Filtry
wszystkich: 1077
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: IMPEDANCJA UZIEMIENIA
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 700 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Dane BadawczeThis dataset contains exemplary impedance spectra (measured at 700 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 800 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Dane BadawczeThis dataset contains exemplary impedance spectra (measured at 800 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Monitoring odbieraków prądu w warunkach eksploatacyjnych na linii kolejowej
PublikacjaPrawidłowa współpraca odbieraków prądu pojazdów z siecią jezdną trakcji elektrycznej jest warunkiem niezawodnego i bezpiecznego funkcjonowania transportu szynowego. Stany rozregulowania lub nawet uszkodzenia odbieraków prądu mogą występować pomiędzy okresowymi przeglądami taboru. W celu ich szybkiego wykrycia opracowano stanowisko monitoringu stanu technicznego odbieraków w warunkach eksploatacyjnych. Działanie układu opiera się...
-
Nowa metoda optymalizacji pracy ogniw paliwowych.
PublikacjaPrzedstawiono dynamiczną technikę impedancją jako doskonałe narzędzie służące do określenia optymalnych warunków pracy ogniw paliwowych. Możliwości tej techniki zostały przedstawione na przykładzie ustalenia optymalnej temperatury pracy. Otrzymane wyniki zostały skonfrontowane z charakterystykami prądowo napięciowymi ogniwa.
-
Odporność korozyjna staliwa wysokochromowego
PublikacjaBadano odporność korozyjną staliwa wysokochromowego w dwóch stanach: lanym i po obróbce cieplnej - hartowaniu i odpuszczaniu. Stwierdzono korzystny wpływ obróbki cieplnej na odporność korozyjną, ocenianą metodą badania polaryzacji i impedancji.
-
System do spektroskopii impedancyjnej z wykorzystaniem oscyloskopu cyfrowego.
PublikacjaW artykule przedstawiono alternatywną dla fabrycznych mierników impedancji metodę badań spektroskopowych materiałów biologicznych. System pomiarowy pozwala na osiągnięcie dużej dokładności pomiarów w szerokim zakresie częstotliwości, zwłaszcza w zakresie niskich częstotliwości.
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublikacjaAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
A comprehensive evaluation of mimosa extract as a corrosion inhibitor on AA6060 alloy in acid rain solution: part I. Electrochemical AC methods
PublikacjaThe inhibition effect of mimosa extract on the corrosion of AA6060 aluminum alloy in acid rain solution was investigated by electrochemical impedance spectroscopy and dynamic electrochemical impedance spectroscopy (DEIS). All the studied electrochemical parameters showed good corrosion inhibitive characteristics with respect to the aluminum alloy in the tested solution. Inhibitor efficiency increased with the concentration and...
-
Wyznaczanie właściwości uziemień metodami statycznymi, wysokoczęstotliwościowymi i udarowymi
PublikacjaW artykule przedstawiono różne metody pomiaru rezystancji statycznej i udarowej oraz impedancji uziemień. Przedstawiono wyniki badań porównawczych wykonanych przy użyciu metody statycznej, wysokoczęstotliwościowej oraz udarowej. Omówiono obszary zastosowań oraz ograniczenia omawianych metod.
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Mechanizm korozji stopu Al-Si nadtapianego laserowo w niskiej temperaturze.
PublikacjaBadano odporność na korozję elektrochemiczną stopu Al-Si metodami krzywych polaryzacji i impedancji. Ujawniono wyraźny wzrost odporności na korozję stopu nadtapianego laserowo po schłodzeniu do niskiej temperatury. Zaproponowano mechanizm korozji warstwy wierzchniej stopu.
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Badania eksperymentalne przy wykorzystaniu układu monitoringu dynamicznego oddziaływania odbieraka prądu na sieć trakcyjną
PublikacjaOpracowany układ monitoringu parametrów technicznych odbieraków prądu ma na celu wykrycie uszkodzonych lub źle wyregulowanych odbieraków w pojazdach znajdujących się w warunkach ruchowych na linii kolejowej. Ocenę stanu technicznego oparto na pomiarze i analizie uniesienia dynamicznego przewodów sieci jezdnej w momencie przejścia odbieraka pojazdu przez punkt pomiarowy. Omówiono zasadę działania stanowiska monitoringu, jego skalowanie...
-
Low temperature broad band dielectric spectroscopy of multiferroic Bi6Fe2Ti3O18 ceramics
PublikacjaIn the present research the tool of broadband dielectric spectroscopy was utilized to characterize dielectric behavior of Bi6Fe2Ti3O18 (BFTO) Aurivillius-type multiferroic ceramics. Dielectric response of BFTO ceramics was studied in the frequency domain (Δν=0.1Hz – 10MHz) within the temperature range ΔT=-100°C – 200°C. The Kramers-Kronig data validation test was employed to validate the impedance data measurements and it was found...
-
The effect of cobalt addition on the corrosion behavior of near equiatomic NiTi shape memory alloy in normal saline solution, impedance and microscopic studies
Dane BadawczeThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC. This dataset contains the results of electrochemical impedance spectroscopy (EIS) studies done on daily basis...
-
INFLUENCE OF BISMUTH CONTENT ON COMPLEX IMMITTANCE CHARACTERISTICS OF PRESSURELESS SINTERED BiNbO4 CERAMICS
PublikacjaGoal of the present research was to study immittance properties of BiNbO4 ceramics fabricated by the solid state reaction route followed by pressureless sintering. Four sets of samples were examined, namely the one fabricated from the stoichiometric mixture of oxides, viz. Bi2O3 and Nb2O5 as well as the ones with an excess of 3%, 5% and 10% by mole of Bi2O3. The immittance properties were studied by impedance spectroscopy. Measurements...
-
Investigation of corrosion behavior of 6060 and 6082 aluminum alloys under simulated acid rain conditions
PublikacjaInstantaneous impedance changes of 6060 and 6082 type aluminum alloys in pure water, and simulated acid rain poured into the pure water was investigated by dynamic electrochemical impedance spectroscopy (DEIS). In this way, the influence of aluminum content on the corrosion behavior of 6060 and 6082 type aluminum alloys immersed in simulated acid rain was determined. The corrosion rate of the alloy decreased with increasing Al...
-
PROBLEMS WITH CORROSION PROTECTION STEEL STACKS IN FGD SYSTEMS
PublikacjaThis paper presents problems associated with corrosion of steel stacks and changes in philosophy of corrosion protection when implemented into flue gas desulphurization systems. In-situ tests were taken by means of electrochemical impedance spectroscopy at a stack which discharges flue gas before wet lime/limestone desulphurization. A very rapid soaking of spherical infill vinylester coating with electrolyte has been observed....
-
Dynamic Nanoimpedance Characterization of the Atomic Force Microscope Tip-Surface Contact
PublikacjaNanoimpedance measurements, using the dynamic impedance spectroscopy technique, were carried out during loading and unloading force of a probe on three kinds of materials of different resistivity. These materials were: gold, boron-doped diamond, and AISI 304 stainless steel. Changes of impedance spectra versus applied force were registered and differences in the tip-to-sample contact character on each material were revealed. To...
-
Testing of the Superconducting Magnets Frequency Characteristics
PublikacjaPrzedstawiono zagadnienia związane z opracowaniem systemu do wyznaczania impedancji uzwojeń magnesów nadprzewodzących w funkcji częstotliwości. Omówiono strukturę sprzętową systemu, oprogramowanie oraz sposób wyznaczania parametrów badanego uzwojenia. Pokazano przykładowe wyniki uzyskane przy użyciu omawianego systemu w GSI w Darmstadt.
-
Dielectric Properties of BiNbO<sub>4</sub>-Based Ceramic-Polymer Composites with 0-3 Connectivity
PublikacjaIn the present study two-phase BiNbO4//PVDF composites with 0-3 connectivity were studied by impedance spectroscopy within the frequency range Δν=100Hz-1MHz at room temperature. Polyvinylidene fluoride (PVDF) acted as a matrix whereas bismuth niobate (BiNbO4) powder acted as a dispersed phase. The volume fraction of the ceramic phase was cV=2, 4, 6, 8, 10, 16 and 20vol%. Analysis of the impedance data registered for composites...
-
Ocena stanu technicznego odbieraków prądu na podstawie monitoringu na linii kolejowej
PublikacjaWdrożony układ monitoringu odbieraków prądu ma na celu wykrycie uszkodzonych lub źle wyregulowanych odbieraków w pojazdach, będących w ruchu na linii kolejowej. Ocenę stanu odbieraka oparto na rejestracji i analizie przebiegu uniesienia przewodów sieci jezdnej w czasie przejazdu pociągu przez punkt pomiarowy. Algorytm analizy wyników pozwala oszacować siłę statyczną każdego z podniesionych odbieraków, uwzględniając położenie odbieraków...
-
Badania eksperymentalne rezonansowego przetwornika piezoelektrycznego typu "unimorph"
PublikacjaW artykule opisano badania eksperymentalne piezoelektrycznego rezonansowego przetwornika zastosowanego do pomiaru właściwości mechanicznych tkanek miękkich. Po krótkim wstępie w kolejnych punktach przedstawiono opis stanowiska pomiarowego oraz metody pomiaru odkształceń prototypów, przesunięć częstotliwości rezonansowej, impedancji elektromechanicznej i parametrów schematów zastępczych. W dalszej...
-
Badania nowego czujnika wilgotności z filmem polimerowym
PublikacjaW pracy przedstawione zostały wyniki pomiarów widm impedancji czujników wilgotności z epoksydowymi filmami polimerowymi, zawierającymi czułe na wilgoć czwartorzędowe sole amoniowe. Filmy spreparowano z polietylenoiminy (PEI), usieciowanej przy pomocy eteru diglicydylowego 1,4-butanodiolu (BDDGE) z dodatkiem chlorku trójmetyloamoniowoglicydylowego (GTMAC).
-
Fast synthesis of coupled-resonator filters.
PublikacjaZaproponowana została nowa, szybko zbieżna technika syntezy macierzy sprzężneń filtrów wykorzystujących rezonatory sprzężone. Metoda jest sformułowana jako nieliniowy problem najmniejszych kwadratów, optarty o zera i bieguny zwarciowej impedancji wejsciowej i wyjściowej oraz wartości własnych macierzy sprzężeń i jej podmacierzy.
-
Non-linear electrical properties of myocardium in computer simulation
PublikacjaPomiar impedancji elektrycznej jest obiecującą metodą monitorowania stanu mięśnia sercowego, szczególnie podczas niedokrwienia. Typową metodą pomiaru jest rejestrowanie odpowiedzi-napięcia na pobudzenie prądowe. Odpowiedź jest często aproksymowana jako liniowa względem pobudzenia. Artykuł jest poświęcony oszacowaniu rzędu wielkości nieliniowych komponentów w odpowiedzi.
-
Charakterystyka wyładowań niezupełnych w izolacji polietylenowej przy nakładaniu udarów łączeniowych na napięcie przemienne
PublikacjaPrzedstawione w referacie badania wyładowań niezupełnych (wnz) dotyczą dynamiki zmian prądu wnz w układzie ostrze - płyta uziemiona w polietylenie sieciowanym poddawanego oddziaływaniu przepięć łączeniowych biegunowości dodatniej lub ujemnej nakładanych w momencie przejścia napięcia przemiennego przez zero oraz przy kącie fazowym 90o. Analizę zmian wybranych parametrów wnz w funkcji czasu wzrostu drzewka elektrycznego przeprowadzono...
-
Analizator do spektroskopii wysokoimpedancyjnej obiektów technicznych modelowanych obwodami elektrycznymi.
PublikacjaW pracy przedstawiono prototyp analizatora do spektroskopii wysokoimpedancyjnej przeznaczonego do diagnostyki powłok antykorozyjnych w warunkach laboratoryjnych oraz terenowych. Obiekt mierzony o module impedancji do 100Gohm jest dołączany do analizatora za pomocą sondy pomiarowej dwuzaciskowej dla obiektów uziemionych lub trzyzaciskowej w przypadku obiektów nieuziemionych. W sondzie są wydzielane dwa sygnały proporcjonalne do...
-
Distribution of Relaxation Times analysis results of impedance of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C) as a function of measuring temperature at 0.1% pO2
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode as a function of measuring temperature at 0.1% pO2. Electrode was sintered at 1000 °C and measured at different temperatures (800 °C, 750 °C, 700 °C).
-
ZWIĘKSZENIE EFEKTYWNOŚCI METODY ELEMENTÓW SKOŃCZONYCH Z WYKORZYSTANIEM WŁASNOŚCI GEOMETRII STRUKTUR
PublikacjaNiniejsza praca jest omówieniem fragmentów rozprawy doktorskiej autorki. Przedstawia ideę połączenia opisu analitycznego z metodą elementów skończonych poprzez uogólnioną macierz impedancji. Przedstawione zostały analizy dwóch struktur z wykorzystaniem metody hybrydowej, które wraz z porównaniem względem innych metod stanowią potwierdzenie zasadności prezentowanego podejścia.
-
Porównanie różnych metod pomiarów wysokości barier potencjału w strukturach MOS.
PublikacjaW referacie omówiono sposoby eliminacji problemów upływności bramki przy pomiarach charakterystyk C(V) kondnsatorów z ultra-cienkim tlenkiem bramki. Przedstawiono sposoby wykorzystania trójelementowego schematu zastępczego kondensatora MOS i przykład analizy pojemności, konduktancji tlenku i rezystancji szeregowej, zmierzonych przy pomocy miernika impedancji Agilent 4294A.
-
Nadtapianie laserowe silnie schłodzonych stopów Al-Si jako metoda podwyższania odporności korozyjnej.
PublikacjaPrzedstawiono wyniki badań krzywych polaryzacji i impedancji, uzyskane dla stopu Al-Si nadtapianego przy zastosowaniu okrągłej lub prostokątnej wiązki lasera i mocy 1500-6000 W. Wykazano, że warstwy uzyskane przy użyciu lasera o największej mocy mają duża odporność na korozję i dużą szczelność.
-
Hybrid Method Analysis of Unshielded Guiding Structures
PublikacjaA combination of mode matching, finite element methods and generalized impedance matrix is presented in a context of propagation problems for open guiding structures. The computational domain is divided into two regions: the first one is a circular cylinder containing whole guiding structure and the second one surrounds this artificial cylinder. The impedance matrix is calculated with the use of finite element method in the first...
-
Potential changes in an electric field and electrolytic corrosion.
PublikacjaSources have been described of corrosively hazardous electric fields and methods of determination of the corrosion hazard to metal structures caused by electrolytic corrosion. Results of potential and impedance investigations in the field of stray currents flowing out of a tram traction and in the presence of a defined electric field of low frequency have been presented. Uncertainties have been indicated relating to the generally...
-
Design optimization of novel compact circular polarization antenna
PublikacjaThe paper describes a structure and a design optimization procedure of a miniaturized circular polarization antenna with elliptical ground plane slots and feed line with stepped-impedance stubs. Constrained optimization of all antenna parameters is executed in order to explicitly reduce the antenna size while maintaining required impedance axial ratio bandwidth of 5 GHz to 7 GHz at the same time. The size of the optimized antenna...
-
Degradation of protective coatings in steel chimneys of flue gas desulfurisation system
PublikacjaThis paper presents problems associated with corrosion of steel stacks and changes in philosophy of corrosion protection when implemented into flue gas desulphurization systems. In-situ tests were taken by means of electrochemical impedance spectroscopy at the stack which discharges flue gas before wet lime/limestone desulphurization. A very quick electrolyte absorption by the spherical infill vinylester coating was found using...
-
Termowizja jako narzędzie weryfikacji stanu elementów ochronnych SMD podczas badań udarowych
PublikacjaPrzedstawiono wyniki badań przyrostów temperatury rejestrowanych za pomocą kamery termowizyjnej ochronnych elementów SMD podczas wykonywania badań odporności na udary napięciowe wykonywane wg normy EN61000-4-5 dla różnych poziomów sprzężeń impedancyjnych
-
Analiza procedur oceny uziemień odgromowych
PublikacjaW pracy dokonano prównania różnych metod wyznaczania parametrów uziemień odgromowych na tle obowiązujących przepisów. Porównano metody wyznaczania rezystancji statycznej i udarowej oraz impedancji uziemień w szerokim zakresie częstotliwości. Sformułowano wnioski dotyczące zasadności doboru odpowiednich metod pomiarowych do kontroli uziemień o różnej konstrukcji i różnym przeznaczeniu.
-
Experimental frequency-domain characterization of fundamental guided mode parameters in coupled coplanar waveguide
PublikacjaW pracy przedstawiono metodę wyznaczania współczynnika propagacji oraz impedancji charakterystycznej rodzajów podstawowych w strukturze sprzężonych linii koplanarnych. Metoda, oparta o wykorzystanie specjalnych struktur pobudzających oraz klasyczne pomiary w dziedzinie częstotliwości przy pomocy wektorowego analizatora sieci wykazała przydatność do wyznaczania zależnych od częstotliwości parametrów struktury.
-
Electrical mapping of AISI 304 stainless steel subjected to intergranular corrosion performed by means of AFM-LIS in the contact mode
PublikacjaThe paper presents results of the AFM-based approach to local impedance spectroscopy (LIS) measurements performed in a 20 20 lm grid within an austenite grain–grain boundary region for sensitized AISI 304 stainless steel (SS). Maps of electrical parameters obtained on the basis of localized impedance spectra were demonstrated, presenting their changes and correlation with the sample topography. Performed research revealed significant...
-
The inhibition effect of mad Honey on corrosion of 2007-type aluminium alloy in 3.5% NaCl solution
PublikacjaThe inhibition effect of mad honey on corrosion of 2007-type aluminium alloy in 3.5% NaCl solution was investigated by Tafel extrapolarisation (TP), electrochemical impedance spectroscopy (EIS) and dynamic electrochemical impedance spectroscopy (DEIS). All the studied parameters exhibited good anti-corrosive properties against corrosion of 2007-type aluminium alloy in the test solution; the corrosion rates decreased with the increase...
-
Electromagnetic plane wave scattering from a cylindrical object with an arbitrary cross section using a hybrid technique
PublikacjaA hybrid technique combining finite-element and mode-matching methods for the analysis of scattering problems in open and closed areas is presented. The main idea of the analysis is based on the utilization of the finite-element method to calculate the post impedance matrix and combine it with external excitation. The discrete analysis, which is the most time- and memory-consuming, is limited here only to the close proximity of...
-
Anna Golijanek-Jędrzejczyk dr inż.
Osoby