Filtry
wszystkich: 1872
-
Katalog
- Publikacje 1340 wyników po odfiltrowaniu
- Czasopisma 68 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Osoby 22 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Kursy Online 38 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 400 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: heart assist devices
-
Photoplethysmographic Time-Domain Heart Rate Measurement Algorithm for Resource-Constrained Wearable Devices and its Implementation
PublikacjaThis paper presents an algorithm for the measurement of the human heart rate, using photoplethysmography (PPG), i.e., the detection of the light at the skin surface. The signal from the PPG sensor is processed in time-domain; the peaks in the preprocessed and conditioned PPG waveform are detected by using a peak detection algorithm to find the heart rate in real time. Apart from the PPG sensor, the accelerometer is also used to...
-
Experimental Investigation of the Performance of an Innovative Implantable Left Ventricular Assist Device—Proof of Concept
PublikacjaThis paper presents the results of experimental performance of an innovative left ventricular assist device working on a specially designed test stand. The introduced invention is mainly applied for supporting the heart in patients with end-stage heart failure accompanied by mitral valve regurgitation and pulmonary hypertension. Moreover, the developed device has the form of a flexible balloon forming an intracardiac inert gas-filled...
-
Innovative Implantable Left Ventricular Assist Device—Performance under Various Resistances and Operating Frequency Conditions
PublikacjaThis paper presents the operation of an innovative left ventricular assist device under various resistances and operating frequencies. The operating principle of the device is based on pulsatile blood flow, which is forced by a suction–discharge device pumping helium into a set of intra-cardiac balloons. In this way, the ejection fraction of the left ventricle is increased, and the mitral valve is additionally occluded. What is...
-
Effect of Vascular Lumen Reduction on the Performance and Energy Consumption of an Innovative Implantable LVAD
PublikacjaThis paper presents the results of a study on the effect of vascular lumen reduction on the performance of an innovative implantable LVAD (left ventricular assist device). It details the pressures in the individual cardiac chambers as a function of device frequency. In addition, mass flow rates and energy consumption of the device are examined, varying with lumen reduction and operating frequency. While the lumen reduction of the...
-
IR and microscopic studies of polyurethane surface in the polish extracorporeal ventricular assist device POLVAD-MEV
PublikacjaPurpose: The aim of this article is to show results of IR measurements and microscopicanalysis performed on layers prepared with dissolved VAD fragments and pieces ofventricular assist devices cut out of from determined VAD sectors.Design/methodology/approach: The objects of the study have been POLVAD-MEVVADs from POLCAS system. Four ventricular assist devices POLVAD-MEV have beeninvestigated with use M80 SPECORD IR spectrophotometer...
-
Insight into heart regeneration
PublikacjaThe mammalian heart is thought to be incapable of regeneration because of the limited ability of cardiomyocytes. to proliferate. However, it has been recently shown that the neonatal murine heart is able to restore its normal function after coronary artery ligation or even partial resection. Unfortunately, this feature is lost in a few days after birth, although lower vertebrates as zebrafish or newt, retain this ability until adulthood. Therefore,...
-
A System for Heart Sounds Classification
PublikacjaThe future of quick and efficient disease diagnosis lays in the development of reliable non-invasive methods. As for the cardiac diseases – one of the major causes of death around the globe – a concept of an electronic stethoscope equipped with an automatic heart tone identification system appears to be the best solution. Thanks to the advancement in technology, the quality of phonocardiography signals is no longer an issue. However,...
-
A machine learning approach to classifying New York Heart Association (NYHA) heart failure
PublikacjaAccording to the European Society of Cardiology, globally the number of patients with heart failure nearly doubled from 33.5 million in 1990 to 64.3 million in 2017, and is further projected to increase dramatically in this decade, still remaining a leading cause of morbidity and mortality. One of the most frequently applied heart failure classification systems that physicians use is the New York Heart Association (NYHA) Functional...
-
EUROPEAN HEART JOURNAL
Czasopisma -
Ordinal pattern statistics for the assessment of heart rate variability
PublikacjaThe recognition of all main features of a healthy heart rhythm (the so-called sinus rhythm) is still one of the biggest challenges in contemporary cardiology. Recently the interesting physiological phenomenon of heart rate asymmetry has been observed. This phenomenon is related to unbalanced contributions of heart rate decelerations and accelerations to heart rate variability. In this paper we apply methods based on the concept...
-
Entropy Measures of heart rate variability for short ECG datasets in patients with congestive heart failure
PublikacjaWe investigated the usefulness of entropy measures calculated for short ECG series in distinguishing healthy subjects from patients with congestive heart failure (CHF). Four entropy measures were tested: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (Fuzzy En) and Permutation Entropy (PE), each computed for ECG series of 1000, 500, 250 and 100 RR intervals. We found that with a reduction of the data set length...
-
Entropy measures of heart rate variability for short ECG datasets in patients with congestive heart failure
PublikacjaWe investigated the usefulness of entropy measures calculated for short ECG series in distinguishing healthy subjects from patients with congestive heart failure (CHF). Four entropy measures were tested: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (FuzzyEn) and Permutation Entropy (PE), each computed for ECG series of 1000, 500, 250 and 100 RR intervals. We found that with a reduction of the data set length...
-
COMPOSITE MATERIAL SELECTION FOR A PATIENT TRANSFER ASSIST DEVICE
PublikacjaLaminates - layered composites containing at least two elements (matrix and reinforcement) widely used in industry have also found their usage in medicine. Their main feature is the ability to modify the material in order to obtain the required properties. Depending on the needs, we can modify reinforcement, type of resin or the method of bonding substrates. Commonly used fibers are: carbon fiber, glass and aramid fibers; resins...
-
Semiconductor Devices
Kursy Onlinewesja angielskojęzyczna przedmiotu Przyrządy Półprzewodnikowe dla studentów z programu Erasmus
-
Cross-talk Between the Heart and Arteries in Older 65+ Adults
PublikacjaRegulatory synchronization between the heart and the arterial walls is essential for optimal blood delivery to tissues. We investigated functional coherence between heart rhythm and aortic wall compliance in 30 volunteers aged 65 – 74. ECG and carotid and iliac pulse-wave were recorded and digitized at 2 kHz. Carotid-femoral pulse-wave transit time (cfTT) which reflex aortic compliance was assessed using the intersecting tangent...
-
Generalised heart rate statistics reveal neurally mediated homeostasis transients
PublikacjaDistributions of accelerations and decelerations, obtained from increments of heart rate recorded during a head-up tilt table (HUTT) test provide short-term characterization of the complex cardiovascular response to a rapid controlled dysregulation of homeostasis. A generalised statistic is proposed for evaluating the neural reflexes responsible for restoring the homeostatic dynamics. An evaluation of the effects on heart rate...
-
Kardiologia Polska
Czasopisma -
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Microfluidic devices for photo-and spectroelectrochemical applications
PublikacjaThe review presents recent developments in electrochemical devices for photo- and spectroelectrochemical investigations, with the emphasis on miniaturization (i.e., nanointerdigitated complementary metal-oxide-semiconductor devices, micro- and nano-porous silicon membranes or microoptoelectromechanical systems), silica glass/microreactors (i.e., plasmonic, Raman spectroscopy or optical microcavities) or polymer-based devices (i.e.,...
-
Relationship between heart rate variability, blood pressure and arterial wall properties during air and oxygen breathing in healthy subjects
PublikacjaPrevious studies reported that normobaric hyperoxia influences heart rate, arterial pressure, cardiac output and systemic vascular resistance, but the mechanisms underlying these changes are still not fully understood. Several factors are considered including degeneration of endothelium-derived nitric oxide by reactive oxygen species, the impact of oxygen-free radicals on tissues and alterations of autonomic nervous system function....
-
Chronographic Imprint of Age-Induced Alterations in Heart Rate Dynamical Organization
PublikacjaBeat-to-beat changes in the heart period are transformed into a network of increments between subsequent RR-intervals, which enables graphical descriptions of short-term heart period variability. Three types of such descriptions are considered: (1) network graphs arising from a set of vertices and directed edges, (2) contour plots of adjacency matrices A, representing the networks and transition matrices T, resulting from A, and (3)...
-
Visualization of short-term heart period variability with network tools as a method for quantifying autonomic drive
PublikacjaWe argue that network methods are successful in detecting nonlinear properties in the dynamics of autonomic nocturnal regulation in short-term variability. Two modes of visualization of networks constructed from RR-increments are proposed. The first is based on the handling of a state space. The state space of RR-increments can be modified by a bin size used to code a signal and by the role of a given vertex as the representation...
-
Innovative rehabilitation lifts – mechanics in medical devices
PublikacjaMechanical devices are now widely used in physiotherapy and other rehabilitation processes. Particular importance is attached to devices enabling easy and effective transport of disabled people. The article presents innovative designs of rehabilitation lifts offered by the Polish manufacturer of lifts and medical accessories, LeviCare company. Moreover, the main assumptions of the research and development project implemented by...
-
Wavelet-based denoising method for real phonocardiography signal recorded by mobile devices in noisy environment
PublikacjaThe main obstacle in development of intelligent autodiagnosis medical systems based on the analysis of phonocardiography (PCG) signals is noise. The noise can be caused by digestive and respiration sounds, movements or even signals from the surrounding environment and it is characterized by wide frequency and intensity spectrum. This spectrum overlaps the heart tones spectrum, which makes the problem of PCG signal filtrating complex....
-
Tuning of the finesse coefficient of optoelectronic devices
PublikacjaOptoelectronic devices attracted considerable attention in many branches of science and technology, which can be attributed to their unique properties. Many of them use optical cavities which parameters can be adopted to specific requirements. This thesis investigates the introduction of diamond structures (nitrogen-doped diamond film, boron-doped diamond film, undoped diamond sheet) to optical cavities to tune their finesse coefficient....
-
Tripping limitations of residual current devices in photovoltaic installations
PublikacjaIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Entropy Measures in the Assessment of Heart Rate Variability in Patients with Cardiodepressive Vasovagal Syncope
PublikacjaSample entropy (SampEn) was reported to be useful in the assessment of the complexity of heart rate dynamics. Permutation entropy (PermEn) is a new measure based on the concept of order and was previously shown to be accurate for short, non-stationary datasets. The aim of the present study is to assess if SampEn and PermEn obtained from baseline recordings might differentiate patients with various outcomes of the head-up tilt test...
-
Invasive Assessment of the Myocardial Microcirculation during Beating Heart Coronary Artery Bypass Grafting
PublikacjaCoronary artery bypass grafting may be associated with several cardiac complications, including ischemia, acute myocardial infarction, arrhythmias, or hemodynamic instability. Accumulating evidence suggests that well-developed coronary collateral circulation may protect against adverse effects, including myocardial ischemia. Assessment of myocardial microvascular perfusion is, therefore, of great clinical interest in beating heart...
-
Amplifying the Randomness of Weak Sources Correlated With Devices
PublikacjaThe problem of device-independent randomness amplification against no-signaling adversaries has so far been studied under the assumption that the weak source of randomness is uncorrelated with the (quantum) devices used in the amplification procedure. In this paper, we relax this assumption, and reconsider the original protocol of Colbeck and Renner using a Santha-Vazirani (SV) source. To do so, we introduce an SV-like condition...
-
Identification of Optocoupler Devices with RTS Noise
PublikacjaThe results of noise measurements in low frequency range for CNY 17 type optocouplers are presented. The research were carried out on devices with different values of Current Transfer Ratio (CTR). The methods for identification of Random Telegraph Signal (RTS) in noise signal of optocouplers were proposed. It was found that the Noise Scattering Pattern method (NSP method) enables to identify RTS noise as non-Gaussian component...
-
Persistent homology as a new method of the assessment of heart rate variability
PublikacjaHeart rate variability (hrv) is a physiological phenomenon of the variation in the length of the time interval between consecutive heartbeats. In many cases it could be an indicator of the development of pathological states. The classical approach to the analysis of hrv includes time domain methods and frequency domain methods. However, attempts are still being made to define new and more effective hrv assessment tools. Persistent...
-
Modelling the malware propagation in mobile computer devices
PublikacjaNowadays malware is a major threat to the security of cyber activities. The rapid develop- ment of the Internet and the progressive implementation of the Internet of Things (IoT) increase the security needs of networks. This research presents a theoretical model of malware propagation for mobile computer devices. It is based on the susceptible-exposed- infected-recovered-susceptible (SEIRS) epidemic model. The scheme is based on...
-
Time-current tripping curves of arc fault detection devices
PublikacjaTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Comparison of EHD devices with parallel and in series spiked electrodes
PublikacjaIn this paper two electrohydrodynamic (EHD) devices for gas pumping and cleaning are presented. In both cases to induce an airflow in these EHD devices corona discharge was used. The discharge was generated between the spiked electrodes set parallel (the first case) or in series (the second case) and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device....
-
Slurry Erosion -Design of Test Devices
PublikacjaDegradation of material caused by impacts of a solid particle (erodent) suspended in a liquid is called slurry erosion and is a major problem in the hydropower and maritime industry. Slurry erosion depends on many factors, e.g. liquid and erodent velocity, size, shape, angle of impact, hardness and number of erodents, and strength of a target material. The various types of test devices have been designed to investigate an effect...
-
Materials for energy storage devices
Kursy OnlineKurs dotyczy zagadnień inżynierii materiałowej, elektrochemii, fizykochemii nanotechnologii materiałów stosowanych w budowaniu urządzeń elektrochemicznych do magazynowania i konwersji energii w urządzeniach. Prowadzony jest w języku angielskim.
-
Independent Association Between Plasma Leptin Levels and Heart Rate in Heart Transplant Recipients
Publikacja -
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Detection of high frequency current components by residual current devices
PublikacjaThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Devices for the production of reference gas mixtures
PublikacjaFor many years there has been growing demand for gaseous reference materials, which is connected with development in many fields of science and technology. As a result, new methodological and instrumental solutions appear that can be used for this purpose. Appropriate quality assurance/quality control (QA/QC) must be used to make sure that measurement data are a reliable source of information. Reference materials are a significant...
-
Optoelectronic Devices
Publikacja -
Residual current devices in electric vehicles charging installations
PublikacjaThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Functionality of road safety devices - identification and analysis of factors
PublikacjaRoad safety devices are designed to protect road users from the risk of injury or death. The principal type of restraint is the safety barrier. Deployed on sites with the highest risk of run-off-road accidents, safety barriers are mostly found on bridges, flyovers, central reservations, and on road edges which have fixed obstacles next to them. If properly designed and installed, safety barriers just as other road safety devices,...
-
Influence of dipoles on the recombination in organic photovoltaic devices
PublikacjaAlthough organic compounds are promising materials to use them in photovoltaic devices, the efficiencies of organic solar cells are still lower in comparison to inorganic photocells. The recombination of charge carriers leads to the loss of photocurrent, therefore a detailed theoretical description of this process is required. In the present work, an influence of interface dipoles on the recombination process is discussed. We show...
-
Nonreciprocal Devices Utilizing Longitudinally Magnetized Ferrite Coupled Lines
PublikacjaThis chapter presents authors’ recent research on the nonreciprocal devices utilizing longitudinally magnetized ferrite coupled line (FCL) junction. The principle of operation of FCL junction is explained and the hybrid techniques of analysis are shown. Numerical and experimental results concerning the nonreciprocal devices utilizing the different configurations of FCL junctions are presented and discussed.
-
The effect of current delay angle on tripping of residual current devices
PublikacjaPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Health monitoring services based on off-the-shelf mobile devices
PublikacjaDevelopment of health monitoring systems usually involves usage of dedicated devices with provided guarantees in terms of their reliability. Those devices raise the cost of the whole system, because of which such platforms are limited only to specific areas and constrained number of users. Usage of off-the- shelf devices could lower the cost and bring those systems to the masses. The paper covers possible uses of common off-the-shelf...
-
Mobile devices and computing cloud resources allocation for interactive applications
PublikacjaUsing mobile devices such as smartphones or iPads for various interactive applications is currently very common. In the case of complex applications, e.g. chess games, the capabilities of these devices are insufficient to run the application in real time. One of the solutions is to use cloud computing. However, there is an optimization problem of mobile device and cloud resources allocation. An iterative heuristic algorithm for...
-
A new nethod for RTS noise of semiconductor devices identification
PublikacjaIn the paper, a new method, called the noise scatterin pattern method (NSP method), for random telegraph signal noise identyfication in the inherent noise of semiconductor devices is described. A block diagram of a noise measurement system based on the NSP method is presented. Examples of patterns of the NSP method are presented.
-
Number of customers using only mobile devices (so-called "mobile only") - 2017
Dane BadawczeThe number of users who only use mobile devices is also growing (excluding access via desktop computers and people who manage to order current transactions in traditional bank branches). At the end of the fourth quarter 2017, there were 2.2 million such people - an increase by 434 thousand. compared to previous year.