Filtry
wszystkich: 1968
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: ALLERGY TO IMPLANT COMPONENTS
-
In Vitro Biological Characterization of Silver-Doped Anodic Oxide Coating on Titanium
PublikacjaDespite the high biocompatibility and clinical effectiveness of Ti-based implants, surface functionalization (with complex osteointegrative/antibacterial strategies) is still required. To enhance the dental implant surface and to provide additional osteoinductive and antibacterial properties, plasma electrolytic oxidation of a pure Ti was performed using a nitrilotriacetic acid (NTA)-based Ag nanoparticles (AgNP)-loaded calcium–phosphate...
-
Skłonność do tworzenia pęknięć zimnych złączy spawanych ze stali o podwyższonej wytrzymałości wykonanych pod wodą.
PublikacjaW pracy przedstawiono zagadnienie spawalności stali 18G2A w odniesieniu do spawania pod wodą metodą lokalnej komory suchej. Zaprezentowano wyniki badań skłonności do tworzenia pęknięć zimnych metodą implant. Ustalono, że podczas spawania pod wodą stal 18G2A cechuje się zwiększoną wrażliwością na tworzenie się pęknięć zimnych w porównaniu ze spawaniem w środowisku powietrznym.
-
Sławomir Milewski prof. dr hab. inż.
OsobySławomir Milewski, urodzony w 1955 r. w Pucku (woj. pomorskie), ukończył w 1979 r. studia magisterskie na kierunku Chemia, w specjalności Chemia i Technologia Organiczna, na Wydziale Chemicznym PG. Po ukończeniu Studium Doktoranckiego w 1984 r., został zatrudniony na macierzystym wydziale w Katedrze Technologii Leków i Biochemii, początkowo na stanowisku naukowo-technicznym, a od r. 1986 jako nauczyciel akademicki. W 1985 r. uzyskał...
-
Serous adenocarcinoma, NOS - Female, 70 - Tissue image [6100730023432971]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Serous adenocarcinoma, NOS - Female, 70 - Tissue image [6100730023439261]
Dane BadawczeThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Serous adenocarcinoma, NOS - Female, 70 - Tissue image [6100730023431521]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Polyvalent Mechanical Bacterial Lysate Administration Improves the Clinical Course of Grass Pollen–Induced Allergic Rhinitis in Children: A Randomized Controlled Trial
Publikacja -
Modelowanie i badania doświadczalne implantów stosowanych w operacjach laparoskopowych
PublikacjaW pracy przedstawiono problemy modelowania implantów wszczepianych do powięzi w czasie operacji przepuklin brzusznych. Zastosowano metodę elementów skończonych w implementacj komputerowej systemu MSC.Marc.Wyniki symulacji komputerowej porównano z wynikami badań doświadczalnych implantu połączonego z powięzia zszywkami, które przeprowadzono w specjalnej, szczelnej komorze. Badany układ implant-powięź poddany był działaniu impulsowego...
-
Polynomial Chaos Expansion in Bio-and Structural Mechanics
PublikacjaThis monograph presents a probabilistic approach to modelling the mechanics of materials and structures where the modelled performance is influenced by uncertainty in the input parameters. The work is interdisciplinary and the methods described are applied to medical and civil engineering problems. The motivation for this work was the necessity of mechanics-based approaches in the modelling and simulation of implants used in the...
-
Mechanics of mesh implanted into abdominal wall under repetitive load. Experimental and numerical study
PublikacjaThere are a number of papers discussing medical and mechanical aspects of ventral hernia management. Despite intensive work on the problem understanding, recurrences of the sickness still happen too often. For that reason new aspects of the problem must be considered. In this paper, a change in the abdominal implant’s stiffness is discussed, which is caused by cyclic loading. Such loading influence abdominal implant e.g. while...
-
Polynomial Chaos Expansion in Bio- and Structural Mechanics
PublikacjaThis thesis presents a probabilistic approach to modelling the mechanics of materials and structures where the modelled performance is influenced by uncertainty in the input parameters. The work is interdisciplinary and the methods described are applied to medical and civil engineering problems. The motivation for this work was the necessity of mechanics-based approaches in the modelling and simulation of implants used in the repair...
-
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.
Publikacjarepairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...
-
pH-dependent composite coatings for controlled drug delivery system - Review
PublikacjaNowadays in case of long-term implants, the most common postoperative complications are bacterial infections, which in consequence may provoke loos- ening of the implants in the primary phase of stabilization. Bacterial infections are currently the most frequent cause of revision surgery of the implants such as hip joint endoprosthesis, knee joint endoprosthesis and dental implants. In order to provide the local and long-term antibacterial...
-
Influence of Ultrasound on the Characteristics of CaP Coatings Generated Via the Micro-arc Oxidation Process in Relation to Biomedical Engineering
PublikacjaOver the past decade, bone tissue engineering has been at the core of attention because of an increasing number of implant surgeries. The purpose of this study was to obtain coatings on titanium (Ti) implants with improved properties in terms of biomedical applications and to investigate the effect of ultrasound (US) on these properties during the micro-arc oxidation (MAO) process. The influence of various process parameters, such...
-
Cough influence on fascia-mesh system built for a hernia repair - an experimental research
PublikacjaAn experimental approach to identify stronger and weaker fixation schemes in laparoscopic ventral hernia repair is presented in the paper. Two types of implants, whose mechanical properties are significantly different and five kinds of connectors are considered. Physical models of operated hernia have been built using those materials and porcine abdominal tissue. The models have been subjected to dynamic impulse load, similar to...
-
TRANSFER OF ELECTRIC ENERGY [2023/24]
Kursy OnlineCourse content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...
-
TRANSFER OF ELECTRIC ENERGY [2022/23]
Kursy OnlineCourse content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublikacjaTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
Robotic manipulators, Lab, MiBM, st. I, sem.6 (PG_00053663) 03.2022 Fri
Kursy OnlineThe course Manipulators and Industrial Robots (laboratory) is for students of the 6th semester of a full-time bachelor's degree studies of Mechatronics. The course includes laboratory classes in the field of industrial manipulators - their construction, features, components, control, and modular robots - their programming and models.
-
Robotic manipulators, Lab, MiBM, st. I, sem.6 (PG_00053663) 03.2023
Kursy OnlineThe course Manipulators and Industrial Robots (laboratory) is for students of the 6th semester of a full-time bachelor's degree studies of Mechatronics. The course includes laboratory classes in the field of industrial manipulators - their construction, features, components, control, and modular robots - their programming and models.
-
Robotic manipulators, Lab, MiBM, st. I, sem.6 (PG_00053663) 03.2024 kopia 1
Kursy OnlineThe course Manipulators and Industrial Robots (laboratory) is for students of the 6th semester of a full-time bachelor's degree studies of Mechatronics. The course includes laboratory classes in the field of industrial manipulators - their construction, features, components, control, and modular robots - their programming and models.
-
Robotic manipulators, Lab, MiBM, st. I, sem.6 (PG_00053663) 03.2024
Kursy OnlineThe course Manipulators and Industrial Robots (laboratory) is for students of the 6th semester of a full-time bachelor's degree studies of Mechatronics. The course includes laboratory classes in the field of industrial manipulators - their construction, features, components, control, and modular robots - their programming and models.
-
Nanoindentation tests of the hydroxyapatite composite coatings applicated on titanium alloys by the electrophoretic method
Dane BadawczeCurrently, there are no metal materials that meet all biomechanical and biochemical requirements needed for long life implantable biomaterials. The main purpose of the study was to functionalize the surface of the titanium alloys used in biomaterial implants.
-
Pękanie złączy w czasie spawania i eksploatacji.
PublikacjaBadano wpływ poziomu nasycenia wodorem złączy spawanych elektrodami otulonymi na naprężenia krytyczne podczas pękania opóźnionego złączy ze stali kadłubowej. Przedstawiono możliwość określenia współczynnika intensywności naprężeń na podstawie uzyskanych wyników próby skłonności do pękania opóźnionego w próbie implant. Wartość współczynnika intensywności naprężeń określono także dla implantów jednorodnych, wykonanych z materiału...
-
Robotics, Lab, MiBM, st. II, sem.1 (PG_00057380) 03.2022 Thu
Kursy OnlineThe course Robotics (laboratory) is for students of the 1st semester of a full-time Master degree studies of Machine Design. The course includes laboratory classes in the field of industrial manipulators - their construction, features, components, control, and modular robots - their programming and models.
-
Roller burnishing
PublikacjaThe paper shows the process of roller burnishing as a method of finishing machine components. Based on own research the author presents the effects of the roller burnishing process to increase the hardness and residual stress as well as the wear and fatigue strength of burnishing components.
-
Audio codec employing frequency-derived tonality measure
PublikacjaA transform codec employing efficient algorithm for detection of spectral tonal components is presented. The tonality measure used in MPEG psychoacoustic model is replaced with the method providing adequate tonality estimates even if the tonal components are deeply frequency modulated. The reliability of hearing threshold estimated using psychoacoustic model with standardized tonality measure and the proposed one is investigated...
-
An Empirical System Loss Model for Body Area Networks in a Passenger Ferry Environment
PublikacjaThis paper presents a general empirical system loss model for estimating propagation loss in Body Area Networks in off-body communications at 2.45 GHz in a passenger ferry environment. The model is based on measurements, which were carried out in dynamic scenarios in the discotheque passenger ferry environment. The model consists of three components: mean system loss, attenuation resulting from the variable antenna position on...
-
An Empirical System Loss Model for Body Area Networks in a Passenger Ferry Environment
PublikacjaThis paper presents a general empirical system loss model for estimating propagation loss in Body Area Networks in off-body communications at 2.45 GHz in a passenger ferry environment. The model is based on measurements, which were carried out in dynamic scenarios in the discotheque passenger ferry environment. The model consists of three components: mean system loss, attenuation resulting from the variable antenna position on...
-
Mineral oil-based hydrostatic drives as the basic drive systems in the construction of offshore eqiupment projects
PublikacjaThe aim of this article is to present the components used in the production of mineral oil-based hydrostatic drives as the basic drive systems for the offshore industry. The article contains de-scriptions of the components of the said systems, with the description of their suitability for mi-neral oil operation and offshore applications.
-
Using LSTM networks to predict engine condition on large scale data processing framework
PublikacjaAs the Internet of Things technology is developing rapidly, companies have an ability to observe the health of engine components and constructed systems through collecting signals from sensors. According to output of IoT sensors, companies can build systems to predict the conditions of components. Practically the components are required to be maintained or replaced before the end of life in performing their assigned task. Predicting...
-
Problems of exact generation ofinverter output voltage
PublikacjaW pracy przedstawiono nową modyfikację modulatora szerokości impulsów. Rozważono problemy generacji dokładnej wartości napięcia wyjściowego falownika. Zaproponowano dwie metody generacji małej wartości napięcia.
-
Resistance to cold cracking of steel joints of P460NL1 steel
PublikacjaPrzedstawiono wyniki badań odporności na zimne pękanie złączy spawanych ze stali przeznaczonej do pracy pod ciśnieniem. Badano równoczesny wpływ zawartości wodoru dyfundującego i energii liniowej na naprężenie krytyczne w próbie implant dla złączy spawanych elektrodami otulonymi i drutem proszkowym w osłonie gazów ochronnych. Stwierdzono wpływ energii liniowej jak i zawartości wodoru dyfundującego na odporność na zimne pękanie...
-
Pękanie opóźnione złączy spawanych
PublikacjaPrzedstawiono badania eksperymentalne i szacunki skłonności do pękania opóźnionego złączy spawanych elektrodami otulonymi EB146 na stali kadłubowej gat. AH36. Badania prowadzono przy użyciu metody kołkowej na zbudowanym, zautomatyzowanym stanowisku pomiarowym IMPLANT 02 dla elektrod generujących różne poziomy wodoru dyfundującego (2,88-15,5 mlH/100g Fe) w złączu spawanym z użyciem technologii stosowanej w przemyśle okrętowym. Wykazano...
-
Diagnosis of bearing damage in induction motors by instantaneous power analysis
PublikacjaResearch of the machine with simulated bearing damages has been carried out, where variable load torque, simulating bearing damage, was introduced. The results show that components which can be used for bearings diagnosis appear in the spectrum of the product of current and supply voltage instantaneous values. These components are easier to identify than the components of current spectrum, which have been used so far in diagnostic...
-
Stiffness change of abdominal prosthesis Optomesh™ under cyclic loading
PublikacjaAbdominal prostheses are used in humans for abdominal wall strengthening or reconstruction. From the mechanical point of view they are membranes, so their basic mechanical property is tensile stiffness. This property is experimentally identified for a selected implant, OptomeshTM. The obtained results are described herein. Uni-axial simple and cyclic tension tests are a basis for the analysis. Both kinds of tests allowed to distinguish...
-
Kryteria oceny skłonności do pękania opóźnionego
PublikacjaPrzedstawiono wyniki badań skłonności do pękania opóźnionego określanego metodą kołkową (implant) dla złącza spawanego ręcznie elektrodami otulonymi gatunku EB146 na stali kadłubowej AH36. Określono naprężenia krytyczne i parametr pękania alfa dla kontrolowanej zawartości wodoru dyfundującego w zakresie 2,88-15,55 ml/100gFe. Wyniki badań porównano z szacunkami skłonności do pękania opartymi o metodę Ito-Besseyo i temperaturę niezbędnego...
-
Ocena kryteriów skłonności do pękania zimnego złączy spawanych.
PublikacjaPrzedstawiono wyniki badań skłonności do pękania opóźnionego określanego metodą kołkową (implant) dla złącza spawanego ręcznie elektrodami otulonymi gatunku EB146 na stali kadłubowej AH36. Określono naprężenia krytyczne dla kontrolowanej zawartości wodoru dyfundującego w zak-resie 2,88-15,55 ml/100gFe. Wyniki badań porównano z szacunkami skłonności do pękania opartymi o metodę Ito-Besseyo i temperaturę niezbędnego podgrza-nia wstępnego...
-
Funkcjonowanie zespołów napędu hydraulicznego maszyn w niskich temperaturach otoczenia
PublikacjaW pracy przedstawiono cztery warianty klasyfikacji rozruchów oziębionego napędu hydraulicznego. Pierwsza sytuacja dotyczy zagadnienia, w którym wszystkie zespoły układu napędowego wraz z olejem mają taką samą niską temperaturę podczas rozruchu. Pozostałe warianty odnoszą się do rozruchu w warunkach szoku termicznego wywołanych zasilaniem ciepłym czynnikiem roboczym oziębionych zespołów hydraulicznych. Rozruch zespołów...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublikacjaResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Koncepcja międzynarodowej konkurencyjności makrootoczenia przedsiębiorstw
PublikacjaCelem badań przedstawionych w niniejszym artykule jest opracowanie koncepcji konkurencyjności międzynarodowej (IC) krajów, której podstawą jest makroekonomiczne otoczenie przedsiębiorstw. Motywem podjęcia tych badań były poważne wady metodologii pomiaru IC gospodarek stosowanej przez Światowe Forum Ekonomiczne (WEF). WEF rekomenduje Globalny Indeks Konkurencyjności (GCI) jako globalną miarę produktywności kraju. WEF utrzymuje,...
-
Spatial variability of throughfall in a stand of Scots pine (Pinus sylvestris L.) with deciduous admixture as influenced by canopy cover and stem distance
PublikacjaVegetation cover affects the amount of precipitation, its chemical composition and its spatial distribution, and this may have implications for the distribution of water, nutrients and contaminants in the subsurface soil layer. The aim of this study was a detailed diagnosis of the spatio-temporal variability in the amount of throughfall (TF) and its chemical components in a 72-year-old pine stand with an admixture of oak and birch....
-
Impedance spectra of RC model as a result of testing pulse excitation measurement method
Dane BadawczeThe impedance spectrum of RC model object obtained using pulse excitation EIS impedance spectrosocpy measurement method. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. The object under test was built using RC components connected as Baunier model of anticorrosion coating with the following components...
-
Global sensitivity analysis of membrane model of abdominal wall with surgical mesh
PublikacjaThe paper addresses the issue of ventral hernia repair. Finite Element simulations can be helpful in the optimization of hernia parameters. A membrane abdominal wall model is proposed in two variants: a healthy one and including hernia defect repaired by implant. The models include many uncertainties, e.g. due to variability of abdominal wall, intraabdominal pressure value etc. Measuring mechanical properties with high accuracy...
-
Badania bioaktywności z wykorzystaniem komórek kościotwórczych na tytanie pokrytym chitozanem = Bioactivity studies using osteogenic cells on titanium coated with chitosan
PublikacjaChitosan is a natural polymer from the group of polysaccharides, which has found wide application in biomedical applications to induce bioactivity of implant. The studies described were carried out test imposition of chitosan membranes with varying degrees of deacetylation on the surface of titanium, and then check the bioactivity of the material in vitro, using osteogenic cells MC3T3-E1. Titanium surface before imposition of...
-
Coatings in arthroplasty [online]
PublikacjaThe modern coatings used in arthroplasty for long term implants are reviewed. The phosphate coatingsare the most popular technique to improve the bone-implant interfacial strength and promote theosseointegration. The plasma spraying, electrophoretic precipitation, powder metallurgy, ion beamsputtering, high velocity oxy-fuel (HVOF) combustion spraying, sol-gel technique, biomimeticdeposition are mostly used to obtain the phosphate,...
-
The determinants of morphology and properties of the nanohydroxyapatite coating deposited on the Ti13Zr13Nb alloy by electrophoretic techniqe
PublikacjaThe titanium and its alloys belong at present to the most preferred and commonly applied biomaterials for load- bearing implants. The surfaces of biomaterials are subjected to modification, including the hydroxyapatite coatings deposited in order to ensure corrosion resistance and better joining between an implant and a bone through the possibility of ingrowth bone into the coating. In this paper, the morphology and properties...
-
Graphene Production and Biomedical Applications: A Review
PublikacjaGraphene is a two-dimensional nanomaterial composed of carbon atoms with sp2 hybrid orbitals. Both graphene and graphene-based composite have gained broad interest among researchers because of their outstanding physiochemical, mechanical, and biological properties. Graphene production techniques are divided into top-down and bottom-up synthesis methods, of which chemical vapor deposition (CVD) is the most popular. The biomedical...
-
Analytical studies on ascosin, candicidin and levorin multicomponent antifungal antibiotic complexes. The stereostructure of ascosin A2
PublikacjaIn the class of polyene macrolides, there is a subgroup of aromatic heptaenes, which exhibit the highest antifungal activity within this type of antibiotics. Yet, due to their complex nature, aromatic heptaenes were not extensively studied and their potential as drugs is currently underexploited. Moreover, there are many inconsistencies in the literature regarding the composition and the structures of the individual components...
-
Paweł Derkacz
OsobyPawel B. Derkacz was born in Miastko, Poland, in 1993. He received the B.Sc. and M.Sc. degrees in electrical engineering from the Gdansk University of Technology (GUT), Gdansk, Poland, in 2016 and 2017, respectively. In October 2017, he joined the Faculty of Electrical and Control Engineering at GUT Gdansk. In June 2019, he joined the Grenoble Electrical Engineering Laboratory (G2Elab) at Grenoble Institute of Technology (Grenoble...