Filters
total: 641
filtered: 536
-
Catalog
Chosen catalog filters
Search results for: fault-tolerant grid
-
Power Electronic Transformer For Smart Grid Application
PublicationIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
Foundations of Grid Processing Architecture for the Comcute System
PublicationFundamental system algorithms and structures implemented in the Comcute system are described and analysed in detail. Layered architecture of the system model is highlighted. System tasks of the layers are elaborated, presented and described. Operational details of communication interfaces among layers are worked out and examined. The focus is put onto implemented system components with regard to their operability and efficiency....
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Frequently updated noise threat maps created with use of supercomputing grid
PublicationAn innovative supercomputing grid services devoted to noise threat evaluation were presented. The services described in this paper concern two issues, first is related to the noise mapping, while the second one focuses on assessment of the noise dose and its influence on the human hearing system. The discussed services were developed within the PL-Grid Plus Infrastructure which accumulates Polish academic supercomputer centers....
-
An Overview of Bidirectional EV Chargers: Empowering Traction Grid-Powered Chargers
PublicationIn recent years, the number of electric vehicles has been at least doubling year after year. As a result, today electric vehicles already account for approximately 10% of the global automotive market, which positively affects environment in urbanized areas. However, to take full advantage of the EV integration it is necessary to use renewable sources for their charging; optimally place charging stations/terminals; optimally manage...
-
Image Processing Techniques for Distributed Grid Applications
PublicationParallel approaches to 2D and 3D convolution processing of series of images have been presented. A distributed, practically oriented, 2D spatial convolution scheme has been elaborated and extended into the temporal domain. Complexity of the scheme has been determined and analysed with respect to coefficients in convolution kernels. Possibilities of parallelisation of the convolution operations have been analysed and the results...
-
Dobór elementów instalacji fotowoltaicznych - instalacje on-grid
PublicationObecnie instalacje fotowoltaiczne dołączone do sieci stanowią 72% wszystkich systemów fotowoltaicznych.System PV podłączony do sieci elektroenergetycznej wytwarza energię, która jest w sposób ciągły przekazywana do sieci, co (przeciwnie niż w instalacjach off-grid) pozwala na całkowite niedopasowanie liczby zamontowanych w instalacji modułów fotowoltaicznych do zapotrzebowania obiektu na energię elektryczną. W efekcie instalacja...
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublicationThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
SMART GRID TECHNOLOGIES IN ELECTRIC POWER SUPPLY SYSTEMS OF PUBLIC TRANSPORT
PublicationNowadays the issue of electric energy saving in public transport is becoming a key area of interest which is connected both with a growth in environmental awareness of the society and an increase in the prices of fuel and electricity. It can be achieved by improving the usage of regenerative breaking. In 2016 the Przedsiębiorstwo Komunikacji Trolejbusowej (PKT, Trolleybus Transport Company) in Gdynia began practical implementation...
-
Single-phase power electronics transformer with active functions for smart grid
PublicationThis paper presents the control of one cell of a modular single-phase power electronics transformer with active functions for meeting the smart grid concept. In this way, the converter could be used not only as a conventional transformer but also for grid such as reactive power, harmonic elimination and energy storage. The topology of the cell is composed by a bidirectional converter with three stages: a half bridge in the input...
-
Some Optimization Methods for Simulations in Volunteer and Grid Systems
PublicationIn this chapter, some optimization methods have been presented for improving performance of simulations in the volunteer and grid computing system called Comcute. Some issues related to the cloud computing can be solved by presented approaches as well as the Comcute platform can be used to simulate execution of expensive and energy consuming long-term tasks in the cloud environment. In particular, evolutionary algorithms as well...
-
New Two-center Ellipsoidal Basis Function Neural Network for Fault Diagnosis of Analog Electronic Circuits
PublicationIn the paper a new fault diagnosis-oriented neural network and a diagnostic method for localization of parametric faults in Analog Electronic Circuits (AECs) with tolerances is presented. The method belongs to the class of dictionary Simulation Before Test (SBT) methods. It utilizes dictionary fault signatures as a family of identification curves dispersed around nominal positions by component tolerances of the Circuit Under Test...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublicationThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Genetic Positioning of Fire Stations Utilizing Grid-computing Platform
PublicationA chapter presents a model for determining near-optimal locations of fire stations based on topography of a given area and location of forests, rivers, lakes and other elements of the site. The model is based on principals of genetic algorithms and utilizes the power of the grid to distribute and execute in parallel most performance-demanding computations involved in the algorithm.
-
Evaluation of Open Source SIEM for Situation Awareness Platform in the Smart Grid Environment
PublicationThe smart grid as a large-scale system of systems has an exceptionally large surface exposed to cyber-attacks, including highly evolved and sophisticated threats such as Advanced Persistent Threats (APT) or Botnets. When addressing this situation the usual cyber security technologies are prerequisite, but not sufficient. The smart grid requires developing and deploying an extensive ICT infrastructure that supports significantly...
-
Sieciowe systemy przetwarzania rozproszonego typu GRID – rozwiązania systemowe oraz przykłady aplikacyjne
PublicationZaprezentowano możliwości wykorzystania oraz integracji rozproszonych mocy obliczeniowych komputerów Internautów w globalnej sieci www. Pokazano paradygmaty internetowego przetwarzania rozproszonego typu grid computing oraz volunteer computing. Zwrócono uwagę na istotność tego typu przetwarzania w rozwiązywaniu zagadnień wymagających bardzo dużych mocy obliczeniowych. Pokazano reprezentatywne przykłady rozwiązań systemowych tego...
-
Fault detection in electronic circuits using test buses
PublicationA survey of test buses designed for diagnostics of digital and analog electronic circuits is presented: the IEEE 1149.1 bus for digital circuits, the IEEE 1149.4 bus for mixed-signal and the IEEE 1149.6 bus for AC coupled complex digital circuits. Each bus is presented with its structure, solution of key elements, particularly boundary registers and a set of test instructions. Diagnosis with the use of the described buses is...
-
Noninvasive method for rotor fault diagnosis in inverter fed induction motor drive
PublicationThis article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.
-
Modified sliding mode control for seamless integration of P.V. energy in A.C. grid
PublicationSolar energy is a potentially abundant and reliable source of renewable energy. While it can undoubtedly increase grid reliability and efficiency, the inverted voltage generated from PV. sources may introduce distortion into the AC. grid. The proposed control mechanism, modified sliding mode control (MSMC), can seamlessly integrate the inverter output generated by obtaining DC. voltage from the boost converter linked with the PV....
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublicationStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Smart grid technologies in electric traction: Mini inverter station
PublicationThe growing number of trams and trolleybuses equipped with recuperation systems contribute to the increase in the amount of energy recovered during braking. It raises questions about the possibility of its usage. One of such possibilities is the use of smart grid technology. The paper presents a case study of the use of braking energy in the trolleybus system for external loads by implementing mini inverter stations. Analysis is...
-
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
PublicationThe paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves...
-
Wybrane rozwiązania występujące w architekturach systemów rozproszonych klasy grid
PublicationOpisano wybrane rozwiązania występujące w architekturach systemów rozproszonych klasy grid. Odniesiono się do zapewnienia przezroczystości, a także do możliwości zarządzania i kontroli wykorzystania zasobów. Omówiono zasady optymalizacji zarządzania takimi systemami.
-
Automatic evaluation of information credibility in Semantic Web and Knowledge Grid
PublicationThis article presents a novel algorithm for automatic estimation of information credibility. It concerns information collected in Knowledge Grid and Semantic Web. Possibilities to evaluate the credibility of information in such structures are much greater than those available for WWW sites which use natural language. The rating system presented in this paper estimates credibility automatically on the basis of the following metrics:...
-
Oxygen vacancy-enriched V2O5·nH2O nanofibers ink for universal substrates-tolerant and multi means-integratable NH3 sensing
PublicationUniversal substrates-tolerant and multi means-integratable ammonia (NH3) sensing is highly desired in future Internet of Things in environmental monitoring, food security and early diagnosis of human diseases, however, is still less than satisfactory. Here, an oxygen vacancy-governed NH3 sensing has been developed with V2O5·nH2O nanofibers (NFs) ink, via combined thermal decomposition of ammonium metavanadate and dilution. As-obtained...
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublicationThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Efektywne zrównoleglanie obliczeń w systemie klasy grid na przykładzie hipotezy Collatza
PublicationZaprezentowano problem Collatza oraz sposób jego adaptacji, pozwalający na realizację obliczeń w systemie typu grid. Zidentyfikowano również pożądane cechy problemów obliczeniowych, dzięki którym mogą one zostać zrównoleglone w sposób efektywny w systemach typu grid i porównano je z cechami zadań realizowanych typowo przy użyciu klastrów obliczeniowych.
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Smart Grid in Practise - Implementation of the Billaterall Supply in Gdynia Trolleybus Network
PublicationSince 2001, trolleybus system in Gdynia has been involved in many activities related to the reduction of power consumption, both in terms of implementation and research and development. In 2011 was introduced the first supercapacitor storage energy system. In PKT started applications of Smart Grid technologies in supply network: the bilateral supply. The paper presents results of these this novel investitions.
-
Analog fault signature based on sigma-delta modulation and oscillation-test methodology.
PublicationW artykule dokonano przeglądu prac z zakresu testowania układów elektronicznych metodą oscylacyjną. Wskazując na niedostatki aktualnie stosowanej techniki testowania oscylacyjnego zaproponowano nową sygnaturę uszkodzeń dla układów analogowych. Proponowany parametr diagnostyczny jest wydobywany z odpowiedzi czasowej oscylatora testującego, w układzie złożonym z detektora szczytowego, modulatora sigma-delta oraz licznika rewersyjnego....
-
Novel Investigation of Higher Order Spectral Technologies for Fault Diagnosis of Motor-Based Rotating Machinery
PublicationIn the last decade, research centered around the fault diagnosis of rotating machinery using non-contact techniques has been significantly on the rise. For the first time worldwide, innovative techniques for the diagnosis of rotating machinery, based on electrical motors, including generic, nonlinear, higher-order cross-correlations of spectral moduli of the third and fourth order (CCSM3 and CCSM4, respectively), have been comprehensively...
-
Distributed Detection of Selected Features in Data Streams Using Grid-class Systems
PublicationThis chapter describes basic methodology of distributed digital signal processing. A choice of distributed methods of detection of selected features in data streams using grid-class systems is discussed. Problems related to distribution of data for processing are addressed. A mitigating method for data distribution and result merging is described.
-
A new approach to design of weather disruption-tolerant wireless mesh networks
PublicationWireless Mesh Networks, offering transmission rates of 1–10 Gb/s per a millimeter-wave link (utilizing the 71–86 GHz band) seem to be a promising alternative to fiber optic backbone metropolitan area networks because of significantly lower costs of deployment and maintenance. However, despite providing high transmission rates in good weather conditions, high-frequency wireless links are very susceptible to weather disruptions....
-
SMART GRID TECHNOLOGIES IN ELECTRIC POWER SUPPLY SYSTEMS OF PUBLIC TRANSPORT
PublicationNowadays the issue of electric energy saving in public transport is becoming a key area of interest which is connected both with a growth in environmental awareness of the society and an increase in the prices of fuel and electricity. It can be achieved by reducing of the transmission losses in supply system or by the improving of the usage of the regenerative breaking. The article presents an analysis of applying these two options...
-
SMART GRID TECHNOLOGIES IN ELECTRIC POWER SUPPLY SYSTEMS OF PUBLIC TRANSPORT
PublicationNowadays the issue of electric energy saving in public transport is becoming a key area of interest, which is connected both with a growth in environmental awareness of the society and an increase in the prices of fuel and electricity. It can be achieved by reducing the transmission losses in a supply system or by the improving the usage of the regenerative breaking. The article presents an analysis of applying these two options...
-
Creating Dynamic Maps of Noise Threat Using PL-Grid Infrastructure
PublicationThe paper presents functionality and operation results of a system for creating dynamic maps of acoustic noise employing the PL-Grid infrastructure extended with a distributed sensor network. The work presented provides a demonstration of the services being prepared within the PLGrid Plus project for measuring, modeling and rendering data related to noise level distribution in city agglomerations. Specific computational environments,...
-
Fault detection and diagnostics of complex dynamic systems using Gaussian Process Models - nuclear power plant case study
PublicationThe article examines the use of Gaussian Process Models to simulate the dynamic processes of a Pressurized Water nuclear Reactor for fault detection and diagnostics. The paper illustrates the potential of Gaussian Process Models as a tool for monitoring and predicting various fault conditions in Pressurized Water nuclear Reactor power plants, including reactor coolant flow and temperature variations, deviations from nominal working...
-
The Application Of A Noise Mapping Tool Deployed In Grid Infrastructure For Creating Noise Maps Of Urban Areas
PublicationThe concept and implementation of the system for creating dynamic noise maps in PL-Grid infrastructure are presented. The methodology of dynamic acoustical maps creating is introduced. The concept of noise mapping, based on noise source and propagation models, was developed and employed in the system. The details of incorporation of the system to the PL-Grid infrastructure are presented. The results of simulations performed by...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Dc Leakage Current in Isolated Grid-Connected dc Nanogrid - Origins and Elimination Methods
PublicationThe LV dc system is a relatively new trend in the distribution sector, which seems to grow widely in the near future due to its promising advantages. In this context, LV dc protection and grounding are challenging issues. Although the galvanically isolated connection mode of dc nanogrid to the ac grid has high reliability, the leakage current can still be injected into the ac grid through the interwinding capacitors and the insulation...
-
Techniki audytowania zabezpieczeń sieci bezprzewodowej z wykorzystaniem systemów klasy grid
PublicationZaprezentowano efektywne zasady weryfikacji zabezpieczeń sieci bezprzewodowych z wykorzystaniem oprogramowania Back/Track w dystrybucji systemu Linux. Omówiono algorytmy RC4, MIC i AES, które wspierają techniki zabezpieczeń WEP, WPA i WPA2 wchodzące w skład protokołu IEEW 802.11. Zamieszczano także opis wykorzystania systemu rozproszonego Comcute o architekturze typu grid do prowadzenia audytu bezprzewodowej sieci.
-
Big Data Paradigm Developed in Volunteer Grid System with Genetic Programming Scheduler
PublicationArtificial intelligence techniques are capable to handle a large amount of information collected over the web. In this paper, big data paradigm has been studied in volunteer and grid system called Comcute that is optimized by a genetic programming scheduler. This scheduler can optimize load balancing and resource cost. Genetic programming optimizer has been applied for finding the Pareto solu-tions. Finally, some results from numerical...
-
Meta-computations on the CLUSTERIX Grid
Publication -
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublicationThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...