Search results for: Active control
-
Code development of a DSP-FPGA based control platform for power electronics applications
PublicationThis paper focuses on the implementation of power electronics algorithms in control platforms based on DSP-FPGA. Today’s power electronics technology demands high power computation with high speed interfacing at the same time. The most popular configuration is a DSP for the former and a FPGA for the latter. The main goal of this work was to develop a generic control system for power electronics application, but it is explained...
-
Comparative analysis of seismic response reduction in multi-storey buildings equipped with base isolation and passive/active friction-tuned mass dampers
PublicationThis study presents an innovative approach to mitigating seismic responses in multi-storey buildings equipped with a base-isolation (BI) system and passive friction-tuned mass dampers (PFTMDs). The key innovation lies in the combined use of a BI system and a PFTMD system, as well as the activation of this mechanical system by controllers. Additionally, the research design optimizes the parameters of these devices specifically for...
-
Control structures of Doubly-Fed Induction Generator connected to Current Source Converter
PublicationThe control of Doubly-Fed Induction Generator can be achieved through various techniques. At present, many works published in the literature show the application of Voltage Source Converter in conjunction with Doubly-Fed Induction Generator. Recently published articles rarely involve the operational characteristics and technical aspects of the Doubly-Fed Induction Generator...
-
Photoluminescence of partially reduced Eu2+/Eu3+ active centers in a NaF–Al2O3–P2O5 glassy matrix with tunable smooth spectra
PublicationIn this work, a series of photoluminescent materials have been synthesized based on optically transparent and chemically stable glasses of the nominal composition Na3Al2(PO4)2F3 (NaF–Al2O3–P2O5 system) doped with 1 wt% of europium. It has been shown that the synthesis conditions (mainly the temperature and duration of the melting stage under reducing conditions) strongly affected the photoluminescence spectra of the material. This...
-
Deep slot effect in the squirrel-cage induction motors with scalar (V/F) control
PublicationQualitative characteristics of the electrical drive considerably depend on identification accuracy of math model parameters. In particular, it is depend on detection accuracy of stator active resistance r1 that is used in calculation of flux linkages, rotary speed in sensorless control systems. Paper provides analysis of influence of stator deep slot effect to stator active resistance value
-
Control strategy for the multilevel cascaded H-bridge converter
PublicationThe paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Flexible Knowledge–Vision–Integration Platform for Personal Protective Equipment Detection and Classification Using Hierarchical Convolutional Neural Networks and Active Leaning
PublicationThis work is part of an effort to develop of a Knowledge-Vision Integration Platform for Hazard Control (KVIP-HC) in industrial workplaces, adaptable to a wide range of industrial environments. The paper focuses on hazards resulted from the non-use of personal protective equipment (PPE). The objective is to test the capability of the platform to adapt to different industrial environments by simulating the process of randomly selecting...
-
Control of the wind turbine generator
PublicationWind power system consists of two main parts: wind turbine and electrical generator. Wind turbine converts the energy of the flowing air into mechanical energy, next generator converts this energy into electrical energy that is sent to the power system. These two processes should be realized with maximum efficiency and the following requirements for the control system can be formulated: opti-mal wind power conversion, compensation...
-
Deformation mitigation and twisting moment control in space frames
PublicationOver the last five decades, space frames have centered on the modernization of touristic zones in view of architectural attractions. Although attempts to control joint movement and minimize axial force and bending moment in such structures were made sufficiently, twisting moments in space frames have been underestimated so far. In space frames, external load or restoring the misshapen shape may cause twisting in members. We herein...
-
Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter
PublicationNowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...
-
Frequency and time domain characteristics of digital control of electric vehicle in-wheel drives
PublicationIn-wheel electric drives are promising as actuators in active safety systems of electric and hybrid vehicles. This new function requires dedicated control algorithms, making it essential to deliver models that reflect better the wheel-torque control dynamics of electric drives. The timing of digital control events, whose importance is stressed in current research, still lacks an analytical description allowing for modeling its...
-
A modified method of vibration surveillance by using the optimal control at energy performance index
PublicationA method of vibration surveillance by using the optimal control at energy performance index has been creatively modified. The suggested original modification depends on consideration of direct relationship between the measured acceleration signal and the optimal control command. The paper presents the results of experiments and Hardware- in-the-loop simulations of a new active vibration reduction algorithm based on the energy...
-
СИЛОВОЙ ПРЕОБРАЗОВАТЕЛЬ С АКТИВНЫМ ПОДАВЛЕНИЕМ ВЫСШИХ ГАРМОНИК ДЛЯ СИСТЕМ ЭЛЕКТРОСНАБЖЕНИЯ ЛЕТАТЕЛЬНЫХ АППАРАТОВ (Power converter with active suppression of higher harmonics for aircraft power supply systems)
PublicationПредставлены два алгоритма активной фильтрации для силового преобразователя с активным подавлением высших гармоник. Первый алгоритм основан на дискретном преобразовании Фурье: посредством синтезированной системы управления инвертированные измеренные высшие гармоники напряжения поступают на вход инвертора. Второй метод управления основан на алгоритме с использованием принципов самообучения, что значительно снижает потребность в...
-
Power control system structure of doubly‐fed induction generator connected to current source converter
PublicationThe power control system structures for a doubly-fed generator (DFIG) are proposed. The classical field oriented control and the feedback control with the multi-scalar variables were considered. The generator is working in the AC grid connection mode. The rotor side of the generator is connected to the current source converter (CSC); the stator is directly related to the AC grid. The static feedback linearization using the multi-scalar...
-
Buckling and shape control of prestressable trusses using optimum number of actuators
PublicationThis paper describes a method to control the nodal displacement of prestressable truss structures within the desired domains. At the same time, the stress in all members is unleashed to take any value between the allowable tensile stress and critical buckling stress. The shape and stresses are controlled by actuating the most active members. The technique considers the members’ initial crookedness, residual stresses, and slenderness...
-
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
PublicationIn the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including...
-
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
PublicationIn the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including...
-
Active dynamic thermography in cardiosurgery
Publication.
-
Active dynamic thermography in mammography.
PublicationW artykule przedstawiono zaproponowany numeryczny model termiczny piersi z nowotworem umiejscowionym na różnych głębokościach. Przedstawione są wyniki symulacji modelu dla różnych warunków zewnętrznego pobudzenia termicznego powierzchni piersi. Pokazano również wyniki przykładowego badania termograficznego piersi z nowotworem.
-
Active shape models in practice
PublicationAutorzy wykonali uniwersalny system lokalizacji obiektów zawierający implementację aktywnych modeli kształtu, a przeprowadzone z użyciem tego systemu eksperymenty wykazały powżne wady badanej metody. W pracy przedstawiono zaobserwowane w praktyce problemy związane ze stosowaniem metody aktywnych modeli kształtu (ASM).
-
Active Power Quality Controllers
PublicationDynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...
-
Design of synchronous generator two inputs regulator based on hinf control theory.
PublicationThe power system is highly nonlinear system, its dynamics depends on system network configuration, system loading… etc. To overcome the above mentioned difficulties and fulfill the performance requirements the different control methods are considered and tested for design of synchronous generator control system. Application of the H optimization method to synchronous generator regulator based on measurement of generator voltage...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublicationThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Application and modelling of Shape-Memory Alloys for structural vibration control: State-of-the-art review
PublicationOne of the most essential components of structural design for civil engineers is to build a system that is resistant to environmental conditions such as harsh chemical environments, and catastrophic disasters like earthquakes and hurricanes. Under these circumstances and disturbances, conventional building materials such as steel and concrete may demonstrate inadequate performance in the form of corrosion, deterioration, oxidizing,...
-
Active structural waveguide for sensing application
Publication -
Active carbons from waste biochars
Publication -
Conducting polymers electrodeposited on active metals
PublicationPraca poświęcona studiom literaturowym doniesień dotyczących polimerów przewodzących, osadzanych na metalach aktywnych. Zastosowanie polimerów przewodzących jako warstw antykorozyjnych oraz elektrokrystalizacja metali na polimerach przewodzących zostały zebrane i przedstawione w tej pracy.
-
Active Dynamic Thermography in Medical Diagnostics
PublicationThis is an overview of active thermal imaging methods in medical diagnostics using external thermal stimulation. In this chapter, several clinical cases diagnosed using the active dynamic thermography method, ADT, are presented. Features of this technology are discussed and main advantages underlined. Applications in skin burn diagnostics and quantitative evaluation leading to modern classification of burned patients for further...
-
Chapter 8 – Active Sampling of Air
PublicationThis chapter reviews the literature information on analytical techniques and laboratory equipment used for active sampling of air (atmospheric and indoor) in regular monitoring research. It describes popular analytical devices applied for sample collection using various types of polymeric bags, e.g. Tedlar bags, Teflon or Nafion bags, and/or stainless steel vacuum containers. It reviews literature data about the application of...
-
Occurrence of Surface Active Agents in the Environment
PublicationDue to the specific structure of surfactants molecules they are applied in different areas of human activity (industry, household). After using and discharging from wastewater treatment plants as effluent stream, surface active agents (SAAs) are emitted to various elements of the environment (atmosphere, waters, and solid phases), where they can undergo numerous physic-chemical processes (e.g., sorption, degradation) and freely...
-
Active IR-Thermal Imaging in Medicine
PublicationIn this paper we summarize results of several research projects devoted to development of new diagnostic methods and procedures based on quantitative infrared thermography in medical applications. First, basics of active dynamic thermography are presented. Described are both, instrumentation and software comprising measurement procedures including collection of series of IR-images after external excitation, data treatment with...
-
Active Learning Based on Crowdsourced Data
PublicationThe paper proposes a crowdsourcing-based approach for annotated data acquisition and means to support Active Learning training approach. In the proposed solution, aimed at data engineers, the knowledge of the crowd serves as an oracle that is able to judge whether the given sample is informative or not. The proposed solution reduces the amount of work needed to annotate large sets of data. Furthermore, it allows a perpetual increase...
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublicationFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
Sensorless Rotor Position Estimation of Doubly-Fed Induction Generator Based on Backstepping Technique
PublicationThis paper proposes a speed observer algorithm for the sensorless control of a doubly-fed induction generator based on classical adaptive backstepping technique. The sensorless control is shown using classic stator field oriented control which is used to active and reactive power control. Performance of the proposed algorithm of a speed observer is validated by simulation and experimental results obtained using a small-rating generator...
-
Impact of R/X ratio of distribution network on selection and control of energy storage units
PublicationThe interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...
-
Application of TMS320c67xx signal processors for SONIC-self-optimizing narrowband interference canceler
PublicationThe paper presents a laboratory system for testing active control algorithms of acoustics noise in ducts. An applied algorithm - self-optimizing narrowband interference canceller (SONIC), allows one to remove narrowband disturbances of constant or slowly time-varying frequencies. Example experimental results of using the laboratory system for supression of sinusoidal disturbance are described. An electronic part of the system was...
-
Balancing energy consumption in limited power grid with active front-end and three phase dual active bridge system
PublicationPaper deals with simulation analysis of bidirectional power converters system for charging station of electric vehicle in condition of limited power source in city infrastructure. In case of incapability to provide additional power supply through the grid by virtue of historical, architectural and economic reasons it is possible to solve this issue by implementation of mobile battery-powered supply source. The proposed bidirectional...
-
Chemosensitive Thin Films Active to Ammonia Vapours
Publication -
Active materials to enhance the efficiency of PV systems
Publication -
Study of Photovoltaic Devices with Hybrid Active Layer
PublicationThe aim of this work is to present the influences of composition of the material andmanufacturing technology conditions of the organic photovoltaics devices (OPv) with the organicand hybrid bulk heterojunction on the active layers properties and cells performance. The layers wereproduced by using small molecular compounds: the metal-phthalocyanine (MePc) and perylenederivatives (PTCDA) and the titanium dioxide (TiO2) nanoparticles....
-
Photo-acoustic response of active biological systems
PublicationZbadano dwie próbki organiczne gatunku Trunculariopsis trunculus,jedną wilgotną, drugą - suchą. W obu przypadkach zaobserwowanointensywne szerokie pasma absorpcyjne w zakresie widzialnym (żółtymi poniżej 330 nm). Widma foto-akustyczne zawierają wszystkie pasma uznane za związane z aktywnością biologiczną.
-
A simple modular active power electronic transformer
Publication -
Baltic cyanobacteria – a source of biologically active compounds
Publication -
A boost topology active power factor corrector.
PublicationPrzedstawiono układ analogowego aktywnego korektora zbudowanego na układzie scalonym kontrolera PWM oraz tranzystorem MOS jako okresowo przełączonym kluczem. Układ korektora zapewnia pobór prądu z sieci energetycznej w postaci przebiegu prawie sinusoidalnego o małych zniekształceniach i w fazie z sinusoidalnym napięciem sieci.
-
Synthesis of parametric images in the medical active thermography
PublicationArtykuł przedstawia zastosowanie nowej metody syntezy obrazów w termografii dla potrzeb opisu ilościowego właściwości termicznych tkanek. opis taki umożliwia różnicowanie przypadków medycznych. Metodę zastosowania dla licznych pomiarów fantomowych oraz in vitro. Przedstawiono i omówiono rezultaty prac.
-
Modeling of active fiber Bragg grating sensors
PublicationW artykule omówiono działanie przetwornika hydrofonu wykorzystującego profilowaną membranę sprzężoną z aktywną światłowodową siatką Bragga. W wyniku modelowania, wykonanego Metodą Elementów Skończonych, stwierdzono występowanie gradientów naprężeń wzdłuż siatki. Opracowano program do modelowania pasywnych i aktywnych światłowodowych siatek Bragga wykorzystujący metodę modów sprzężonych. Przedstawiono charakterystyki widmowe pasywnych...
-
Implementation of Active Dynamic Thermography in medical diagnostics
PublicationW pracy przedstawiono wyniki badań wdrożeniowych Aktywnej Termografii Dynamicznej w diagnostyce wybranych chorób.
-
Optimization of active circuits for substrate noise suppression
PublicationZakłócenia generowane przez szybkie podukłady cyfrowe w mieszanych systemach analogowo-cyfrowych realizowanych na wspólnym podłożu stają się dużym problemem. W pracy zaproponowano metodę optymalizacji aktywnych układów tłumienia zakłóceń. Zilustrowano skuteczność działania metody na wybranym układzie i uzyskano ponad 9 dB poprawę tłumienia zakłóceń na częstotliwości 1GHz w porównaniu do znanych rozwiązań.