyszczalni ścieków z wykorzystaniem chromatografii gazowej poprzedzonej destylacją
PublikacjaShort-chain monocarboxylic acids (SCMAs) (C2-C5) formed in the process of aerobic biodegradation of larger organic molecules should often be monitored to optimize wastewater biological treatment and study the processes of converting organic waste matter into methane, etc. Gas chromatography (GC) seems a method of choice for such a task. Majority of samples require clean up before they can be injected into GC system. In this work...
-
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublikacjaThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
Rotational stiffness of a connection made using a single prestressed bolt
PublikacjaThe often overlooked rotational stiffness of connections utilizing a single prestressed bolt leads to the common assumption of treating such connections as pinned or even modeling them as rigid. Nevertheless, considering the friction between interconnected elements, it is evident that the actual rotational stiffness lies between these simplified assumptions. This study is dedicated to quantifying this stiffness and addressing the...
-
Analysis of the Hydrodynamic Properties of the 3-Column Spar Platform for Offshore Wind Turbines
PublikacjaThe article presents a design of a floating platform for offshore wind turbines. The concept is a modification of the Spar design and consists of three variable section columns connected to each other by a ballast tank in the lower part of the platform. This solution makes it possible to influence the position of the centre of buoyancy and the centre of mass of the structure. Compared to the classic Spar platform structure, the...