Solution of the dike-break problem using finite volume method and splitting technique
PublikacjaIn the paper the finite volume method (FVM) is presented for the solution of two-dimensional shallow water equations. These equations are frequently used to simulate the dam-break and dike-break induced flows. The applied numerical algorithm of FVM is based on the wave-propagation algorithm which ensures a stable solution and simultaneously minimizes the numerical errors. The dimensional decomposition according to the coordinate...
-
Towards Synthetic and Balanced Digital Government Benchmarking
PublikacjaReliable benchmarking is essential for effective management of the government digitalization efforts. Existing benchmarking instruments generally fail to support this target. One problem is the diversity of instruments, resulting in a split image of digital progress and adding ambiguity to policy decisions. Another problem is disconnect in assessing progress between digital and traditional “analog” governance, lending support to...
-
Experimental study and numerical simulation of the dynamic penetration into dry clay
PublikacjaTests of dry clay were carried out in a uniaxial stress state using the experimental setup which implements the split Hopkinson pressure bar method. Based on the results of these experiments, the compressive strength of clay was determined as an important element of S.S. Grigoryan’s model of the soil medium. In addition, the parameters of this model are determined from the results of experiments using the modified Kolsky method...
-
Identification of Risk Factors for Collisions Involving Cyclists Based on Gdansk Example
PublikacjaThe role of pedestrian and bicycle traffic in Poland has growing trend. The comprehensive traffic study, conducted in Gdansk in 2016, has confirmed the increase in the number of cyclists and their share in the modal split. Therefore, it is particularly important to ensure the safety of this group of unprotected road users. Only in 2015 on the roads of Gdansk occurred 93 accidents (excluding collisions) involving cyclists. As a...
-
Average Size of a Suffix Tree for Markov Sources
PublikacjaWe study a suffix tree built from a sequence generated by a Markovian source. Such sources are more realistic probabilistic models for text generation, data compression, molecular applications, and so forth. We prove that the average size of such a suffix tree is asymptotically equivalent to the average size of a trie built over n independentsequences from the same Markovian source. This equivalenceis only known for memoryless...
-
Electromagnetic plane wave scattering from a cylindrical object with an arbitrary cross section using a hybrid technique
PublikacjaA hybrid technique combining finite-element and mode-matching methods for the analysis of scattering problems in open and closed areas is presented. The main idea of the analysis is based on the utilization of the finite-element method to calculate the post impedance matrix and combine it with external excitation. The discrete analysis, which is the most time- and memory-consuming, is limited here only to the close proximity of...
-
Data on solutions of Hes1 system
Dane BadawczeHes1 protein (hairy and enhancer of split 1) belongs to the helix-loop-helix (bHLH) family of transcription proteins, i.e. DNA-binding proteins in the promoter region or in another region where regulation of transcription processes occurs. The database collects data on solutions of the Hes1 systems with multiple binding sites and the dimer formation...
-
All graphs with paired-domination number two less than their order
PublikacjaLet G=(V,E) be a graph with no isolated vertices. A set S⊆V is a paired-dominating set of G if every vertex not in S is adjacent with some vertex in S and the subgraph induced by S contains a perfect matching. The paired-domination number γp(G) of G is defined to be the minimum cardinality of a paired-dominating set of G. Let G be a graph of order n. In [Paired-domination in graphs, Networks 32 (1998), 199-206] Haynes and Slater...
-
Nested Kriging Surrogates for Rapid Multi-Objective Optimization of Compact Microwave Components
PublikacjaA procedure for rapid EM-based multi-objective optimization of compact microwave components is presented. Our methodology employs a recently developed nested kriging modelling to identify the search space region containing the Pareto-optimal designs, and to construct a fast surrogate model. The latter permits determination of the initial Pareto set, further refined using a separate surrogate-assisted process. As an illustration,...
-
Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
PublikacjaIn this paper, a tuning method of a resonant circuit suited for wireless powering of miniature endoscopic capsules is presented and discussed. The method allows for an automatic tuning of the resonant frequency and matching impedance of a full wave rectifier loading the resonant circuit. Thereby, the receiver tunes so as to obtain the highest power efficiency under given conditions of transmission. A prototype receiver for wireless...
-
Pemphigus vulgaris - Female, 42 - Tissue image [10040729541216511]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Organic syntheses greenness assessment with multicriteria decision analysis
PublikacjaGreen chemistry requires a metrics system that is comprehensive by the criteria included and simple in the application at the same time. We propose the application of multicriteria decision analysis for com- parative greenness assessment of organic synthesis procedures. The assessment is based on 9 criteria (the reagent, reaction efficiency, atom economy, temperature, pressure, synthesis time, solvent, catalyst and reactant) for...
-
Performance assessment of OpenMP constructs and benchmarks using modern compilers and multi-core CPUs
PublikacjaConsidering ongoing developments of both modern CPUs, especially in the context of increasing numbers of cores, cache memory and architectures as well as compilers there is a constant need for benchmarking representative and frequently run workloads. The key metric is speed-up as the computational power of modern CPUs stems mainly from using multiple cores. In this paper, we show and discuss results from running codes such as:...
-
An isogeometric finite element formulation for frictionless contact of Cosserat rods with unconstrained directors
PublikacjaThis paper presents an isogeometric finite element formulation for nonlinear beams with impenetrability constraints, based on the kinematics of Cosserat rods with unconstrained directors. The beam cross-sectional deformation is represented by director vectors of an arbitrary order. For the frictionless lateral beam-to-beam contact, a surface-to-surface contact algorithm combined with an active set strategy and a penalty method...
-
Novel sorptive extraction techniques in bioanalysis evaluated by Blue Applicability Grade Index: The paradigm of fabric phase sorptive extraction and capsule phase microextraction
PublikacjaFabric phase sorptive extraction (FPSE) and capsule phase microextraction (CPME) are two sol-gel derived microextraction techniques that emerged in the last decade towards the minimization of the environmental impact of conventional sample preparation approaches. Complementary to the well-established green metric tools, Blue Applicability Grade Index (BAGI) was recently proposed for the evaluation of method’s practicability. In...
-
Towards Precise Visual Navigation and Direct Georeferencing for MAV Using ORB-SLAM2
PublikacjaA low accuracy of positioning using Global Navigation Satellite System (GNSS) are not meet geodetic requirements for direct images georeferencing for Unmanned Aerial Vehicle (UAV) photogrammetry. A majority of UAVs are equipped with a monocular or stereo non-metric cameras for either visual data gathering or live video feed for operator. A cheap positioning techniques used on board commercial UAVs are not that precise as geodetic...
-
Rheological characteristics of oligomeric semiproducts gained via chemical degradation of polyurethane foam using crude glycerin in the presence of different catalysts
PublikacjaPolyurethane (PU) recycling is a topic of growing interest due to the increasing amount of polyurethane waste. The main purpose of polyurethane chemical recycling is to recover the starting polyol. In this study, a method of polyurethane thermochemical recycling, glycerolysis by means of crude glycerin, is proposed. This work presents a comparative study of commercial catalysts used in order to accelerate the decomposition process,...
-
Preferences and Transport Behavior of Gdansk Residents in the Light of the Result of Complex Traffic Survey
PublikacjaPreferences and transport behavior of the population are a fundamental aspect of research in public transport. Identifying the basic postulates of transport, the factors determining the specific behavior of transport and modal split allow to analyze the differences between the groups singled passengers and to prepare better offer of an urban transport. In Poland, still in many cities urban transport research is conducted ad hoc,...
-
Diagnosis of marine internal combustion engines by means of rapidly variable temperature and composition of exhaust gas as an alternative or support for currently used diagnostic methods
PublikacjaThe article points out relevance of parametric diagnostics of ship engines and analyzes the state of research in this field. A method is proposed for diagnosing engine systems on the basis of rapidly variable exhaust temperature while measuring its composition. A method for determining diagnoser tools from the signal within one engine cycle and mathematical and statistical treatment of test results is presented. The products of...
-
Visual Lip Contour Detection for the Purpose of Speech Recognition
PublikacjaA method for visual detection of lip contours in frontal recordings of speakers is described and evaluated. The purpose of the method is to facilitate speech recognition with visual features extracted from a mouth region. Different Active Appearance Models are employed for finding lips in video frames and for lip shape and texture statistical description. Search initialization procedure is proposed and error measure values are...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048212981]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [3300730069468581]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048216901]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048223411]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [3300730069466081]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [1011073004822831]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048223371]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048225291]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...