Search results for: CONTACT
-
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublicationWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
Influence of concentration on contact angle of water-Cu nanofluid on glass substrate
PublicationIn the paper the results of an experimental investigation of influence of nanoparticle concentration on contact angle of water-Cu nanofluid on glass substrate have been presented. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. In the present study copper was applied as nanoparticle while distilled, deionized water was used as a base fluid. The mean diameter of nanoparticle is estimated to be 50...
-
Analysis of Ceramic Elements with Ring-Crack Defects in Lubricated Rolling Contact
PublicationThe properties of ceramics, specifically low density, high hardness, high temperature capability and low coefficient of thermal expansion are of most interest to rolling element manufacturers. Surface ring cracks on lubricating rolling contact fatigue failure has been studied using numerical fracture analysis. Such cracks are very often found on ceramic bearing balls and decrease fatigue life rapidly. The numerical calculations...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
FURTHER REMARKS ON THE SURFACE VIS IMPRESSA CAUSED BY A FLUID-SOLID CONTACT
PublicationIt is well-known that, nano-mechanics should take into account not only physical phenomena occuring within the bulk but, first of all, the physical phenomena appropriate for a surface of two materials contact. The huge volume density of internal surfaces as well countours lines located within the nanomaterial results in our interest in, apart from classical form of mass, momentum and entropy transport, those modes of transportation...
-
The influence of selected parameters of idd on vibrations of contact in ac hybrid breaker
PublicationWzrost mocy systemów zasilania na statkach wymaga poszukiwania nowych rozwiązań wyłączników dc oraz ac. Od kilku lat trwają prace nad modelowaniem ultra szybkiego hybrydowego wyłącznika prądu. Czas wyłączenia prądu wyłącznika zależy od wielu parametrów. W pracy przedstawiono wyniki badań eksperymentalnych i symulacyjnych wyłącznika ze szczególnym uwzględnieniem rezystancji zestyku.
-
A chemo-mechano-thermodynamical contact theory for adhesion, friction, and (de)bonding reactions
PublicationThis work presents a self-contained continuum formulation for coupled chemical, mechanical, and thermal contact interactions. The formulation is very general and, hence, admits arbitrary geometry, deformation, and material behavior. All model equations are derived rigorously from the balance laws of mass, momentum, energy, and entropy in the framework of irreversible thermodynamics, thus exposing all the coupling present in the...
-
Wavelet transform-based approach to defect identification in railway carbon contact strips.
PublicationPantographs of electric rail vehicles are fitted with carbon contact strips, which slide along the contact wire of catenary to provide constant electrical contact. Contact strips are exposed to wear and damages. Using damaged contact strips significantly increases the risk of catenary rupture. Therefore, their technical condition has to be inspected frequently. In previous work a 3D laser scanning system was proposed for recording...
-
On topology optimization of large deformation contact-aided shape morphing compliant mechanisms
PublicationA topology optimization approach for designing large deformation contact-aided shape morphing compliant mechanisms is presented. Such mechanisms can be used in varying operating conditions. Design domains are described by regular hexagonal elements. Negative circular masks are employed to perform dual task, i.e., to decide material states of each element and also, to generate rigid contact surfaces. Each mask is characterized by...
-
An isogeometric finite element formulation for frictionless contact of Cosserat rods with unconstrained directors
PublicationThis paper presents an isogeometric finite element formulation for nonlinear beams with impenetrability constraints, based on the kinematics of Cosserat rods with unconstrained directors. The beam cross-sectional deformation is represented by director vectors of an arbitrary order. For the frictionless lateral beam-to-beam contact, a surface-to-surface contact algorithm combined with an active set strategy and a penalty method...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublicationThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
PublicationIn this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
Correlated electrons and transport in a quantum point contact and in a double-quantum-dot system
Publication -
Poly(3-octylthiophene) as solid contact for ion-selective electrodes: contradictions and possibilities
Publication -
Some fundamental aspects of self-levitating sliding contact bearings and their practical implementations
PublicationIn this study, fundamental aspects and mechanisms of acoustic levitation together with governing equations are presented first. Then, the acoustic levitation phenomenon is considered as a new way to design air suspension systems capable of self-levitation. A particular emphasis is laid on journal bearings and their specific geometrical configuration. A practical feasibility of using acoustic levitation to separate contacting surfaces...
-
APPLICATION OF INFRARED THERMOGRAPHY TO NON-CONTACT TESTING OF AD/DC POWER SUPPLY
PublicationTesting of AC/DC power supplies using the thermography was carried out in order to assess their assembly and operation correctness before launching them on the market. The investigation was carried out for 17 AC/DC power supplies which passed the standard tests (measurements of their basic parameters and characteristics). The investigation consisted of two steps. In the first step the dispersion of temperature on power supply boards...
-
Studies on membrane scaling during water desalination by direct contact membrane distillation
Publication -
Evaluation of fouling potential of nanofiltration membranes based on the dynamic contact angle measurements
Publication -
Influence of morphology of PVDF capillary membranes on the performance of direct contact membrane distillation
Publication -
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Algorithm for Automatic Wear Estimation of Railway Contact Strips Based on 3D Scanning Results
PublicationElectric rail vehicles use current collection system which consists of overhead contact line and a current collector (pantograph) mounted on the roof of a vehicle. A pantograph is equipped with contact strips, which slide along the contact wire, ensuring steady electric contact. Contact strips are made of carbon layer, fixed to an aluminum carrier. The carbon layer wears down due to friction. Using overly worn contact strips increases...
-
3D Machine Vision System for Inspection of Contact Strips in Railway Vehicle Current Collectors
PublicationConstruction and technical condition of current collectors is crucial to reliability and safety of railway transportation. According to the Technical Specifications for Interoperability railway vehicles in the European Union should be equipped with carbon contact strips. Excessive wear or defects of contact strips degrade the capability of undisturbed power transmission, cause faster wear of contact wire, and can even result in...
-
SESSILE DROPLET CONTACT ANGLE OF WATER-Al2O3, WATER-TiO2 AND WATER-Cu NANOFLUIDS
PublicationThe goal of the present work was the experimental determination of the contact angle of droplets of three nanofluids on various substrates. Of particular interest was effect of nanoparticle concentration on droplet contact angle.
-
Sessile droplet contact angle of water–Al2O3, water–TiO2 and water–Cu nanofluids
PublicationThis work presents measurements of the contact angle of sessile droplets for three nanofluids, i.e. water–Al2O3, water–TiO2 and water–Cu. The plates made of glass, anodized aluminium and stainless steel of different roughness served as substrates. Ultrasonic vibration was used for 30–60 min in order to stabilise the dispersion of the nanoparticles. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight....
-
Continuum contact model for friction between graphene sheets that accounts for surface anisotropy and curvature
PublicationUnderstanding the interaction mechanics between graphene layers and co-axial carbon nanotubes (CNTs) is essential for modeling graphene and CNT-based nanoelectromechanical systems. This work proposes a new continuum contact model to study interlayer interactions between curved graphene sheets. The continuum model is calibrated and validated using molecular dynamics (MD) simulations. These are carried out employing the reactive...
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode.
PublicationThis study presents a novel approach to impedance measurements. The methodology discussed is limited to contact in the sample-probe system under ambient conditions without the presence of electrolyte. Comparison with results of direct and alternating current measurements for well-defined metallic surfaces are made. In spite of idealization related to the type of contact examined, the proposed technique provides an improvement of...
-
Morphology of damage inflicted on brittle polymer in lubricated contact under cyclic static load
PublicationIn this article morphology of damage inflicted on the polymethylmethacrylate (PMMA) plate in static point lubricated contact with a ball made of five different materials under cyclic normal load has been presented. It is argued that the counterface material and lubricating film play an important role in the damage process and the extent of damage inflicted in the PMMA plate.
-
Public Perception of Digital Contact Tracing App and Implications for Technology Acceptance and Use Models
PublicationGovernments are increasingly adopting digital contact tracing applications (DCT) as a key component of their response to the COVID-19 pandemic. However, governments are struggling to achieve widespread adoption of DCT necessary for obtaining the expected individual and public benefits associated with its use. Consequently, studies on DCT have focused on the barriers to DCT adoption in different contexts and possible ways of overcoming...
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode
Publication -
THE INFLUENCE OF DIFFERENT VEGETABLE DISPERSION PHASES ON THE ROLLING CONTACT FATIGUE OF BIODEGRADABLE LUBRICATING GREASES
Publication -
Localized impedance measurements of AA2024 and AA2024‐T3 performed by means of AFM in contact mode
Publication -
The effect of boiling in a thermosyphon on surface tension and contact angle of silica and graphene oxide nanofluids
Publication -
Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective Electrodes
Publication -
Optimized configuration interaction approach for trapped multiparticle systems interacting via contact forces
Publication -
Localized impedance measurements of AA2024 and AA2024-T3 performed by means of AFM in contact mode
PublicationPurpose: The purpose of this paper is to present the results of an atomic force microscopy (AFM) based approach to local impedance spectroscopy (LIS) measurement performed on AA2024 and AA2024-T3 aluminium alloys. Design/methodology/approach: AFM-LIS measurements were performed ex-situ without the electrolyte environment, so in fact the electrical not electrochemical impedance was obtained. Findings: Relative local impedance values...
-
Photoelectrochemical properties of BIMEVOX (ME=Cu, Zn, Mn) electrodes in contact with aqueous electrolyte
PublicationLayered oxide Bi4O2O11 and mixed oxides of bismuth, vanadium and a third metal (ME = Cu, Zn, Mn) were synthesized and characterized using XRD, Raman and SEM. The energy band gap (Eg) of samples determined using UV–VIS reflectance spectra equals to 2.46, 2.34, 2.27 and 2.18 eV for Bi4V2O11, BICUVOX (Bi2V1 − xCuxO5.5 − 3x/2), BIZNVOX (Bi2V1 − xZnxO5.5 − 3x/2) and BIMNVOX (Bi2V1 − xMnxO5.5 − x/2) (x = 0.1), respectively. Open circuit...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
A tribological research on a reciprocating sliding contact of aluminum-ferrous composite against cast-iron.
PublicationOpisano badania kompozytów: silumin AlSi11-żelazo albo silumin AlSi11-stal narzędziowa N9 (otrzymanych in situ), a także samego siluminu AlSi11 w skojarzeniu z żeliwem 350, przy tarciu ślizgowym w ruchu posuwisto-zwrotnym. Stwierdzono wpływ sposobu otrzymywania materiału kompozytowego na zużycie i opory ruchu skojarzenia badawczego, w szczególności materiały te zużywały się wolniej, niż silumin AlSi11.
-
A method of two-terminal excess noise measurement with a reduction of measurement system and contact noise
PublicationPrzedstawiono metodę i system do pomiaru szumów nadmiarowych dwójników elektrycznych ze znaczną redukcją wpływu szumów własnych systemu pomiarowego i szumów kontaków. Proponowana metoda może byc zastosowana do pomiaru szumów elementów z wyprowadzonymi końcówkami, bądź też struktur, gdy jako wzorcowy szum odniesienia może zostać zastosowany szum struktury rezystywnej wytworzonej bezpośrednio na strukturze w otoczeniu elementu testowanego.
-
Hyperbolic heat conduction at a microscopic sliding contact with account of adhesion-deformational heat generation and wear
PublicationDifferent non-Fourier models were proposed to simulate temperatures in materials subjected to extremely fast thermal disturbances, when the speed of heat propagation should be concerned. The present study investigated temperature and heat balance at a microscopic sliding contact during a single frictional interaction based on the Cattaneo-Vernotte hyperbolic heat conduction equation. Two fundamental features of friction, namely,...
-
CO2 capture through direct-contact condensation in a spray ejector condenser and T- junction separator
PublicationThe design principle underlying the steam condensation and CO2 purification in a gas power plant with a focus on reducing CO2 emissions encompasses the deployment of a spray ejector condenser (SEC) and separator. This innovative system facilitates direct-contact condensation of steam with non-condensable gas (CO2) by inter acting with a spray of subcooled water, seamlessly integrated with a T-junction separator mechanism aimed...
-
Assessment of respiratory responses to emotional virtual reality stimuli with non-contact respiration monitoring system
Publication -
The influence of type of dispersed phase on rolling contact fatigue of lubricating greases on mineral base oil
Publication -
Direct human contact with siloxanes (silicones): safety or risk. Part 1: characteristics of siloxanes (silicones
PublicationSiloxanes are commonly known as silicones. They belong to the organosiliconcompounds and are exclusively obtained by synthesis. Their chemical structuredetermines a range of physicochemical properties which were recognized as unique.Due to the susceptibility to chemical modifications, ability to create short, long orcomplex polymer particles, siloxanes found an application in many areas of human life.
-
Analysis of stress and strains, forces and energy in initial contact zone abrasive grain with treating material
Publication -
Scuffing and rolling contact fatigue resistance of discrete laser spot hardened austempered ductile iron
Publication -
Synergisms and antagonisms between MoS2 nanotubes and representative oil additives under various contact conditions
Publication -
A multi-label text message classification method designed for applications in call/contact centre systems
Publication -
Results from tests on bolted connection components for evaluation of friction coefficient in various contact conditions
PublicationThe main purpose of the work was the analysis and evaluation of the self-locking quality of a bolted joint covered with Xylan 1070 coating, with comparison to the classic bolts lubricated with Molykote compound during assembly. The second part of the work was the verification of the compliance of the bolts and nuts used in the installation with the ASME B1.1 norm.