Structural Health Monitoring of Overhead Power Transmission Lines
PublikacjaStructural Health Monitoring (SHM) is a novel and continuously developing branch of science and technology that draws attention of scientists all over the world. It creates opportunities to detect, localize and identify structural damage of various types such as: line breakage, permissible sag, bolt loosening, fatigue cracking or insulator contamination. On the other hand the methods used to estimate the remaining operational...
-
Change of exhaust gases concentration for reference SOFC and SOFC with LSCNT layer fueled by biogas mixture at 750 C
Dane BadawczeThe dataset changes of exhaust gases concentrations (CH4,CO,CO2,H2) over working time for SOFC with La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer as well as reference SOFEC (unmodified). Concentrations were calculated based on the FTIR measurements and calibration curves presented in different dataset. Longterm measurements of SOFC were performed using in-house...
-
MEMS Gyro in the Context of Inertial Positionning
PublikacjaThe article undertake some vital aspect in geodesy, namely an inertial positioning problem using MEMS. Although MEMS inertial sensors offer affordable, appropriately scaled units, and though their inherent measurement noise can be relatively easily mitigated, there are still parameters due to they are not currently capable of meeting all requirements for the accurate and precise inertial positioning. The article presents crucial...
-
Structural Health Monitoring of Composite Shell Footbridge for Its Design Validation
PublikacjaThe paper presents the structural health monitoring system of the composite bridge for pedestrians and cyclists. The footbridge was designed and manufactured within the FOBRIDGE project. It is the first bridge in the world, which is classified as a consistent single element structural girder, made of sandwich shells, entirely produced in a single cycle. The developed structural health monitoring system, supported design process,...
-
Solid State Conductivity of Optimized Polypyrrole Coatings on Iron Obtained from Aqueous Sodium Salicylate Solution Determined by Impedance Spectroscopy
PublikacjaIn this work the optimization procedure for corrosion resistance, surface analysis and electrical properties of PPy-Fe electrodes have been examined. Polypyrrole (PPy) film was electrochemically synthesized in a one step process from an aqueous solution of sodium salicylate and pyrrole with certain concentrations, different parameters and type of polymerization...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublikacjaLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
ECG measurement in the bathtub - getting into the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Identyfikacja trajektorii obiektów dynamicznych w przestrzeni kartezjańskiej na podstawie informacji z wielu estymatorów stanu
PublikacjaW rozprawie przedstawiono metodologię umożliwiającą implementację rozproszonego asynchronicznego systemu wyznaczania trajektorii. System tego typu jest złożony ze zbioru tzw. węzłów (estymatorów lokalnych), które komunikują się ze sobą. Każdy węzeł wyznacza trajektorię obserwowanego obiektu/procesu na podstawie dwóch zbiorów danych. Pierwszym zbiorem są pomiary dostarczane przez skojarzone z danym...
-
DIAGNOSTYKA ŁOŻYSK SILNIKA INDUKCYJNEGO PRZY UŻYCIU POMIARU PRĄDU ZASILAJĄCEGO I WIBRACJI
PublikacjaW artykule przedstawione zostały wyniki badań diagnostycznych łożysk silnika indukcyjnego z zastosowaniem metody pomiaru prądu zasilającego oraz wibracji. Poruszone zostały problemy dotyczące poszukiwania nowej metody opartej na pomiarze i analizie prądu, która w znacznym stopniu ułatwiłaby szybkie i sprawne znalezienie uszkodzenia w maszynie, bez konieczności bezpośredniego dostępu do badanego urządzenia. Zaprezentowano rezultaty...
-
THE APPLICATION OF THE MECHANOCHEMICAL SYNTHESIS FOR THE PREPARATION OF ADVANCED CERAMICS BASED ON BARIUM TITANATE
PublikacjaIn the present study, the lead-free BaTi1-xZrxO3 (for x = 0, 0.05 and 0.15) ceramics were prepared by High-Energy Ball Milling and heat treatments. The performed X-ray, SEM and EDS measurements confirmed high purity, good quality and the expected quantitative composition of the obtained samples. The study of dielectric properties was performed by means of broadband dielectric spectroscopy at the frequency ranging from 0.1 Hz to...
-
ANALYSIS OF DIESEL OIL SPECIFIC HEAT IMPACT FOR OPERATION OF THE SUPPLY PUMP
PublikacjaThe article describes a test rig that allows the measurement of fuel oil specific heat changes based on the cooling time of liquids. After that, by analysing the test results, a research hypothesis was created and verified. The hypothesis is that the specific heat energy of fuel oil impact the operation of the circulation pump.
-
Impedance and cyclic voltammetry studies of GPLA electrodes after laser ablation
Dane BadawczeThe 3D printed GPLA electrodes present a brand new opportunity for electrode material for electrochemical biosensors. In order for the electrodes to be considered viable for electroanalysis studies, the pretreatment procedure must be applied in order to etch PLA matrix and reveal graphene filler. The following dataset presents an approach towards such...
-
Paweł Tysiąc dr inż.
Osobydr inż. Paweł Tysiąc Urodził się 25 marca 1992 w Gdańsku. Po ukończeniu Gimnazjum nr 32 uczęszczał do VIII Liceum Ogólnokształcącego im. Komisji Edukacji Narodowej w Gdańsku, klasy o profilu matematyczno-geograficznym, uzyskując w 2011 roku świadectwo dojrzałości. Następnie w latach 2011-2016 kontynuował naukę na Wydziale Inżynierii Lądowej i Środowiska Politechniki Gdańskiej. Ukończył studia I stopnia w specjalności Geodezja...
-
Estimation of time-frequency complex phase-based speech attributes using narrow band filter banks
PublikacjaIn this paper, we present nonlinear estimators of nonstationary and multicomponent signal attributes (parameters, properties) which are instantaneous frequency, spectral (or group) delay, and chirp-rate (also known as instantaneous frequency slope). We estimate all of these distributions in the time-frequency domain using both finite and infinite impulse response (FIR and IIR) narrow band filers for speech analysis. Then, we present...
-
Call Control Evaluation in ASON/GMPLS Architecture
PublikacjaThe Automatically Switched Optical Network (ASON) utilizing Generalized Multi–Protocol Label Switching (GMPLS) protocols named as ASON/GMPLS is one of the propositions of Next Generation Network. The basic assumption of ASON control plane is a separation of call control from connection control. The control plane is divided into call control and connection control components. Presented work regards the problem of call control evaluation...
-
TIME-AND-SPACE STRUCTURE OF FORCE-DRIVEN RIGID SPHEREWAVEFIELD
PublikacjaThis paper introduces a time-domain, causality-inspired description of a vector-source acoustic wavefield of arbitrary time evolution, where a sphere is a practical realisation of quasi-point contact surface without which a point force would not be able to exert an impact onto non-viscous fluid. At every space location, the resulting acoustic field is described by a pair of physical variables characterising the time evolution of...
-
Selected properties and parameters of radio channel impulse response estimation in ISM 2.4 GHz band
PublikacjaThe article presents experimental research indicating that the impulse response of the communication channel, determined in practice, are not of an universal character, but only represent its approximate value for the frequency on which this measurement was made. Phases for each of the replicas of the measurement signal were determined during the analysis of the received signals in the baseband. Phase changes of individual replicas...
-
Measurements of the rms currents in two phases in a ship power station with two generators operating in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the rms...
-
Measurements of the fundamental harmonic frequency of voltages on main bars in a ship power station
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the fundamental...
-
Measurements of the rms voltages on main bars in a ship power station with two generators operating in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the rms...
-
Determination of rectification corrections for semi gantry crane rail axes in the local 3D coordinate system
PublikacjaElectronic tacheometers are currently the standard instruments used in geodetic work, including also geodetic engineering measurements. The main advantage connected with this equipment is among others high accuracy of the measurement and thus high accuracy of the final determinations represented for example by the points’ coordinates. One of many applications of the tacheometers is the measurement of crane rail axes. This measurement...
-
Graphene field-effect transistor application for flow sensing
PublikacjaMicroflow sensors offer great potential for applications in microfluidics and lab-on-a-chip systems. However, thermal-based sensors, which are commonly used in modern flow sensing technology, are mainly made of materials with positive temperature coefficients (PTC) and suffer from a self-heating effect and slow response time. Therefore, the design of novel devices and careful selection of materials are required to improve the overall...
-
Tailoring the electrochemical degradation of iron protected with polypyrrole films for biodegradable cardiovascular stents
PublikacjaThe degradation of polypyrrole (PPy) coated iron is studied in phosphate buffer saline solution at 37 °C by odd random phase multisine electrochemical impedance spectroscopy (ORP-EIS). PPy is electropolymerized with anti-inflammatory salicylates incorporated in the film, as a drug release system. The modelling of EIS over time provides the quantitative description of the corrosion behaviour of the material. Thus, the reliable...
-
Communication Model Order Reduction in Hybrid Methods Involving Generalized Impedance Matrix
PublikacjaA novel strategy for the efficient analysis of frequency-domain scattering electromagnetic problems in open and closed domains is presented. A fully automatic model-order reduction technique, called the enhanced reduced-basis method, is applied to increase the efficiency of the hybrid approach, which combines the finite-element and mode-matching methods. Numerical tests show that the proposed algorithm yields reliable and highly...
-
Variable‐fidelity modeling of antenna input characteristics using domain confinement and two‐stage Gaussian process regression surrogates
PublikacjaThe major bottleneck of electromagnetic (EM)-driven antenna design is the high CPU cost of massive simulations required by parametric optimization, uncertainty quantification, or robust design procedures. Fast surrogate models may be employed to mitigate this issue to a certain extent. Unfortunately, the curse of dimensionality is a serious limiting factor, hindering the construction of conventional data-driven models valid over...
-
Optical Detection of Ketoprofen by Its Electropolymerization on an Indium Tin Oxide-Coated Optical Fiber Probe
PublikacjaIn this work an application of optical fiber sensors for real-time optical monitoring of electrochemical deposition of ketoprofen during its anodic oxidation is discussed. The sensors were fabricated by reactive magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. ITO tuned in optical properties and thickness allows for achieving a lossy-mode resonance (LMR) phenomenon and it can be...
-
Stochastic resonance in measurements
PublikacjaNoise is usually associated with the negative phenomenon, hampering the measurements data and their analysis. This view has been broken in the '80s when the phenomenon of stochastic resonance (Stochastic Resonance - SR) was discovered. It is a phenomenon that occurs in nonlinear dynamic measurement systems when the selected input noise can optimize system performance. SR became a way to improve efficiency of weak signals detection....
-
Application of guided wave propagation in diagnostics of steel bridge components
PublikacjaEarly detection of potential defects and identification of their location are necessary to ensure safe, reliable and long-term use of engineering structures. Non-destructive diagnostic tests based on guided wave propagation are becoming more popular because of the possibility to inspect large areas during a single measurement with a small number of sensors. The aim of this study is the application of guided wave propagation in...
-
Road surface roughness estimation employing integrated position and acceleration sensor
PublikacjaAssessment of a surface quality being an essential task for the authorities supervising the roads provides the subject of the paper. Information about riding quality of a pavement, important for drivers, both in terms of their comfort and safety is collected during experiments employing mobile sensors. The paper describes the use of a miniature position and acceleration sensor for evaluation of the roughness of the road surface....
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublikacjaThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublikacjaThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
A new approach to active noise and vibration control - [Part II: unknown frequency case]
PublikacjaThis paper presents a new approach to rejection of complex-valued sinusoidal disturbances acting at the output of a discrete-time stable linear plant with unknown and possibly timevarying dynamics. It is assumed that both the instantaneous frequency of the sinusoidal disturbance and its amplitude may be slowly varying with time and that the output signal is contaminated with wideband measurement noise. It is not assumed that a...
-
Experimental determination of H2 mass stopping powers for low-energy electrons
PublikacjaWe present experimental mass stopping powers of electrons in gaseous H2 obtained with an electron time- of-flight spectrometer, for the incident electron energy range of 11 to 25 eV. In our procedure, the average energy loss is derived from conversion of the measured electron time-of-flight spectra into equivalent electron energy-loss spectra. Our present results are compared with the only available experimental measurement and...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...