Wyniki wyszukiwania dla: measuring
-
Exhaust gas temperature measurements in diagnostics of turbocharged marine internal combustion engines. Part I. Standard measurements.
PublikacjaThe article discusses the problem of diagnostic informativeness of exhaust gas temperature measurements in turbocharged marine internal combustion engines. Theoretical principles of the process of exhaust gas flow in turbocharger inlet channels are analysed in its dynamic and energetic aspects. Diagnostic parameters are defined which enable to formulate general evaluation of technical condition of the engine based on standard...
-
A LUMPED-CIRCUIT MODEL OF CIRCULAR PISTON TRANSDUCER FOR MODELING ITS PERFORMANCE IN DUAL FREQUENCY OPERATING MODES
PublikacjaThe paper presents novel network equivalent circuit of piezoceramic circular disc transducer that takes into account thickness and ra dial mode of vibrations. The starting point of the analysis is 4-port description of circular disc element representing the solution of wave equation set in radial and thickness directions. Th e approximate solution for harmonic case is represented in the form of 4x4 matrix, which is syn thesized...
-
Diagnosis of Damage in a Steel Tank with Self-Supported Roof through Numerical Analysis
PublikacjaThe safety of civil engineering structures is one of the most important issues of building industry. That is why the assessment of the damage-involved structural response has recently become of major concern to engineers. Among a number of different approaches to diagnosis of damage, the method of measuring the changes in natural frequencies is considered to be one of the most effective indicators of global damage. From the practical...
-
Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry
PublikacjaSolid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about...
-
Open extensive IoT research and measurement infrastructure for remote collection and automatic analysis of environmental data.
PublikacjaInternet of Things devices that send small amounts of data do not need high bit rates as it is the range that is more crucial for them. The use of popular, unlicensed 2.4 GHz and 5 GHz bands is fairly legally enforced (transmission power above power limits cannot be increased). In addition, waves of this length are very diffiult to propagate under field conditions (e.g. in urban areas). The market response to these needs are the...
-
A Highly Sensitive Planar Microwave Sensor for Detecting Direction and Angle of Rotation
PublikacjaThis article presents a technique based on a modified complementary split-ring resonator (CSRR) to detect angular displacement and direction of rotation with high resolution and sensitivity over a wide dynamic range. The proposed microwave planar sensor takes advantage of the asymmetry of the sensor geometry and measures the angle of rotation in terms of the change in the relative phase of the reflection coefficients. The sensor...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublikacjaFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Thermal and economic investigation of straight and U-bend double tube heat exchanger with coiled wire turbulator
PublikacjaExperimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800–9000 – on the shell side, for a constant cold water temperature of 9 ◦C and hot water of 50 ◦C. The heat exchangers were made from copper tubes with...
-
Possible quadrupole-order-driven commensurate-incommensurate phase transition in B20 CoGe
PublikacjaThe B20-type cobalt germanide CoGe was investigated by measuring the specific heat, resistivity, and 59Co nuclear magnetic resonance (NMR).We observed a phase transition at TQ = 13.7 K, evidenced by a very narrow peak of the specific heat and sharp changes of the nuclear spin-spin (T −1 2 ) and spin-lattice (T −1 1 ) relaxation rates. The fact that the entropy release is extremely small and the Knight shift is almost independent...
-
Seismic performance evaluation of steel buckling-restrained braced frames including SMA materials
PublikacjaThe permanent deformation of the building after seismic excitations can be determined by the Maximum Residual Interstory Drift Ratio (MR-IDR), which may be used for measuring the damage states. Low-post yield stiffness of the steel buckling-restrained braced frame (BRBF) makes this system vulnerable to large MR-IDR after a severe earthquake event. To overcome this issue, this paper investigates the seismic limit state performances...
-
Reduction in Errors in Roughness Evaluation with an Accurate Definition of the S-L Surface
PublikacjaCharacterization of surface topography, roughly divided into measurement and data analysis, can be valuable in the process of validation of the tribological performance of machined parts. Surface topography, especially the roughness, can respond straightly to the machining process and, in some cases, is defined as a fingerprint of the manufacturing. When considering the high precision of surface topography studies, the definition...
-
Respiratory Rate Estimation Based on Detected Mask Area in Thermal Images
PublikacjaThe popularity of non-contact methods of measuring vital signs, particularly respiratory rate, has increased during the SARS-COV-2 pandemic. Breathing parameters can be estimated by analysis of temperature changes observed in thermal images of nostrils or mouth regions. However, wearing virus-protection face masks prevents direct detection of such face regions. In this work, we propose to use an automatic mask detection approach...
-
Changes in the Global Competitiveness Index 4.0 Methodology: The Improved Approach of Competitiveness Benchmarking
PublikacjaThe Global Competitiveness Index (GCI) developed by the World Economic Forum (WEF) is used as a standard for measuring a country’s competitiveness. However, in literature, the GCI has been accused of numerous methodological flaws. Consequently, in 2018, the WEF introduced significant methodological changes. This study aims to examine whether the methodological modifications in the GCI’s structure increase its ability to capture...
-
Tensile modulus of human orbital wall bones cut in sagittal and coronal planes
PublikacjaIn the current research, 68 specimens of orbital superior and/or medial walls taken from 33 human cadavers (12 females, 21 males) were subjected to uniaxial tension untill fracture. The samples were cut in the coronal (38 specimens) and sagittal (30 specimens) planes of the orbital wall. Apparent density (ρapp), tensile Young’s modulus (E-modulus) and ultimate tensile strength (UTS) were identified. Innovative test protocols were...
-
Microwave Characterization of Dielectric Sheets in a Plano-Concave Fabry-Perot Open Resonator
PublikacjaDespite its long history, a double-concave (DC) Fabry-Perot open resonator (FPOR) has recently gained popularity in the characterization of dielectrics in the 20–110 GHz range, mainly due to such novel accomplishments as full automation of the measurement process and the development of even ore accurate and computationally efficient electromagnetic model. However, it has been discovered that such a DC resonator suffers from unwanted...
-
Investigation method of large-volume tire with mobile test rig
PublikacjaThe goal of this research is to develop the tire test method and mobile tire test rig. The test rig enables measurement of tire properties as stiffness and viscous damping in vertical direction, and tire–ground characteristics on the asphalt rigid surface. The tire-ground characteristics are measured by force and a torque measurement hub. The design, calibration and the algorithm for calculating the forces in the wheel center are...
-
Satellite Laser Ranging technique as a tool for the determination of the Schwarzschild, de Sitter and Lense-Thirring effects
PublikacjaSatellite Laser Ranging (SLR) is a modern technique used in various research areas and applications related to geodesy and geodynamics. It is commonly used for tasks such as establishing the International Terrestrial Reference Frame (ITRF), monitoring Earth Orientation Parameters (EOP), determining the geocenter, measuring fundamental physical constants, calibrating microwave tracking techniques, conducting time transfer experiments,...
-
FEM modelling of screw displacement pile interaction with subsoil
PublikacjaPredicting the-settlement characteristics of piles is an important element in the designing of pile foundations. The most reliable method in evaluating pile-soil interaction is the static load test, preferably performed with instrumentation for measuring shaft and pile base resistances. This, however, is a mostly post-implementation test. In the design phase, prediction methods are needed, in which numerical simulations play an...
-
Instantaneous power signal measurements for bearing diagnostics
Dane BadawczeBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Systemowe ryzyko płynności w polskim systemie bankowym – determinanty i trendy
PublikacjaCelem rozprawy jest określenie metod pomiaru systemowego ryzyka płynności oraz pomiar tego ryzyka dla polskiego systemu bankowego za pomocą zaproponowanych metod, w oparciu o dostępne dane. Do celów rozprawy zaliczyć należy również przedstawienie problemu systemowego ryzyka płynności od strony jego wpływu na gospodarkę. Zgodnie z hipotezą główną, systemowe ryzyko płynności w polskim systemie bankowym w latach 1996-2012 wzrosło....
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016643391]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [329073001664631]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
B-cell lymphoma, NOS - Unknown, 79 - Tissue image [32907300166181]
Dane BadawczeThis is the histopathological image of ACCESSORY SINUSES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016648301]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
B-cell lymphoma, NOS - Unknown, 79 - Tissue image [3290730016627381]
Dane BadawczeThis is the histopathological image of ACCESSORY SINUSES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016643821]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016642621]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016648991]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016648291]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [329073001664881]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016645571]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016643161]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016647091]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016641851]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016641471]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Teratoma, malignant, NOS - Female, 39 - Tissue image [3300730069396001]
Dane BadawczeThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Oligodendroglioma, NOS - Unknown, 37 - Tissue image [3290730016647161]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Self-competence and histrionic self-presentation style
Dane BadawczeThe database contains the results from N = 2642 respondents who answered demographic questions and completed two questionnaires measuring the general self-competence and the histrionic self-presentation style. The concept of self-competence is considered as a person’s perception of their own ability to behave such that tasks are successfully completed....
-
Diagnostyka łożysk silnika indukcyjnego na podstawie prądu zasilającego przy użyciu sztucznych sieci neuronowych
PublikacjaW artykule zawarto wyniki badań dotyczące diagnostyki łożysk silnika indukcyjnego na podstawie pomiarów prądu zasilającego z wykorzystaniem sztucznych sieci neuronowych. Zaprezentowano wyniki uczenia sieci oraz rezultaty testów przeprowadzonych na danych spoza zbioru uczącego. Badania wykonane zostały na obiektach z celowo wprowadzonymi uszkodzeniami łożysk. Przedstawiona nowa koncepcja zakłada użycie zestawu sieci neuronowych...
-
Doing Well by Doing Good- CSR in a Global Context
PublikacjaNowadays, there is a general understanding that stakeholders are crucial for the successful enterprise. There is also a need to think about Corporate Social Responsibility (CSR) in a global context. Never before corporations enjoyed so much power and authority. Corporations need to evolve, re-think their strategies and change their processes accordingly. However, as of now, there is no agreed way of measuring overall sustainability...
-
Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film
PublikacjaThe fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD...
-
Novel digitally controlled drive for the vibratory conveyors
PublikacjaThe presented vibratory conveyors is used in the industry for continuous transportation of loose substances over short distances (2-10 m). The conveyor is applied for transportation in aseptic conditions. To obtain high efficiency for granulatedmass with different size of grain and different physical properties it is necessary to set the appropriate vibration amplitudeindependently of vibration frequency. This is not possible with...
-
Determination of polybrominated diphenyl ethers in house dust using standard addition method and gas chromatography with electron capture and mass spectrometric detection
PublikacjaMonitoring of the environmental fate of polybrominated diphenyl ethers (PBDEs) involves determination of their concentration in air, airborne particles and settled dust. This requires the implementation of appropriate analytical tools like measuring instruments, reference materials and analytical procedures. In this study an analytical procedure was developed for determining PBDEs in samples with a complex matrix composition. The...
-
Nanocrystalline diamond microelectrode on fused silica optical fibers for electrochemical and optical sensing
PublikacjaFabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrode on fused silica single mode optical fiber has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with the mean grain size in the range of 100-250...
-
Determining the noise impact on hearing using psychoacoustical noise dosimeter
PublikacjaThis research study presents the designed noise dosimeter based on psychoacoustical properties of the human hearing system and, at the same time. evaluation of time and frequency characteristics of noise. The designed noise dosimeter enables assessing temporary threshold shift (TTS) in critical hands in real time. In this way it is possible monitoring the hearing threshold shift continuously for people who stay in the harmful noise...
-
Intermolecular Interactions as a Measure of Dapsone Solubility in Neat Solvents and Binary Solvent Mixtures
PublikacjaDapsone is an effective antibacterial drug used to treat a variety of conditions. However, the aqueous solubility of this drug is limited, as is its permeability. This study expands the available solubility data pool for dapsone by measuring its solubility in several pure organic solvents: N-methyl-2-pyrrolidone (CAS: 872-50-4), dimethyl sulfoxide (CAS: 67-68-5), 4-formylmorpholine (CAS: 4394-85-8), tetraethylene pentamine (CAS:...
-
Methodology for Carrying Out Measurements of the Tombolo Geomorphic Landform Using Unmanned Aerial and Surface Vehicles near Sopot Pier, Poland
PublikacjaThe human impact on the ecosystem has been particularly evident in the last century; it transforms the Earth’s surface on an unprecedented scale and brings about irreversible changes. One example is an oceanographic phenomenon known as a tombolo, i.e., a narrow belt connecting the mainland with an island lying near the shore formed as a result of sand and gravel being deposited by sea currents. The phenomenon contributes to an...
-
Influence of the low ambient temperature on the start-up process of hydraulic pumps
PublikacjaStarting hydraulic pumps in low ambient temperatures may cause: decreased hydraulic-mechanical efficiency, larger vibration of hydraulic installation, faster wear and more frequent damage to the elements of pumps, change of material properties of elements, increase of pressure drop. As a result of pressure drop in the suction pipe, large underpressure may be experienced, causing incomplete filling of pump working chambers with...