Wyniki wyszukiwania dla: IMPLANTS, TITANIUM ALLOYS
-
The influence of biological environment on the appearance of silver-coated implants
PublikacjaDespite antibiotics preventive treatment before and after implantation, risk of infection is real. The infections at the implant surface developein a few months after applying them into the body. To prevent the development of bacteria and to reduce the risk of infection, implants coated with silver layer come into use. The paper presents the research results in biological environment on vein and orthopaedicimplants covered with...
-
Titanium Scaffolds – Hopes and Limitations
PublikacjaThe state-of-art on titanium scaffolds is briefly reviewed. The real hopes from medicine associated with scaffolds are indicated. The limitations of different scaffolds associated with their mechanical, chemical and biological properties are discussed. The great importance of titanium scaffolds is demonstrated as the materials of high biocompatibility and corrosion resistance, fair mechanical properties and important biological...
-
Review of titanium and steel welding methods
PublikacjaThe paper presents review of methods of titanium and steel welding. On basis of professional literature it was stated that titanium can be joined with steel by means of explosive welding or brazing.Joining titanium with steel by TIG welding and friction welding methods is possible with the use of copper and tantalum or vanadium interlayer.
-
The bahaviour of selected silver coated body implants in presence of various bacteria
PublikacjaThe article deals with implants covered with silver nanoparticles and its influence on bacteria adhesion.
-
Bioactive core material for porous load-bearing implants
PublikacjaSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
The Effect of Titanium Oxyfluoride Morphology on Photocatalytic Activity of Fluorine-Doped Titanium(IV) Oxide
PublikacjaTitanium oxyfluoride (TiOF2) is a metastable product that can be obtained in a fluorine-rich environment. This material can also be a valuable precursor in the synthesis of titanium(IV) oxide (TiO2). However, the effect of TiOF2 morphology on the physicochemical properties of TiO2 has not been studied so far. In this work, single-phase TiOF2 was prepared by a solvothermal method. The as-synthesized samples exhibited a variety of...
-
Bioactive polyurethanes applied as a surgical implants
PublikacjaSynthetic materials are applied in many branches of the industry, i.a. in medicine as a casing of apparatus, elements of artificial organs (hearts, blood vessels), catheters, wound healings, intra aortic balloons, mammary implants to mention but a few. Polymeric material used in such applications must be distinguished by a good biocompatybility. Since many years extensive research are employed to develop a new polymers that can...
-
Application and mechanical properties of aluminium alloys
PublikacjaThe paper presents a short survey of the application and mechanical properties of aluminium alloys. This area of scientific research is still developing, the authors restricted it to about 30 papers. Numerical simulations of the aluminium bracket are also investigated. The authors propose a solution to increase the load capacity of aluminium brackets with application of the additional cover plates. This study is proposed as an...
-
Multicomponent layers for aluminium alloys surface consolidation
PublikacjaThe main reason of the surface modification of the components such as pistons and cylinder blocks made of cast aluminium alloys is to obtain high hardness, wear and corrosion resistance of the working surface for larger lifetime of the motor-car and aircraft engines. In that aspect, the new conception of development - by hybrid method - of surface layers containing manganese, nitrogen, sulphur (Mn-N-S) and manganese, nitrogen,...
-
Conducting polymers for biodegradable metallic implants
PublikacjaNowadays permanent metallic cardiovascular stents are long-term implants. The long-time presence of such an implant in human body can cause overgrowth of tissue within the treated portion of the vessel, blockage of the circulatory system and many other clinical complications, such as thrombosis, prolonged physical irritations or chronic inflammation. Therefore, in recent years, there is an interest to create biodegradable metallic...
-
Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction
PublikacjaCementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the rough surface of the implant, a process called osseointegration. However, debonding of the bone–implant interface can still occur due to aseptic implant loosening and insufficient osseointegration, which may have dramatic consequences. The aim of this work is to...
-
Self-Organized Nanotubular Oxide Layers on Ti and Ti Alloys
PublikacjaTo improve bioactivity of titanium and titanium, the implant surface modification by formation of self-organized TiO2 nanotube arrays with electrochemical techniques is presented. The influence of electrolyte composition and deposition parameters during anodization is characterized. The enhancement of phosphates deposition by titanium nanotubular structure is discussed. The calcium phosphate ceramics is shown to be uniformly deposited...
-
Mechanical Properties of Implants
PublikacjaW pracy przedstawiono wyniki identyfikacji ortogonalnego modelu matematycznego czterech typów implantów stosowanych w laparoskopowym leczeniu przepukliny brzusznej.
-
Structure and thermoelectric properties of Bi–Te alloys obtained by novel method of oxide substrates reduction
PublikacjaA novel method of thermoelectric materials fabrication has been developed. Oxide reagents have been melted at high temperature in air, quenched, milled to powder and reduced in hydrogen to form Bi–Te alloys. Structural and thermoelectric properties of samples have been investigated depending on initial composition and temperature of reduction process. Sample 25Bi2O3–75TeO2 reduced at 340 °C for 10 h has been found to be a p-type...
-
Hydrogen-enhanced degradation and oxide effects in zirconium alloys for nuclear applications
PublikacjaThe zirconium alloys used in nuclear industry include mainly ZreSn and ZreNb alloys ofdifferent chemical composition, microstructure and susceptibility to both hydrogendegradation and oxidation. The hypothetic nuclear accidents can create a real danger tothe Zr alloys and stability of parts made of these alloys, and especially such as loss ofcoolant accident (LOCA) and reactivity initiated accidents (RIA). The hydrogen degradationcan...
-
Dynamical properties of ordered Fe–Pt alloys
Publikacja -
Electrical and mechanical characterization of two-phase alloys by means of scanning probe microscopy in dynamic impedance spectroscopy mode
PublikacjaDynamic impedance spectroscopy, evaluated for measuring non-stationary systems, was used in combination with scanning probe microscope. Using this approach, localized impedance measurements in the AFM contact mode could be carried out. Additionally, impedance–force curves were made at each phase of investigated materials to illustrate the relation between impedance and the force applied to a probe. Therefore, correlation of electrical...
-
Debonding of coin-shaped osseointegrated implants: Coupling of experimental and numerical approaches
PublikacjaWhile cementless implants are now widely used clinically, implant debonding still occur and is difficult to anticipate. Assessing the biomechanical strength of the bone–implant interface can help improving the understanding of osseointegration phenomena and thus preventing surgical failures. A dedicated and standardized implant model was considered. The samples were tested using a mode III cleavage device to assess the mechanical...
-
Cochlear Implants International
Czasopisma -
3D Printing of Metallic Implants
PublikacjaThe fabrication of various elements, solid and open porous structures of stainless steel and Ti alloy is described. The process was started with the design of 3D models in CAD/CAM system. The 3D models were transformed into *.stl files and then the manufacturing process of the real structures by means of the selective laser melting with the SLM Realizer 100 3D printer was made. The paper shows the porous specimens made for possible...
-
High-temperature properties of titanium-substituted yttrium niobate
Publikacjahe defect fluorite titanium-doped yttrium niobate samples Y3Nb1−xTixO7−δ have been synthesized and investigated by the means of high-temperature X-ray diffraction, dilatometry, and thermogravimetry. Thermal expansion coefficients (TECs) as well as chemical expansion coefficients for material with 5, 10, and 15 mol% of titanium were determined. All investigated samples exhibit chemical contraction caused by Ti doping. The values...
-
Review on friction stir welding of dissimilar magnesium and aluminum alloys: Scientometric analysis and strategies for achieving high-quality joints
PublikacjaMagnesium and aluminum alloys continually attract interest as lightweight structural materials for transport applications. However, joining these dissimilar alloys is very challenging. The main obstacle that hinders progress in dissimilar Mg-Al joining is the formation of brittle intermetallic compounds (IMCs). As a solid-state joining technique, FSW is an excellent candidate to attenuate the deleterious IMC effects in dissimilar...
-
Hydrogen degradation of pre-oxidized zirconium alloys
PublikacjaThe presence of the oxide layers on Zr alloys may retard or enhance the hydrogen entry and material degradation, depending on the layer features. This research has been aimed to determine the effects of pre-oxidation of the Zircaloy-2 alloy at a different temperature on hydrogen degradation. The specimens were oxidised in laboratory air at 350°C, 700°C, and 900°C. After, some samples were tensed at 10-5 strain rate and simultaneously...
-
Identification of Bodner-Partom Viscoplastic Model Parameters for Some Aluminum Alloys at Elevated Temperature
PublikacjaThe paper presents the identification process of inelastic (viscoplastic) properties for two aluminum alloys at a temperature of 120°C. The material parameters are calculated on the basis of uniaxial tension tests. Twelve tests at elevated temperature for each alloy have been performed—three tests for four different strain rates. The main purpose of the paper is to identify the Bodner-Partom viscoplastic model parameters for two...
-
High temperature corrosion and corrosion protection of porous Ni22Cr alloys
PublikacjaIn this work corrosion kinetics of the porous IN625 alloy is studied in the temperature range of 700 °C – 800 °C in air and humidified hydrogen for up to 1000 hours. Moreover, an effective and simple method of reducing corrosion rates of porous alloys by the infiltration of the rare earths elements is shown. Modification by the yttrium containing precursor reduces the corrosion rate by a factor of 50 in air at 700 °C so that the...
-
Investigation of corrosion behavior of 6060 and 6082 aluminum alloys under simulated acid rain conditions
PublikacjaInstantaneous impedance changes of 6060 and 6082 type aluminum alloys in pure water, and simulated acid rain poured into the pure water was investigated by dynamic electrochemical impedance spectroscopy (DEIS). In this way, the influence of aluminum content on the corrosion behavior of 6060 and 6082 type aluminum alloys immersed in simulated acid rain was determined. The corrosion rate of the alloy decreased with increasing Al...
-
Preparation of nano-tubular oxide layers on titanium alloy Ti13Nb13Zr
PublikacjaThe article presents results of oxidation tests and corrosion investigations of titanium alloy Ti13Nb13Zr preformed at different conditions. The oxide layers have been formed using electrochemical method in 2M H3PO4 + 0,3% HF solution for 30 min. and 1h at 20V constant voltage. The corrosion tests heve been made with poteniodynamic method in Ringer's solution at pH ranged 3 and 7. It has been shown that the nano-oxide films, which...
-
Microstructural Analysis of Fractured Orthopedic Implants
Publikacja -
In vivo degradation of short-term implants
PublikacjaStan powierzchni wywiera istotny wpływ na właściwości użytkowe implantu. Stawiane wymagania, zależą od funkcji jakie ma spełniać wszczep oraz rodzaju implantowanego materiału. W przypadku implantów krótkotrwałych wymagana jest przede wszystkim odpowiednia odporność korozyjna, nie powinno tworzyć się trwałe połączenie pomiędzy wszczepem a tkanką kostną.Wszystkie biomateriały ulegają degradacji. Ważne jest to, aby produkty tej degradacji...
-
Degradation of metal implants covered with silver
PublikacjaSilver was known for its antibacterial properties as long ago as in antiquity. The silver ions have ability to join the bacteria surface. Low density of silver ions Ag+ influence the protons through the bacteria surface, which results in total destruction of the cell. Antibacterial activity of silver remains in proportion with the density of silver ions Ag+ in the environment.
-
Application of Shape Memory Alloys in Pipeline Couplings for Shipbuilding
PublikacjaThe aim of the study is to analyse shape memory alloy (SMA) pipeline joints in limited space applications for all kinds of ships. Generally, the space available in various areas on ships is strictly limited and service works usually meet many obstacles. If we consider a pipeline, the flange joints always require a larger free space around the pipe than the pipe alone. A simultaneous problem can occur with the propeller shaft line...
-
Influence of titanium layer on counter electrode on electrical parameters of DSSC
PublikacjaIn this paper the influence of the Ti layer thickness at counter-electrode on electrical parameters of DSSCs was examined. The transparent conductive oxide – less (TCO-less) counter electrodes (CE) with titanium layers and platinum as catalyst on Bk7 glass were prepared. Thin metallic films were deposited by means of magnetron sputtering (titanium) and Pulsed Laser Deposition (platinum). The counter electrode with Pt layer on Fluorine...
-
Structure and properties of liquid Al–Cu alloys: Empirical potentials compared
PublikacjaWe report on the structure and mass transport properties of liquid Al–Cu alloys predicted by two recently-developed empirical many-body potentials: MEAM (Jelinek et al., 2012) and EAM-ADP (Apostol and Mishin, 2011), and by the well-known Gupta potential. Total and partial pair correlation functions, angular distribution functions, densities, coordination numbers and self-diffusion coefficients are compared with published experimental...
-
Fabrication, Microstructure and High Temperature Corrosion Resistance of Porous Alloys for Solid Oxide Fuel Cells
PublikacjaPorous alloys find use in modern Solid Oxide Fuel Cells as the supporting structures. As they are exposed to high temperatures (> 500°C) an oxide scale forms on their surface due to high temperature corrosion phenomena. Since the ratio between the surface area and volume is much higher than for planar samples, formation of the oxide can lead to a breakaway oxidation after relatively short times. Therefore corrosion properties of...
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
Effects of the Origin and Deacetylation Degree of Chitosan on Properties of Its Coatings on Titanium
PublikacjaThe properties of chitosan coatings on titanium surfaces may be influenced by a variety of factors, including their chemical characteristics and the deposition method. The aim of this research was to determine the influence of a chitosan’s origin (a type of shrimp) and deacetylation degree (DD), when deposited on a very smooth titanium surface, on adhesion and biological behavior. The tests were performed using chitosan of a degree...
-
Reactivity study of a β-diketiminate titanium(III) complex with a phosphanylphosphido ligand towards chlorophosphanes. A new method of synthesis of β-diketiminate titanium(IV) complexes with versatile phosphanylphosphinidenes
PublikacjaThe reactivity of ab-diketiminate titanium(III) complex with a phosphanylphosphido ligand, [MeNacNacTi(Cl){g2-P(SiMe3)-PtBu2}] (1)(MeNacNac= [Ar]NC(Me)CHC(Me)N[Ar]; Ar = 2,6-iPr2Ph), was investigatedtowards selected chlorophosphanes, such astBu2PCl,iPr2PCl, Cy2PCl, (Cy)tBuPCl, (Me)tBuPCl, (Ph)tBuPCl, Ph2PCl, (iPr2N)tBuPCl and (Et2N)2PCl. The reactions withtBu2PCl and Ph2PCl lead mainly to theearlier described complex [MeNacNacTi(Cl){g2-P-PtBu2}]...
-
New techniques assisting cochlear implants fitting.
PublikacjaW referacie przedstawiono metodę telemetrii odpowiedzi neuronalnej (SoE), którą zastosowano w celu oceny amplitudy sygnału, która będzie wywoływała percepcję słuchową poprzez pobudzenie elektrod implantu ślimakowego. Jest to obiektywna metoda wyznaczania skuteczności systemów implantów ślimakowych.
-
Porous materials used as inserted bone implants
PublikacjaArtykul zawiera przegladowa analize literatury dotyczaca scaffoldow
-
Advancements in the Additive Manufacturing of Magnesium and Aluminum Alloys through Laser-Based Approach
PublikacjaComplex structures can now be manufactured easily utilizing AM technologies to meet the pre-requisite objectives such as reduced part numbers, greater functionality, and lightweight, among others. Polymers, metals, and ceramics are the few materials that can be used in AM technology, but metallic materials (Magnesium and Aluminum) are attracting more attention from the research and industrial point of view. Understanding the role...
-
Properties of surface layers of titanium alloy Ti6Al4V after laser melting processes
PublikacjaThe article presents the investigation results of titanium alloy Ti6Al4V surface layer after laser melting process. The process of laser melting was performed using Nd-YAG laser. The evaluation of structure of the alloy as well as hardness and chemical composition was performed. It was shown that laser melting changes the structure and properties of titanium alloy Ti6Al4V and process parameters as scanning speed affects the thickness...
-
CLINICAL ORAL IMPLANTS RESEARCH
Czasopisma -
Aggregation of Rhodamine 6G in titanium dioxide nanolayers and bulk xerogels
PublikacjaNanolayers and bulk xerogels of Rhodamine 6G (Rh6G) in titanium dioxide (Rh6G/TiO2) were prepared using the sol–gel method. The spectroscopic and structural properties of these two types of hybrid matrices were studied as a function of dye concentration. In both cases absorption, fluorescence and time resolved emission spectra show the formation of fluorescent aggregates. The observed stronger changes in characteristics of bulk...
-
Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study
PublikacjaPrimary stability of cementless implants is crucial for the surgical success and long–term stability. However, primary stability is difficult to quantify in vivo and the biomechanical phenomena occurring during the press–fit insertion of an acetabular cup (AC) implant are still poorly understood. The aim of this study is to investigate the influence of the cortical and trabecular bone Young's moduli Ec and Et, the interference...
-
Pre-oxidation of porous ferritic Fe22Cr alloys for lifespan extension at high-temperature
PublikacjaPre-oxidation of porous ferritic Fe22Cr alloys was extensively studied in this paper. Weight gain measurements and SEM analysis revealed that pre-oxidation performed at 900◦C for 40 min increased the lifespan of the alloy. A Cr evaporation study did not disclose any significant influence of the pre-oxidation process on the Cr content in the alloy. For a more detailed assessment, TEM imaging and X-ray tomography measurements of...
-
Effect of native air-formed oxidation on the corrosion behavior of AA7075 aluminum alloys
PublikacjaThe microstructure of aluminum alloys plays a key role in their corrosion resistance. In particular, the presence of intermetallic precipitates differing in the potential from the alloy matrix induces local corrosion. The study presents the effect of native air-formed oxidation on the corrosion behavior of AA 7075 aluminum alloy. Various microscopic and spectroscopic techniques were used to examine the changes occurring in the...
-
Influence of High Temperature Oxidation on Hydrogen Absorption and Degradation of Zircaloy-2 and Zr 700 Alloys
PublikacjaThe present research was aimed at determining the effects of the oxide layers on hydrogen absorption, microstructure and mechanical properties of the Zircaloy- 2 and Zr 702 alloys. The oxidation was made at 350 °C, 700 °C and 900 °C for 10 to 30 min in laboratory air, followed by hydrogen cathodic charging for 72 h and annealing at 400 °C for 4 h. The slow strain rate tests were carried out on oxidized, charged and annealed specimens. The...
-
Impedance Studies of Phosphate-iron Glasses Containing Niobium and Titanium
PublikacjaThe ac and dc conductivity in phosphate-iron-niobate glasses with addition of titanium oxide was investigated as a function of temperature and frequency with the use of impedance spectroscopy. The topography and microstructure of glasses were investigated by the means of X-ray diffraction (XRD), scanning electron microscopy (SEM), and confocal microscopy methods. The obtained results show that all samples are amorphous but they...
-
UV/VIS Spectroscopy of titanium dioxide coated nickel foams
Dane BadawczeThe data includes UV-Vis spectra of titanium dioxide coated nickel foams heated at 400, 500 and 600 C in Ar. Jasco V-650 Spectrophotometer was used and Spectra Measurement software.
-
Exploring Mechanism of Corrosion Inhibition of WE43 and AZ31 Alloys by Aqueous Molybdate in Hank’s Solution by Multisine Impedimetric Monitoring
PublikacjaThe concept of utilizing multisine dynamic electrochemical impedance spectroscopy to monitor effectiveness of a model molybdate inhibitor for AZ31 and WE43 Mg alloys is proposed. The corrosion kinetics and instantaneous values of inhibition efficiency (IE) of molybdate at concentrations up to 150 mM were examined. The inhibitor provides inhibition in Hank’s solution at concentrations starting from ca. 25 mM, with the IE of about...