displaying 1000 best results Help
Search results for: OPTICAL EMISSION SPECTROSCOPY
-
Amplitude-distance spectroscopy in semi-contact mode
Open Research DataSince it was invented by Binnig et al. in 1986, atomic force microscopy (AFM) plays a key role in science and technology at the nanoscale. AFM is a microscopic technique that visualizes the surface topography using the attractive and repulsive forces of interaction between several atoms (in theory) of a blade attached to the end of the probe lever and...
-
Corrosion rate measurements by non-linear electrochemical impedance spectroscopy
Publication -
Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy
Publication -
Raman spectroscopy study on concentrated acid treated carbon nanotubes
Publication -
Vibrational Spectroscopy in Analysis of Stimuli-Responsive Polymer–Water Systems
Publication -
Hydration of aprotic donor solvents studied by means of FTIR spectroscopy
PublicationThe paper attempts to explain the mutual influence of nonpolar and electron-donor groups on solute hydration,the problem of big importance for biological aqueous systems. Aprotic organic solvents have been used asmodel solutes, differing in electron-donating power. Hydration of acetonitrile, acetone, 2-butanone, andtriethylamine has been studied by HDO and (partially) H2O spectra. The quantitative version of...
-
Scanning tunneling microscopy and spectroscopy study of Nd2−xCexCuO4−y
Publication -
Electrooxidation of dissolved dsDNA backed by in situ UV-Vis spectroscopy
PublicationPrzeprowadzono badania elektrochemicznego utleniania dsDNA stosując metody cyklowoltametryczne na elektrodzie weglowej, platynowej, platynowej w formie siatki oraz z siatki platynowej osadzonej na węglu. Otrzymane wyniki analizy spektroelektrochemicznej wykazały, że wraz ze wzrostem potencjału i piku prądowego absorpcja roztworu dsDNA wzrasta w sposób zależny od typu elektrody. Jednak położenie maksimum absorpcji nie zmieniało...
-
Quality assessment of varistor ZnO structures by resonant ultrasound spectroscopy
PublicationWarystory sa wytwarzane z tlenku cynku ZnO jako cylindrycznie uformowane struktury, a ich jakość zależy od zmieniających się uwarunkowań technologicznych na etapach formowania ich kształtu oraz spiekania. W związku z tym są one testowane w końcowej fazie produkcji, a elementy wadliwe się odrzuca. Proponujemy testowanie jakości struktur ZnO we wcześniejszej fazie ich wytwarzania w celu wyeliminowania elementów wadliwych z dalszej,...
-
Spectroscopy and Dynamics of Cryptolepine in the Nanocavity of Cucurbit[7]uril and DNA
Publication -
Vibrational spectroscopy of semiheavy water (HDO) as a probe of solute hydration
PublicationSpektroskopia oscylacyjna jest idealną metodą w badaniach zjawisk hydratacyjnych. Przy zastosowaniu techniki rozcieńczenia izotopowego, gdy mała ilość D2O zostaje wprowadzona do H2O lub vice versa i powstaje woda półciężka (HDO), ominąć można wiele problemów technicznych i interpretacyjnych związanych z pomiarem widm w podczerwieni wody ciekłej. Zwłaszcza izotopowe rozprzężenie drgań rozciągających ułatwia interpretację widm. Systematycznie...
-
A study of the electronic states of pyrimidine by electron energy loss spectroscopy
PublicationThe electron energy loss spectra were measured in pyrimidine at the constant electron residual energy varied from 15 meV to 10 eV and in the scattering angle range 0–180°. The spectra were analysed applying an iteration fitting procedure to resolve the energy loss bands corresponding to excitation of the electronic states of pyrimidine. The vertical excitation energies of the singlet states of pyrimidine and of a number of the...
-
Conformational studies of neurohypophyseal hormones analogues with glycoconjugates by NMR spectroscopy
Publication -
Electron energy-loss spectroscopy of excited states of the pyridine molecules
PublicationElectron energy-loss spectra of the pyridine, C5H5N, molecules in the gas phase have been measured to investigate electronic excitation in the energy range 3.5–10 eV. The applied wide range of residual electron energy and the scattering angle range from 10 ◦ to 180 ◦ enabled to differentiate between optically-allowed and -forbidden transitions. These measurements have allowed vertical excitation energies of the triplet excited...
-
Synchrotron radiation photoemission spectroscopy of the oxygen modified CrCl3 surface
PublicationWe investigate the experimentally challenging CrCl3 surface by photon energy dependent photoemission (PE). The core and valence electrons after cleavage of a single crystal, either in a ultrahigh vacuum (UHV) or in air, are studied by keeping the samples at 150 1C, aiming at confirming the atomic composition with respect to the expected bulk atomic structure. A common spectroscopic denominator revealed by data is the presence of...
-
Evaluating and predicting the performance of organic coatings using impedance spectroscopy
PublicationPrzedstawiono wyniki badań cyklicznych, sinusoidalnych zmian temperatury na powłokowe systemy ochronne o skrajnie różnych właściwościach antykorozyjnych. Porównano zachowanie nowej powłoki poliestrowej typu "coil-coating" na ocynkowanej stali uprzednio eksponowanej w warunkach atmosferycznych alkidowej powłoki malarskiej na podłożu stalowym. Badania przeprowadzono przy zastosowaniu techniki spektroskopii impedancyjnej. Stwierdzono...
-
Dynamic electrochemical impedance spectroscopy of the first order electrode reaction
PublicationCiągłe transformaty STFT sinusoidalnego sygnału pobudzenia i odpowiedzi prądowej zostały wyznaczone dla reakcji elektrodowej pierwszego rzędu. Wyznaczono impedancję elektrody w łącznej dziedzinie czasu i częstotliwości. Wykonano pomiary dla reakcji redukcji Cd(II) na rtęciowej elektrodzie kroplowej w funkcji potencjału. Przedstawiono możliwość wyznaczenia chwilowych widm impedancyjnych. Opisano zależność rezystancji przeniesienia...
-
Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy.
PublicationPrzeprowadzono badania stali stopowej 304L metodą dynamicznej elektrochemicznej spektroskopii impedancyjnej w warunkach liniowo zmieniającego się potencjału. Określono ogólny schemat układu elektrycznego dla elektrody ulegającej korozji. Przeprowadzone badania pozwalają na jednoczesne badanie zachowania się stali stopowej w stanie pasywnym, podczas stanu przejściowego (metastabilne tworzenie się i repasywacja wżerów) oraz w stanie...
-
Confined lead nanogranules investigated by X-ray absorption spectroscopy
Publication.
-
Raman Spectroscopy for Investigation of Sol-Gel Materials and Ceramic Materials.
PublicationPrzedstawiono rezultaty prac nad zastosowanie spektroskopii ramanowskiej do badania polimerów hybrydowych wytwarzanych metodą zol-żel oraz ceramik ferroelektrycznych. Wykonano pomiary dla próbek objętościowych i struktur cienkowarstwowych. Zademonstrowano możliwośc monitorowania procesu syntezy w czasie rzeczywistym.
-
Optical glyphs based localization and identification system
PublicationThe paper presents a description of functioning of a platform supporting the detection of obstructive diseases in the respiratory system education process. A 16-parameter model of the respiratory system simulated in the MATLAB/Simulink environment was set in the role of the tested patient. It has been linked to the control layer, developed in the LabVIEW environment, using the SIT library (Simulation Interface Toolkit). This layer...
-
Polarization state analysis in optical coherence tomography
PublicationW artykule zaprezentowano metody analizy stanu polaryzacji światła w systemach optycznej tomografii kohererentnej. Przedstawiono różne konfiguracje systemu PS-OCT wraz z ich parametrami oraz właściwościami. Omówiono zasadę pomiaru stanu polaryzacji ściatła przy użyciu systemu PS-OCT oraz przeprowadzono dyskusję nad przydatnością metody do badania struktury materiałów silnie rozpraszających promieniowanie.
-
Fluorescence Measurements for chemical optical sensor of cobalt
PublicationW pracy zaproponowano i opisano optoelektroniczny fluorescencyjny sensor do pomiaru stężenia kobaltu w wodzie.
-
Polarization sensitive optical coherence tomography system
PublicationW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Synthesized light source for optical coherence tomography
PublicationW artykule omówiono wpływ parametrów źródła promieniowania optycznego na właściwości systemu OCT. Szczególną uwagę zwrócono na źródła syntezowane. Omówiono charakterystykę źródła zbudowanego z dwóch różnych diod SLD. Przedstawiono wyniki pomiarów, które wskazują na możliwości znacznego polepszenia czułości i rozdzielczości systemu OCT wykorzystującego takie źródło.
-
Optical Investigation of Hematocrit Level in Human Blood
PublicationW artykule przedstawiono możliwości wykorzystania metod optoelektronicznych, takich jak: spektroskopia Ramana i interferometria niskokoherencyjna do pomiaru poziomu hematokrytu ludzkiej krwi.
-
Porphyrazines with peripheral isophthaloxyalkylsulfanyl substituents and their optical properties
Publication -
Dispersion of thermo-optic coefficient of optical polymers
Publication -
Electrical and optical characterization of ITO thin films
PublicationW pracy przestawiono wyniki badań tlenku cyny domieszkowanego indem (ITO) pod kątem zastosowania jako przezroczyste elektrody. opisano metody pomiarów wybranych właściwości elektrycznych i optycznych. cienką warstwę ito, naniesioną na szklane podłoże, wykonano metodą rozpylania magnetronowego.
-
Development of optical fiber technology in Poland – 2018
Publication -
Development of optical fiber technology in Poland 2020
Publication -
Development of optical fiber technology in Poland: 2017
Publication -
<title>Applications of capillary optical fibers</title>
Publication -
Apparatus to search for optical flashes of extragalactic origin
Publication -
Development of optical fiber technology in Poland: 2014
Publication -
<title>Measurements of nonlinear optical fibers</title>
Publication -
Broadband Buses Based On Multicore Optical Fibres
Publication -
Multiclad Monomode Optical Fibres By MZD Technology
Publication -
Development of optical fiber technology in Poland 2015
Publication -
Optical Fibre, Local Measurement Systems For Ships
Publication -
Single-Mode Quadruple-Core Optical Fibres
Publication -
Geometry design in rerfractive capillary optical fibers
Publication -
Application of optical fibres in oxidation-reduction titrations
Publication -
Optical switching technologies: problems and proposed solution
Publication -
Carbon-Coated Tellurium for Optical Data Storage
Publication -
Laser Induced Piezo-Optical Effects in Chalcogenides
Publication -
Optical and electrical properties of Pr0.8Sr0.2MnO3 thin films.
PublicationPrzedstawiono preparatykę, strukturę oraz optyczne i elektryczne właściwości cienkowarstwowego Pr0.8Sr0.2MnO3. Gęste filmy o grubości 50-70nm zostały naniesione na monokrystaliczne podłoże szafirowe metodą odwirowania prekursora polimerowego. Wyniki optycznych pomiarów zostały skorelowane z temperaturą syntezy filmów. Pokazano, że optyczne spektra zmieniają kształt wraz ze zmianą struktury filmu z amorficznej do krystalicznej....
-
Intelligent algorithms for optical track audio restoration
PublicationW referacie przedstawiono dwa algorytmy dedykowane redukcji pasożytniczych zniekształceń dźwięku spotykanych w optycznych ścieżkach dźwiękowych. Pierwszy algorytm umożliwia redukcję szerokopasmowego szumu w nagraniach fonicznych. Wykorzystano w nim psycho-akustyczny model słuchu oparty o miarę nieprzewidywalność sygnału (ang. Unpredictability Measure). Ocena jakości redukcji szumu została wykonana z wykorzystaniem metod inteligentnych....
-
Optical metrology for high fidelity LCD-TV
PublicationW pracy przedstawiono aktualny stan metrologii optycznej wyświetlaczy ciekłokrystalicznych (LCD) i omówiono niedoskonałości obecnych technik pomiarowych występujące w charakteryzacji wyświetlaczy o wysokiej wierności odwzorowania. Zaprezentowano urządzenia, procedury pomiarowe i metody obróbki danych umożliwiajace obiektywną ocenę właściwości ciekłokrystalicznych odbiorników telewizyjnych.Metody te umożliwiają identyfikację artefaktów...
-
Acoustic emission signals in concrete beams under 3-point bending (polyolefin and steel fibre concrete)
Open Research DataThe DataSet contains the results of the mechanical behaviour of concrete beams with dimensions 40 x 40 x 160 cm3 under the 3-point bending. All specimens were manufactured based on the same concrete mixture composed of cement CEM I 42.5R (380 kg/m3), water (165 kg/m3), aggregate 0/2 mm (648 kg/m3), aggregate 2/8 mm (426 kg/m3), aggregate 8/16 mm (754...